| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.1 CrAccepted-AOC SCT 3 H NO 2030 ROHTAK SCT 3 H NO 2030 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹2.1 Cr | 1 | Accepted-AOC Work Allotted |
| 2 | 2₹2.1 Cr+₹1.5 L (0.70%)Rejected-AOC 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | ₹2.1 Cr+₹1.5 L (0.70%) | 2 | Rejected-AOC Work Not Allotted |
| 3 | 3₹2.2 Cr+₹13.1 L (6.29%)Rejected-AOC 443 V P O LIWAN 132001 | KARNAL | HARYANA | 132001 | ₹2.2 Cr+₹13.1 L (6.29%) | 3 | Rejected-AOC Work Not Allotted |
| 4 | 4₹2.3 Cr+₹20.7 L (9.96%)Rejected-AOC | ₹2.3 Cr+₹20.7 L (9.96%) | 4 | Rejected-AOC Work Not Allotted |
| 5 | 5₹2.3 Cr+₹22.1 L (10.6%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹2.3 Cr+₹22.1 L (10.6%) | 5 | Rejected-AOC Work Not Allotted |
Tender Value
Refer Docs
EMD Value
₹5.0 L
Closing Date
4 Mar 2024, 11:00 amClosed
MOHD ASHIQUE
EE PHE Division (DandP) Sonipat
Estimate for W/S scheme construction of high level tank, filter bed, clear tank, rising main, pumping machinery and repair of S.S tank, boundary wall, Mandora and Mandori Tehsil Kharkhoda Distt. Sonipat - Estimate for renovation and upgradation of
2024_HRY_358152_1
20249EFF6E4A FEA2 42DA 8AE2 08F11B54D84A588PUH
Open Tender
Civil Works
Works
270 days
MANDORA
2 documents required · 2 mandatory
₹15,000
₹5.0 L
Yes
4 Apr 2024
24 Feb 2024
4 Mar 2024
24 Feb 2024
4 Mar 2024
24 Feb 2024
Amount
Supplying, erection, testing and commissioning of Horizontal motor pumping set of raw waer having Head 12.00 mtr. as requirements of discharge in 2000 LPM and power capacity in 10.00 BHP as ISI Marked
Panel Boards for Motors Supply, erection, testing and commissioning of wall mounted electrical L.T panel Board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items complete in all respect as per approved NIT. For raw water pump sets for 2000 LPM x 12 Mtr. Head = 2 No. a) Main switch 100 Amp 1 No. (LandT, Siemens, ABB) b) Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?LandT) c) Amp.mtr. 100x100mm range 0 to 100 Amp. 1 No. (AE/KAPPA/LandT) d) CT 100/1 No. (AE/KAPPA/LandT) e) VSS 1 No. and ASS 1 No. each of approved make f) SPP 1 No. approved make g) Motor starter , star delta 1 No. for 2000 LPM x 12 Mtr. head motor (LandT, Siemens, ABB) h) Capacity of suitable capacity i) Indicating Lamp- j) Change over switch Amp
Panel Boards for Motors Supply, erection, testing and commissioning of wall mounted electrical L.T panel Board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items complete in all respect as per approved NIT. For clear water pump sets for 1200 LPM x 45 Mtr. Head = 2 No. a) Main switch 100 Amp 1 No. (LandT, Siemens, ABB) b) Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?LandT) c) Amp.mtr. 100x100mm range 0 to 100 Amp. 1 No. (AE/KAPPA/LandT) d) CT 100/1 No. (AE/KAPPA/LandT) e) VSS 1 No. and ASS 1 No. each of approved make f) SPP 1 No. approved make g) Motor starter , star delta 1 No. for 1200 LPM x 45 Mtr. head motor (LandT, Siemens, ABB) h) Capacity of suitable capacity i) Indicating Lamp- j) Change over switch Amp...
Panel Boards for Motors Supply, erection, testing and commissioning of wall mounted electrical L.T panel Board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items complete in all respect as per approved NIT. For clear water pump sets for 900 LPM x 35.00 Mtr. Head = 2 No. a) Main switch 100 Amp 1 No. (LandT, Siemens, ABB) b) Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?LandT) c) Amp.mtr. 100x100mm range 0 to 100 Amp. 1 No. (AE/KAPPA/LandT) d) CT 100/1 No. (AE/KAPPA/LandT) e) VSS 1 No. and ASS 1 No. each of approved make f) SPP 1 No. approved make g) Motor starter , star delta 1 No. for 900 LPM x 35 Mtr. head motor (LandT, Siemens, ABB) h) Capacity of suitable capacity i) Indicating Lamp- j) Change over switch Amp
Panel Boards for Motors Supply, erection, testing and commissioning of wall mounted electrical L.T panel Board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items complete in all respect as per approved NIT. For clear water pump sets for 1800 LPM x 45 Mtr. Head = 2 No. a) Main switch 100 Amp 1 No. (LandT, Siemens, ABB) b) Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?LandT) c) Amp.mtr. 100x100mm range 0 to 100 Amp. 1 No. (AE/KAPPA/LandT) d) CT 100/1 No. (AE/KAPPA/LandT) e) VSS 1 No. and ASS 1 No. each of approved make f) SPP 1 No. approved make g) Motor starter , star delta 1 No. for 1800 LPM x 45 Mtr. head motor (LandT, Siemens, ABB) h) Capacity of suitable capacity i) Indicating Lamp- j) Change over switch Amp
Bidder Name
Amount
Kulbir Singh Contractor (GSTN-06ATZPS6352H1ZW) BID ID -1049533
Sunil Kumar (GSTN-06BMGPK6616K1ZU) BID ID -1051039
Krishan Kumar (GSTN-06ATZPK0120H1ZQ) BID ID -1051622
Surinder Singh Hooda (GSTN-06AABPH9599L2Z1) BID ID -1052175
Mukesh Rathee contractor(GSTN-NA)--1050729
kapil engineering company(GSTN-NA)--1050625
Krishan Kumar
kapil engineering company
Sunil Kumar
Kulbir Singh Contractor
Mukesh Rathee contractor
Surinder Singh Hooda
Krishan Kumar
Mukesh Rathee contractor
Kulbir Singh Contractor
kapil engineering company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .