| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.8 LAccepted-AOC | ₹95.8 L Quoted ₹1.0 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.1 Cr+₹5.4 L (5.26%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | ₹1.1 Cr+₹5.4 L (5.26%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹1.1 Cr+₹7.0 L (6.89%)Rejected-Finance | ₹1.1 Cr+₹7.0 L (6.89%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹1.3 Cr+₹31.9 L (31.3%)Rejected-Finance | ₹1.3 Cr+₹31.9 L (31.3%) | L4 | Rejected-Finance Not Being L1 |
| 5 | Rejected-Technical D NO 37 8 1 MANCHUKONDA GARDENS INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | - | - | Rejected-Technical Not enlisted in appropriate category i.e b (ii) |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
28 Jul 2022, 6:00 pmClosed
GE (I) (DM) VISAKHAPATNAM
GE (I) (DM) VISAKHAPATNAM Naval Dockyard 530014
REPAIR /MAINTENANCE OF LT ELECTRICAL PANEL BOARDS, METERING EQUIPMENT, SWITCH GEARS, LOAD TESTING OF PBS/CP, REPLACEMENT OF DEFECTIVE LT CABLES, CABLE AND JOINT TERMINAL FRESH ALL CABLE CONNECTIONS AT CP/ PB/ JB/ LT PANELS, REPLACEMENT OF UNSERVICEAB
2022_MES_531465_1
SSGE/8724/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (I) (DM) VISAKHAPATNAM
As per Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (I) (DM) VISAKHAPATNAM
₹2.1 L
Yes
5 Jan 2023
16 Jun 2022
5 Aug 2022
16 Jun 2022
28 Jul 2022
21 Jul 2022
Amount
Materials & Labors for de-carbonizing/ cleaning of LT 415/380 V 3 phase, 4 wire Junction boxes inside Jetty Gallery used for distribution of power to different pillar boxes by removing cover, by dismentling bunch of cable termination of 3ph+N busbar (cable terminations are not less than 16 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/ copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and and refixing all cable connections, replacement of damaged cable lugs and replacement of damaged nuts, bolts, washers and tightening of all nuts, bolts including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note:- (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only. (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
Materials & Labors for de-carbonizing/cleaning of LT 415/380 V 3 phase Air Circuit Breaker at Pillar boxes inside/above Jetty Gallery by removing outer door, inner door, by draw-out movable unit from base, keeping aside carefully, removing all cable connection from rear side bus, interconnection bus between main bus and ACB, checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC and re-fixing moving unit of ACB, cables, bus the same after applying Backtol (red) solution to the bus bar insulator and replacement of defective aluminium cable lugs and tightening the nuts, bolts, spring washers & thimbles complete all as specified and as directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate (c) all cleaning agents are included in the quoted rate.
Materials & Labors for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Pillar boxes inside/above Jetty Gallery by removing cover, by dismentling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint all as specified and directed. Note:- (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only. (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
Materials & Labors for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Cope points fixed at edge of Jetty with half portion above GL and half portion in gallery by removing cover, by dismentling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint all as specified and directed. Note:- (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only. (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
Servicing/ maintinance of multiple section of LT Panel board in one substation comprising minimum up to 05 Nos ACBs/ MCCBs/SDFs, busbar chamber, swich gear chamber, metering chamber cable termination/ tray chamber after opening front/ top/ side/ back cover by using forced air pressure and brushes, cleaning of all dust/ durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tightening of all nuts & bolts of busbar/ switchgear/ cable terminals, repair/ replacement to defective metering wiring from ACB/ MCCB/ CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of defective aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/ door knob and hinges complete all as specified and as directed. Note:- (i) Panel Meter, indicator lamp, MCB,busbar and CT will be measured and paid seperately as supply only. (ii) required aluminium cable lugs, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing/maintinance of ACBs measured seperatelly.
All as per item No 5.00 above but comprising ACBs /MCCBs/SDFs up to total 10 Nos
All as per item No 5.00 above but comprising ACBs /MCCBs/SDFs up to total 15 Nos
All as per item No 5.00 above but comprising ACBs /MCCBs/SDFs up to total 23 Nos
All as per item No 5.00 above but comprising ACBs /MCCBs/SDFs up to total 28 Nos
Servicing, repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and as directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) all cleaning agents are included in the quoted rate.
Servicing/maintenance of voltage stabilizer of capacity 1000 KVA to 1500 KVA by forced air cleaning of movable and fixed unit, decarbonize busbar chamber and checking for any defects due to any flush/ loose contact. Cleaning of all fixed and moving contact terminal connection points with CTC, replacement of defective cables complete all as specified and as directed. Note :- All cleaning agents are included in the adopted rate.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 150 to 185 sqmm. Make - 3M Cat Part No MHI/Ox1.1KV(HESL-4/4C) or equivelent of Denson/M Seal/MS Seal/RPG.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 240 to 300 sqmm. Make - 3M Cat Part No- MHI/Ox1.1KV(HESL-5/4C) or equivelent of Denson/M Seal/MS Seal/RPG.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 400 to 500 sqmm. Make-3M Cat Part No MHI/Ox1.1KV(HESL-6/4C) or equivelent of Denson/M Seal/MS Seal/RPG.
Supply only Heat Shrink sleave outer protection insulating tube (Coated) single core, for application range 13-38mm suitable for outdoor use to any weather condition. Make- RPG Cat Part No - WCSM-48/12 or equivelent of 3M/Denson/M Seal
Supply only coloured Heat Shrink sleave busbar insulation tube single core, for application range upto 150 mm. Make- RPG Cat Part No-WCSM-33/8 or equivelent of 3M/Denson/M Seal
Supply only Busbar anodised aluminium off sizes including required drilling holes for fixing with other bus / cable connections
Supply only Busbar anodised copper off sizes including drilling holes for fixing with other bus / cable connections
Supply only fixed contract of ACB 630A to 3200A
Supply only Moving contract of ACB 630A to 3200A
Supply Only Electronic protection unit of ACB 630A to 3200A
Supply Only shunt trip coil of ACB 630A to 3200A
Supply Only closing coil ACB 630A to 3200A
Supply only indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply and taking down unserviceable indication lamps complete all as specified and as directed. Cat Part No:-1SFA619402R5201 Make:-Siemens/C&S/schneider/ABB
Supply only metering current transformer of 1000/5 Amps class-1, 15 VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-06 or equivelent of Kappa/ AE
Supply only metering current transformer of 800/5 Amps class-1, 15 VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-06 or equivelent of Kappa/ AE
Supply only metering current transformer of 600/5 Amps class-1, 12.5 VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-06 or equivelent of Kappa/ AE
Supply only metering current transformer of 400/5 Amps, Class-1, 12.5VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-05 or equivelent of Kappa/ AE
Supply only metering current transformer of 300/5 Amps, Class-1, 5VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-05 or equivelent of Kappa/ AE
Supply only metering current transformer of 200/5 Amps, Class-1, 1.5VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-05 or equivelent of Kappa/ AE
Supply only metering current transformer of 100/5 Amps, Class-1, 2.5VA, complete all as specified and as directed. Make:-Rishabh Cat Part No- TW-03 or equivelent of Kappa/ AE
Supply only switch disconnector fuse unit, TPN, open execution, bolted fuse link, 415V, conforming to IS/IEC 60947-3, telescopic shaft for depth adjustment terminal shrouds on both side, door interlock facility of current rating 63 amps including boted HRC fuse-03 Nos Make : L&T Cat Part No- FN-63-TPN-SK-95651 & HRC fuse-ST-35828 or equivelent of Siemens/ABB/Havells.
All as per item No 34.00 above but capacity of 100 Amps. Make- L&T Cat Part No- FN-100-TPN-SK-95570 & HRC fuse-ST-30768 or equivelent of Siemens/ABB/Havells.
All as per item No 34.00 above but capacity of 125 Amps. Make- L&T, Cat Part No- FN-125-TPN-SK-95009 & HRC fuse-ST-30769 or equivelent of Siemens/ABB/Havells.
All as per item No 34.00 above but capacity of 315 Amps. Make- L&T Cat Part No- FN-315-TPN-SK-95590 & HRC fuse-ST-30782 or equivelent of Siemens/ABB/Havells.
All as per item No 34.00 above but capacity of 200 Amps. Make- L&T Cat Part No- FN-200-TPN-SK-95588 & HRC fuse-ST-30779 or equivelent of Siemens/ABB/Havells.
All as per item No 34.00 above but capacity of 250 Amps. Make- L&T Cat Part No- FN-250-TPN-SK-95682 & HRC fuse-ST-30781 or equivelent of Siemens/ABB/Havells.
All as per item No 34.00 above but capacity of 400 Amps. Make- L&T Cat Part No - FN-315-TPN-SK-95591 & HRC fuse-ST-30784 or equivelent of Siemens/ABB/Havells
Supply only HRC fuse of capacity 63 Amps Make - L&T Cat Part No - SF94027 and equivalent to standard/GE/Schneider
Supply only HRC fuse of capacity 100 Amps Make - L&T Cat Part No - SF94029 and equivalent to standard/GE/Schneider
Supply only HRC fuse of capacity 125 Amps Make - L&T Cat Part No - SF94030 and equivalent to standard/GE/Schneider
Supply only HRC fuse of capacity 160 Amps Make - L&T Cat Part No - SF94131 and equivalent to standard/GE/Schneider
Supply only HRC fuse of capacity 200 Amps Make - L&T Cat Part No - SF94132 and equivalent to standard/GE/Schneider
Supply only HRC fuse of capacity 250 Amps (Make L&T Cat No SF94333 and equivalent to standard/GE/Schneider)
Supply only dimmer stater for regulating voltage of voltage stabilizer capacity 1000 KVA to 1500 KVA, 3 phase, 415 volts, 50 Hz and taking out old unserviceable one complete all as specified and as directed. Make :Servo max/Jindal)
Supply only forward/reversible synchronous motor of torque 20 kg capacity for voltage stabilizer of capacity 1000 KVA to 1500 KVA, 3 Phase , 415 volts, 50 Hz and taking down old unserviceable one complete all as specified and as directed.
Supply only PCB of networking unit with complete resister and capacitor for voltage controlling/regulating for voltage stabilizer of capacity 1000 KVA to 1500 KVA 3 phase, 415 volts, 50 Hz and taking down old unserviceable complete all as specified and as directed.
Supply only PCB of electdronic micro processed based controller suitable for voltage stabilizer of capacity 1000 KVA to 1500 KVA 3 phase, 415 volts, 50 Hz and taking down old unserviceable one complete all as specified and as directed
Supply only frequency meter relay high/ low adjustable 96mmx96mm suitable for voltage stabilizer of capacity 1000 KVA to 1500 KVA 3 phase, 415 volts, 50 Hz and taking down old unerviceable one complete all as specified and as directed.
Dismantling taking out complete cable end of sizes 150 sqmm to 500 sqmm, 3.5 core from Cope point/ACB/MCCB/Pillar boxes/ junction boxes, cutting cable ends for replacement of burnt/defective aluminium cable lugs or heat shrink cable end Joints of suitable size or for outdoor heat shrink sleeves single core of suitable size for extended length of XLPE cable and fixing to ACB/MCCB/ terminals/busbars with nuts, bolts, washers, aluminium cable lugs complete all as specified and directed. Note:- (a) heat shrink cable end joints, heat shrink sleeves will be measured measured separately as supply only. (b) required aluminium cable lugs and nuts-bolts-washers and busbar insulator shall be inclusive of quoted rate.
Supply and fix heat shrink straight through joint, LT 1100 volts grade, 3.5 core, 150 to 185 sqmm after dismantling taking out cable from cable tray at gallery or at trench, after complete preparation complete all as specified and as directed. Make -3M Cat Part No - MHS/Ox1.1KV(HSLA-4/4C) or equivelent of Denson/M Seal/MS Seal/RPG
All as per item No- 54.00 here-in-above but of heat shrink straight through joint, LT 1100 volts grade, 3.5 core, 240 to 300 sqmm. Make - 3M, Cat Part No - MHS/ Ox1.1KV (HSLA-5/4C) or equivelent of Denson/M Seal/MS Seal/RPG
All as per item No- 54.00 here-in-above but of heat shrink straight through joint, LT 1100 volts grade, 3.5 core, 400 to 500 sqmm. Make - 3M Cat Part No - MHS/Ox1.1KV(HSLA-6/4C) or equivelent of Denson/M Seal/MS Seal/RPG
Supply and fix LT ACB 3 pole 3200 A, 50 KA breaking capacity, 415 V, 50 Hz, manual drawn out type and manually charged with micro processor ET2L trip unit (Without display) release protection system against over current, earth fault and short circuit with 2 NO + 2 NC auxiliary switch, safety shutter, cradle guard, operating handles conforming to IEC 60947-2 & 3 complete all as specified and as directed. Make- Cat Part No. MVS32N3MW2L of schneiderequivelent make in L&T/ABB/GE/lEGRAND
All as per item No. 57.00 above but of capacity 2500Amps, 3pole Make - Cat Part No. MVS25N3MW2L of schneider equivelent make in L&T/ABB/GE/Legrand
All as per item No. 57.00 above but of capacity 2000Amps,3pole Make - Cat Part No. MVS20N3MW2L of schneider equivelent make in L&T/ABB/GE/lEGRAND
All as per item No. 57.00 above but of capacity 1600Amps,3pole Make - Cat Part No. SPS16F3PMW2B of schneider equivelent make in L&T/ABB/GE/lEGRAND
All as per item No. 57.00 above but of capacity 1250Amps,3pole Make - Cat Part No. SPS12F3PMW2B of schneider equivelent make in L&T/ABB/GE/LEGRAND
Supply and fix MCCB, 3 pole, 400 amps, 36 KA breaking capacity, Ics = 100% Icu, with thermal magnetic release including taking out old one complete all as specified and directed. Make -Schneider/ABB/LEGRAND
Supply and fix MCCB, 3 pole, 630 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release.including taking out old one complete all as specified and directed. Make- Schneider Cat Part No- LV432876 or equivelent of Legrand/ABB
Supply and fix MCCB, 3 pole, 200 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release.including taking out old one complete all as specified and directed. Make - Schneider Cat Part No - LV431641 or equivelent of Legrand/ABB
All as item No 64.00 above but of size 3 pole, 250 amp, 36 KA. Make- Schneider Cat Part No- LV431780 or equivelent of Legrand/ABB
All as item No-64.00 above but of size 3 pole, 100 amps, 16 KA. Make- Schneider Cat Part No- LV429630/32/35 or equivelent of Legrand/ABB
All as item No-64.00 above but of size 3 pole, 160 amps, 36 KA. Make- Schneider Cat Part No- LV430630 or equivelent of Legrand/ABB
Materials & Labors for painting of outer surface of multiple section of complete VCB panel 11 KV size up to 2 m x 1.8 X 0.8 in one substation using one coat of synthetic enamel paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears complete all as specified and as directed.
Supply, fix and coonecting by mannual changover switchsheet steel enclosure version conforms to IEC 60947-3 of capacity 630 amps four pole including taking out old one complete all as specified and directed. . Make- L&T Cat Part No - CO46300OSOO or equivelent to Havells/indo asian.
Supply, fix and connecting mannual changover switchsheet steel enclosure version conforms to IEC 60947-3 of capacity 400 amps four pole taking out old one complete all as specified and directed. Make- L&T Cat Part No - CO44000OSOO or equivelent to Havells/indo asian.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. including.taking out old one complete all as specified and directed.
Materials & Labors for painting of outer surface of multiple section of complete LT Panel board size up to 5.5 m x 3.2 in one substation comprising ACBs/MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray using one coat of synthetic enamel paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears complete all as specified and as directed.
All as per item No 72.00 above but LT panel board size up to 7.5 M X 4.5 M.
M&L for painting of both side surface of MS cable trench cover using one coat of black bituminius paint after preparation of surface complete all as specified and as directed.
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmens complete all as specified and as directed including taking out of old unserviceable MS cable cover/support structure.Grade of steel Fe 410 -W (Gde E- 250) quality -A structure.
Dimantling, taking out all earth connection of strip from panel board to earth test point any size and replace the worn out earth strip, nut/ bolts/ washers connect all joint with new nots,bolts and washers to in original position complete all as specified and as directed. Note :- Earth GI strip measured and paid as supply only
Supply only Earth continuity conductor GI strip of size 32 X 6 mm .
Materials & Labors for Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high on LT panel board surface showing incoming and outgoing capacity in Amps and feeder name complete all as specified and as directed.
Load testing of PBs,Cope point and voltage stabilizer installed at various Jetty areas, Gallaries, substations using artificial electrical rectifier load bank of capacity from 1000 Amps to 2000 Amps including necessary required cable length input out put connection for testing and checking Voltage drop will rectified by checking cable size and loose connection, checking and record power factor to maintain 0.9 to 01, Load testing will be carried out in three hours continuously for 25%,50 %, 75% and 100% for one hours each objects respectively and all record will maintain and sheet submitted to department for record complete all as specified and as directed. Note :- (i) Artificial rectifier load bank shall be provided by department. (ii) Required man power for collection/handling and shifting from testing place to another place including deposit to original place after complete of testing work shall be arrange by the contractor. (iii) Required cable size and length for testing shall be arranged by the contractor.
Material and labour for filtration/dehydration transformer oil of Servo Voltage stabilizer, voltage grade 415 volts of any capacity inddoor type floor mounted in situ till achieve dielectric strength min 40 KV at 4 mm gap complete all as specifed and as directed.
Material and labour for topping up / replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade incl necessary dehydration to achieve dielectric strength min 40 KV at 4 mm gap complete all as specified and as directed. Make : GULF/Castrol/HP/Power/Savita
Supply, laying and connecting up XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 400 sqmm 3.5 core on surface / wall / duct / Pipe including necessary lux complete including taking down out old unserviceable cable complete and all as specified and as directed.
All as per item No 82.00 above but Size of 500 sqmm 3.5 core.
All as per item No 82.00 above but Size of 300 sqmm 3.5 core.
Supply and fix LT heat shrink cable end termination for cable sizes 240 to 300 sqmm 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends including disconnection cable ends from ACB / MCCB / Busbar and reconnection with existing new stainllss steel bolts of size not less than 16 mm dia and 40 mm long complete all as specified and as directed. Make- 3M Cat No MHI/OX1.1 KV (HESL-4/4C) or eqquivalent of Dension/M seal/RPG
All as per item No 85.00 above but for cable sizes 400 to 500 sqmm complete all as specified and as directed. Make- 3M Cat No MHI/OX1.1 KV (HESL-6/4C) or eqquivalent of Dension/M seal/RPG
Taking down unserviceable / burnt cable end termination by isolating power supply from transformer/ LT panel disconnecting burnt/ faulty cable from the bunch of cables in trenches/ duct, removing cable loop and material and labour for making Re-rout, cable termination of 3 1/2 core armoured aluminium conductor cable of size 95 sqmm to 500 sqmm, 1100 volts with suitable size of cable glands, aluminium lugs duly crimpled and insulated with insulation tape (in different colours) duly replaced the rusted nuts, bolts and washers of nickel chromium plated with new ones and applying petroleum jelly, testing and commissioning complete all as specified and as directed.
Dismantling taking out LT/ HT cable from panel/transformer/floor of sub station for repair or for realingnment of cable and refixing the cables with proper staking with proper alignment of cable and refixing the cables with proper on repaired/ existing rack/ trench and making feeder wise bundle of cable using PVC cable tie for sizes of cable 3.0/ 3.5 core 95 sqmm to 185 sqmm 11000/ 1100 volt grade including required alumium thimble complete all as specified and as directed. Note : Each cable shall be measured separately.
All as per item No-88.00 above but for cable sizes 240 sqmm
All as per item No-88.00 above but for cable sizes 300 sqmm
All as per item No-88.00 above but for cable sizes 400 sqmm
KIRON ENGINEERING CORPORATION
TECHNO SOFT SOLUTIONS
TOTCO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .