BILL OF QUANTITIES
NAME OF WORK:-RIVERSIDE SAVORIES-CONSTRUCTION OF BUILDING WITH
TUNNEL ROAD AND BETWEEN NEHRU BRIDGE TO ELLISBRIDGE, RIVERFRONT-
RECAPITULATION SHEET
No. Item of Works Amount in Rs.
A Civil Works + plumbing Work
B Electrical & ELV, HVAC Work
C Fire Protection Work
Total Amount(Without GST)
Total Amount(Without GST)
(VOLUME - 3 For Civil & PHE Works)
Price Bid: Bill of Quantities (BOQ)
Tender Amount : Rs.
Contractor's Quoted Rates :
PLEASE NOTE : PLEASE DO NOT FILL PRICE BID IN HARD COPY.
No. Item of Works Amount in Rs.
B Plumbing Work
NAME OF WORK- RIVERSIDE SAVORIES-CONSTRUCTION OF BUILDING WITH TUNNEL ROAD AND BETWEEN NEHRU BRIDGE TO ELLISBRIDGE,
RIVERFRONT-WEST.
SCHEDULE OF QUANTITIES
Description of Item Unit Total QTY Rate(Rs.) Amount(Rs.)
Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling
1 and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable Sqm 30,718.80 2.81
materials. (C) By mechanical means in area of light jungle
Cutting and felling trees of girth as specified below (measured at a height of 1 m above ground
level) including cutting of trunks and branches, removing the roots and stacking of serviceable
2 material and disposal of unserviceable materials within campus at directed place etc complete all
as per specifications and as directed by the Engineer-in-charge
2.1 Girth beyond 30 cm, up to and including 60 cm girth. NOS 5.00 451.00
2.2 Girth beyond 60 cm, up to and including 120 cm girth. NOS 5.00 2,011.00
Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and
disposal of unserviceable materials with all lead and lift.
4 Demolition and disposal of unserviceable materials with all lead and lift.(i) Cement concrete. Cum 619.28 603.23
Demolition including stacking of serviceable materilas and disposal of unserviceable materials with
all lead and lift. (i) R.C.C. work
Dismentling barbed wire in fencing including making rolls and also including dismentling fencing
posts including all earth work concrete in base and making good the disturbed ground stacking
useful materials as directed and disposing as directed and disposing of the unserviceable materials
with all lead and lift
Demolition of Brick work and stone masonry including stacking of serviceable materilas and
disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.
Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and
dismantling of concrete etc. in base of : T’ or ‘L’ iron or pipe
9 Dismantling Digital Led Advertisment Hording Board NOS RO
Dismentling wood work, wrought framed and fixed in frames trusses including stacking the materials
with all lead and lift.
11 Dismentling steel work including distempering and stacking the materials with all lead and lift. KG 500.00 3.63
Scarifying gravelled macadam or bitumen macadam surface 6cm to 10cm .depth including
stacking useful materials on roadside and disposing off remaining stuff.
Excavation for foundation up to 1.5 m DEPTH including sorting out and stacking of useful material
sand disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation up to 1.5 m TO 3.0M DEPTH including sorting out and stacking of useful
14 material sand disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil Cum 26,911.50 128.52
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful
15 materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil Cum 35,882.00 141.11
Extra for additional depth more than 5.0 m for excavation for foundation including sorting out and
16 stacking of useful materials and disposing of the excavated stuff upto 50 m lead.(A) Loose or soft Cum 17,941.00 162.02
Extra for additional depth more than 6.0 m for excavation for foundation including sorting out and
17 stacking of useful materials and disposing of the excavated stuff upto 50 m lead.(A) Loose or soft Cum 11,661.70 182.93
Conveyance charges of earth lime, murrum, building rubbish, manure, garbage, sludge,
18 excavated rock, fly ash, aggregate of any kind etc. comp. upto any lead. up to 1.0 km Cum 12,000.00 256.16
18.1 Above 1.0km & up to 5 km Cum 24,000.00 326.73
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in
19 layers not exceeding 20cm. In depth consolidating each disposited layer by ramming and Cum 59,620.80 129.10
Carring out plinth treatment to pre or post construction / existing structure by spraying chemical
solution for termite control treatment including labour and material consistment with I.S.I
specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight
20 one percent is recommended i.e one litre 20 EC chemical emulsion with 19 liter give 1 % Sqm 13,036.07 104.90
concrentration inclusive of one litre chemical emulsion appication at the rate of 5 Litre chemical /
Sqm of surface is recommended as per I.S and as per directions of Clerk-of-Work. For all levels and
Providing and filling rubble soling including hand packing and filling interstices with quarry spalls
21 below hardscape and others for infrastructure work in external development as directed by EIC. Cum 100.00 2,370.00
PLAIN AND REINFORCED CEMENT CONCRETE
Providing and laying cement concrete 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregates
22 20mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth Cu.m 1,682.57 3,661.30
Providing and laying in position M- 250 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
23 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 1,005.10 4,853.56
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash(GRADE SLAB)
Providing and laying in position M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
24 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 6,775.50 5,140.94
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash (Foundation)
Providing and laying in position M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
25 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 4,958.30 5,140.94
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash (RCC BEAM)
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
reinforcment(Second Floor)
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
25.2 reinforcment(utility Floor) Cu.m 627.99 79.70
Providing and laying in position M-250 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
26 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 151.20 4,853.56
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash (RCC LINTEL)
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
reinforcment(Second Floor)
Providing and laying in position M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
27 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 2,514.40 5,140.94
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash (RCC COLUMN)
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
Providing and laying in position M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
28 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 5,765.50 5,140.94
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash(RCC WALL)
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
Providing and laying in position M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and
transporting the concrete from Plant to point of laying, excluding the cost of centering shuttering
29 finishing and reinforcement including cost of admixtures in recommended proportions as per IS: Cu.m 6,256.53 5,140.94
9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and
durability as per direction of the Engineer - in - charge. Without Fly Ash (RCC SLAB)
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of
Providing and laying in position M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant
andtransporting the concrete from Plant to point of laying, excluding the cost of centering
30 shuttering finishing and reinforcement including cost of admixtures in recommended proportions as Cu.m 409.55 5,140.94
per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing
strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (STAIRCASE)
Providing TMT Bar FE 550D reinforcement for R.C.C. work including bending, binding and placing in
position complete upto floor two level ( Foundation to First Floor )
31.1 Extra for additional lift of reinforcing steel for all R.C.C. work above floor two level. Kg 2,59,842.20 0.99
31.2 Extra for additional lift of reinforcing steel for all R.C.C. work above floor two level. Kg 2,55,694.95 1.98
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. Height of propping and centering below supporting floor to
32 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 16,503.22 171.68
concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. height of propping and centering below supporting floor to
33 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 2,411.64 297.68
concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
34 thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (G) Sqm 2,411.64 94.02
Columns, Pillars, Posts and struts. (1) Square, Rectangular or polygonal in plan.
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. height of propping and centering below supporting floor to
35 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 7,322.91 422.10
concrete work in. (G) Columns PillarsPosts and struts. (2)Circular or curved in Plan.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
36 thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (G) Sqm 7,322.91 94.02
Columns, Pillars, Posts and struts. (2) Circular or curved in plan
Extra for additional height of propping and centering where the height of propping and centering
37 exceeds 4 .O M between supporting floor to ceiling including temporary brick or stone pillars for Sqm 3,649.04 682.01
supporting as required. (ii) Height more than 5.0M.and upto 6.0 M.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
38 thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (G) Sqm 3,649.04 94.02
Columns, Pillars, Posts and struts. (1) Square, Rectangular or polygonal in plan.
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. height of propping and centering below supporting floor to
39 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 6,138.66 229.95
concrete work in. (C) Vertical surface such as walls (any thickness) partitions and the like including
attached buttresses & string course & the like.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
40 thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (G) Sqm 6,138.66 94.02
Columns,Pillars, Posts and struts. (1) Square, Rectangular or polygonal in plan.
Extra for additional height of propping and centering where the height of propping and centering
41 exceeds 4 .O M between supporting floor to ceiling including temporary brick or stone pillars for Sqm 1,509.42 386.48
supporting as required. (ii)Height more than 5.0 M.and upto 6.0 M.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
42 thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (G) Sqm 1,509.42 94.02
Columns,Pillars, Posts and struts. (1) Square, Rectangular or polygonal in plan.
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. height of propping and centering below supporting floor to
43 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 11,632.50 229.95
concrete work in. (C) Vertical surface such as walls (any thickness) partitions and the like including
attached buttresses & string course & the like.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
44 thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (G) Sqm 11,632.50 94.02
Columns,Pillars, Posts and struts. (1) Square, Rectangular or polygonal in plan.
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. Height of propping and centering below supporting floor to
45 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 33,638.00 252.00
concrete work in. (B) Flat surfaces such as soffits of supspened floors slabs Landings and the like. (1)
Floors etc. upto 200 mm in thickness.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (B)Flat
surfaces such as soffits of slabs Landings and the like. (1) Floors etc. upto 200mm in thickness.
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. height of propping and centering below supporting floor to
47 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 39,771.47 192.15
concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers
and Lintels not exceeding 1 M. in Depth.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (H)(1) Sides
and soffits of Beams, Beam Haunchingscantilevers Girders, Bressumers and Lintels not exceeding
Providing formwork of ordinary timber planking so as to give a rough finish including centering
shuttering strutting and propping etc. Height of propping and centering below supporting floor to
49 ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain Sqm 2,356.66 252.00
concrete work in. (B) Flat surfaces such as soffits of supspened floors slabs Landings and the like. (1)
Floors etc. upto 200 mm in thickness.
Extra for Providing formwork with sheathing steel sheets or Plywood Sheets (Using Minimum 12 mm
thick Shuttering Plywood, conforming to IS:4990) so as to give a Fair Exposed F3 finish in (B)Flat
surfaces such as soffits of slabs Landings and the like. (1) Floors etc. upto 200mm in thickness.
Earthwork for embankment including breaking clods, dressing with all lead and lift and including
watering rolling and consolidation of subgrade in layers at O.M.C. to required dry density including
filling the depression which occur during the process using power roller 8T to 10T.(E) From Borrow
area within 3.0KM. lead
Construction of 300mm (as per IRC 37) ThickGrannular sub base(GSB‐I) by providing coarse graded
material using B.T Metal 53 mm to 26.50 mm @ 35 % ,26.50 mm to 4.75mm 45% & Coarse sand below
52 2.36 mm 20 % in uniform layer with motor grader on prepared surface mxing by mix in place Cu.m 1,687.68 1,443.27
method with vibratory roller to achive the desired density complete as per close
Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and
fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm,
aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per
53 table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be Cu.m 969.00 3,335.86
determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,
mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting
with 8-10 tonnes vibratory roller, finishing and curing.
Construction of reinforced, dowel jointed, plain cement concrete of M40, pavement over a
prepared sub base with Ordinary Portland Cement @ 400 kg per cum, coarse and fine aggregate
conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a
batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or
54 slip form paver, spread, compacted and finished in a continuous operation including provision of Cu.m 1,938.00 7,491.00
contraction, expansion, construction and longitudinal joints, joint filler, separation membrane,
sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing
compound, finishing to lines and grades as per drawing.
Providing and laying cement concrete 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregates
55 20mm nominal size) and curing complete excluding cost of formwork in Footpath. Cum 67.83 3,661.30
Applying and providing Expansion joint sealing System on 100 mm vide joint including cleaning of
expansion joint by mechanical means provision of adhesive and flexible membrane with required
56 bond length as per menufracturer specification and 4mm thick alluminium strip covering with one RMT 199.50 4,724.75
side sloted and bolted with suitable system, inclusive of all manpower, machinery and material as
per specification and as directed.
Trimix flooring - BROOM FINISH
Providing and laying C.C. pavement of mix M-25 with batch mixed concrete from batching plant.
The concrete shall be casted in panel and finished with screed board vibrator, vacuum dewatering
process and finally finished by floating, brooming with machine. Grooves to be made of size 5mm
wide and one third of thickness of concrete within 48 Hours of concreting to form bay of 4 x
meters using heavy duty cutting machine with diamond cutting wheel and filling of the groove with
appropriate sealant etc. complete as per specifications and as directed by the EIC. If trimix
concrete shall be laid over on existing concrete surface, bonding agent shall be applied before
laying of concrete at all basements floors. Reinforcement if required shall be paid in relevant
Extra for carrying out Tremix - Vacuum-dewatering (VDF) for driveway and other floor area as
specified in detail drawing, it shall have contraction/sawed joints to be formed at every 10m
distance by grooving with mechanical saw within 48 hrs. operation should be carried out as soon
as concrete is ready to accept the saw cut w/o trowelling etc. as directed by EIC. Groove sawed
joints of min. 5 mm thickness and 100 mm minimum depth (2/3rd depth of the pavement) with
compressible shalitex board or equivalent. It shall be well compacted, mechanically vibrated,
58 finished to required level, floated with neat cement with power trowel machine to get desired finish Sqm RO
(smooth/broom), or a levelling course, including MS shuttering, curing for 7 days etc. complete. The
reinforcement for Tremix floor to be installed as per drawing and contractor shall allow for one
mock-up for approval without cost. The sealant could be Semifigid Sealant M-80 of approved
make. The rate shall be inclusive of labour, grooves and machinery cost. The rate of concrete and
steel shall be paid in relevant items separately
Masonary work using Aerated light weight concrete block having crushing strength not less than
59 kg/sqcm for super structure above plinth level upto floor two level in cement mortar 1:5 ( 1 cement : Cu.m 3,190.19 4,483.73
5 fine sand ) complete as per Technical Specification.(upto first floor)
Masonary work using Aerated light weight concrete block having crushing strength not less than
59.1 kg/sqcm for super structure above floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) Cu.m 767.54 4,526.39
complete as per Technical Specification.(Second floor)
Masonary work using Aerated light weight concrete block having crushing strength not less than
59.2 kg/sqcm for super structure above floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) Cu.m 160.27 4,569.05
complete as per Technical Specification.(utility terrace)
Brick work using common burnt clay building bricks having crushing strength not less than
60 kg./Sq.Cm. in Sub Structure and Super Structure in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(A) Cu.m 1,113.87 4,607.37
PLASTERING AND PAINTING
Providing 15 mm. thick cement plaster in single coat on fair side of brick wall for interior plastering
upto floor two level finished even and smooth in [II] Cement mortar 1:4 (1 cement : 4 fine sand) For
all levels, hights and leads of works. etc, complete for all floor heights as directed. Rate shall be
inclusive of hexagonal chickenmesh at junction of concrete and brick work. Minimum width of the
chicken mesh shall be 150 mm covering the brick / concrete surface equally, as directed by EIC.(
Upto first floor)
Providing 15 mm. thick cement plaster in single coat on fair side of brick wall for interior plastering
above floor two level finished even and smooth in [II] Cement mortar 1:4 (1 cement : 4 fine sand)
For all levels, hights and leads of works. etc, complete for all floor heights as directed. Rate shall be
inclusive of hexagonal chickenmesh at junction of concrete and brick work. Minimum width of the
chicken mesh shall be 150 mm covering the brick / concrete surface equally, as directed by
EIC.(Second floor)
Providing 15 mm. thick cement plaster in single coat on fair side of brick wall for interior plastering
above floor two level finished even and smooth in [II] Cement mortar 1:4 (1 cement : 4 fine sand)
For all levels, hights and leads of works. etc, complete for all floor heights as directed. Rate shall be
inclusive of hexagonal chickenmesh at junction of concrete and brick work. Minimum width of the
chicken mesh shall be 150 mm covering the brick / concrete surface equally, as directed by
EIC.(Utility terrace)
Providing and laying average 20 mm. thick double coat Sand face/Mala cement plaster on
external walls upto any height above ground level and for all shapes consisting of average 14 mm.
thick backing coat of CM 1:3 (1 cement: 3 coarse sand) and average 6 mm. thick uniform grained
textured finish coat using wooden Gutka, in CM 1:1 (1 cement: 1 sand),with line , level & plumb,
including scaffolding, forming grooves, drip moulds, pattas, hacking RCC surface, curing etc.
complete. as directed by EIC. Rate shall be inclusive of hexagonal chickenmesh at junction of
concrete and brick work. Minimum width of the chicken mesh shall be 150 mm covering the brick /
concrete surface equally.
Providing 10mm thick cement plaster in single coat on ceiling upto floor two level and finished
even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand)
Applying two coats of acrylic putty & two coats of primer of approved brand and manufacture on
64 new wall surface to give an even shade including thoroughly brushing the surface free from mortar Sq.m 53,193.83 40.19
dropping and other foreign matter and sand papered smooth.
Providing and painting internal walls with two coats of plastic emulsion paint of approved make &
of shade. The rate shall include for all ladders, scaffolding and supports and including complete
surface preparation, including scraping the surface off existing surface paint, loose particles and
cleaning and applying primer and putty as necessary to achieve a surface in perfect line and
level. Wherever necessary, POP punning or cement plastering needs to be done as per site
condition, if the plastered surface has chipped off. The final finished surface should be smooth and
in perfect line and level without undulations on surface. etc. complete as directed by EIC.
Providing, applying and finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly brushing the surface to remove
all dirt, and remains of loose powdered materials.etc complete. as directed by EIC.
Providing & laying broken white china mosaic flooring for plain and curved surfaces, comprising of
12 to 20 mm. size broken pieces of white glazed tiles laid over water proofing using cement mortar
1:3 bedding, The flooring shall be tampered to bring the mortar cream up to the surface, including
67 rounding of the junctions and extending them upto 30 cm. along the parapet wall. The rate shall Sq.m 4,890.00 739.89
include bands, if different colour is used, any pattern or design as per drawing and direction,
curing, cleaning with water and oxalic acid, etc. complete. as directed by EIC.
Providing and laying integral cement based waterproofing treatment of the agency approved by
department, including preparation of surface as required for treatment of roofs, terraces etc mixing
with waterproofing compound as per IS:2645, with average thickness of 115mm and minimum
thickness at drain point as 65 mm. Following works are included in above item
(i) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with
proprietary water proofing compound over the RCC slab including cleaning the surface before
(ii) Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of
cement mortar 1:4 (1 cement : 4 coarse sand) using Ready mix mortar admixed with proprietary
water proofing compound over 20 mm thick layer of cement mortar of mix 1:4 (1 cement : 4 coarse
sand) using Ready mix mortar admixed with proprietary water proofing compound to required
68 slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions Sq.m 4,890.00 1,425.00
of walls and slabs.
(iii) After two days of proper curing applying a second coat of cement slurry admixed with
proprietary waterproofing compound.
(iv) Finishing the surfaces with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse
sand) using Ready mix mortar admixed with proprietary water proofing compound and finally
finishing the surface to receive the China Mosaic waterproofing treatment.
(v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for
curing and for final test. All above operations to be done in order and as directed and specified by
the Engineer in Charge.
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures
like Rafts, Retaining Walls etc. into the drum of the ready-mix truck in powder form, using integral
crystalline admixture @ 0.80% by weight of cement content per cubic meter of concrete or as
recommended by Manufacturer. The material shall meet the requirements as specified in ACI-212-
3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control
concrete as per DIN 1048 Part 5 & resistant to 16 bars hydrostatic pressure. The crystalline admixture
69 shall be capable of self-sealing of cracks up to a width of 0.5 mm by forming insoluble microscopic
needle shaped crystals through ctalyst reaction with un-hydrated cement particle and moisture.
It should be hydrophilic in nature, should be able to grow crystals year after year to seal
For M- 250 grade(Cement level 450 kg ) (GRADE SLAB)
69.1 Admixture Dosage :- 3.6Kg/m3 KG 3,618.23 215.00
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures
like Rafts, Retaining Walls etc. into the drum of the ready-mix truck in powder form, using integral
crystalline admixture @ 0.80% by weight of cement content per cubic meter of concrete or as
recommended by Manufacturer. The material shall meet the requirements as specified in ACI-212-
3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control
concrete as per DIN 1048 Part 5 & resistant to 16 bars hydrostatic pressure. The crystalline admixture
70 shall be capable of self-sealing of cracks up to a width of 0.5 mm by forming insoluble microscopic
needle shaped crystals through ctalyst reaction with un-hydrated cement particle and moisture.
It should be hydrophilic in nature, should be able to grow crystals year after year to seal
For M- 350 grade(Cement level 500 kg ) (Foundation)(RCC Wall) (RCC SLAB)
70.1 Admixture Dosage :- 4Kg/m3 KG 61,528.22 215.00
Providing and applying Synthetic Rubber based Swelling Waterstop tape, 20mm x 5mm thick for
construction joints treatment of RCC structure such as retaining walls and at the junctions of raft
slab with the retaining walls etc. After cleaning the surface, one coat of required adhesive for
swellable water stop shall be applied throughout the length of the joint. Over the primed surface
Swelling Waterstop shall be placed. The waterstop conforms to the following swelling properties:
Swelling percentage of swelling waterstop in clear water 1000%, concrete water 800% & salt water
300%. The work shall be carried out all complete as per manufacturer specification.
WET Areas - Sunk Slab, Bathroom, Kitchen, Podium, Terrace, OHT & UGT Water Proofing
(Cleaning and Preparation of surface with help of wire brush or grinder, wash the slab with clean
water. Remove all loose concrete, grease, oil using wire brush and scrubber. Repair and fill all
cracks, joints and annular space is included)
Supply and application of 2mm thick with a covergae of 3.2kg/sqm in 2 coats two-component,
high flexible, elastic cementitious mortar made from cementitious binders, fine-grained selected
aggregates, special admixtures and synthetic polymers in water dispersion with an elongation of
120% (DIN 53504), Static crack bridging ability of >2.5mm (EN 1062-7), Permeability to water vapour
sD = 3.6 m, µ = 1800 (EN ISO 7783-1), Impermeability to water < 0.05kg/m²·h0.5 (EN 1062-3),
Permeability to CO₂ sDCO2 >50m (EN 1062-6), Reaction to fire (Euroclass): E (EN 13501-1), adhesion
72 to concrete after 28 days: 1.3N/mm² (EN 1542) when applied @ 2mm thickness (in 2 coats) on the Sq.m 2,000.00 1,127.00
surface prepared for waterproofing to be carried out to ensure the mechanical properties of the
product with Mapenet 150. The application of the product shall be carried out after the thorough
preparation of the surface which includes cleaning, crack treatment, corner joint treatment,
grouting and priming primer having Colour: opalescent Speci c gravity (kg/l): 1.01 Dry solids
content (%): 15 Brook field Viscosity # 1, rpm 10 (mPa·s): 20 in dilution with water {1:1}.
Addionally apply fiber net for reinforcing the waterproofing membrane and with Mapenet
tensile strength should be complied minimum 3.2 MPa after curing.
1. Tensile Strength : 3.2 Mpa
2. Crack Bridging: 2.8 mm
Water Tank Plastering & Food Grade Epoxy
Underground Water Tank and Overhead Water Tank -Plastering & Internal coating
(Cleaning and Preparation of surface with help of wire brush or grinder, wash the slab with clean
water. Remove all loose concrete, grease, oil using wire brush and scrubber. Repair and fill all
cracks, joints and annular space is included)
Plaster Over Waterproofing Membrane: Before application of food grade epoxy supply &
application of concrete plaster on avg thickness of 15-20mm by adding water proofing compound
@200 ml per bag of cement.
Food Grade Epoxy: Supply and application of two-component epoxy paint made from epoxy
73 resins and special pigments with high covering capacity for anti-acid and non-toxic coatings on Sq.m 1,252.91 828.00
concrete surfaces. Apply two coats of the product on a solid, clean substrate treated with primer
(not included) with a brush, roller or by airless spray. Wait between 6 and 24 hours between each
coat, according to surrounding conditions. The product must comply with the principles defined in
EN 1504-2/-9 and have the following characteristics like, Abrasion resistance:(EN ISO 5470-1) <600
mg, Permeability to CO₂: (EN 1062-6) > 900 m, Permeability to water vapour: (EN ISO 7783-1-
2) Class III, Resistance to thermal shock (1x): (EN 13687-5) 3.5 MPa, Taber abrasion resistance (g):
0.1; viscosity - rotor
PAVING AND FLOOR FINISHING
Providing & laying machine cut & machine polished (mirror finish) 18mm - 20mm thick Granite Stone
of Steel Grey /Sadarhalli / Z Brown / Brown or other approved colour at all floor & location in
necessary cement mortar bedding /backing, close jointed & grouted with matching cement slurry
and rounding of edges, finished to line, level,curing etc. as required, including cutting of stone slab,
74 wastage, making cut outs, grooves wherever required, machine polishing/ hand polishing (where
machine cannot have access) etc. complete all as per specifications, drawings and as directed by
the Engineer in charge. Note: Top exposed surface on plan &exposed vertical finished face shall be
measured for payment in Sqm.
In flooring with machine polished Granite stone of size 800mm x 800mm/ 1000mm x 1000mm / (and
any other size and pattern as per drawing) laid over & including 20mm thick cement mortar1:4 (
74.1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm Sq.m 1,759.91 2,750.00
over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints.
18 mm thick one side machine polished granite stone of approved colour, shade and surface finish
for Cladding/dado/riser/treads with stone slabs of various sizes in pattern including 12 mm thick 1:4
cement mortar (Using ready mix mortar) backing, fixing of 6mm (approx.) size angular stone chips
to the backside of granite after applying araldite to the unpolished surface of the granite to create
a surface suitable for proper bond with backing and filling the space between granite and
backing with cement slurry including adequate curing etc. complete as directed and including
rounding & polishing all exposed edges in semicircle / chamfering / or as per drawing & as
For top of dwarf walls, parapets, seat wall, planter wall etc using machine polished Granite stone of
approved colour, shade & size as per drawing laid over & including 20mm thick cement mortar1:4 (
1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm
74.3 over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints. Sq.m 689.28 2,800.00
including half round / semi circle / camfering moulding & polishing of exposed face etc complete.
Providing & laying at all floors & locations Homogeneous Full body Vitrified tile/ Glazed vitrified tile/
Anti Skid Vitrified tile double charge/ multi charge (Glossy /Matt/ Satin)/ approved manufacturers
of sizes 600 mm X 600mm / 800mm X 800mm / 1000 mm X 1000 mm size or as per approved size
and having mimimum thickness 8.5 mm or as specified by approved manufacturer tiles conforming
to IS:15622 having water absorption less than or equal to 0.08% (Group B I a), in flooring/ skirting/
dado/ cladding / staircase tread/ riser at all floors and location, heights/ levels and lead in
75 approved pattern and colour, shade laid over cement mortar bedding/ backing/ adhesive
backing, including cleaning and preparing the surface for bedding/backing, spreading the neat
cement slurry, close jointed and grouted with matching coloured readymade cement grout and
approved pigment as per manufacturer's specifications, finished to level, line, slope and plumb,
cutting of tiles, wastage, making openings / cut out if neccesary, final cleaning of surfaces, curing
etc. all as per drawings, specifications & as directed by Engineer in charge.
In flooring using Anti Skid Finish tiles of size 600 mm X 600 mm laid over 20 mm thick cement
mortar1:4 bedding (using reday mix mortar) and spreading neat cement slurry by using minimum
cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement of
about 4.50 kg/sqm over bedding,, and including Providing and laying Durafloor protector XF 3 mm
thick sheet of approved make and brand over the whole vitrified tile / stone flooring area along
75.1 with removing and cleaning the same before handing over without damaging the finished surface Sq.m 1,541.65 1,400.00
& making good the damages, if any etc and including Providing in flooring & skirting 3 mm thick
and 8.5 mm deep grout line using PVC spacers for creating true alignment and gap between
vitrified tile work, if shown in the drawing & the 3 mm spacer joints filled with approved cement
based tile grout including all labour material, wastage complete.
In dodo / skirting / cladding / sloped skirting laid over 12 mm thick CM 1:4 (1 cement : 4 sand, using
75.2 reday mix mortar) backing, including providing grooves as per drawing on top of skirting. ( Using Sq.m 2,372.16 1,400.00
AntiSkid vitrified tiles or Double charge vitrifed tiles )
Providing and laying machine cut and machine Polished Kotah stone flooring, skirting, riser, treads
at all floors, levels & location including cement mortar (using ready mix mortar) bedding / backing,
close jointed & grouted with matching cement slurry and finished to line, level, curing etc. as
76 required, including cutting of stone slab, wastage, making cut outs, wherever required, machine
polishing/ hand polishing (where machine cannot have access) and including providing and
laying 6 mm thick POP during construction period etc. complete all as per specifications, drawings
and as directed by the Engineer in charge.
In flooring with mirror polished, 25 mm minimum thickness kotah stone slab of size 600mm x 600mm /
76.1 575mm x 575mm / (and any other size and pattern as per drawing) laid over bedding of 20 mm Sq.m 2,386.02 982.83
Ready mix mortar having Cement: Sand (1:4)
Polished Kotah stone of approved colour, shade and surface finish for cladding/ dado/skirting/
/Facia/Window Sill/riser/treads with stone slabs of various sizes in pattern including 12 mm thick 1:4
cement mortar (Using ready mix mortar) backing, fixing of 6mm (approx.) size angular stone chips
to the backside of Kotah stone after applying araldite to the unpolished surface of the Kota stone
to create a surface suitable for proper bond with backing and filling the space between Kota
stone and backing with cement slurry including adequate curing etc. complete as directed and
including rounding & polishing all exposed edges in semicircle / chamfering / or as per drawing &
Providing and laying Riverwash finish Dark grey / Steel Grey /Adhunik/ Any other approved color
Granite stone flooring / Coping in required size, design and patterns, in linear as well as curvilinear
portions all complete as per the architectural drawings with 30 mm thick stone slab over 20 mm
(average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with
5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed)
77 or struck pointed as per design and drawing with white cement slurry admixed with pigment of Sq.m 18,248.80 3,451.00
matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges
and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete
as specified and as directed by the Engineer-in-Charge. Including Minimum 2 mockups for
approval, complete for finished item of work. Wax polishing is strictly not allowed.
Providing and laying Riverwash finish Dark grey / Steel Grey /Adhunik/ Any other approved color
Granite stone flooring / Coping in required size, design and patterns, in linear as well as curvilinear
portions all complete as per the architectural drawings with 18-20 mm thick stone slab over 20 mm
(average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with
5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed)
78 or struck pointed as per design and drawing with white cement slurry admixed with pigment of Sq.m 582.95 2,900.00
matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges
and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete
as specified and as directed by the Engineer-in-Charge. Including Minimum 2 mockups for
approval, complete for finished item of work. Wax polishing is strictly not allowed.
Providing and fixing Pre cast Kerb blocks of various types (Half Batter, Bull nose, Flat, offlet, Transition,
Dropper, etc,.) and size of 600x450x150mm steel mould Vaccum wet pressed for connecting roads,
pathway-prominade area and other area with true line & level, including grading, geometrical
shapes in curves, circles etc. at respective finish level etc. completed as specified in drawing and
specification. It shall be of CC- M25 grade of concrete and fitted and jointed in C:M 1:1 with
throughly curing, rendering with cement slurry, cleaning the joints neatly etc. completed as
directed by EIC. It allows to satisfy respective IS-codes for materials, manufacturing process and test
Providing and fixing 80 mm thick (min.) factory made paver blocks of specified finish (shot blasted),
approved make and colour, shade, size, shape laid in pattern manufactured with cement
concrete grade not less than M-40 and conforming to IS:15658, including providing & laying 20 mm
80 thick bedding of cement mortar (using ready mix mortar having cement: sand, 1:4) finishing to line, Sqm 9,083.61 1,400.00
level and slope, finally filling the joints with matching cement mortar and cleaning the surface etc.
complete all as per specification and as directed by the Engineer- in- Charge.
Flooring with Cobble stone of approx. Size 100x100x100 mm (thick) laid on 25 mm average thick
cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with
pigment to match the shade of the stone, laid in approved pattern, approved colors complete in
all respect as per direction of Engineer-in-charge.
Providing and fixing 60 mm thick (min.) factory made paver blocks of specified finish (shot blasted,
pneumatic compressed), approved make and colour, shade, size, shape laid in pattern
manufactured with cement concrete grade not less than M-35 and conforming to IS:15658,
82 including providing & laying 20 mm thick bedding of cement mortar (using ready mix mortar having SQm 1,019.00 1,250.00
cement: sand, 1:4) finishing to line, level and slope, finally filling the joints with matching cement
mortar and cleaning the surface etc. complete all as per specification and as directed by the
Engineer- in- Charge.
Providing & laying machine cut machine polished natural stones as mentioned for the followings for
kitchen / Basin platform topping, counter topping and facia over and including necessary cement
mortar for backing / bedding, close jointed and grouted with matching cement slurry and finished
to line, slope, level, plumb, curing etc, as required including cutting of stone slabs, wastages,
making cut outs wherever required etc all as per specifications and as directed by the Engineer in
charge. Notes : 1) Verticals, shelves, platform shall be embedded minimum 25 mm in wall/ flooring.
2) Top exposed surface on plan & exposed vertical finished face shall be measured for payment in
For kitchen / Basin platform top, Vertical support for Counter, upto 750 mm wide and maximum
length upto 1.80 m in single piece consisting machine cut machine polished 35 mm thick
cuddappah stone at bottom and mirror polished machine cut 18mm thick Jet black/ approved
Granite stone at top fixed with 47 mm thick 1:3 cement mortar (Using ready mix mortar), between
two stone slabs (Double stone slab sandwitch type) including providing cut out if any, moulding
and polishing the edges etc complete.
For kitchen platform horizontal & vertical facia upto100 mm wide machine cut machine polished
on one side 18 mm thick Jet black/ approved Granite stone fixed with epoxy resin base (Araldite
adhesive orequivalent) including round moulding and polishing the edges etc complete.
Providing and laying 30 mm thick (without pattern thickness) all type of tactile pattern stone with
textured finish as a warning stone of required size and pattern, depth of pattern shall be as per
standard of vision impaired persons (minimum 8mm above) in any colours and shades in for
outdoor floors such as footpath, atrium, terrace location etc., laid on 30mm (average) thick base
of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the
joints with white cement mixed with matching pigments etc. complete as per direction and
approval of EIC.
(RATE ONLY ITEM)
Providing & Fixing M/F Suspended Plain Gypsum Ceiling which includes 20x28x30x0.5mm Perimeter
Channel {Material-GI(IS513), YS-300Mpa, Finish-Galvanised 150GSM(IS 277)} is fixed along the
perimeter of existing wall/ partition with the help of suitable HPS - 1 (6x40) impact anchor / PVC
Anchor (6x40) at 600mm c/c for the brick wall, at 600mm centres. 25x10x0.5mm Ceiling Angle
{Material-GI(IS513), YS-300Mpa, Finish-Galvanised 150GSM(IS 277)} is suspended at up to 1.5m height
by fixing it to the 27x37x25x1.6mm Gyproc® soffit clit {Material-GI(IS513), YS-300Mpa, Finish-
Galvanised 150GSM(IS 277)} with Soffit Cleat and or Rawl Plug- Ø8x45mm {Material-IS 513 CR2
grade, Zinc coating (7 to 8 microns)Pull Out Load- 7.5kN for M30 concrete grade} creating 1220mm
x 1220mm grid. 15x45x15x0.9mm Intermediate channel {Material-GI(IS513), YS-300Mpa, Finish-
Galvanised 150GSM(IS 277)} is fixed to the 25x10x0.5mm Ceiling Angle with M6 x 12mm Hex Bolt &
Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 metal
to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.}
The 80x26x0.5mm Ceiling Section {Material-GI(IS513),YS-300Mpa,Finish-Galvanised 150GSM(IS 277)} is
then fixed to the 15x45x15x0.9mm Intermediate Channel {MaterialGI(IS513),YS-300Mpa,Finish-
85 Galvanised 150GSM(IS 277)} with the help of Ø 2.64mm Connecting Clip {Material-High carbon Sqm 995.40 978.00
spring steel wire (BS970Gr.En42)-46-48HRC,Finish-Zinc plating 4-6 micron} and in direction
perpendicular to the Intermediate channel at 457mm c/c. Single-layer of 12.5mm thick Plain
(conforming to IS 2095 Part 1: 2011, ISI Mark Certified, International EPD Verified) of size 1219 x
1829mm is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-
ISO 7049/50, Finish-Case hardened Grey Phosphating as per JIS G3507-1} standard at 230mm
centres.Gypsum Board to be certified class 1 under BS-476 Part 5,6, & 7 & certified GreenPro by CII.
Finally, square and tapered edges of the boards are to be jointed and finished to have a flush look
which includes filling and finishing with Jointing Compound & Joint Paper tape. Serrated steel
section has an effective thickness of 2T (2xdepth), better load carrying capacity, enhanced screw
retention, Improved acoustic performance & fire resistance as compared to plain steel section. All
metal components are Design Patented in India (325062). Vendor to submit MTC, material
inspection report and/or performance certificate for the system. If required trap door also provided
as per drawing is included. No Extra payment shall be made for the Trap Door.
Providing and fixing tiled false ceiling of size (600x600)mm in true horizontal level suspended on inter
locking metal grid of hot dipped galvanized steel sections. It consists of main "T" runner of size
24x32x0.3x3600mm, cross "T" of size 24x25x0.3x1200mm, secondary cross "T" of size 24x25x0.3x600mm
and PPGI wall angle of size 24x24x0.4x3000mm. Bottom exposed capping of width 24 mm of all T-
sections shall be of 0.25mm thick PPGI. PPGI wall angle 24x24x0.4x3000mm {Material-GI(IS513), YS-
280Mpa, Finish-Galvanised 90GSM (IS277)} is fixed along the perimeter of the ceiling to Walls,
partitions or columns etc., with wooden screws at 300mm centers or Hilti HPS 6x40mm placed at
mm c/c. soffit cleat 27x37x25x1.6mm {GI(IS513) YS-260Mpa, Finish-Galvanised 120GSM (IS277)} is
fixed with Rawl Plug- Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating (7 to 8 microns) pull out
load- 6.8kN for M30 concrete grade} creating (1200x1200)mm grid. Main-T runners
24x32x0.3x3600mm are then suspended at 1200mm c/c from ceiling using 4mm zinc electroplated
butterfly level clips of size 85x30x0.8mm spaced at maximum 1200mm center to center along main T
and not more than 150mm from spliced joints. The last hanger at the end of each main runner
86 should not be greater than 600mm from the adjacent wall. 24x25x0.3x1200mm cross T {Material- Sqm 813.80 1,144.25
GI(IS513),YS-280Mpa, Finish-Galvanised 90GSM (IS277)} is interlocked between the main T at 600mm
center to center to form a grid of 1200x600 mm and then secondary cross “T" 24x25x0.3x600mm
{Material-GI(IS513), YS-280Mpa, Finish-Galvanised 90GSM(IS277)} is then interlocked at middle of the
(1200x600)mm grid to form grids of (600x600)mm. Cross Tees at the ends having length more than
600mm are to be supported independently.Finally 12.5mm thick square edge Gypsum tile (meets
requirement of specification mentioned under DAR no. 12.52.3 in Delhi Schedule of rates (DSR)), of
size 595x595mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS
part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron
metalized polyester on the back side with all edges sealed with the face side PVC film which goes
around and wraps the edges and is bonded to the edges, so as to make the tile a completely
sealed unit, is placed in the grid.
Providing and Fixing Metal Frame Suspended Ceiling which includes Perimeter Channel of 0.50mm
thick, having one flange of 20mm and another flange of 30mm and a web of 27mm, fixed along
the perimeter of ceiling, screw fixed to wall/ partitions with the help of nylon sleeves and steel
screws. Then suspending Intermediate Channel of 0.90mm thick, web of 45mm with two equal
flanges of 15mm each from the soffit at 900mm centres with ceiling angle of 0.50mm thick, having
one flange of 10mm and another flange of 25mm, fixed to soffit with the help of soffit cleat (27 x
87 x 25 x 1.6mm), Ø12 x 45mm Metal Anchor Fasteners (Rawl Plugs) and M6 Bolt Nut (6 x 12mm). Ceiling
Section of 0.50mm thick, having a web of 53mm (80mm overall width of the profile) with two equal
flanges of 26mm each and equal lips of 10.5mm each are then fixed to the Intermediate Channel
and in direction perpendicular to the Intermediate Channel at 488mm c/c(max) with GI
connecting clips (wire diameter of 2.64mm). Additional members shall also be provided to support
the plank joints, as per site conditions.
6mm Fibre Cement Board (conforming to IS 14862: Type B- Category 3; Density >1200Kg/m3; MOR at
EMC >10MPa and MOR in Wet Condition >7MPa; with Fire property classification as non-
combustible, Class A and A2-s1-d0, when tested in accordance to BS 476, ASTM E84 - 18B and
EN13501: Part 1, respectively) and 9mm Everest Heavy Duty Fibre Cement Board (conforming to IS
14862; Type A - Category 4 Density >1450Kg/m3, MOR in wet condition >14MPa, Class A and A1,
when tested in accordance to BS 476, ASTM E84 - 18B and EN1350: Part 1, respectively), as substrate
and finished ceiling board, shall then be screw fixed to the bottom of the ceiling section with 25mm
and 35mm Everest self-tapping self-drilling countersunk screws, respectively. Screw fixing of the
substrate board and the Heavy Duty Board shall be at 300mm c/c (max). The joints of the boards
shall be staggered to avoid through joints. The exposed Everest Heavy Duty Fibre Cement Board
shall be screw fixed with desired grove finish as per the specification.
Providing and Fixing in position, Acoustic micro perforated metal ceiling clouds made of aluminium
Sheet (exposed side powder-coated) of size as per drawing have NRC better than 0.85 on both
side, Micro holes dia. 0.04 - 0.08mm, water resistant, no back material, warranty 25 years,
electromagnetic immunity – 40% than general aluminium, dust proof, incombustibility Class A, Acid/
Alkali resist water tolerant, Non-toxic recyclable install with required hanging system. All material to
88 be approved by the architect & EIC prior to installation. The design, color and shape of the panel Sqm 1,350.00 5,277.55
shall be approved by the architect & EIC. Complete with hanging arrangement to suspend from
the main ceiling/slab. Installation system as per vendor specification and to be approved by
architect & EIC prior to installation. All Makes and models of all items/samples should be approved
by the Architect and Engineer in charge prior to the installation.
DOORS & WINDOWS
89 Aluminium Framed Doors with Floor Spring
Design, Fabrication, Supply, Installation, Testing, Protection, Cleaning & Handover Single shutter
aluminium framed door opening outward system to withstand the design wind pressure. The system
shall have a Wool pile weather sealing at perifry of Door Frame. The profile system is in line with the
tender drawing & minimum of 1.8 mm thickness.
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover Single leaf double swing
Frame door made out of 12mm thick fully tempered (FT) glass with PT series patch fittings, Door
lock and BTS 80, 90 deg with EN 1-4 spring capacity floor spring. Floor spring covers shall be SS satin
finish, as per the Architect's approved shop drawings.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard
from approved extruder. The structural profiles shall have minimum 1.8mm wall thickness. All the
visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 -
80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum
chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all Design & shop drawing approval from architect & consultant.
Aluminium framed door system with glass
Quote rate for complete system as mentioned above under item (B).
Aluminium Framed Single Swing Doors:- Double Shutter (Size :- 1610 mm (W) x 2400mm (H) NOS 18.00 51,850.00
Aluminium Framed Single Swing Doors:- Double Shutter (Size :- 1425 mm (W) x 2400mm (H) NOS 18.00 46,200.00
Aluminium Framed Single Swing Doors:- Double Shutter (Size :- 1500 mm (W) x 2400mm (H) NOS 36.00 48,600.00
Vision Glass:- 12mm Thk.:- Providing and fixing glass:-
Glass:-12mm thk. (12mm thk. Clear tempered glass) (As per Client / Architect Approval sample). Sqm
90 Spider Canopy with Laminated glass on SS Support Above Door.
Shop Drawing, Fabrication, Supply, Installation, Testing, Protection, Cleaning & Handover of SS316
Support canopy with spider system of DORMA / OZONE custom Shop Drawing with stand the Shop
Drawing, wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times
Shop Drawing, wind pressure without any failure) with weather sealants, backer rod, Bracketing
system with Aluminium Alloy of 6005 T5 brackets Shop Drawing,ed to accommodate three
dimensional movements with serrated plate and serrated washers, SS 316 grade fasteners & Anchor
Fasteners, nylon separators to prevent bi-metallic contacts, all complete required to perform as per
specification and drawing in conjunction with BOQ.All SS members-Grade 316 With have satin finish
inline with architect requirement.
The stainless steel spider system of Grade 316, supported on SS structure, all inline with the tender
drgs. All the weather sealants shall be non staining of approved make, Stainless steel spider system
of grade 316 with Articulated bolt assembly, with SS 316 grade fasteners and anchor bolts of
approved make, Teflon/ nylon bushes & separators to prevent bi-metallic contacts, all in complete
required to perform as per specification and drawing in conjunction with BOQ.
Shop Drawing, Fabrication, Supply and install required prefabricated grid on to the SS Steel portal
with full Welded of as recommended by approved supplier to support given Shop Drawing, loads.
The brackets shall have provision movement to accommodate the construction tolerances . Use of
SS316 brackets with washers to prevent wind direction movement after final position.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
90.1 Quote rate as mentioned above under item (D) with Laminated Glass.
17.52mm Laminated glass :- (8mm Clear FT Glass + 1.52mm Clear SGP Kuraray Lamination + 8mm 19.00 13,500.00
Clear FT Glass)
90.2 Quote rate for complete SS works as mentioned in item (D). Ton 19.00 1,80,000.00
91 Aluminium Framed Doors with AHPL and Floor Spring.
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover Single leaf, double swing
Aluminium Frame door System, The system shall have a wool pile weather sealing all side door
frames. The profile system is in line with the tender drawing & minimum of 1.8 mm thickness. Patch
fittings, Door lock and BTS 80, 90 deg with EN 1-4 spring capacity floor spring. Floor spring covers
shall be SS satin finish, as per the Architect's approved shop drawings.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard
from approved extruder. The structural profiles shall have minimum 1.8mm wall thickness. All the
visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 -
80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum
chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all Design & shop drawing approval from architect & consultant.
Aluminium framed door system with glass.
91.1 Quote rate for complete system as mentioned above under item (E)
Aluminium HMPS Framed Single Swing Doors:- Double Shutter (Size :- 1000mm (W) x 2400mm (H) NOS 18.00 32,500.00
Aluminium HMPS Framed Single Swing Doors:- Double Shutter (Size :- 1000mm (W) x 2100mm (H) NOS 72.00 28,500.00
Aluminium HMPS Framed Single Swing Doors:- Double Shutter (Size :- 1200mm (W) x 2400mm (H) NOS 12.00 39,000.00
Quote rate for complete system as mentioned above under (E) Including 6mm thick (AHPL)
aluminium high-pressure laminate of a thick fire-retardant (FR) grade mineral-filled thermoplastic
inorganic core of grade B sandwiched between two thin coil PVDF coated aluminium sheets (Top i.e.
face #1 & rear, i.e. face #2) of Alloy Grade 3003 and H-16 temper and minimum thickness of 0.5mm
each as specified in the nomenclature of item. The HPL fire retardant core of B grade
Supplying & fixing in position the following type solid core block board flush door shutter (Single/
double leaf) with commercial ply facing / prelamination on both sides conforming to IS 2202 (Part-
1) of approved make & brand with external / internal type second class teak wood lipping alround
of required width and depth (20 minimum thickness all around) of shutter as per IS/as specified,
fixing shutters in position to HMPS door frames/ wooden frames/ granite frame works (door frames
92 shall be paid separately under relevant item) at all floors by cutting/ planing if necessary including
labour for fixing of the fittings & fixtures as per drawing with wooden packing pieces if necessary
(but excluding the cost of fittings and fixtures with SS screws which shall be paid separately under
relevant item), including view panel wherever required as per drawing, finishing as specified all as
per specifications, drawings and as directed by Engineer In Charge.
30 mm thick flush door shutter (for shaft doors), With 1.0 mm thick decorative laminate sheet of
92.1 approved colour, pattern & shade fixed on one face of shutter and 1.0 mm thick white / off white Sqm 459.00 3,100.00
lamination on another face.
Providing & fixing Hollow Metal Pressed steel (HMPS) door frames of following profile fabricated out
of 1.60 mm thick G.I sheet of coating (Class VIII of zinc coating) 120 gram/sqm, manufactured by
Sail / Lloyds/ Jindal or equivalent of profiles / size generally conforming to IS 4351-2003 with suitable
one/two set rebates for fixing shutters and also rebate suitable for fixing fixed glazing including hole
for self tapping screws wherever shown in the drawing, each frame to contain hinge jamb, lock
jamb and head all rigidly fixed together with welded /mechanical joints with back plates /angles
to correct shape & angles including providing and fixing base ties with GI channel 50x25mm,
1.25mm thick suitable section to suit floor thickness / angle thresholds with MS angle 25x25x3mm,
6nos. of adjustable lugs per frame, providing and welding of 40x40x5mm,150mm long angle cleats
93 for hinges with necessary tapped holes for fixing counter sunk headed machine screws to suit rmt 1,317.96 900.00
heavy duty oxidised / stainless steel hinges of size 125mm x 65mm x 2.8mm/125mm x 76mm x
2.80mm/ 100mm x59mm x2.6mm/75mm x 48mm x 2.45mm or shop type welding and self taping
screw for fixing hinges/ piano hinges etc.
and finishing the same to smooth etc. (but excluding the cost of hinges which shall be paid under
the relevant item) including providing each door frame with necessary lock strike plates, mortar
guards, buffers, bushes etc. required for tower bolt/ baby latches, tadis, safety chains, aldrops etc
including fixing the frame to brickwork/ concrete work with necessary PCCor bolted/ screwed to
concrete work, painting a shop coat of polyurethane paint including etching the surface with ETCH
including painting the exposed surfaces with two coats of synthetic enamel paint of approved
make and colour over a coat of red oxide/ zinc chromate primer and painting the unexposed
surfaces with two coats of anti corrosive bituminous paint, after rectifying the damaged PU primer
due to transport including filling the hollows of door frame with C.C.1:2:4 using 12 mm size
downgraded stone aggregate, curing, finishing etc. all complete as per drawings, specifications
and as directed by Engineer in charge.
Note: The quoted rate shall include cost of base tie / angle and all accessories mentioned in the
item description except iron mongeries (i.e. fittings and fixtures with wood and machine/ self taped
screwsas required, which shall be measured and paid separately under relevant item.)
Profile 90mm x 60 mm with single rebate for doors.
Steel Fire Rated Doors with HMPS Steel Frames. Fire Resistant Door (FRD) assembly having
minutes (2 hr) Fire rating, Metallic and conforming to IS 3614:2021 (Single / Double lef Shutter)
Providing and fixing factory made Fire rated door assembly of galvanised Iron Steel door frame with
mettallic single / double leaf door shutter with accessories, the entire door assembly including
shutter, frame and fittings shall be confirming to 1200 minutes (2 hr) fire rating as per IS
Frame:- The door frame shall be made of minimum 1.20 mm thick GI Sheet with minimum 120 GSM
94 coating as per IS:277. The frame shall be of grooved profile of minimum size 90 × 60 mm with inbuilt Sq.m 453.60 20,200.00
sealing system to take appropriate fire rated smoke seal. Frame shall be provided with appropriate
reinforcement suitable for hardware and flush fixing. Frames shall be provided with stiffener pieces
and mitred cut joints (self tab/screwed assembled at site). Fire rated EPDM smoke seal, confirming
to IS 3614 : 2021 shall be fixed within the inbuilt groove or stuck with adhesive on the entire
perimeter of the frame.
Door frames shall be fixed to all round the opening with minimum 8 mm dia CSK headed fastner of
minimum 80 mm long with 8mm dia Polyamide sleeves @ 3 Nos at each side.
Finishing: Frame to be factory finished with polyester powder coating of minimum thickness of
microns (500 hrs salt spray test) of approved colour and shade all complete as per manufacturer’s
Specification and direction of the engineer in charge.
Door Shutter: The factory made fire resistant mettallic door leaf shall be minimum 60 mm thick fully
flush double skin step design door, insulated with or without vision. Door leaf shall be manufactured
from 1.2 mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door
should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall not
be less than be 120kg/m3 high density mineral wool insulation material. Intumescent seals 15 x
1.5mm to be provided. All ISI labelled doors shall be factory prepped for receiving appropriate
hardware and provided with necessary reinforcement for hinges, locks, and door closers panic bar
etc. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated
astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite
wherever applicable shall be maximum 200 x 450mm with clear borosilicate fire rated glass of 6mm.
Glass shall be fixed with suitable gasket and with clip-on arrangement.
The door leaf shall be factory finished with polyester powder coating of minimum thickness of
microns (500 hours of salt spray test) of approved colour and shade all complete as per
manufacture's Specification and as per the directions of Engineer - in- charge.
Accessories Hardware: Fire doorset shall include all accessories like, Fire rated SS 304 grade ball
bearing type hinges of minimum size 100 mm ×75 mm × 3 mm one (3 numbers per leaf upto
mm height or as per test evidence), one number fire rated SS mortise lock with handle, fire rated
Installation: Post installation hollow space within door frame shall be filled with fire rated self-
extinguishing type polyurethane foam. Rate shall include for supply and installation of complete
door assembly, by the manufacturer. (All mechanical and functional hardware like hinges, lever
handles, door closers with 120 minutes fire rating are to be used on doors and must conform to
relevant IS 3614 :
all as per manufacturer's specification and providing Fire Resistant certification (manufacturing &
installation) as required by local fire statutory authority shall be furnished by manufacturer of Door
assembly (Frame, Shutter, fitting) and all cutting/ planning if necessary, labour for fixing the fittings
and fixtures with suitable packing if necessary including providing and fixing 120 minutes (2 hr) fire
rated approved powder coated steel door set etc. all complete all as per specifications, drawings
& as directed by Engineer in charge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and
manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor
95 spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all SQM 1.00 4,500.00
complete as per direction of Engineer-in-charge.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer of
approved make conforming to IS: 3564 with ISI mark including necessary accessories and screws
96 etc for fixing with alumnium/ wooden/ steel doors with necessary bolts & nuts, labour, scaffolding NOS 207.00 1,250.00
etc complete all as per specifications and as directed by the Engineer-in-charge.
Providing, fixing & Supplying at site of work approved quality and manufacturer, confirmed &
marked with relevant IS (wherever applicable), Stainless steel (SS-304) fittings, fixtures and fastenings
along with Stainless steel screws/concealed SS screws, bolts, nuts, washers,wooden packing pieces
97 if necessary etc.and other accessories etc complete all as per specifications and as directed by NOS 621.00 220.00
the Engineer-in-Charge.
SS But hinges (Heavy Weight) of size (100 X 75 X 3.0 mm) , ball bearing type, (Two / Three leaf
Providing, fixing & Supplying at site of work approved quality and manufacturer, confirmed &
marked with relevant IS (wherever applicable), Stainless steel (SS-304) fittings, fixtures and fastenings
along with Stainless steel screws/concealed SS screws, bolts, nuts, washers,wooden packing pieces
if necessary etc.and other accessories etc complete all as per specifications and as directed by
the Engineer-in-Charge.
S. S. Tower bolt 300 mm long x 12 mm barrel
Providing, supplying, fixing approved make back to back stainless steel Handle-450 mm long (Set
including a pair of handles), of minimum 25 mm dia, including accessories for fixing it to glass,
99 aluminium, wood shutter, brackets etc.complete as directed by EIC. (Note:- Cost is for one set NOS 174.00 3,400.00
consists of two nos of handles to fix on shutter both side (Inside & Outside))
GRAB HANDLE FOR ADA TOILETS:
Providing & fixing 25 mm diameter (1.5mm thick) SS 304 satin (brush) finish Grab handle for disabled
toilet door of 600mm long of approved make with necessary SS 304 grade screws etc. complete as
per drawing as sample approved by Engineer-in-charge
Providing & Fixing 6- lever Mortice lock of chromium plated SS-304 parts & body of approved brand
& make, 200 mm Mortice latch & lock (without Handle Set) Lock Body CK mortice lock with
chromium plated SS screws, with duplicate keys etc. lock shall be fitted as per manufacturer
specification and as directed by Engineer in charge.
Providing and fixing Mortise shaft dead bolt with key (Alen Key lock) with 57mm backset and 25mm
102 square forend in stainless steel satin finish of approved make including all labour, material etc NOS 207.00 400.00
complete all as per specifications and as directed by the Engineer-in-Charge.
Providing, supplying, fixing glass to glass 6 lever SS patch lock (Round type) of approved make on
103 glass for doors complete as per drawing. Frameless Swing Doors (Patch Fitting Doors) NOS 1.00 750.00
Providing and fixing double action hydraulic floor spring of approved brand and manufacture
having ISI mark as IS : 6315, having brand logo embossed on the body / plate with double spring
mechanism for doors, including cost of cutting floors, embedding in floors as required and making
good the same matching to the existing floor finishing and having minimum 1.25 mm thickness
stainless steel cover plates with brass pivot and single piece M.S. sheet outer box with slide plate,
and other accessories required for the works to facilitate smooth operation of the door shutter etc
complete all as per specifications and as directed by the Engineer-in-charge.
Sliding Windows: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and
handing over the Sliding window system, at all levels, locations, floors as per approved drawings
including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all
as per specifications, drawings and as directed by the Engineer-in-Charge.
The Sliding Window system shall with stand the wind pressure of confirming to IS -875 part III. The
sliding window system shall have SS-304 grade mesh Net shutter panel, drainage gutter profile at
bottom track, wool pile with film for weather protection and complete sir sealing. The shutter
engagement shall be minimum of 15 mm at top and bottom track to ensure stability under
deflection of vertical mullions. Including providing & fixing ball bearing rollers smooth movement of
shutters, flush type lock with manual opeartion, microwave cured EPDM gasket, non staining
weather sealant, SS-304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for
aluminium sliding windows sliding as per drawing of approved manufactures with extruded sections
of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in
the drawing, for frames and shutters [including wastages if any] conforming to relevant I.S
specifications, with all approved shade & colour anodised aluminium fittings and accessories,
locking arrangements, 2 / 3 rollers with ball bearings for sliding shutters of approved quality all as
shown in the drawing, including providing and fixing aluminium channel beading / glazing clips
fixed with necessary matching anodised screws, grouting the gap with thermocole & polysulphide
sealant etc. all complete generally as per drawings, specifications etc., all as directed by Engineer
105.1 in charge, but excluding the cost of glazing, which will be paid separately. (The aluminium system KG 30.00 620.00
consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN
standards from approved make and manufacturer.The aluminium sections shall have approved
shade and colour super durable powder coating with minimum 50 micron thickness. The non visible
aluminium sections shall have approved chromatizing treatment. {The weight of extruded
aluminium sections only will be mesured for payment}). The quoted rate shall be inclusive for
providing & fixing built in handle with locking nib/hook, dummy handle, SS locking closure plate (on
frame), adjustable single roller, nylon roller, shutter end PVC cap, anti dust plugs, screw hole cap,
drain cap, wool pile etc of approved make and design as per drawings.
Providing and fixing following type of approved quality glass panes for aluminium sliding windows,
of approved manufacturer and fixing with aluminium frame work including providing and fixing
with 2 way EPDM gasketing , to ensure water and air tightness and neoprene cushions/ gasket
accommadated in grooves, necessary SS-304 screws etc all complete generally as per drawings
105.2 specifications and as directed by the Engineer-in-charge. Sqm 10.00 1,847.46
Note:- Only clear opening of glass shall be measured for payment.
( 6 mm thick Single Glass Unit (SGU) using heat strengthened (HS) clear float glass of M/s. Saint
Gobain ET/ST series or approved equivalent)
Providing & fixing stainless steel work for pipe hand rail at staircase, Entrance Ramp and other
stainless works such as spool pieces, pipe sleeves etc, at all floors, levels & location conforming to SS-
304 grade of steel preferably schedule-10, using SS pipe in horizontal at top, vertical, inclined
including solid pipes as per drawing or as per pattern & design approved by EIC and including
necessary S.S bend, tees, Embeded plates, nuts, SS bolt,necessary welding, anchoring with SS
106 anchor fastner of M/s Hilti, grinding, buffing, polishing and fixing in concrete / wall with S.S lugs, KG 17,289.41 650.00
making pockets, concreting, making good the surfaces etc. as per specifications, drawings and as
directed by Engineer-in-Charge. ( Note:- For payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
107 Frameless Glass Railing
Design, Fabrication, Supply, Installation, Testing, Protection, Cleaning & Handover 1200mm height
glass (Above RCC ) Railing designed to with stand the wind pressure confirming IS 875 Part III and
Live load of 105 Kg/ m uniformly distributed load as per IS 875 Part II.
The system shall be support the glass at bottom continuous U-channel fixed on the finished floor
level and vertical glass to glass open joint with top Alum. Rail. 100mm Min. Glass In-build in the U-
Channel. The weather sealant of approved make, baker rod, SS 316 grade fasteners & hard setting
blocks of EPDM, all in complete required to perform as per specification and drawing in
conjunction with BOQ. Complete system shall be warranted for minimum 10 yrs against design &
workmanship defects.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard
from approved extruder. All visible surfaces shall have Anodized finish with minimum 22 micron.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
107.1 Quote rate for complete system as mentioned above under (C). Including glass For Straight Railing.
RAILING GLASS : 17.52mm Laminated glass (8 mm Clear HS Glass + 1.52mm thk SGP Kuraray
Lamination + 8mm thk Clear HS Glass)
107.2 Quote rate for complete system as mentioned above under (C). Including glass For Curved Railing.
RAILING GLASS : 17.52mm Laminated glass (8 mm Clear HS Glass + 1.52mm thk SGP Kuraray
Lamination + 8mm thk Clear HS Glass)
Fabricating, supply and erecting in position Standard Structural steel sections conforming to IS
for all structural steel works using ISMB, ISA, ISMC, MS plate, flat, square bars, pipe, square pipe ,etc.
including welding, cutting, wastage, etc. complete. The rate is inclusive of welding road, supply &
fixing of correct size nut, bolts, washers, paint, with all contractor's materials, labour, tools & plants,
in bolted / welded construction as directed by Engineer-in-Charge. Anticorrosive paint must be
applied before applied any paint. The rate shall inclusive of providing and applying Epoxy Coating
108 of approved shade, brand and manufacture on new structural steel work with one coat of 30 KG 30,000.00 117.35
micron (DFT) of Epilux 4 Zinc Rich primer of Berger Paint India Ltd or equivalent as primer and Two
coat each of 35 micron (DFT) of Epilux 84 High Gloss CR enamel of Berger Paint India Ltd or
equivalent at all levels. (Total DFT is 30+35+35=100 microns). The waste cut pieces shall not be
included in the paying quantity. The work shall be done as per drawing and specification. The work
shall be carried out as per IS:800, IS:816 with its latest amendments.
109 Sleek Curtain wall system With Fins At (Ground To Second Floor)
Design, Fabrication, Supply, Installation, Testing, protection, cleaning & handover of Conventional
toggle curtainwall Sleek Blick / Lilli / Reynaers & VS1 system designed to withstand the wind
pressure of confirming to IS-875 part III. (The system must pass the proof test at 1.5 times the design
wind pressure without any failure). The profile system is based on capped curtainwall design and
glass is held all around by mechanical pressure plate and cap with microwave cured EPDM
gaskets in all four sides of glazing, with necessary brackets of Aluminium alloy of 6005 T5 / MS with
HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load
movement, Anchor Fasteners, screws and fasteners with non staining weather sealant and
Aluminium flashing sealed all around parameter inside and outside to seal the gaps between
curtain wall and the building structure all complete required to perform as per specification and
drawing in conjunction with BOQ.
The system design shall be based on Open joint system & design shall include pressure equalization
with minimum 2 barrier gaskets for improved weather performance, drainage at all floor levels,
spandrel panel shall have pressure release slots on vertical side of profile system to avoid
condensation. Transom shall be overlap with mullion to have proper drainage to mullion. The
design to accommodate building movements, thermal expansions & the seismic movements. The
system shall be designed considering surface temperatures of 80-90 deg Cel & temperature
differential of 25 deg cel without creating excess stress in the system. All metal joints in the wet area
shall be small joint sealant applied to ensure water tightness.
The system shall be designed of floor height units spanning between the floors with Dead load &
wind load brackets with provision to accommodate movement at all floor levels and at every grid
panel horizontally. The system shall lbe designed to accommodate vision/spandrel panel. The
system shall accommodate an openable panel as per the architectural requirements in the system.
All fixed vision glass and openable shall look similar in the elevation. Aluminium Edge Guard with
black Anodised shall be fixed at all vertical & Horizontal grooves. Each glass panel shall be
supported for dead load at the bottom of the glass with black anodised glass retainers, two per
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings
shall be provided continuously with the required GI / Aluminium sheet. Internal & External concelled
Flashings shall be 1.0mm thick GI sheet. All exposed flashing shall be 1.5mm thick. Aluminium sheet
with SDF coated, matching with external Aluminium profiles.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard
from an approved extruder. All the visible surfaces shall have high Durability (Akzonobel) / Super
durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non-visible
aluminium surfaces shall have a minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. .
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
a.1 Sleek Curtain wall system
Quote rate for complete system as mentioned above under (A) Sqm 9,856.87 11,000.00
Vision Glass Straight: 19mm Thk. Sentry laminated glass providing & fixing the vision glass on the
8mm Thk. Clear HS Glass +3mm PVB Lamination + 8mm Thk.Reflective ET Series HS Glass (As per
Client / Architect Approval sample)
Vision Glass Curved : 19mm Thk. Laminated Glass Providing & fixing the vision glass on the system
8mm Thk. Clear HS Glass + 3mm PVB Lamination + 8mm Thk.Reflective ET Series HS Glass (As per
Client / Architect Approval sample)
a.2 Operable vent : Extra over a.1
Providing and fixing Top Hung Open Out (operable) vent accessories with heavy-duty self-
balancing stainless steel friction hinges with provision to hold open at 250 mm. Vent locking
accessories with a cremone lock and handle with a 6-point locking mechanism to keep the vent
weather-tight. The vent shall comprise of Aluminium outer frame with drainage provisions and
crimped corners, and a shutter frame with Euro grooves and crimped corners; all joints shall be
sealed with small joint sealant. The outer frame is fixed to the unitised profile system with necessary Sqm 216.00 6,500.00
SS screws and weather sealant applied at the outside and inside of the profile duly Super Durable
Powder coating finish of 60-80 micron thickness as per the approved shade by the Architect. The
stepped glass design vent shall have ceramic frit in black / colour to match the glass at the portion
of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing.
Providing and fixing 5mm thick various size of glass mirror on wall over 6mm thick plywood or plastic
fibre base, round up mirror edge and corner from the approved make as per selection of architect
and engineer in charge having basic rate as following - (Basic sqmt rate: 1940 Rs.)
110 (This item shall be procured / provided from selection as per approved make list, data sheet and Sqm 105.46 4,496.00
technical specifications.)
(Selection as per soft furniture data sheet)
Providing and fixing at all levels, locations and at all floors, 50 mm thick Reinforced precast Jali in
C.C 1:2:4 of approved pattern, design and shape including pointing and proper joining of junctions
111 with ready mix cement mortar including all formwork, reinforcement, finishing the surface, curing, Sqm 705.08 1,600.00
scaffolding, hoisting, erecting & fixing in position etc complete all as per specifications and as
directed by EIC.
Providing and installing the speed breaker of PVC material with size of 250x350x50mm and/or
250x450x60mm on the cement concrete surface of the road with labour and all the necessary
accessories, hexacore design, oil resistance, chemical resistance, water resistance, UV stabilized,
non fading colors, with reflector tape.
Providing and fixing shock absorbing rubber corner guard having size 115x115mm, height 1000mm
and thickness 10mm, manufactured from flexible high strength rubber, embedded with highly
reflective weather resistance reflective material, tamper resistant, with black base and tape color
options in yellow, white and lime.
Road marking with hot applied thermoplastic paints with reflectorising glass beads on bitumen
surface providing and laying a hot applied thermoplastic compound 2.5 mm thick including
reflectorising glass beads @ 250gms per sqm area, thickness of 2.5mm is excluding of surface
applied glass beds as per IRC:35-2015. The finished surface to be level, uniform and free from
streaks and holes. zebra patta /bump patta lane/center line/ edge line/cut patta. The white color
marking should provide luminance coefficient on cement road shall be min 130 mcd/m2/lux and
Asphalt road shall be min 100 mcd/m2/lux during the service life during the day time. The marking
should meet the performance criteria for night time reflectivity, wet reflectivity and skid resistance
as mentioned in the section-15 of IRC 35-2015. Warranty for the Retro reflectivity should be two
Providing and installing outdoor convex mirror of size 600mm diameter, 130 degree viewing angle,
polycarbonate construction, vandal resistant with and without MS pole.
Supply, Installation, Testing, Commissioning of- Electromechanical boom barrier with a 3-meter
boom arm for car and 1.5mtr boom arm for bike lane, And a 0.6-second opening/closing time. Key
features include a corrosion-resistant powder-coated cabinet, die-cast aluminium motor with
thermal radiating and cooling fan, and 100% duty cycle with an MTBF of 10 million cycles. Safety
features include manual release, obstacle reversal, auto-closing, and support for external photocell
and vehicle loop detectors. The system operates on 220V/110V at 50/60Hz, with IP54 protection, a
motor torque of 300Nm, and a working temperature range of 0°C to 65°C.
Supply, Installation, Testing, Commissioning of-Portable Cabin for the pay booth will be a compact,
mobile structure with dimensions of 6 feet length, 4 feet width, and 8 feet height. It will feature a
robust MS square pipe frame, sliding aluminium powder-coated windows with tinted glass, and a
rainwater protection guard. Insulated with 50mm glass wool for both the ceiling and side walls, the
cabin will be electrically equipped with AC 220-240V fittings, including sockets, tube lights, and a
wall fan. A wooden counter with locked drawers for storage will be included, along with safety
features such as earthing and synthetic primer/epoxy paint finishes. The cabin will also have special
lifting hooks, vinyl flooring, along with 1-ton Split Air Conditioning unit fitted (1075 Watt) and all
necessary accessories for installation and commissioning.
Providing and fixing in Stainless steel Floor Mounted Dustbin with dimensions and design as per
Architect selection, in SS 316, Dual bins with 50 liters each having Matt / Mirror Finish including
118 required foundation, anchor bolts and fixing details etc. completed as directed by EIC. Including NOS 25.00 15,208.00
Minimum 2 mockups for approval complete as per instruction of engineer in charge.
SS Support For Green Wall With SS String
Design, Fabrication, Supply, Installation, Testing, Protection, Cleaning & Handover of SS 304 grade
provision support for green wall as per design intent. The entire assembly shall be fixed on SS
grade Support grid as per design drawings. The brackets shall be SS 304 grade fixed to the building
structure with necessary fasteners & anchor bolts in SS
Prefabricated grid SS 304 grade Support are fixed on to the RCC and concrete masonry walls with
SS 316 anchor bolts as recommended by approved supplier to support given design loads. The
brackets shall have provision movement to accommodate the construction tolerances with +
119 35mm plumb in case of RCC structure and + 20mm plumb in case of steel structure.
Provision main SS 304 grade support for vertical Garden system shall be installed in line with
All Material Make - Jacob.
All shade approval shall be as per Architect's & EIC Approval.
The quote rate shall include all design, engineering & shop drawing approval from architect,
consultant & EIC.
Rate as mentioned above under above item With 4mm thick. SS 304 grade String Vertical &
Horizontal 900 c/c or as mentioned in drawings.
Entry Exit Totem
Providing and fixing at location a signs I sign -display signage with 100 mm depth Aluminium
extrusion Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is
70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-
microns) Flatness & Twist of profile within 1.5 mm / meter length, with 10 years warranty under
normal working conditions. Media accomodation depth of 8 mm avialble for pasting on dual lock
or strong two way adhesive. M.S fabrication slot of 65 mm depth for internal M.S structure.Media
upto 6 mm thickness can be pasted or mounted with help of dual lock tape .assembled totem can
120 be edge lite with help of edge lite modules or back lite with help of back lite modules.CosignTotem NOS 2.00 97,750.00
profiles screwed fixed with internal M.S structure are installed at site in plumb and level at specified
location as per drawing to the satisfaction of the engineer-in-charge. Graphics to be done using
printed retro reflective material.
Size - 750mm * 1800mm * 100mm
Mounting Type - Ground/RCC
Signage - Lite/Nonlite (As per approved drawing)
Speed Limit/Info sign
Providing and fixing at location a sign using Modular Aluminium extrusions (Alloy 6060 as per
European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin
aluminiumhomogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns)
International standards, with10 years warranty under normal working conditions. Silver anodised
aluminium 80 x 80 mm outer size (octagonal shaped) cover list anodised profile to hide screw
fittings of pole and M.S structure . M.S structure of 'C' channel made by joining two 'L' angles
35x35x3 mm Pole to be screw fitted into fabrication, actthed to with 50mm depth aluminium frame
for media signage mounting , with media accomodation depth of 6mm , frame screw fitted at
121 multiple position along vertical and horizontal side facing the octagonal pole. (size as per drawing) NOS 2.00 28,750.00
with in built slots to accomodate media (ACP,ACRYLIC,PLY etc) cover list profile used to specify left
out below portion for display installed with fixbox alumnium component provided with system for
Text panel fixing with pole sign to be installedat site in plumb and level at specified location as per
drawing to the satisfaction of the engineer-in-charge. Graphics to be done using printed retro
reflective material.
Size - 460mm * 600mm (Frame) * 2400mm Pole Height
Mounting Type - Ground/RCC
Signage - Lite/Nonlite (As per approved drawing)
Parking Suspended Signs
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is double sided 50 mm
depth profile with media accomodation depth of 6 mm media of ACP acrylic upto 3 mm thickness
can be pasted directly on frames or attched on frame with help of dual lock tape.Sign can be
122 edge lite with help of edge lite led modules ,led of LUCOLED make EL31 ,Sign to be fitted and NOS 5.00 21,965.00
installed at site in plumb and level at specified location as per drawing to the satisfaction of the
engineer-in-charge. Graphics to be done using printed retro reflective material.
Size - 1200mm * 300mm * 50mm
Mounting Type - Ceiling Suspended
Signage - Lite/Nonlite (As per approved drawing)
Door Nameplate Sign
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection
moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed
123 on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at NOS 20.00 776.25
specified location as per drawing to the satisfaction of the engineer-in-charge. Graphics to be
done using printed retro reflective material.
Size - 300mm * 156mm * 12mm
Mounting Type - Door/Wall
Signage - Nonlite
Building Directory Sign
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium side tracks and common click clips for panel fitting. a.Sign is including all plastic
124 injection moulded clips black in shade which are slided in side tracks ,media can be flat bed UV Sqft 9.00 2,070.00
printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at
specified location as per drawing to the satisfaction of the engineer-in-charge.
Size - As per Drawing
Mounting Type - Wall
Signage - Nonlite
Floor Directory Sign
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium side tracks and common click clips for panel fitting. a.Sign is including all plastic
125 injection moulded clips black in shade which are slided in side tracks ,media can be flat bed UV Sqft 30.00 2,070.00
printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at
specified location as per drawing to the satisfaction of the engineer-in-charge.
Size - As per Drawing
Mounting Type - Wall
Signage - Nonlite
Staricase ID Sign
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection
126 moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed NOS 18.00 776.25
on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at
specified location as per drawing to the satisfaction of the engineer-in-charge.
Size - 300mm * 156mm * 12mm
Mounting Type - Door/Wall
Signage - Nonlite
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection
moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed
127 on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at NOS 72.00 592.25
specified location as per drawing to the satisfaction of the engineer-in-charge. Graphics to be
done using printed retro reflective material.
Size - 200mm * 156mm * 12mm
Mounting Type - Wall/Door
Signage - Nonlite
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection
128 moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed NOS 180.00 476.10
on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at
specified location as per drawing to the satisfaction of the engineer-in-charge.
Size - 156mm * 156mm * 12mm
Mounting Type - Wall/Door
Signage - Nonlite
Lift Number Sign
Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium
homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International
standards, with 10 years warranty under normal working conditions.Sign is single sided with
aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection
moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed
129 on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at NOS 60.00 592.25
specified location as per drawing to the satisfaction of the engineer-in-charge. Graphics to be
done using printed retro reflective material.
Size - 200mm * 156mm * 12mm
Mounting Type - Wall/Door
Signage - Nonlite
Lift in case of fire use stair
Providing sign of Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008
tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with premium
grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty
under normal working conditions. Profile to form frame with overall depth of 10 mm with media of
thickness upto 3mm. 2 mm thick acrylic/ACP . I-sign Fix profile of Cosign make with M.S zinc coated
corners with grub screws. Installed at site in plumb and level at specified location as per drawing to
the satisfaction of the engineer-in-charge. Graphics to be done using printed auto glow material.
Size - 250mm * 150mm * 10mm
Mounting Type - Wall
Signage - Photoluminescent
Fire extinguisher Sign
Providing sign of Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008
tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with premium
grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty
under normal working conditions. Profile to form frame with overall depth of 10 mm with media of
thickness upto 3mm. 2 mm thick acrylic/ACP . I-sign Fix profile of Cosign make with M.S zinc coated
131 corners with grub screws. Installed at site in plumb and level at specified location as per drawing to NOS 100.00 917.70
the satisfaction of the engineer-in-charge. Graphics to be done using printed auto glow material.
Size - 300mm * 150mm * 10mm
Mounting Type - Wall
Signage - Photoluminescent
Emergency Exit Sign
Providing ready sign & fixing at location a Cosign make emergency exit sign- illuminated, surface
mount (wall or ceiling) Dual sided made up of plastic material , battery backup of 3 hours (180
mins) .Battery life of 300 cycles of charge & discharge Li- ion battery 3.7 Volt, 100 mA, Charge time
of 24 hours. Input voltage 220-240 Volt A.C, 50/60 Hz. Viewing distance 30 meter, degree of
protection IP20 (rating for protection against solid object upto 12 mm) white light colour full back
(white colour) LED illumination with green white coloured graphic inserted on both sides on 0.4 mm
PC (sizes, texts, symbols or graphics as per standard safety norms & regulations) graphic options of -
left ,right, up staircase down staircase. Test facilty button self test plus auto self test, opreration in
132 maintained and non maintained mode (power saver mode).Sign with 12 months warranty for NOS 15.00 3,783.50
electric circuit & 6 months warranty for battery. Sign provided with dual mounting arrangement of
mounting on wall & celing both ( with flat rigid support/base).Sign is including all connection wires
(upto 1 mtr) & high tensile strength zinc coated self tapering screws (4 nos with screw wall plastic
packing), installed at site in plumb and level at specified location as per drawing to the satisfaction
of the engineer-in-charge.
Size - 310mm * 225mm * 55mm
Mounting Type - Ceiling
Providing & fixing in position heavy quality FRP bucket (UV resistant) of below mentioned size, at all
floors, levels & location having approved colour & shade, including labour, material, fixing
arrangements, screw, washer, scaffolding etc complete all as per specifications, drawings & as
directed by the Engineer-in-Charge.
133.1 1200mm L x 400mm B x 600 mm H, wall thickness minimum 4 mm. NOS 435.00 8,237.29
Aluminium Louvers (Box Type Louvers) System: Providing, supply, fabrication, installing, fixing, testing,
cleaning, protection and handing over the Aluminium box type louvers system, at all levels,
locations, floors as per approved drawings including all labour, material, wastage, transporation,
fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by
the Engineer-in-Charge.
134 The Aluminium box type louver system shall with stand the wind pressure of confirming to IS -875 part
III. The Aluminium box type louver system shall have louvers of size 100 mm X 50 mm X 2 mm
thickness vertical box louvers at 100 mm c/c. Including providing & fixing Aluminium frame to
support aluminium louvers, Louver profile shall be fixed at an angle (as per drawing) to form a
frame, necessary MS brackets with SS-316 fastners, EPDM gasket, non staining weather sealant, SS-
304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for
aluminium box type louver system as per drawing of approved manufactures with extruded
sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as
shown in the drawing [including wastages if any] conforming to relevant I.S specifications,
including grouting the gap with thermocole & polysulphide sealant, providing & fixing MS brackets
etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in
charge. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 &
tolerances confirming to DIN / EN standards from approved make and manufacturer. The
aluminium sections shall have approved shade and colour super durable powder coating with
minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing
treatment. {The weight of extruded aluminium sections only will be mesured for payment}).
Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the
Aluminium (Z-Type) louvers system, at all floors, levels & locations, aluminium section [extruded] for
aluminium Z type louver system as per drawing of approved manufactures with extruded sections
of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in
the drawing [including wastages if any] conforming to relevant I.S specifications, including grouting
the gap with thermocole & polysulphide sealant, providing & fixing MS brackets etc. all complete
generally as per drawings, specifications etc., all as directed by Engineer in charge. (The aluminium
system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN
/ EN standards from approved make and manufacturer. The aluminium sections shall have
approved shade and colour super durable powder coating with minimum 50 micron thickness. The
135 non visible aluminium sections shall have approved chromatizing treatment. {The weight of KG 7,619.69 450.00
extruded aluminium sections only will be mesured for payment}).
The Aluminium Z type louver system shall with stand the wind pressure of confirming to IS -875 part III.
The Aluminium Z type louver system shall have louvers of size as per drawing and thickness of Z
shape louvers, fixed at fixed distance (as per drwing) to alumnium frame, louver profile to be fixed
on 3 mm thick aluminium flat to form a frame, the louver frame is supported on the aluminium box
frame including providing & fixing SS-316 fastners, necessary MS brackets with SS-316 fastners, EPDM
gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
FOOD Kiosk Container – Providing, fabricating, supplying and installing in True line & level on
specified level as per detailed drawings for Pre-fab Factory Made Portable Container type Food
Kiosk Counter in Hot dip Galvanised Structural members and GI Sheet having size of 20' x 8' x 8' with
following facilities inside of each compartment as per specifications:
(1) Work table (Type 1) in one number of size 3910 x 600 x 925 mm or as per drawing and provision
for 2 nos. under counter refrigerator to be made as per specification
(2) Work table (Type 2) in one number of size 2340 x 600 x 925 mm or as per drawing and to be
provided with 250mm height shelf under the counter top with SS supports & partitions.
(3) 2 no's SS Sink unit & bottom pipe shelf as per drawing & 1 no SS pipe shelf mounted above sink
unit on wall with SS 316; size: 1370x300 mm at 600mm from top of sink.The unit shall be fabricated
with 3 openable shutter as shown in drawing.
(4) All the preparation tables & sink tables should have 16 GA fabrication sheet at the top and the
grade of steel used should be SS 316(Jindal Make).
136 (5) Side wall ventilation (type-1) in one number of size 755 x 158 mm to be provided horizontally as NOS 12.00 17,50,000.00
per drawing. Unit to consist of 03 such vents separated by the structural frame of the container as
indicated in drawings.
(6) Side wall ventilation (type-2) in two numbers of size 755 x 158 mm with exhaust fan (outer size
158x158mm)of preferred make and model as per drawing.
(7) Back wall ventilation (type -1) in three number of size 1175 x 158 mm to be provided horizontally
as per drawing. Vents shall be provided from the center of the wall and separated by the structural
frame of the container.
(8) Back wall ventilation (type-2) in two numbers of size 1150 x 158 mm with exhaust fan (outer size
158 X 158 mm)of preferred make and model as per drawing. All vents to be provided from the
centre of the wall separated by structural frame of the drawing. Each ventilation opening to have
50 mm wide MS plate frame projecting from the outer surface of the container on all 4 sides.
(9) Two service windows with flap door of size 1360 x 1025 mm at the front longer side on container.
Window sill to be at 925 mm height from the container floor finish level.Each window to be fitted
with 900mm height flap shutter foldable to 500mm, where the 500 mm portion serves as a counter
top when open and the remaining 400 mm folds back anchored to the container. Features include
a 125 mm height perforated panel at the top, 03 hooks on the outside for counter anchoring, and
04 nos. hook and stopper for internal closing.
(10)Main Door of size as per specification and drawing. Outside handle to be vertical D Type
(minimum 450mm high and 25mm diameter) with the top fixed at 1200mm from the door bottom.
Entry shall include 01 No. aldrop installed on the adjoining part and a door closer provided at a
level of 900mm from the door bottom. Inside shall be provided with a mortise handle set with lever
mortise lock (horizontal lock). Door must be fixed at a proper level to avoid obstruction while
(11) Flooring to be covered with PVC vinyl sheet with proper drainage for water.
(12) Inner wall & ceiling shall be finished with Cement board including painting.
(13) 1 no Waste Bin Trolley below Sink with size of 375mm dia & 650mm Height with wheels.
(14) Three fans of 1200mm dia
(15) Electrification: It is provided with 6 Nos. of LED light (15Watt) & 6 No. 25Amp. Switch & socket &
on/off switch for commercial kitchen equipment, Points.
(16) To be provided with 1 no of water tank (Sintex/equivalent Make) made of Plastic having
capacity of 500 ltr. All welding joint should be TIG welded. The supplier should have manufacturing
set up should be certified with EN-15085 and ISO 9001:2015 from a recognized third party agency.
17) Supply and Fixing of mechinical foam type Fire Extingusher conforming to IS 15683:2018 as per
the required capacity of 6 liters to 9 liters.
Notes: 1) Contractor shall provide 10 years guarantee for container materials & facility inside
material & accessories including 1 year defect liabilities period & 4-years M&R scope.
2) Refer Container specifications attached in Specification Volume.
3) Contractor shall connect all water supply and drainage services to the given point in external
water and drainage network system as directed by EIC.
4) All the ironmongery shall be as approved by architect.
5) All structural members must be hot dip galvanised.
6) All Furniture shall have edge banding
7) All structural members shall be painted with 300-500 micron of Epoxy paint system with PU top
coat of 50-60 micron as per manufacturer specification with 10 years guarantee.
8) Container shall be fire proof & shock proof.
Providing and fixing in position, at all levels & loaction, stainless steel (SS-304) Mosquito Net/ Wire
Mesh/ Wire gauze made with 0.5 mm dia wire and 1.4 mm aperture (on both directions) including
fixing, cutting, wastage, scaffolding etc. complete all as per specifications and as directed by the
Engineer-in-Charge. Note:- 1) For aluminium work with aluminium beading channel. (Aluminium
beading channel will paid under relevant item).
Supplying, providing, placing, installing and fixing in position in true line and level as per detail
drawing approved by EIC, MODULAR TOILET PARTITIONS along with specified brand or approved
equivalent of size as per detail drawings, Floor mounted including providing and fixing all
accessories, fixtures, fastenings, hinges, anchorages, all hardware with approved locking
arrangement as recommended by manufacturer and as approved by EIC etc. complete as
directed, at all levels. Item description:
Cubicle size - 900mm x 1550mm x 2100 mm (height is including 150 mm gap from bottom).
Colour of Boards : As per the Shade card - approved by EIC. Thickness of Compact Sheet : 12mm
(min.). Material:Compact Laminate in panels. Made from solid grade compact high-pressure
laminate as per IS:2046 and EN438- manufactured under high specific pressure > 5 MPa and
temperature 120° C with bunch of kraft papers impregnated with thermosetting phenolic resin and
138 decorative papers made of cellulose fibre impregnated with thermosetting melamine resin which NOS 112.00 34,200.00
provide superior scratch, abrasion, heat, chemical, impact, graffiti & moisture resistance along with
anti-bacterial properties. Panels have a black core that when machined, presents a distinctive
black edge. Size of panels to be as per drawing.
Door size - 1750 x 600(H X W)
All doors will be of single colour and made of 12 mm thick HPL compact panel. The doors will have
chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the
pilasters. Stainless steel made coat hook and Lock set (comprised of Thumb turn and occupancy
indicator) are provided with each door. All the doors will be routed at the vertical ends and the
rubber sponge lining will be incorporated at the routed ends.
Pilaster dimension - 1830 x 300 (H X W).
All pilasters will be made of 12 mm thick HPL compact panel with chamfered edge and completed
with stainless steel made thumb turn lock set. Pilasters will be anchored to the floor using stainless
steel made adjustable legs. All pilasters will be routed at their vertical ends to facilitate closure of
doors. The bottom gap is 150-100 mm.
Dividers - 1775 x 1550 (H X W)
All intermediate partitions or dividers will be made of 12 mm thick HPL compact laminate panels.
They are affixed with stainless steel made U-channel at their ends for ultimate stability of the system.
Hardware and Accessories Details : below mentioned all accessories – Stainless Steel - 304 Grade
a) Adjustable Pedestal Footing of base diameter 60 mm made from Stainless steel grade 316 giving
an adjustable height of 100mm to 150mm. Surface finish to be matt type.
b) SS U -Channel
c) SS F Channel
d) SS Door Stopper Channel
e) SS Top Rail with circular cross section (Diameter 32mm). Surface finish will be mirror type.
f) SS Coat Hook with rubber stopper made from Stainless steel grade 304. Surface finish to be
g) SS Privacy Thumb turn c/w Occupancy Indicator made from Stainless steel grade 304. Surface
finish to be lacquer type.
h) Round Door knob diameter 30 mm with grooves for better hand grip made from Stainless steel
grade 304. Surface finish to be matt type.
I) SS Spring Loaded Butt Hinges with Cover
j) Anti-noise rubber padding of thickness 2 mm and width 10 mm
k) Screws & Wall Plugs. Stainless steel grade 304 screws.
l) Tubular panel holder made of stainless steel grade 304. Surface finish will be lacquer type.
m) Corner joinery section made from Stainless steel grade 304. Surface finish to be brush type. A thin
plastic film pasted for surface protection. Size to be 35mm x16.4mm x 0.8 mm.
n) Wall joinery section with hamming profile made from Stainless steel grade 304. Surface finish to
be brush type. A thin plastic film is pasted for surface protection. Size to be 21mm x 16mm x 0.8 mm.
Supplying, providing, placing, installing and fixing in position in true line and level as per detail
drawing and approved EIC, Modular Toilet Urinal partition UMP along with specified brand or
approved equivalent of size as per detail drawings, Colour of Boards : As per the Shade card -
approved by EIC.
Item description:
139 The Urinary Panel has a 12 mm thick High Pressure Laminates (HPL) Compact Board, with a NOS 58.00 5,750.00
recommended panel width dimensions of 400-500 mm. The size of the panel is 500 mm (W-Top) X
400 mm (W-Bottom) X 1200 mm (H), with the overall height of 1200 mm. Final Size of Partitions : As
per drawing given - shop drawings approved by EIC.
Accessories Details : below mentioned all accessories –
Stainless Steel - 304 Grade made 2 brackets used to fix each urinal panels to the walls.
Supplying and fixing in position various dia GI pipe for sleeves, using 'B' class (medium duty) GI
pipes of any diameter as per requirement and as per drawing for sleeves etc. including cutting,
placing in position, bending, welding, in line and level, at all levels & location including painting
with one coat of approved zinc chromate primer, scaffolding. labour, wastage etc. complete all as
per specifications, drawings and as directed by the Engineer in charge
Providing and fixing PVC rungs of Thickness 25mm, Length 170mm, Usage/Application Rungs, Stairs,
Standards IS Features. Anchor type fixing at all levels as directed by EIC.
Providing, supplying, and fixing modular welded mesh fencing system of approved make
comprising of galvanized MS wire mesh panels, pre-galvanized H-profile posts, anchors, and all
necessary accessories, complete in all respects.
Panel Material: Galvanised MS wire with min. 40 GSM coating and tensile strength > 65 kg/mm²,
Panel Coating: Pure Polyester Powder Coating (PPC), thickness > 65 microns, tested for 1000 hrs in
salt spray (ASTM B117), Mesh Aperture Tolerance: ± 2 mm, Welding Specification: Electrical
Resistance Welding, Weld strength of 4 random welds ≥ 50% of vertical wire tensile strength, Panel
Width: 2500 mm, Post C-C Distance: 2515 mm, Post Type: Pre-galvanized MS, H-profile with 80 GSM
zinc coating, Post Cap and Anchor Cap: PVC, Anchors: GI anchor bolts M12 × 150 mm, Fixings per
142 Post: 6 fixings for Mini, Regular, Panel Size Options (as per site requirements): Mini: 1260 mm height, RMT 115.50 3,800.00
Post Lengths: 1300 mm
Installation Details: Posts fixed using M12 × 150 mm anchor bolts over concrete/paved surfaces.
Panels secured using anti-vandal tamper-proof fixings and brackets. Complete system installed
plumb, aligned, and in straight lines as per site drawing/layout. Rate to include supply,
transportation, all hardware (posts, panels, fasteners, caps, anchors), labour, equipment, layout
marking, drilling, surface preparation, fixing, finishing, and disposal of debris, etc., complete as per
manufacturer’s specification and direction of Engineer-in-Charge.
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked
together through their entire length and jointed together at the ends by end locks mounted on
143 specially designed pipe shaft with bracket plates, guide channels and arragements for inside and Sqm 8.82 3,468.72
outside locking with push-pull operation including the cost of hood cover and spring etc.
complete.(A)Shutters having width below 3.5 M.
WALL MOUNTED LED - Outoor
The scope of work includes the design, supply, installation, testing, and commissioning of a wall-
mounted digital screen. The exposed surface of the niche excluding the LED display area to be
finished in ACP powder coated sheet with necessary ply backing.The work also involves necessary
staging, testing of all functionalities, and commissioning to ensure full compliance requirements of
Project-In-Charge (PIC).
3mm thick ACP sheet powder coated in black (RAL 9005) with 8mm thick commercial plywood
backing WALL MOUNT DIGITAL SCREEN of mentioned size
144 The video system shall consist of active indoor Direct LED based seamless large screen video wall
system with front service access LED technology to reproduce excellent colors(up to 110% NTSC).
Contrast ratio Minimum 4000 :1, color processing depth of 24 bit, viewing angle 160º±5 degrees
(Horizontal & Vertical) . It will be necessary that the videowall along with controller can reproduce
excellent color reproduction with HDR10 and HLG. The LED cabinet/modules to be enclosed with
10mm MS profile powder coated in RAL 9005 (black), LED pixel P3
Adequate number of power/data cables and necessary controllers need to be considered by the
vendor for internal looping. Installation of this screen will be on the wall, the fabrication of mounts/
installation etc. shall be in vendor’s scope.
144.1 WALL MOUNT DIGITAL SCREEN 2M x 2.4M Sqft 57.75 10,500.00
144.2 WALL MOUNT DIGITAL SCREEN 2M x 9M Sqft 203.36 10,500.00
WALL MOUNTED LED - Indoor
The scope of work includes the design, supply, installation, testing, and commissioning of a wall-
mounted digital screen. The exposed surface of the niche excluding the LED display area to be
finished in ACP powder coated sheet with necessary ply backing.The work also involves necessary
staging, testing of all functionalities, and commissioning to ensure full compliance requirements of
Project-In-Charge (PIC).
3mm thick ACP sheet powder coated in black (RAL 9005) with 8mm thick commercial plywood
backing WALL MOUNT DIGITAL SCREEN of mentioned size
145 The video system shall consist of active indoor Direct LED based seamless large screen video wall
system with front service access LED technology to reproduce excellent colors(up to 110% NTSC).
Contrast ratio Minimum 4000 :1, color processing depth of 24 bit, viewing angle 160º±5 degrees
(Horizontal & Vertical) . It will be necessary that the videowall along with controller can reproduce
excellent color reproduction with HDR10 and HLG. The LED cabinet/modules to be enclosed with
10mm MS profile powder coated in RAL 9005 (black), LED pixel P3
Adequate number of power/data cables and necessary controllers need to be considered by the
vendor for internal looping. Installation of this screen will be on the wall, the fabrication of mounts/
installation etc. shall be in vendor’s scope.
145.1 WALL MOUNT DIGITAL SCREEN 1.2M x 1.5M Sqft 20.34 10,500.00
Sanitary Napkin vending machine
Supply and installation of a fully automatic electronic sanitary napkin vending machine fabricated
from a durable stainless steel chassis with a powder-coated finish suitable for wall-mounted
applications. The unit shall feature a storage capacity of 50 napkins and utilize a heavy-duty coin-
operated mechanism designed to accept multiple denominations for immediate dispensing. The
146 machine, with approximate dimensions of 50cm x 15cm x 30cm and a unit weight of 7kg, shall NOS 18.00 10,000.00
include an integrated electronic display for user instructions, a secure locking system for coin and
stock protection, and a reinforced collection tray. The scope of work involves providing all
necessary mounting hardware, wall fixings, and electrical connections to ensure a fully functional
and secure installation.
Drinking water fountain
Supply and installation of a wall-mounted drinking fountain manufactured from heavy-duty,
corrosion and stain-resistant stainless steel suitable for indoor and outdoor environments. The unit
shall feature a 280 mm (11.02”) diameter basin with rounded safety edges, a 2.3 kg (5.1 lb.) chassis
147 weight, and a push-button valve for single-finger operation. The installation includes the secure NOS 54.00 46,000.00
mounting of the 224 mm H x 323 mm W x 356 mm D (8.8” H x 12.7” W x 14” D) unit to the wall
structure to ensure a total weight capacity of 45 kg (100 lbs). Work is to be complete with the
provision and connection of all necessary plumbing attachments, internal fittings, and hardware
required for a fully operational water dispensing system.
60L open top dustbin stainless steel silver 14x24 inch
Supply and placement of a heavy-duty, cylindrical open-top dustbin fabricated from 0.5 mm thick
SS202 grade stainless steel with a polished silver finish. The unit shall have a storage capacity of
liters and measure approximately 355.6 mm in diameter by 609.6 mm in height (14x24 inch). The
design shall feature a reinforced swing-open top for hygienic waste disposal and a durable body
suitable for high-traffic indoor and outdoor environments. The scope of work includes the delivery of
the finished product to the site, ensuring all units are provided with compatible internal liners and
ready for immediate operational use.
35L open top dustbin stainless steel silver 10x28 inch
Supply and placement of a heavy-duty, cylindrical open-top dustbin fabricated from 0.5 mm thick
SS202 grade stainless steel with a polished silver finish. The unit shall have a storage capacity of
liters and measure approximately 254 mm in diameter by 711.2 mm in height (10x28 inch). The
design shall feature a reinforced swing-open top for hygienic waste disposal and a durable body
suitable for high-traffic indoor and outdoor environments. The scope of work includes the delivery
of the finished product to the site, ensuring all units are provided with compatible internal liners and
are ready for immediate operational use.
External Illuminated Metal Letter Signage
Providing, fabricating, and fixing individual 3D letters for the signage “Riverside Savories” in SS-316
grade stainless steel (minimum 1.6 mm thick), in English/Gujarati as per approved architectural
design and drawings.
The letters shall be of size, depth, and profile as per detailed design and as approved by the
Engineer-in-Charge (EIC). Each letter shall be fabricated with necessary internal stiffeners and rigid
SS back ties to maintain true shape and alignment. The work includes providing and fixing all
required components such as SS plates, brackets, nuts, bolts, washers, studs, welding, and chemical
anchor fasteners of same or compatible material for firm and durable fixing to wall/tower structure,
ensuring stability, durability, and performance for a minimum period of 10 years.
The signage shall be provided with concealed waterproof LED backlighting/halo lighting system,
including routing and fixing of LED modules as per letter profile and curves to achieve uniform
illumination. LED colour and illumination effect shall be as approved by the Architect/EIC, ensuring
clear legibility and visibility from a long distance. The item includes supply and installation of all
150 necessary drivers, boosters, transformers, wiring, conduits, connectors, and allied accessories, NOS 1.00 5,50,000.00
properly concealed within letters or structure.
Where required as per design, provision of suitable external lighting fixtures such as spot lights, LED
fixtures, bollards, etc., shall be included to achieve the desired lighting effect.
The contractor shall submit the proposed font style, artwork (PDF format), and detailed shop
drawings including fixing methodology, LED layout, driver arrangement, and mounting details for
prior approval. A mock-up of minimum three letters with approved lighting effect shall be prepared
for review and approval before full-scale execution.
The rate shall include all materials, labour, fabrication, transportation, scaffolding, lifting
arrangements, safety measures as per applicable guidelines, testing, commissioning, and complete
installation at all heights. No extra payment shall be made for any component required to
complete the work in all respects.
Providing and laying weep hole in abutments, and returns by using PVC pipe of 100mm diameter
151 including laying in proper grade and jointing the completed as per detailed specification. NOS 50.00 552.77
Providing and installing scluptures from the below list as per architecture/vendor/artist design
152 inluding all necessary hardware, accessories, etc, as per the satisfaction of design intent provided NOS 6.00 20,00,000.00
by architect/vendor/artist and approval of engineer in charge (EIC)
Supplying, Providing, Fabricating, Assembling, hoisting, erecting and placing in position MS Built-up
section/Tubular Structure ( MS built-up section :-Rolled section & plates confirming to IS 2062 Grade
Yst 350,Tubular Structure:- made from Steel hollow sections, ISI marked from SAIL / RINL /
TATA/JINDAL, conforming to IS 1161/4923/1239, Minimum Yst 240 thickness upto 10mm ) in the profile
shape as per drawings with special plate connector, pinion joints, Plates, hollow sections etc. With
special plate connectors, pinion joints, plates, hollow sections including Preparation of detailed
fabrication and erection drawings of Structural steel work from design drawings issued by Engineer-
In-Charge and incorporation of Engineer-In-Charge's comments on same, ransportation from
fabrication yard, cutting , threading, machining, leads and lifts upto all heights, tools and plants
153 and necessary scaffolding etc. required for all operations involved to make structure of Tensile KG 19,000.00 220.00
Membrane shade. The tubular structure system with plate connectors, pinion joints, etc. is to be
provided. The structure has to be provided as per conceptual drawings of Tensile fabric profile
including all arch beam, curved lateral beams and bracings, vertical support columns, nodal joints,
,bases of columns and high tensile bolts of grade not less than 10.9 having black phosphate
coating. The complete structure to be Hot Dip Galvinized along with one coat of epoxy primer and
two coats of Polyurethane paint on steel work at all locations prepared by sand blasting in required
minimum 210 micron DFT (dry film thickness) for each coat as specified in particular specification.
The work is to be executed as per technical specification and direction of Engineer-In-Charge.
Supply and Installation of membrane shall be PVC, Both side PVDF coating with HT Polyester Yarns
of 1100 Dtex . Fabric Type 2 with minimum weight of 950 g/m2, minimum Tensile Strength (Warp/
Weft) - 4200/ 4000 N/5cm, minimum Tear Strength (Warp/ Weft) - 550/500 N. Fabric Flame
Retadancy Rating to be Euro Class - Bs2, d0, Micro Organism Resistance and minimum Warranty of
15 years. The design complies with the requirements of BS and, EU Standards. The tensioned
membrane structure shall include engineering design of structural members and accessory parts.
Membrane system shall include PVC/ PVDF coated Membrane Fabric, Wire Ropes and Cables,
Shackles, Rigging Screws, Clamps and tensioning hardware as per specification, drawings and
engineers approval. Cost including Scafolding and cranes.Make- Serge Ferrari/Verseidag/Mehler
Design, Supply, Fabrication and Installation of Membrane Panels. Membrane shall be Fiberglass
fabric EC 6 filaments and Both sides multi-layer Polytetrafluoroethylene reinforced coating having
minimum Weight of 670 g/m2. The Fabric shall have minimum 21% openness porosity for Maximum
Light Visibility with minimum Tensile Strength (Warp/ Weft) - 6000/ 6000 N/5cm, minimum Tear
Strength (Warp/ Weft) -500/500 N/5 cm. Fabric Flame Retardancy Rating to be Non combustible
class A2/DIN 4102 — A2-s1,d0/EN 13501 — ASTM E136 — ASTM E84 — NFPA 701 —Cal T19. Warranty of
10 years and Life span of 35 plus years with proven track record. The applicator to submit the fabric
load analysis for approval of fabric. Cost shall include the supply of fabric/SS Cables with end
terminals minimum 25mm thickness for main grid and minimum 10mm thickness for edge cable
alongwith all the accessories. Fabric Flame Retardancy Rating to be Euro Class - Bs2, d0, Micro
155 Organism Resistance-Degree 0 Excellent – EN ISO 846-A and Warranty of 10 years and Life span of SQFT 38,750.00 1,150.00
30 plus years with proven track record. The design complies with the requirements of BS and, EU
Standards. The tension membrane structure shall include engineering design of structural members
and accessory parts. Membrane systems shall include PVC/ PVDF coated Membrane Fabric,
Clamps and tensioning hardware as per specification, drawings and engineers’ approval. Vendor
to provide an OEM certificate for authorisation. The Mesh must withstand its Self-load and
windspeed resistance of up to 180-200kmph. All the accessories like GI Cables, Turnbuckels,Brackets
to be fixed to the substructure/Civil work considering the weathering effects
(windspeed/loadbearing capacity/Structural strength).
Fabric analysis report shall be provided by vendor to understand the load calculation. Steel
consumption to be provided by vendor.The entire system has to be backed up by a structural
stability report.MS Built-up section/Tubular Structure ( MS built-up section :-Rolled section & plates
confirming to IS 2062 Grade Yst 350,Tubular Structure:- made from Steel hollow sections, ISI marked
from SAIL / RINL / TATA/JINDAL, conforming to IS 1161/4923/1239, Minimum Yst 240 thickness
upto10mm ) in the profile shape as per drawings with special plate connector, pinion joints, Plates,
hollow sections etc. with special plate connectors, pinion joints, plates, hollow sections including
Preparation of detailed fabrication and erection drawings of Structural steel work from design
drawings issued by Engineer-In-Charge and incorporation of Engineer-In-Charge's comments on
same, ransportation from fabrication yard, cutting , threading, machining, leads and lifts upto all
heights, tools and plants and necessary scaffolding etc. required for all operations involved to
make structure of Tensile Membrane shade. The tubular structure system with plate connectors,
pinion joints, etc. is to be provided. The structure has to be provided as per conceptual drawings of
Tensile fabric profile , including all arch beam, curved lateral beams and bracings, vertical support
columns, nodal joints, ,bases of columns and high tensile bolts of grade not less than 10.9 having
black phosphate coating. The complete structure to be Hot Dip Galvinized along with one coat of
epoxy primer and two coats of Polyurethane paint on steel work at all locations prepared by sand
blasting in required minimum 210 micron DFT (dry film thickness) for each coat as specified in
particular specification. Required detailed shop drawing and sample is needs to get approved
from the project Architect before execution on site. Work shall be carried out as directed by the
Engineer-In-Charge. Make List-SergeFerrari/Sherfil /Chucko/F.I.T/Fibertech
ELECTRICAL & ELV CHAMBER
Construction of ELECTRICAL & ELV chamber of size 750x750x1200 mm including excavation,
backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C
work of M-30 for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level.
It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water
proofing and outside of chamber with 20mm thick sand faced cement plaster in two coat at all
156 sides. making core cuts/providing sleeves for cables incoming and outgoing Top shall be covered NOS 18.00 24,000.00
with FRP Recessed MH cover with clear opening of 600x600mm with frame and cover bearing load
min. 25 T and size as Mentioned in Drawing. It shall be completed with all respect in true line level,
plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of
Construction of ELECTRICAL & ELV chamber of size 600x600x1000 mm including excavation,
backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C
work of M-30 for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level.
It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water
proofing and outside of chamber with 20mm thick sand faced cement plaster in two coat at all
157 sides. making core cuts/providing sleeves for cables incoming and outgoing Top shall be covered NOS 1.00 21,000.00
with FRP Recessed MH cover with clear opening of 600x600mm with frame and cover bearing load
min. 25 T and size as Mentioned in Drawing. It shall be completed with all respect in true line level,
plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of
Construction of ELECTRICAL & ELV chamber of size 450x450x900 mm including excavation,
backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C
work of M-30 for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level.
It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water
proofing and outside of chamber with 20mm thick sand faced cement plaster in two coat at all
158 sides. making core cuts/providing sleeves for cables incoming and outgoing Top shall be covered NOS 4.00 17,500.00
with FRP Recessed MH cover with clear opening of 600x600mm with frame and cover bearing load
min. 25 T and size as Mentioned in Drawing. It shall be completed with all respect in true line level,
plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of
LANDSCAPING WORK
Excavation for foundation by mechanical / manual means in all kind of soils & soft rock up to 0.9mtx
0.9 mt x 1.5mt. depth including backfilling, shoring, strutting dewatering as necessary, sorting out
159 and stacking of useful materials and disposing of the surplus excavated material within campus etc cum 540.00 198.00
complete all as per specifications and as directed by EIC.
Supplying and filling of tree pits, shrub bed & lawn beds with Fertile Soil Mix with Farm Yard Manure
on datum level in the following percentage - 15% Farm yard Manure, 20% river sand or locally
available "Dhaap", and 65% Black Cotton Soil by volume graded towards the drains & chambers
160 located at site with a minimum slope of 1%. (Black cotton soil to be taken from the Emcure site) etc. cum 1,500.00 475.00
complete as directed by EIC. Recommended fill of the beds are as follows: 1. Tree/ Palm Pits -
900x900x900mm; 2. Shrub beds/ground cover - To a depth of 300mm; 3. Lawn beds - To a depth of
Providing and planting ( as directed by the consultants / Engineer in charge) well grown saplings of
161 big trees species (as listed below) and planting the same as directed and maintained till well
established. (About 45 Days)
161.1 Bauhinia purpurea NOS 53.00 282.00
161.2 Erythrina variegata NOS 25.00 225.00
161.3 Plumeria obtusa NOS 18.00 1,350.00
161.4 Plumeria rubra NOS 4.00 1,350.00
161.5 Terminalia mantaly NOS 13.00 450.00
161.6 Lagerstroemia speciosa NOS 33.00 282.00
161.7 Cassia fistula NOS 17.00 338.00
161.8 Alstonia scholaris NOS 33.00 282.00
Supplying and planting Saplings (as directed by the Consultants / Engineer in Charge) of shrubs
162.1 Alpinia purpurata Nos 750.00 394.00
162.2 Alpinia zerumbet variegata Nos 2,143.00 394.00
162.3 Angelonia angustifolia dwarf Nos 1,091.00 113.00
162.4 Canna indica Nos 664.00 169.00
162.5 Dieffenbachia wilson's delight Nos 750.00 169.00
162.6 Eranthemum purpureum Nos 750.00 169.00
162.7 Leucophyllum frutescens Nos 750.00 169.00
162.8 Murraya paniculata Nos 1,285.00 79.00
162.9 Mussaenda philippica rosea Nos 3,267.00 169.00
173.10 Pandanus variegated Nos 1,081.00 34.00
173.11 Pseudoeranthemum reticulatum Nos 950.00 113.00
173.12 Schefflera arboricola green Nos 490.00 169.00
173.13 Hymenocallis littoralis Nos 5,657.00 250.00
173.14 Russelia equisetiformis Nos 1,944.00 250.00
173.15 Bougainvillea Nos 2,686.00 20.00
173.16 Tecomaria capensis Nos 4,178.00 100.00
173.17 Liriope muscari Nos 6,798.00 250.00
173.27 Allamanda cathartica 'Compacta' Nos 3,397.00 250.00
163 Supplying and planting (as directed by the Consultants / Engineer in Charge) of Climbers
163.1 Ipomoea palmata Nos 176.00 500.00
163.2 Ipomoea horsfalliae Nos 80.00 500.00
163.3 Bignonia gracillis Nos 109.00 500.00
163.4 Antigonon leptopus Nos 109.00 500.00
163.5 Philodendron Oxycardium Brasil Nos 424.00 800.00
163.6 Philodendron hederaceum Nos 581.00 900.00
163.7 Epipremnum aureum Nos 148.00 500.00
163.8 Syngonium Nos 132.00 800.00
163.9 Trachelospermum jasminoides Nos 148.00 800.00
Supplying and planting Saplings (as directed by the Consultants / Engineer in Charge) of Ground
164.1 Wedelia trilobata Nos 17,140.00 50.00
164.2 Cuphea hyssopifolia Nos 5,280.00 300.00
Supplying and planting Saplings (as directed by the Consultants / Engineer in Charge) of Grasses
165.1 Pennisetum rubra NOS 500.00 400.00
165.2 Pennisetum setaceum NOS 500.00 400.00
TOTAL CIVIL AMOUNT
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
SANITARY FIXTURES AND FITTINGS
SPECIAL NEED FOR DISABLED TOILET
Providing and Fixing EWC wall hung, Wash basin, Grab bar, Hinged rail & special faucet with spachula including seat cover, and flush valve, fittings, nuts, bolts and
gasket etc complete for disabled toilet of approved make and conforming to IS Standards. Wash basin with one pair mounting brackets, Waste coupling 32 mm
size full thread with 80 mm heightJaquar make with 7 years warranty: Chrome plated, Bottle trap Jaquar make with 7 years warranty: Chrome plated etc., EWC S
Trap & Cistern complete with fittings & seat cover, one no. hinged rail 750 mm & Two nos of grab rails 600 mm ,etc. complete as per directed by the Engineer's
Representative.
EWC : KOHLER : S1013200
SOFT CLOSE SEAT COVER : CERA :B1520118
WASH BASIN : CERA : S2040159
SINGLE LEVER CLINICAL FAUCET: CERA :F9030453
600 MM LONG WALL MOUNTED GRAB BAR : CERA :B2210106
WALL MOUNTED HINGED HAND RAIL 750 X 100 : CERA : B2210108
Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend
as per specifications; glazed vitreous / Coloured European Water Closet with Metropole flush valve, connecting PVC 110mm dia soil pipe with PVC coupling, nuts,
mounting cistern on WC., Ragbolt, Gasket Fitiiing and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; hole in walls/slab/beam and
making good etc. complete as per directed by the Engineer's Representative.
EWC-P with PP Soft close Seat cover, Cistern with cistern fittings:
W.C Wall Hung : Jaquar : SLS-WHT-6953BIPPSM/CERA : S1043144/KOHLER : K-20217IN-S-0
Concealed Cistern : HINDWARE : Hindware Cat No 525063/CERA : Cera Cat No B1110111
Providing and fixing in position 15 mm C.P. brass 2 way bib cock of best quality including cutting and making good the wall where required etc. complete as per
directed by the Engineer's Representative.
1.03 2 WAY BIB COCK Nos. 128.00 3270.00
CERA : F1007151
KOHLER : K-16093IN-4-CP
Providing and fixing 15mm C.P. brass angle valve with wall flange complete, including cutting and making good the wall where required etc. complete as per
directed by the Engineer's Representative.
1.04 Angle Valve Nos. 146.00 1305.00
Jaquar, Model No. :OPP-15053PM
CERA : F1019251
KOHLER : K-80154IN-4-CP
Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1Rmt Long pvc Tube and Wall Hook accessories to .complete the item etc. complete as per
directed by the Engineer's Representative.
1.05 Health Faucet Nos. 128.00 1450.00
Jaquar:ALD-CHR-563 GA
CERA : F8030106AB
KOHLER : K-98100IN-CP
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Providing and fixing White glazed vitreous Oval Wash Basin Under-Counter, size 560x430x195 mm., with supporting M.S. or C.I. Brackets, necessary pipe connection
up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full
thread with 80 mm height Chrome plated, Bottle trap Chrome plated , Pressmatic Pillar Cock including necessary fittings with wall Flange etc. complete in all
respects including cutting and making good the walls etc. complete as per directed by the Engineer's Representative.
Wash basin : Jaquar : FLS-WHT-570/CERA : OVAL- S2030102/KOHLER : K-2211IN-0
Waste coupling : Jaquar : ALD-CHR-705/CERA : F8050101/KOHLER : K-45432IN-BV
Bottle trap : Jaquar : ALD-CHR-769L300X190/CERA : CM 104B/KOHLER : K-75823IN-BN
Providing and fixing of C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall
where required etc. complete as per directed by the Engineer's Representative.
1.07 Braided Hose Copper Pipe Nos. 110.00 460.00
Jaquar : ALD-CHR-805B
CERA : F8070402
Providing and fixing Pillar Cock of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc.
complete as per directed by the Engineer's Representative.
CERA : F9020101
KOHLER : K-20747IN-8-CP
Providing and fixing white vitreous china flat back Urinal of size 385x325x635mm as per IS-2556 (Part-2) with C.I. hangers and pipe to wall with C.P. flange with
Sensotronic Sensor Type Urinal flush valve with installation box with control valve Battery / Electric operated automatic flushes of approved make. System provided
with a solenoid valve and valve connected to a 6 volts lithium battery. Unit automatically serves (the range in about 40 cms) and flushes in two steps. The pre flush
is for 2 seconds duration and the final flushing is for 7 seconds duration. The outlet from the flusher shall be connected to urinal with required braided pipes from
sensor to urinal flush connection in fixture.
1.09 complete including cutting and making good the walls wherever required etc. complete as per directed by the Engineer's Representative. Nos. 72.00 8500.00
Urinal :Jaquar : URS-WHT-13253N/CERA : S4020107/KOHLER : K-26474IN-ER-0
Urinal Sensor ,Jaquar, SNR-51097 /KOHLER : K-24199IN-C03-CP
Providing and fixing in position best Indian make toilet recessed type paper holder complete in all respects including cutting and making good the walls etc.
complete as per directed by the Engineer's Representative.
1.10 Toilet Paper Holder Nos. 128.00 2800.00
Jaquar, Model no. ACN-CHR-1551
Providing and fixing electrical hand dryer, fully automatic type etc. complete as per directed by the Engineer's Representative.
1.11 Hand Dryer Nos. 73.00 15300.00
Orchid: OR/HD/9KV P
Dolphy : DAHD0081
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Providing and fixing of Automatic Fragrance Dispenser fixed to wooden cleats with C.P. brass screws etc. complete as per directed by the Engineer's
Representative.
Fragrance Dispenser: EURONICS, Model No.: EA44
Providing and fixing C.P. brass liquid soap container of best quality etc. complete as per directed by the Engineer's Representative.
1.13 Liquid Soap Container Nos. 73.00 11500.00
Jaquar : K-5487K-CP
KOHLER : SDR-WHT-DJ0010F
Providing and fixing Urinal partition with frosted glass approx. size 900 MM (H) X 450 MM (W) having 10 MM of glass thickness, including fixing to wall with suitable
brackets all as per manufacturers specification etc. complete as per directed by the Engineer's Representative.
Urinal Partition: Jaquar, Model No. JSE-CHR-110US450X
INTERNAL DRAINAGE AND RAIN WATER WORKS
(SOIL, WASTE, VENT AND RAIN
Providing WATER
laying PIPING &
and jointing in FITTINGS)
true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
2.01 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 265.00 146.65
joints and fixing the same with adhesive solvent, including cost of all materials
Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
2.02 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 99.00 193.73
joints and fixing the same with adhesive solvent, including cost of all materials
Providing and fixing unplasticized polyvinyl chloride (UPVC) pipes with all the engineered support as per detail technical specification, having thermal stability for
water supply including all UPVC plain and brass threated fitting. This includes jointing of pipes and fittings with one step UPVC solvent cement and testing of joints
complete as per direction of engineer in charge. Scope shall also including cutting, chasing the wall/beam by grinder cutter and making good the same.
Pipe Dia upto 50MM: UPVC (SCH 40)
Pipe Diameter above 50MM: UPVC (SCH 80)
2.03 The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical Rmt. 1017.00 1110.00
specification etc. complete the job.
Product to compliance with occupational safety standards.
Providing, laying and jointing in true line and level 110 mm diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with
rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with eachother with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in
2.04 walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost Rmt. 710.00 826.88
of all materials.
Providing and fixing in position cowel went topipes.
Providing & fixing PVC SWR TYPE B P Trap of 110 X 110 mm diameter with Height riser/ necessary 110MM Diameter of distance piece for wash basin/ sink drain
connection with cockroach trap - square flat cut, Satin-matt finish - 150mm x 150mm of approved Make, making necessary slab/ wall/ beam holes and cutting
2.06 walls, etc. complete. Nos. 292.00 1700.00
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Making Khurras 45x45cm with average minimum thickness of 50 mm. cement concrete 1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate of 20mm nominal
size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a QUOTE of neat cement rounding the edge sand
2.07 making and finishing the outlet complete depth as per site requirement. Nos. 36.00 785.00
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter not less than 440grams.
Providing fixing, testing and commissioning in position 110 mm dia Polypropylene pipe ring fit conforming to EN: 1329, including all fittings such as bends, junctions,
inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam and making good the same.(For Basement ceiling)
Providing fixing, testing and commissioning in position 160 mm dia Polypropylene pipe ring fit conforming to EN: 1329, including all fittings such as bends, junctions,
inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam and making good the same.(For Basement ceiling)
Providing fixing, testing and commissioning in position 200 mm dia Polypropylene pipe ring fit conforming to EN: 1329, including all fittings such as bends, junctions,
inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam and making good the same.(For Basement ceiling)
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
INTERNAL/EXTERNAL WATER SUPPLY NETWORK
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
3.01 following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. Rmt. 362.00 202.97
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
3.02 following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. Rmt. 410.00 247.25
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
3.03 following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. Rmt. 322.00 330.36
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
3.04 following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. Rmt. 260.00 437.66
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
3.05 following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. Rmt. 80.00 647.30
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
3.06 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 40.00 71.93
joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 32mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
3.07 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 157.00 117.97
joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
3.08 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 246.00 146.65
joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
3.09 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 373.00 193.73
joints and fixing the same with adhesive solvent, including cost of all materials.
Providing and fixing unplasticized polyvinyl chloride (UPVC) pipes with all the engineered support as per detail technical specification, having thermal stability for
water supply including all UPVC plain and brass threated fitting. This includes jointing of pipes and fittings with one step UPVC solvent cement and testing of joints
complete as per direction of engineer in charge. Scope shall also including cutting, chasing the wall/beam by grinder cutter and making good the same.
Pipe Dia upto 50MM: UPVC (SCH 40)
Pipe Diameter above 50MM: UPVC (SCH 80)
3.09 The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical Rmt. 225.00 920.00
specification etc. complete the job.
Product to compliance with occupational safety standards.
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Providing and fixing unplasticized polyvinyl chloride (UPVC) pipes with all the engineered support as per detail technical specification, having thermal stability for
water supply including all UPVC plain and brass threated fitting. This includes jointing of pipes and fittings with one step UPVC solvent cement and testing of joints
complete as per direction of engineer in charge. Scope shall also including cutting, chasing the wall/beam by grinder cutter and making good the same.
Pipe Dia upto 50MM: UPVC (SCH 40)
Pipe Diameter above 50MM: UPVC (SCH 80)
3.10 The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical Rmt. 15.00 1110.00
specification etc. complete the job.
Product to compliance with occupational safety standards.
Providing and fixing unplasticized polyvinyl chloride (UPVC) pipes with all the engineered support as per detail technical specification, having thermal stability for
water supply including all UPVC plain and brass threated fitting. This includes jointing of pipes and fittings with one step UPVC solvent cement and testing of joints
complete as per direction of engineer in charge. Scope shall also including cutting, chasing the wall/beam by grinder cutter and making good the same.
Pipe Dia upto 50MM: UPVC (SCH 40)
Pipe Diameter above 50MM: UPVC (SCH 80)
3.11 The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical Rmt. 486.00 1270.00
specification etc. complete the job.
Product to compliance with occupational safety standards.
Providing and fixing male/ female screw ended full way lever operated forged ISI marked brass ball valves with brass body with forged brass hard chrome plated
ball / stem, union.Rated to temperature of 85 Deg C, The valves to be PN 10kgm class on CPVC or GI pipe lines. ( For cold water supply lines)
Providing and fixing male/ female screw ended full way lever operated forged ISI marked brass ball valves with brass body with forged brass hard chrome plated
ball / stem, union.Rated to temperature of 85 Deg C, The valves to be PN 10kgm class on CPVC or GI pipe lines. ( For cold water supply lines)
Providing and fixing male/ female screw ended full way lever operated forged ISI marked brass ball valves with brass body with forged brass hard chrome plated
ball / stem, union.Rated to temperature of 85 Deg C, The valves to be PN 10kgm class on CPVC or GI pipe lines. ( For cold water supply lines)
Providing and fixing male/ female screw ended full way lever operated forged ISI marked brass ball valves with brass body with forged brass hard chrome plated
ball / stem, union.Rated to temperature of 85 Deg C, The valves to be PN 10kgm class on CPVC or GI pipe lines. ( For cold water supply lines)
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Providing and supplying ISI mark CI D/F Butterfly Valves as per IS:13095 (Latest Edition) of class PN 10, including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
Lowering, laying and jointing in position C. I. D/F Butterfly valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic
3.16 testing, etc. complete. Nos. 33.00 1958.00
Providing and supplying ISI mark CI D/F Butterfly Valves as per IS:13095 (Latest Edition) of class PN 10, including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
Lowering, laying and jointing in position C. I. D/F Butterfly valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic
testing, etc. complete.
Providing and supplying ISI mark CI D/F Butterfly Valves as per IS:13095 (Latest Edition) of class PN 10, including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
Lowering, laying and jointing in position C. I. D/F Butterfly valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic
testing, etc. complete.
Providing and supplying ISI mark CI D/F Butterfly Valves as per IS:13095 (Latest Edition) of class PN 10, including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
Lowering, laying and jointing in position C. I. D/F Butterfly valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic
testing, etc. complete.
Supply, Installation, Testing and Commissioning of Gun metal 25 mm dia. air release valve.
Supplying, fitting and fixing of SS 316, Solenoid Valve, confirming to latest IS 8935, PN 16.0, with IP 67 logic controller, float switch, IP 67 Battery, with all accessories
viz. power and control cables, cabinets, hardwares specials, union, flange, cable upto tank, lower & upper level floats with, 3 Nos. brass ball valves screwed ends,
3.21 etc., to complete the job. Nos. 6.00 35450.00
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Supplying, installation, testing and commissioning of 50 mm dia. Heavy Quality Gun metal Pressure Reducing Valve with set of best quality having by-pass
arrangement consisting of the following :
3.22 1 No. pressure reducing valve screwed ends, Nos. 3.00 35110.00
3 Nos. brass ball valve screwed ends.
Woltman Type Bulk Water Meter- AMR Based:
Water Meter: 65 mm
Design, Supply, Installation, Testing, Commissioning of Woltman type Bulk Water Meter, CI/ Brass/ Bronze body material, totalizer made of copper can/ suitable anti
corrosive metallic material, totaliser metalic shall have 5 mm thick glass cover suitable against antifraud attempts, Flange End process connection, IP 68 protection
class, AMR Woltman Type Water Meter with removable mechanism, magnetic drive, dry dial, and be fitted with a low mass rotor which is parallel to the direction of
water flow and exhibits dynamic thrust relief, water meters complete with T Type strainer, ISO 4064 : 2005 with valid CE mark mentioning notified body number along
with MlD / OIML / ISO certification from a recognized International laboratory.
3.23 AMR System : Nos. 1.00 19888.00
AMR System shall be Walk By / Drive By mode, Wireless AMR trans-receivers shall be directly fitted on meter or inbuilt, IP 68 protection class, water meter & AMR
Module shall be of same brand, Single Command based AMR Reading and Minimum 90 days historical data retrive facility, alaram indication/ recording (for
Reverse Flow, back flow, Peak Flow,Minimum Flow, Low Battery Alram, Volume below threshold, Volume above threshold, Reverse Meter, Meter Stopped), Minimum
10 years of AMR module bateery life considering one no. communication per day.
Construction of valve chambers in brick or bell stone masonry,locally available in CM 1:6.Foundation concrete 150 mm thick in C.C. 1:4:8 of trap metal size 25 mm
to 40 mm thick,inside cement plaster in C.M. 1:3 and cement pointing outside in C.M. 1:3 and top cover of precast RCC slab 100 mma thick (with key hole in two
parts,each with handles or MS bar etc.complete as given size)UPto 1Mt. depth from G.L. to pipe invert incl.cpmplete civil works but excl. cost of excavation and
3.24 refilling, with cast in situ RCC slab in one sigle piece with fixing of CI-MH frame and cover (excl. cost of CI-MH Frame and cover) with 23 mm thick brick masonary Nos. 1.00 5138.00
wall in C.M.:1:6
Size of chamber 0.60M X 0.60M and 1M depth
Making point of new connection from Existing/ Municipal water supply line with all support, clamps, civil work, etc. required, providing suitable fittings, to connect to
Existing line and good the same as per engineer in charge. Work to be done including Liasoning cost.
IRRIGATION WATER SUPPLY NETWORK
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
4.01 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 275.00 90.93
joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
4.02 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and Rmt. 1196.00 146.65
joints and fixing the same with adhesive solvent, including cost of all materials.
Supply, installation, testing and commissioning of 20mm diameter Garden Hydrant with gun metal Ball Valve, Flexible hose Connection Provision and all required
accessories etc.
Supply, installation, testing and commissioning of Large dome type landscape drain is suitable for large planter areas and flower beds, where a thin layer of gravel
4.04 is used. It consists of a cast iron body, membrane clamp and a dome covered with a stainless-steel mesh. This product covers a greater drainage area and Nos. 12.00 3000.00
prevents the soil and stones from entering the drainage line
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
EXTERNAL SEWAGE NETWORK
Providing and supplying 100 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the
5.01 spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth & Rmt. 3.00 229.00
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
(From GT to First Chamber)
Providing and supplying 200 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
5.02 coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the Rmt. 100.00 771.00
spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth &
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
Providing and supplying 250 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
5.03 coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the Rmt. 430.00 1046.00
spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth &
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard
(i) Square mouth traps.
A)100mm x 100mm size P type
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Manufacture,supply and delivary of chemical fabricated RCC precast chambers with top cover as per specification and drawing attached with the tender
documents of sizes as mentioned below The delivary of chambers with clamps, nuts, bolts, and locking arrangment(without lock )is to be made to GWSSB store and
5.05 sites anywhere in Gujrat.The rates include all taxes, loading, carting, unloading, stacking including all taxes. Nos. 9.00 11087.00
Sewage chamber of size 900x900 depth 0.90m.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-
cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete 1:2:4 mix (1- Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete
including curing and festing (i) Inside size 900mm x 1500mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame
to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than
35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (3) B type depth 1.5 Metre
Providing and constructing Sewer manhole ,scraper manholes and untill house connection chamber , as per the type design in brick masonary in C.M. 1:5 and
inside amd outside 20mm thick plastering in C.M. 1:3 necessary 100 mm caping with reinforcement in R.C.C.M. 200 fixing C.I. steps and fixing manhole fram and
cover (But excluding suppling of manhole cover)over manholes and house connection chambers and fixing manhole covers (But excluding suppling of manhole
5.07 cover) over scraper manhole etc.complete providing and fixing safety chain wherever necessary as per the stipulation in the type design complete as per latest Nos. 13.00 33429.00
CPHEEO manul.(excl.excavation)
Manhole type "B" circular type having inside diameter of minimum 1500mm and for depth from1.5m to 4.0m(for 150 mm to 600 mm dia sewers)
Making connection to Municipal storm water line/ existing drain including breaking them in a systematic way with suitable excavation, dewatering, dismantling of
the RCC or masonry wall or pipe line, passing the plumbing storm water line in the existing structure either through masonry or RCC and providing suitable "Y" tee to
5.08 the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions testing etc. work Nos. 1.00 50000.00
to be done in the presence of municipal eng. including Liasoning cost. complete as per standard as directed by Engineer-in-charge to complete the job.
EXTERNAL STORM NETWORK
Providing and supplying 150 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
6.01 coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the Rmt. 125.00 396.00
spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth &
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Providing and supplying 200 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
6.02 coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the Rmt. 540.00 771.00
spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth &
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
Providing and supplying 300 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
6.03 coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the Rmt. 385.00 1401.00
spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth &
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
Providing and supplying 400 mm Inner Dia. Pipe of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing
ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the
departmental stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
6.04 coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the Rmt. 355.00 2153.00
spigot end, lowering the same into the trench at all level, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth &
alignment ,testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
Construction of Storm water chamber of size 450x450x600 mm (internal clear) making of RCC including excavation, backfilling, watering, soling, compaction,
Reinforcement etc. complete. It includes M 30 RCC work for walls , top slab and bottom slab as per the drawing, having Rubble soiling and 100mm thick PCC in M-
15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with adquate goliya at all sides. Top
6.05 shall be covered with FRP recessed Heavy Duty cover with Frame(450MMX450MM Clear Opening). It shall be completed with all respect in ture line level, plumb Nos. 18.00 14000.00
with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Construction of Storm water chamber of size 600x600x1000 mm (internal clear) making of RCC including excavation, backfilling, watering, soling, compaction,
Reinforcement etc. complete. It includes M 30 RCC work for walls , top slab and bottom slab as per the drawing, having Rubble soiling and 100mm thick PCC in M-
15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with adquate goliya at all sides. Top
6.06 shall be covered with FRP recessed Heavy Duty cover with Frame(600MMX600MM Clear Opening). It shall be completed with all respect in ture line level, plumb Nos. 27.00 16000.00
with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction
Construction of Storm water chamber of size 900x900x1500 mm (internal clear) making of RCC including excavation, backfilling, watering, soling, compaction,
Reinforcement etc. complete. It includes M 30 RCC work for walls , top slab and bottom slab as per the drawing, having Rubble soiling and 100mm thick PCC in M-
15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with adquate goliya at all sides. Top
6.07 shall be covered with FRP recessed Heavy Duty cover with Frame(600MMX600MM Clear Opening). It shall be completed with all respect in ture line level, plumb Nos. 25.00 19500.00
with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction
Construction of Storm water chamber of size 1200x1200x2000 mm (internal clear) making of RCC including excavation, backfilling, watering, soling, compaction,
Reinforcement etc. complete. It includes M 30 RCC work for walls , top slab and bottom slab as per the drawing, having Rubble soiling and 100mm thick PCC in M-
15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with adquate goliya at all sides. Top
6.08 shall be covered with FRP recessed Heavy Duty cover with Frame(600MMX600MM Clear Opening). It shall be completed with all respect in ture line level, plumb Nos. 25.00 24500.00
with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction
Making connection to Municipal storm water line/ existing drain including breaking them in a systematic way with suitable excavation, dewatering, dismantling of
the RCC or masonry wall or pipe line, passing the plumbing storm water line in the existing structure either through masonry or RCC and providing suitable "Y" tee to
6.09 the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions testing etc. work Nos. 1.00 50000.00
to be done in the presence of municipal eng. including Liasoning cost. complete as per standard as directed by Engineer-in-charge to complete the job.
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
PUMP AND EQUIPMENT WORKS
Providing and fixing S.S. water cooler of 80ltr storage capacity with 60ltr per hr. cooling capacity. Including inbuilt R.O.Plant consisting of considering the inbuilt
booster pump,dry run protection, water purification filters, piping, isolation valves, instruments supports, etc. complete & Medium Penetration UV. Including all Inter
connection piping and valve all comp. System as per drinking water IS stadard requirment. it is recommendate to provide blending system of water at attain TDS
7.01 level between 250-300 ppm. The suppliear has to also supply and installation of SS-316 storage tank - 80 ltr. capacity. Nos. 18.00 96495
WATER TRANSFER PUMP (For Domestic Water Supply)
Centrifugal Monoblock Transfer pump
Supplying, installing, testing and commissioning of Horizontal / vertial multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft,
SS-304/C.I. Base CED coating & head TEFC IE3 motor (with mechanical seal) with Company fitted with company compliance certificate. Vendor to submit
performance curves and technical catalogue with all GA Drawing of the proposed model for review and information.
Panel mounted PLC and HMI Based multi pump contoller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a
Panel with IP55 class with pressure sensor transmitter (each pump each VFD), diodes to indicate pump ready, pump running and fault and capable to
communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. All alarms should be displayed in the controller. System
7.02 should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel. Set 1.00 1400000
Set of accessories such as G.I headers for suction and discharge, control valves, non return valves, pressure transducers, pressure gauge, inter connecting power
and control cabling etc. complete.
Capacity per pump - 20.0 m3/hour, Head - 50 mt, 1 Set = 3 Nos. Pump (2 Working +1 Asist - cascade operation)
IRRIGATION PUMP
Centrifugal Monoblock Transfer pump
Supplying, installing, testing and commissioning of Horizontal / vertial multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft,
SS-304/C.I. Base CED coating & head TEFC IE3 motor (with mechanical seal) with Company fitted with company compliance certificate. Vendor to submit
performance curves and technical catalogue with all GA Drawing of the proposed model for review and information.
Panel mounted PLC and HMI Based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a
Panel with IP55 class with pressure sensor transmitter (each pump each VFD), diodes to indicate pump ready, pump running and fault and capable to
communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. All alarms should be displayed in the controller. System
7.03 should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel. Set 1.00 520000
Set of accessories such as G.I headers for suction and discharge, control valves, non return valves, pressure transducers, pressure gauge, inter connecting power
and control cabling etc. complete.
Capacity per pump - 7.5 m3/hour, Head -45 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Standby).
PLUMBING WORKS -RIVERSIDE,AHMEDABAD
Item No. Description Unit Rate Amount
Sump Drain Pump (For Basement Drain, Pump Room Drain)
Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts,
phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe.
(Pumps suitable to handle solids upto 50 mm size with C.I. body, SS304 shaft, SS impeller).
Pump Outlet shall be individual for both pumps and shall be connected to main drain line individually.
Electrical Starter panels complete with O/L Relay with Single phasing preventer feature, earth leakage relay, ON-OFF and Trip Indicating lamps, contactors Potential
free contacts for Building Automation System, interlocking, level controller with operational mode as one pump working at low level, both pumps at high level with
a hooter alarm and cut off at dry level, cascade operation, working / standby slelction, etc. suitable for the motor H.P. as specified below. The operations data for
all pumps shall be available on central BMS system
Capacity per pump - 15.0 m3/hour, Head -20 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Asist - cascade operation)
Sump Drain Pump (For Tunnel Drain)
Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts,
phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe.
(Pumps suitable to handle solids upto 50 mm size with C.I. body, SS304 shaft, SS impeller).
Pump Outlet shall be individual for both pumps and shall be connected to main drain line individually.
Electrical Starter panels complete with O/L Relay with Single phasing preventer feature, earth leakage relay, ON-OFF and Trip Indicating lamps, contactors Potential
free contacts for Building Automation System, interlocking, level controller with operational mode as one pump working at low level, both pumps at high level with
a hooter alarm and cut off at dry level, cascade operation, working / standby slelction, etc. suitable for the motor H.P. as specified below. The operations data for
all pumps shall be available on central BMS system
Capacity per pump - 45.0 m3/hour, Head -10 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Asist - cascade operation)
TOTAL PLUMBING AMOUNT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Vol. 1-Riverside Savories.pdf
Vol. 2 Technical Specification_RS_Ele and ELV.pdf
Vol. 2 Technical Specification_RS_Fire Protection System.pdf
Vol. 2 Technical Specification_RS_HVAC.pdf
Vol. 2 Technical Specification_RS_PHE.pdf
Vol. 2 Technical Specifications_RS_CIVIL.pdf
BOQ-CIVIL and PHE MERGED.pdf
BOQ-ELE and ELV ELEVATOR HVAC_MERGED.pdf
BOQ-FIRE FIGHTING_MERGED.pdf
RS_Tender_Drawing List.pdf
RS_Building Plans Sections Elevations.pdf
RS_Facade and Details.pdf
RS_Finishes and Details.pdf
01_RS_Site Plan.pdf
01_RS_Survey Basement and Sections.pdf
RS_Structural Drawings.pdf
01_Riverside Savories_Electrical and ELV Layout.pdf
01_Riverside Savories_FFTG Layout.pdf
02_Riverside Savories_Electrical and ELV Layout.pdf
02_Riverside Savories_FFTG Layout.pdf
03_Riverside Savories_Electrical and ELV Layout.pdf
03_Riverside Savories_FFTG Layout.pdf
Riverside Savories_Facade Lighting.pdf
Riverside Savories_HVAC Layout.pdf
Riverside Savories_Plumbing Layout.pdf
Download all tender documents and submit your bid