| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC VPO BAHANG TEH MANALI DISTT KULLU HP | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹8.9 L+₹1.2 L (15.9%)Rejected-AOC | L2 | Rejected-AOC other than lowest |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
28 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103
REPAIR/ MAINTENANCE OF CEILING,ROOFING AND OTHER B/R WORKS IN OTM ACCN AT PALCHAN
2022_MES_525868_1
AGE(I)/MNL-04/2022-23
Open Tender
Civil Works
Item Rate
240 days
Palchan
Refer NIT and Tender Documents
5 documents required · 5 mandatory
₹500
AGE I R AND D MANALI
₹14,000
Yes
30 Jul 2022
24 May 2022
30 Jun 2022
24 May 2022
28 Jun 2022
7 Jun 2022
60 days
Amount
Dismantling wall and ceiling board any of description complete all as specified and directed by Engr-in-Charge.
M&L for 12 mm thick perforated particle board/tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid as in ceilings complete all as specified and as directed by Engr-in-charge Note:- Framework for ceiling shall be measured and paid separately).
All as per ser Item No.2 above but except boarding.
M&L for 4mm thick plain AC boards as in ceiling fixed with screws to framework complete all as specified and as directed by Engr-in-charge.
All as per ser item No 4 above but except boarding.
M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to frame work as in ceiling complete all as specified and as directed by Engr-in-charge
M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to frame work as in wall paneling complete all as specified and as directed by Engr-in-charge
S&F, anodised aluminium snap grid frame work for false ceiling size of grid 605 X 605 mm complete all as specified and as directed by Engr-in-charge
M&L for 6 mm thick Plywood grade BWR type BB board of any size fixed with screws to timber frame as ceiling fixed flat or in sloping, complete, all as specified and directed by Engr-in-Charge
M&L for 6 mm thick Plywood grade BWR type BB board of any size fixed with screws to timber frame as in wall paneling fixed, complete, all as specified and directed by Engr-in-Charge
S&F, 12mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work as in wall paneling, all as specified and directed by Engineer-in-charge.
S&F, 12mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work as in ceiling, all as specified and directed by Engineer-in-charge.
M&L for Plain fillets,square,rectangular or triangular in section, clean sawn, secured with nails or brads of size exc 3sq cm and n exc 6 sq cm of second class softwood all as specified and directed by Engineer-in-charge.
M&L for repair for Second class softwood timber framed and fixed, Clean sawn in scantling, all as specified and directed by Engineer-in-charge.
M&L for Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engr-in-charge
M&L for Preparation of new ceiling surfaces and applying three coats of white wash complete all as specified and as directed by Engr-in-charge
M&L for Preparation of old ceiling surfaces and applying one coats of white wash complete all as specified and as directed by Engr-in-charge
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F, mild steel in Joist, channel, angle, or tee sections, Hollow or round steel tubes, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe 410 -W (GdeE- 250) quality-A, complete all as specified and directed.
S & F, mild steel Windows Chajja / wind ties for roof covering including screwing bolts, etc complete all as specified and directed.
S&F, Pre-painted galvalume aluminium sheet zinc coatin GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F, 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and directed.
All as per ser Item No 23 here-in-before but except sheets, complete all as specified and directed.
S&F, Pre-painted galvalume aluminium sheet zinc coatin GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying 2 coats of Synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
All as per ser Item No 26 here-in-before but one coat of synthetic enamel paint over old surface of Wall, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the permises complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in subbase of floor complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Screed bed or bedding layer in cement mortar 1:6 for laying of floor tiles complete all as specified and directed by Engr-in-Charge.
M&L for vitrified tiles light coloured 10mm thick, polished, area of each tiles not exc 0.36 sqm, in floor, skirting etc, set and jointed in neat cement slurry and pointed in coloured cement to match
M&L Rolled section as in main and cross beams, hip and jack rafters, pirlins where connected to common rafter and running rails and guldes for sliding doors. Fixed with anngle cleats or other connecting plates Fe 410-W (Gde E-250)
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc. 1.5 Sqm and n. exc 4 Sqm each.
S&F, Mild steel for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ,Fe 410-W, Gde E-250, complete, all as specified and directed by engineer-in-charge.
S&F, Plain, black, mild steel sheeting, 1.25mm thick, in ridges, doors, hips, valley gutters, drip and straight flashings (length and girth as fixed), with welded or soldered provided complete, all as specified and directed by engineer-in-charge.
M&L for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, all as specified and directed by engineer-in-charge.
S & F, Mild Steel butt hinges, medium weight cold rolled 100mm size all as specified and directed by Engineer - in - Charge .
S & F, mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified and directed by Engineer - in - Charge .
S&F in repair 15 mm bore chromium plated fancy type brass angle valve with elegant knob screwed down high pressure screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge
S&F in repair 15 mm bore chromium plated fancy type bib taps with elegant knob screwed down high pressure complete all as specified and directed by Engr-in-Charge
S&F in repair for 25mm dia MS curtain rod with PVC coating (decorative type) fixed with MS hooks incl side brackets (both side) complete all as specified and as directed by Engineer-in-Charge.
NATHU RAM AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .