Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
25 Feb 2023, 6:00 pmClosed
GE (ARMY) NO 2 JODHPUR
Military Engineer Services, GE (ARMY) NO 2 JODHPUR, Near ASC Supply Depot, Ratanada Jodhpur-342011
REPAIR / MAINT OF INTERNAL ELECTRIFICATION, SUBMAIN WIRING IN MH AREA, 12 CDU, ECHS, CE OFFICE AND ADJOINING AREA UNDER GE (ARMY) NO 2 JODHPUR
2023_MES_578150_1
8844/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (ARMY) NO 2 JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (ARMY) NO 2
₹56,000
Yes
1 Jul 2023
31 Jan 2023
27 Feb 2023
31 Jan 2023
25 Feb 2023
11 Feb 2023
31 Jan 2023 - 10 Feb 2023
Amount
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
M&L for point wiring (Concealed modular) complete for one light point / fan point / exhaust fan point / bell point controlled by one 1-way switch / bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2. The cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate
All as per srl item no. 03 above but for one socket outlet 3 pin, 5 Amps on independent board.
All as per srl item no. 03 above but for one socket outlet 3 pin, 5 Amps on same board.
All as per srl item no. 03 above but for one light point controlled by two 2-way switches
All as per srl item no. 03 above but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire complete all as specified and as directed.
S & F Modular switch 1 way 6A , 1 module size complete all as specified and as directed.
S & F Modular switch 2 way 6A , 1 module size complete all as specified and as directed.
S & F Modular switch 1 way 16A , 1 module size complete all as specified and as directed.
S & F Modular Bell push way 6A with 2 module size with indicator complete all as specified and as directed.
S & F Modular Socket , 6 A , 5 Pin , 2 module size complete all as specified and as directed.
S & F Modular Socket , 6 A / 16 A , 5 Pin , 2 module size complete all as specified and as directed.
S&F of modular type regulator 2 module A/C 240 Volts.
M&L point wiring (Concealed Normal) for One light / fan / bell / exhaust fan point controlled by one no, 1-way, 5 Amps switch complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed MS sunken box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed. (Note : The cost of MS sunken box with 3 mm thick bakelite, laminated hylem sheet top cover is deemed to be included in quoted rate.)
All as per Srl Item No 15 above but for One light point controlled by two nos, 2-way, 5 Amps switch.
All as per Srl Item No 15 above but forOne socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per Srl Item No 15 above but for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per srl item no. 15 above but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
M/L Point wiring One light / fan / bell / exhaust fan point controlled by one no, 1-way, 5 Amps switch complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves Dash-fastners and cadmium plated screws all as per ISI including sunk type boxes for mounting fitting like switches, socketes fan regulators with 3 mm thick phenlic laminated sheet top covers concealed in walls etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly complete all as specified and directed .
All as per Srl Item No 17 above but for One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per Srl Item No 17 above but for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per srl item no. 15 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S&F of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and as directed.
S&F of Socket, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and as directed.
S&F of Switch piano type, single pole, one way, 15 amps, 230 volts, complete all as specified and as directed.
S&F of Socket, 6 pin, 5/15 Amp, multipurpose shutter type, 230 volts, complete all as specified and as directed.
S&F of Switch piano type, single pole, two way, 5 amps, 230 volts, complete all as specified and as directed.
S&F of resistance type regulator A/C 240 Volts.
S&F of Bell push, flush type 5 amps, 230 volts.
S&F of electric call bell ding dong AC 230 volts Single Pole.
S&F of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
S&F of Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed.
S&F of wall mounting light fitting City 2 and incl suitable size 9W retrofit LED bulb and making necessary electric connection, complete all as specified and directed.
S&F of LED Aviation light fitting and making necessary electric connection, complete all as specified and as directed.
S&F of wall mounting light fitting, Decorative type, wall mounting, SS finish fixture with opal glass diffuser suitable and incl suitable size 9W retrofit LED bulb and making necessary electric connection, complete all as specified and as directed.
Supply and fix in repair and replacement recessed and surface LED 1x4 PANEL ceiling light with high performance 40 watt Make : Crompton Cat part No LCTLRN-40-CDL(1X4) or equivalent make
S&F in replacement of recessed mounted LED light fitting of 2' x 2' size, suitable for false ceiling, 34/36 Watt, 6500K white light, metal body with white colour outer finish and acrylic diffuser including LED driver / transformer, spring loaded clips for easy mounting and making all electric connections complete all as specified and as directed.
S&F in replacement of recessed mounted LED light fitting of 2' x 2' size, suitable for false ceiling, 34/36 Watt, 3000K warm white light, metal body with white colour outer finish and acrylic diffuser including LED driver / transformer, spring loaded clips for easy mounting and making all electric connections complete all as specified and as directed.
Supply and fixing in replacement of Energy efficient round / square recessed mounted polycarbonate fixture flat panel 12W LED 6500K white down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed.
Supply and fixing in replacement of Energy efficient round / square recessed mounted polycarbonate fixture flat panel 12W LED 3000K warm white down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed.
Supply and fixing in replacement of Energy efficient round recessed mounted polycarbonate fixture flat panel 6W LED 3000K warm white down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed.
Supply and fixing in replacement of Energy efficient round recessed mounted spot light 2W LED 3000K warm white down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed.
Supply and fixing in replacement of Energy efficient round recessed mounted spot light 2W LED RED/GREEN/BLUE down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed.
S&F 22W Flexion LED strip 3000K with suitable driver and making necessary electric connection complete all as specified and as directed by Engineer-in-charge. Make : Havells Cat Part No LHEHCPP5IN1W018/WIPRO/CROMPTON
Supply and fixing in replacement of spike LED COB garden light 12W LED, Anthracite colour, made by aluminium and making necessary electric connection complete all as specified and as directed
S&F in replacement LED ceiling light driver 24W to 36W, 240V and complete all as specified and as directed.
S&F of plastic ventilating fan 200 mm sweep plastic body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and as directed. Note : Rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc
All as per item No 43 here in before but 250mm sweep
Taking down old recess / surface mounted light fitting and Fixing only with LED surface / recess ceiling light fitting, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. Note : LED recess / surface mounted light fitting shall be issued under Sch 'B'
Attending electric complaints for any type of COVID wards at MH area, to check the existing electrical items / points for serviceability of continuous electric supply, rectifying No light complaints including carrying out minor repairs / replacement etc as required to make the item functional and replacement of small pieces of wire, screw, refixing of hanging wires / Light fittings / ceiling fans / exhaust fans, DBs and switch boards etc complete all as specified and as directed. (i) Any other replacement of major items shall be measured & paid separately under respective items of this schedule. (ii) Electrician will ensure to wear complete PP Kit before enter into a COVID ward and use sanitizer regularly. (iii) Contractor will deploy one electrician with helper (keeping necessary electric tools & safety equipments) to attend electric complaints into various COVID wards (Like Family ward, Officers ward, JCOs/OR ward, OT, Lab, etc.,) at MH Jodhpur. (iv) In case Contractor fails to deploy electrician for any complaint, penalty @ Rs. 500/- per complaint shall be recovered from the Contractor
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified cat No 507811 Make : Legrand / Havells / ABB
S&F of Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Make : Havells Cat Part No DHDLVSRWGOFO04 / Schneider Elect / Legrand / ABB Note : MCCB & MCB will be measured and paid separately under respective items
All as per item No 48 here in before but TPN 4 way (Concealed flush to wall), Distibution Board
S&F of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 08 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
All as per item No 50 here in before but SPN 4 way (Concealed flush to wall), Distibution Board
Taking out old worn out wooden frame / steel frame and supply & single door sheet metal borad complete with flush door handle with locking arrangement painted with powder coated finishing with necessary PCC work complete size 1000x1000x300 Make : BCH Cat Part No BIL 50540 or Equivalent make in Hensel
All as per srl item no. 52 here-in-before but size 800x800x300 Make : BCH Cat Part No BIL 50310 or Equivalent make in Hensel
S&F of MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 125 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed. Make : Havells Cat part NoIHLASF0125 # / Schneider Elect / Legrand / ABB / Hager
All as per item No 54 here in before but 100Amp, 4 Pole MCCB
S&F of MCB, C Curve type, 10 kA, 63Amp, TPN with over load and short circuit protection, complete all as specified and as directed.
S&F of MCB, C Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as specified and as directed.
S&F of MCB, C Curve type, 10 kA, 40Amp, SPN with over load and short circuit protection, complete all as specified and as directed.
S&F of MCB, C Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and as directed.
Taking down old sub main wiring and M&L for sub main wiring with 2 run of 10 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate casing caping, ISI marked, 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Two run of 10 Sq.mm. and one run of 10 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
All as per srl item no. 60 above but with 2 run of 6.0 sq mm FRLS copper wire with one run 6 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 60 above but with 2 run of 4.0 sq mm FRLS copper wire with one run 4 Sqmm FRLS copper cable as earth wire.
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
ABHOG INFRASTRUCTURE PRIVATE LIMITED
Inkhead Corporation
vinayandsons
M/S VENUS BUILDER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .