Details of Pipelines Under Surat Base
Sr. No. Pipeline Section Pipeline length (KM) Pipeline Dia (Inch) Pipeline Thickness (mm) Pipeline Material Specification Design Pressure Commissioning Date Remarks
1 Hazira-Mora Pipeline 13.79 36 14.3 API 5L X52 47 23.11.2000
2 Cairn-Mora Pipeline 6.63 24 15.9,17.5 API 5L X60 PSL 2 95 31.08.2002
3 Kribhco -Mora Pipeline 2.81 12 6.4, 7.9 & 9.53 API 5L X60 PSL 2 49 18.01.2003
5 Mora -Utran Pipeline 25.45 12 6.4, 7.9 & 17.5 API 5L X60 ERW 35 20.06.2002 N2 Purged
6 Olpad-Utran pipeline 17.39 18 8.7, 10.3 & 12.7 API 5L GR X 65 LSAW 95 29.10.2009
7 Mora ONGC (PMT) 7.07 24 11.1,11.9,14.3 & 17.5 API 5L GR X 65 ERW 95 21.06.2006 N2 Purged
8 Mora-Vapi Pipeline 56.23 30 14.3, 17.5 & 20.6 API 5L GR X 65 PSL2 95 24.02.2007
9 Torrent power pipeline 21.77 24 11.1, 14.3 & 17.5 API 5L GR X 65 95 22.03.2008
10 Olpad ONGC pipeline 3.64 12 6.4, 7.1, 7.9 & 9.5 API 5L X52 ERW 14.71 16.07.2008 N2 Purged
11 Mora-sajod pipeline 58.11 24 11.1, 14.2 & 17.5 API 5L GR X 65 95 26.12.2004
12 Hazira-Ankleshwar Pipeline 73.2 18 11.9 API 5L GR X60 99 1999
Details of Pipelines Under Vapi Sub- base
Sr. No. Pipeline Section Pipeline length (KM) Pipeline Dia (Inch) Pipeline Thickness (mm) Pipeline Material Specification Design Pressure Commissioning Date Remarks
2 Ruby TOP, Alok Spur line 1.49 6” 6.4 API 5L Gr X52 ERW 49 24.02.2007
3 Welspun-Vapi 0.30 6” 6.4 API 5L Gr X52 ERW 49 24.02.2007
4 Eklera Srikrishna Spur Line 10.26 12" 6.4 API 5L Gr X52 ERW 49 16.02.2008
5 Adgam to Sarigam CGS Spurline 4.68 6” 6.4 API 5L Gr X52 ERW 49 16.02.2008
6 Sarigam CGS to Sarigam GIDC Spur Line 3.06 6” 6.4 API 5L Gr X52 ERW 49 16.02.2008
7 JBF SpurLine 0.28 6” 6.4 API 5L Gr X52 ERW 49 16.02.2008
8 Chandol to Vapi CGS Spurline 3.15 12" 6.4 API 5L Gr X65 ERW 95 12.04.2007
9 Vapi GIDC to Ukani Valve Chamber 5.47 12" 6.4 API 5L Gr X52 ERW 49 12.04.2007 Vapi GIDC Network
10 Agarwal Flow Tee to Agarwal Valve Chamber 2.06 6” 6.4 API 5L Gr X52 ERW 49 12.04.2007
11 Garnet Flow Tee to Garnet Valve Chamber 0.14 6” 6.4 API 5L Gr X52 ERW 49 12.04.2007
12 CNG Flow Tee to CNG Spur Line 0.36 6” 6.4 API 5L Gr X52 ERW 49 12.04.2007
13 Creative Flow Tee to Creative Spurline 0.34 6” 6.4 API 5L Gr X52 ERW 49 12.04.2007
14 Bhilag Flow Tee to Bhilag Valve Chamber 0.60 6” 6.4 API 5L Gr X52 ERW 49 12.04.2007
15 Raymond Spur line 1.56 6” 6.4 API 5L Gr X52 ERW 49 05.06.2007
16 Wellknown MDPE Connectivity 3.83 90 MM & 160 MM 9.35 & 5.11 MDPE SDR 17.6 7 31.07.2023
17 Silvassa Connectivity Spur Line 10.22 6" & 8" 6.4 & 7.9 API 5L Gr X52 ERW 49 29.01.2026
Details of Terminals Under Surat base.
Sr. No. Pipeline Section Type of Station Terminals Remarks
1 Mora-Sajod Pipeline RT+DT+Metering Mora Terminal
3 TOP+DT Bhadol
5 Mora-Vapi Pipeline SV Vanta
6 TOP Sachin TOP
7 SV + Metering Maroli
8 SV + Metering Bhattai
9 Mora-utran pipeline Plot Variav
10 Torrent Power pipeline TOP Torrent TOP
11 RT+Metering Torrent
12 Kribhco Mora Pipeline RT+Metering Kribhco
13 Cairn Mora Pipeline DT Cairn
14 Metering station L&T
15 Metering station GGL TOP
16 Hazira-Mora pipeline DT GSPC sun Petro
17 Metering station AMNS
18 Metering station(CMPL+HMPL) GSEG
19 OUPL/OOSPL Pipeline DT-RT Olpad Compressor
20 OUPL /MUPL Pipeline RT+Metering(OUPL) Utran
21 Hazira-Ankleshwar Pipeline DT+ Metering Zero point
22 Hazira-Ankleshwar Pipeline RT+DT+Metering GGL Mora
23 Hazira-Ankleshwar Pipeline SV Barbodhan
24 Hazira-Ankleshwar Pipeline SV + Metering Atodara
25 Hazira-Ankleshwar Pipeline SV Obha
26 Hazira-Ankleshwar Pipeline SV Alounj
27 Hazira-Ankleshwar Pipeline RT+DT+Metering Amboli
28 Hazira-Ankleshwar Pipeline RT Ankleshwar CGS
Details of Terminals Under Vapi Sub-base.
Sr. No. Pipeline Section Type of Station Terminals Remarks
1 Mora Vapi Pipeline (MVPL) IPS IPS Navagam
2 TOP+Metering Billimora
3 SV + Metering Olgam
4 TOP+Metering Gundlav
5 SV + Metering Attakpardi
6 TOP+Metering Raymond(Top)
7 TOP+Metering Atul
10 RT+Metering Eklara
11 Chandol to Vapi CGS Metering Station Vapi CGS
12 Eklara Shrikrishna TOP GHCL
13 RT Shrikrishna
14 Angam to Sarigam CGS TOP Sarigam
15 Sarigam CGS to Sarigan GIDC TOP+Metering JBF
16 Ruby Alok Pipeline TOP Ruby
17 TOP+Metering Welspun
18 TOP+Metering Alok/Morai
19 Raymond TOP to Raymond Metering Metering Raymond
20 Wellknown MDPE Connectivity Metering Wellknown
21 Silvassa Connectivity TOP Angam
22 Silvassa Connectivity Metering Bhilosa
GSPL TRANSMISSION LIMITED Natural Gas Grid
Annual Manitenance Schedule
Sr. No. Activity/ Description Frequency
1 Patrolling of Pipeline sections through GPS application (GSPL will provide the tablet/ mobiles with application)
1.1 Location Class 1 & Class 2 Q
1.2 Location Class 3 & 4 M
1.3 Location- High Consequence Area (HCA) M/AWR
1.4 Location-Critical HCA and ROW locations F/W/D
2.1 River Crossing Q
2.2 Rail/Road/Canal Crossing Q
2.3 Foreign Pipeline Crossing Q
2.4 Bubble leakage test of Station Piping Y
2.5 Checking of Casing Carrier System Q
2.6 Sub-Surface Gas Detection Survey AWR
2.7 Pressure drop test of integrated pipeline (As & when there is shut down or zero flow in particular segment) AWA
3 Monitoring & Maintenance of CP System
3.1 Monitoring & Maintenance of TR Unit M
3.2 Calibration of Meters & Transducers of TR Unit Y
3.3 PSP Monitoring Q
3.4 Instant pipe to Soil “OFF” potential Measurement at TLP of total pipeline section Y
3.5 Current Measurement in applicable TLP Y
3.6 Maintenance of Anode Ground Bed HY
3.7 Monitoring & Maintenance of Insulating Joint and Surge Diverter Q
3.8 Inspection of Interference Bonds Y
3.9 Checking of corrosion Coupon AWR
3.10 Checking of ER Probe/CTSU HY
3.11 CP Mitigation Works AWR
3.12 Integrity Check of Zinc / Mg Anodes for applicable TLPs Y
4 Monitoring and Maintenance of Instruments
4.1 USM Meter run/Turbine meter checks of Redundant Skid (Y) Y
4.2 Calibration of Master Instruments (Temperature Bath, Beamax, Dead Weight Tester, multifuncation calibrator) Y
4.3 Calibration of Field Instruments (DPT/PT/TT/PG/TG/DPG, etc.) Y
5 Maintenance of Plant Equipments
5.1 Maintenance of Scraper Traps, Pig Handling equipments & QOC Y
5.2 Maintenance of Filters & QOC HY / AWR
5.3 Maintenance of D G Sets,dewatering pump, Portable D.G. Sets and Fire engine with pump including jockey motor with pump including all ancillaries HY / AWR
5.4 Maintenance of Valves HY
5.5 Maintenance of Actuators HY
5.6 Overhauling & Calibration of Safety Valves & CRVs Y
5.7 Calibration of Safety Valves in actuator valve cylinder Y
5.8 Maintenance of Pressure/Flow control valve Y
5.9 Checking of Pig Signal Indicator Y
5.1 Third party inspection of 1 no. EOT Crane (15 Ton.) including Chain Pulleys at GSPL Mora terminal & Chain Pulley block at GGL Mora terminal with load testing (Testing Certificate shall be issued from Competent Person (Form-10)) under Surat Base. Y
5.11 Checking of Above Ground Pipe thickness Y
5.12 Visual Inspection of Flange Gaskets, Nuts, Stud etc. and application of Molykote Grease etc HY/AWR
5.13 Calibration of Equipment & Accessories, Ultrasonic Thickness Gauge, Vernier Digital Caliper, Micrometer gauge, LEL Detector/O2/CO, Lux & dB Meters. (NABL Certified Laboratory only) Y
5.14 Measuring of vibration/pulsation & sound in Metering Skid Systems Y
5.15 Checking and Maintenance of Indirect Water bath heater (Heating Skid) with all installed instruments at Surat Base. Q
6 Electrical Equipments
6.1 Maintenance of Electrical & Instrument Panels HY
6.2 Comprehensive Maintenance of UPS System HY / AWR
6.3 Maintenance of Battery Bank HY
6.4 Visual inspection & General cleaning of Battery Banks including Eye Washer. M
6.5 Monitoring & Maintenance of Earth Pits (Conventional type as well as Chemical back fill compund type) HY
6.6 Cleaning of Cable Trench Y
6.7 Maintenance of AC Units Q/AWR
6.8 Maintenance of Area lighting system(Outdoor) and Indoor lighting and Fans. HY/AWR
6.9 Maintenance of Solar lighting system HY/ AWR
6.10 Maintenance of Automatic Voltage Regulator HY /AWR
6.11 Checking and Sealing of Junction Box Y/AWR
6.12 Inspection & Maintenance of Flame Proof Lighting Fixture HY
6.13 Checking of Portable Electrical Equipment Q
6.14 Calibration of Multimer, Clamp Meter, Earth Tester, Insulation resistance tester, through NABL Certfied Laboratory OR Approved Authorised Service Agency. Y
6.15 Maintenance of Inverter and its Batteries Q
6.16 Maintenance of LT breaker Y
6.17 Maitenance of transfomer, Testing of transfomer & Oil testing Y
6.18 Maintenance of HT panel including 11 KV HT breaker Y
6.19 Certification of Electrical system through Electrical Inspector Y
7 Fire & Safety
7.1 Checking & Calibration of Gas Detection System Q
7.2 Checking & Maintenance of Fire alarm & CO2 Flooding & Clean Agent System (FM200) Q
7.3 Checking & Maintenance of Fire Extinguishers Q
7.4 Checking of First Aid Box & PPEs Q
7.5 Monitoring of emissions environmental, ambient air & stack monitoring Q/HY
7.6 Noise level monitoring and illumination measurement Q/HY
7.7 Drinking water testing HY
7.8 Hydrotesting of fire delivery hose at GSPL Mora terminal & GGL Mora terminal. HY
7.9 Testing, checking and maintenance of Rescue boat (01 nos. at Mora) Q
7.10 Testing, checking and maintnenance of Fire hydrant system (Diesel engines, pump, NRV, isolation valves, hydrant posts, monitors, hose boxes, delivery hose, short branch and is associated facilities) at GSPL Mora terminal & GGL Mora terminal Monthly/AWR
7.11 Testing, checking and maintnenance of Water mist trolley & Foam trolley Y/AWR
8 General Activities
8.1 Health Checking of U/G installations including valves on sample basis (Every year max.2 location per Base and 2 locations per Sub-base) 5Y/ AWR
8.2 Peel-off test for checking Cathodic disbandment on sample basis (minimum one number peel off test per pipeline section per year) Y / AWR
8.3 Maintenance of RO & Water Cooler system Q
8.4 Pest control in Terminal Buildings (Office, Control Room,Electrical room, Battery Room, DG Room, CO2 Room, Store etc.), Process Area, Open Spaces etc to ristrict entry of rats, snake repellant treatment, lizard, crockroaches, Honey comb removal, Rodent bait station etc.) Q/AWR
8.5 Anti-termite Treatment in Terminal Buildings (Office, Control Room,Electrical room, Battery Room, DG Room, CO2 Room, Store etc.), Process Area, Open Spaces etc Y/AWR
8.6 Paintaining of Pipe Support (terracotta) AWR
8.7 Inspection of Under Ground Valve and Chamber & Cleaning of Chamber HY
8.8 Site survey and supervise GSPL pipeline crossings by any 3rd party operator, coordinate & liasioning for safe execution of crossing. AWR
8.9 Assistance for manpower support for pigging & ILI activities AWR
8.1 Pipeline awarness program for villagers/ Public/Local /Authorities/Emergency Responders Q
8.11 Mock Drill - Internal Q
8.12 Mock Drill - External Y
8.13 Monsoon Preparedness for all terminals as per GSPL checklist Y
8.14 Cleaning of underground and overhead water tanks Y
8.15 Cleaning of fire water tank at Mora terminal (Capacity 3.25 lakh liters) & GGL Mora terminal (Capacity 14 Lakh ltrs.) Y
8.16 Visit of Unmanned stations Q
10 Pipeline Integrity Management System
10.1 Population Density Index (PDI) Survey (max.100 Kms to be considered per year). AWR
10.2 Cleaning Pigging through HD foam pigs, 2/4 cup batch pig. (max. 100 Kms to be considered per years). AWR
10.3 DIG verification of pipeline sections (max. 7 location per Year) AWR
10.4 Hydrotesting of pressure vessels at factory act terminals (2 location in Surat) AWR
10.5 CIPL Surevy 5Y/ AWR
10.6 DCVG/ CAT Survey AWR
10.7 QRA One time
11 Monitoring & Maintenance of MDPE Network
11.1 Line patrolling W
11.2 Monitoring of Odorant system parameters D
11.3 Bubble leak checking of all joints Q
11.4 Maintenance and Functional checking of Odorant system including Solar panel, Battery and Control panel etc. Q
11.5 Lock Pressure test of MDPE network HY
11.6 Maintenace of Valve Chambers of MDPE network HY
F - FORT NIGHTLY
HY- HALF YEARLY,
AWR- AS & WHEN REQUIRED
AWA – AS & WHEN AVAILABLE
Schedule of Rate (SOR), Rev-00 Tender Title: Appointment of Maintenance Contractor for Surat Base of GTL Gas Grid GTL Tender No: GTL/PROC/2026/08/O/501
Category of Registration in GST(Tick whichever is applicable)
Registered (Normal)
Registered (Composition Levy)
Type of Supply Under this Contract (Tick whichever is applicable)
Normal Supply of goods and services
Composite supply
1 The description given under the items of work in Schedule of Rates shall be deemed to include, wherever applicable, mobilisation ,labour, equipments, materials and fixing in position of all materials and equipments, disposal of wastages, desludging and allied operations at any stage of the work and all other labours and operations necessary whether specifically stated/implied or not, for the full and entire execution and completion of the relative works in all respects according to the contract. Cost of materials under the scope of Contractor’s supply & all other consumables/inputs required for carrying out the works & for permanent incorporation in the works for which rates are quoted in the "Schedule of Rates" shall be inclusive of all duties, taxes (excluding GST), etc. as applicable.
2 Base rates are provided, bidder to quote % (-) Discount or % (+) Accreation only. Bidder shall strictly quote as per price bid format (latest revision) only. Any bid not conforming to the price bid formats shall be liable for rejection.
3 Based on the SOR price, the contractor shall be liable to execute each SOR items at awarded rates as per the requirement given by GTL. In case contractor deny to execute any of the SOR item within the specified timeline given in the work request then the work shall be carried out by any other agency at the risk & cost of engaged ARC contractor. Cost of the same shall be recovered from the ARC contractor either from RA Bills or from Performanace Bank Garuentee (PBG).
4 Quantities mentioned in this SOR are estimated for evaluation purpose only. Payment shall be made at actual.
6 GTL reserves the right to reject any bid without any reason whatsoever.
Schedule of Rate (SOR), Rev-00 "Appointment of Maintenance Contractor for Surat Base of GTL Gas Grid" GTL Tender No: GTL/PROC/2026/08/O/501
Sr No Sr No Description Goods/Services Estimated Quantity Per Year Unit of Measurement Estimated Unit Rate SOR Total Amount (Excl. GST)
2.30 1 Maintenance of Filter: Valve Operations, Opening of filters, cleaning of filter elements/re-placement of the filter elements and box-up. The job is including valve operation for filter isolation & Venting, nitrogen purging and the air-blowing of filter element with compressed air, drying them in open yard for 3 hours, reinstall them if required change with new elements as per instruction of GTL EIC. Activity Inclusive of the Nitrogen purging with max. 7 M3 by using certified N2 Pressure Regulator from Cylinder. The job inclusive of all consumables, equipment's, tools, Manpower, transportation of filter elements from designated store.(HY)
2.30.1 1.1 Size up to 8" QOEC Type 42 Nos. 8,040 211592 337,680
2.30.3 1.2 Size from 10" to 12" QOEC Type 36 Nos. 8,040 211594 289,440
2.30.4 1.3 Size from 10" to 12" Flanged Door Type 2 Nos. 8,040 211595 16,080
2.31 2 Maintenance of Pig launcher/ receiver: Opening, cleaning and box-up of pig launcher / receiver of below sizes, including cleaning & replacement of "O" ring if required. Job includes supply & purging of N2.The job is including valve operation for Isolation & venting. O rings will be free issued by GTL. (Y)
3 Operation check of Manual/Gear/ Hydraulic operated Valves/ GOOV by manual & Pneumatic opening and closing in presence and as per instruction of GTL supervisor - as per size given up to 36" at various SV,RT,DT,IPS,Metering station (Including Consumables like Grease, Cotton Waste, etc.) No separate charges shall be paid for Manpower, Tools & Tackles, consumables used for this activities. (HY)
3.1 For SV Station 16 Per station 5,000 213422 80,000
3.2 For TOP station 14 Per station 3,000 213423 42,000
3.3 For IPS/DT/RT/station 72 Per station 15,500 213424 1,116,000
2.52 4 Safety valve calibration of sizes as given below with men, materials tools & tackles, consumables. The job including dismantling of safety valve from the filter equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders at height of maximum 3 meter, blinding of one upstream side of line flange of removed space of safety valve, Cleaning of all components, Lapping of nozzle ,change of body joint Gasket & disc if required, assembly of valve with repaired component, Calibration and Testing as found as left set pressure of safety valve at spot with all required materials tools & tackles. seat tightness required at 90% of test pressure & calibration of PG is required. Re-installation/erection of safety valve on equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders in position after testing/calibration. Consumable such as nitrogen, grease, testing gaskets & painting of Valves etc shall be arranged at site by the contractor for the above job. Gasket for the pipes / joint flanges shall provided by GTL. Issuing a certificate of calibration by a competent person. All type of transportation is included in the job (Y)
2.52.1 4.1 For Actuator Valve (Size below1") 60 Nos. 2,569 211617 154,140
2.240 5 Visual Inspection & Certifications (Form:- 11) of filter/pressure vessels as per factory Act through approved competent person.(HY) 16 Nos. 8,219 211662 131,504
CIV-114 6 ANTI TERMITE / PEST CONTROL TREATMENT Providing, applying and spraying of ant termite chemicals over termite mounds, at column pits, walls, trenches and basement excavations, RCC framed structures and RCC walls, on top surface of plinth filling, junction of walls and floors, soil under apron and plinth protection, including providing approved chemicals, tools, plants, instruments, consumables and labour. The quantity shall be measured in square meter as per instruction of EIC(M) 600 Per Station 1,000 102280 600,000
CIV-115 7 Monitoring of RoU by foot patrolling including Rail/Road/Canal/River crossing with casing carrier system with the help of GPS based mobile application along the route of pipeline.(M/Q) 3500 kms 400 213425 1,400,000
CIV-118 8 Bubble leak test of all flanges and leakage point in Station piping.(Y) 51 Per Station 2,500 213426 127,500
1 9 Checking of thickness for Station piping (Y) 45 Per Station 2,500 213427 112,500
3 10 Measurement of Vibration/Pulsation and noise monitoring of above ground piping system.(HY) 51 Nos. 2,500 213428 127,500
5 11 Pipeline awareness program for Villagers/Public, Authority. (Y) 150 Nos. 2,500 213429 375,000
7 12 Monitoring / Checking of Ch4 % at Common Vent line at various terminal.(M) 500 Nos. 300 213430 150,000
8 13 Above Ground pipe line Support checking.(HY) 90 per Station 750 213431 67,500
20 14 Maintenance of RO system and Water cooler system. Job is inclusive of supply and replacement of all parts & consumable as per recommendation by OEM authorised person or /distributer or skilled person(Q) 8 Nos. 5500 213432 44,000
42 15 Maintenance of Jockey Pump & Motor as per instructed by EIC.(Q) 4 Nos. 1000 213433 4,000
16 Monitoring and Maintenance of earthing system as per AMS (Annual Maintenance Schedule) by measuring earth pit resistance. The job includes cleaning of pit, checking and recording of earthing system circuit resistance by disconnecting Earth pit from the equipment's (provide alternative earthing if needed) and measure the earthing resistance of the disconnected pit by Winner's three pin method. The earth pit resistance value to be measured under two separate condition viz. (1) isolated from earthing grid and (2) when connected to earthing grid. After measurement it is re-connected and tightness of all connection to be confirmed. Anti corrosion gel /jelly shall be applied to all earthing connections checked, if required. Supply & replacement of nut bolts, if required. The work includes adding salt water& coal slurry, if required to the earth pits if required and replacement of nut bolts. The job shall be carried out and submission of reports on (HY) basis under a supervision of electrical supervisor. 1250 Per Pit 483 205707 603,750
17 Servicing of Air-Conditioners (includes cleaning of blower condenser fan, cleaning of air filter with vacuum cleaner, Evaporator coil, condenser coil and equipment, metallic/plastic body parts with soaked cotton cloths, Condenser ,Oil the motor as and when required, Checking of Voltage stabilizers / Timers and remote control units to maintain these in healthy conditions, Cleaning of Outdoor unit by Blower, Checking of working of compressor (Ampere of Compressor),Pressure checking of refrigerant, Checking the working of Stabilizer unit, one of the Quarter in a year shall have wet jet cleaning of both indoor & outdoor units. Checking of working of Capacitors of outdoor unit, Checking of drain pipe of outdoor unit, Checking the working of Flapper motor)(Q). 340 Nos. 817 209166 277,780
18 Servicing of DG Sets as per rating mentioned below ( includes physical inspection, checking for damaged parts, repairing of damaged parts, oil checking, trial run, synchronize checking, full load RPM checking, Voltage checking and adjustment, Lube oil Checking, battery checking etc. with men, tools and tackles as required). Cost of spare parts replaced shall be paid as per relevant SOR. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity.(HY)
19 Servicing of below mentioned electrical panel: The job shall include cleaning of the panel from outside and inside by vacuum cleaner & Manual, checking of operation of MCCB/ACB/MCB, Indication Lamp, Meters (KWh/Voltmeters/Ammeters/PF meters/Frequncy Meters etc.), Contactor, Fuses, CTs, Spacers etc. and sealing of the open cable entries by PVC/GI blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All required tools, tackles, manpower and PVC/GI blind plug shall be in contractor's scope. The job shall be carried out by qualified electrician.(HY)
19.2 Other Panel except MEDB 50 Nos. 3,000 210925 150,000
20 Maintenance of cable trench and cable trays which involves cleaning by Vaccum Cleaner & manual, cable dressing, cable identification etc.No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity.(Y) 1300 R. Mtr. 100 209261 130,000
21 Ni-CD Battery Bank maintenance including cleaning of battery by removing each cells from battery racks, dust/ corrosion removal from terminals & battery cells, Specific Gravity Checking, checking of cell voltage, Water level checking & refilling of DM water (if required), application of petroleum jelly on each battery terminal & links as per instruction of Engineer In charge. All required tools tackles like hydrometer, Multimeter, insulated spanners, etc., PPEs, DM water & other consumable are in the scope of contractor . Contractor shall submit report in the prescribed format. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity.(HY) 14900 Per Battery 30 209271 447,000
22 Operation of 75/125 KVA D.G sets on round the clock basis (24X7X365) by placing experienced personnel and maintain hourly logs, D.G. sets daily checks, diesel filling, water filling as per EIC requirement at Mora & GEL-Mora locations. 24 Month 120,000 210930 2,880,000
23 PSP field measurement & inspection / maint. of TLP. Execution of PSP monitoring by field measurement of parameters / reading from TLP’s, and submission of pipeline Section wise report(s) along with copy of hand written field report as per GTL’s prescribed format / procedures including checking and cleaning / maintenance of TLP's as specified in the scope of work and procedure. The scope also includes the reading collection / measurement of parameters of Casing soil Potential, AC potential, Foreign Pipeline Potential, Monitoring of Insulating Joints including Surge Diverter etc. [The average distance between two TLP is 1.00 km approx.](Q)
23.1 Hazira Mora Pipeline: Total No of TLP are 24 Nos 4 Each 9,600 213545 38,400
23.2 Mora Utran Pipeline: Total No of TLP are 31 Nos 4 Each 12,400 213546 49,600
23.3 Mora-Kribco Pipeline: Total No of TLP are 9 Nos 4 Each 3,600 213547 14,400
23.4 Mora-Sajod Pipeline: Total No of TLP are 77 Nos 4 Each 30,800 213548 123,200
23.5 PMT Pipeline: Total No of TLP are 13 Nos 4 Each 5,200 213549 20,800
23.6 Mora-NTPC pipeline: Total No of TLP are 3 Nos 4 Each 1,200 213550 4,800
23.7 Mora-Vapi Pipeline: Total No of TLP are 200 Nos 4 Each 80,000 213551 320,000
23.8 Cairn-Mora Pipeline: Total No of TLP are 15 Nos 4 Each 6,000 213552 24,000
23.9 Hazira- Ankleshwar pipeline. Total No. of TLP are 120 Nos. 4 Each 48,000 213553 192,000
23.10 Eklera Srikrishna Sarigam Pipeline: Total No of TLP are 26 Nos 4 Each 10,400 213554 41,600
23.11 Chandol-Vapi-Vapi GIDC Total No of TLP are 24 Nos 4 Each 9,600 213555 38,400
23.12 Raymond TOP-Raymond Receiving Total No of TLP are 5 Nos 4 Each 2,000 213556 8,000
23.13 Rubby-Welspun/Alok Total No of TLP are 4 Nos 4 Each 1,600 213557 6,400
23.14 TPPL diaX 22 Kms, 33 TLPs 4 Each 13,200 213558 52,800
23.15 OUPL dia X 17Kms, 32 TLPs 4 Each 12,800 213559 51,200
23.16 ONGC OLPAD dia X 3.5Kms, 7 TLPs 4 Each 2,800 213560 11,200
23.17 Silvasa Connectivity Pipeline: Total No of TLP are 27 Nos 4 Each 10,800 213561 43,200
24 Calibration of measuring devices (Multimeter-MM/ /Clamp Meter-CM/Earth Tester-ET (Y)
24.1 Digital Multimeter 5 Each 2,000 213434 10,000
24.2 Clamp meter 2 Each 2,000 213435 4,000
24.4 Earth Tester-ET 1 Each 2,000 213437 2,000
25 Visual Inspection & General Cleaning of Battery Bank (M) 156 Per station 1,500 213438 234,000
26 TR Unit Monitoring & Maintenance (M) 168 Per TRU 1,600 211428 268,800
27 TR unit meter and transducers calibration (Y) Minimum 5 panel meter and 03 transducers 14 Per TRU 5,000 210643 70,000
28 Anode Ground Bed Monitoring & Maintenance (HY) 28 Per Location 1,000 211429 28,000
29 ER Probe/CTSU/Corrosion coupon monitoring (HY) 4 Per Location 1,000 211430 4,000
30 Checking & sealing of all junction boxes including FLP JBs (Y) 36 Per Station 2,000 213441 72,000
31 Routine Maintenance & testing of HT transformer by certified agency i.e IR value, PI value, Ratio test, Magnetic balance test, Magnetizing current, vector group test etc.(Y) 2 Nos. 25,000 213442 50,000
32 Transformer Oil testing by NABL accredited lab i.e. Electric strength, water content, Acidity, Tan delta, resistivity, Sludge & sediments, Interfacial tension, flash point etc.(Y) 2 Nos. 10,000 213443 20,000
33 HT breaker maintenance & testing (Y) 1 Nos. 15,000 213444 15,000
34 HT panel including all relays , CT, PTs & meters maintenance & testing(Y) 1 Nos. 15,000 213445 15,000
35 LT breaker maintenance & testing including all relays & meters(Y) 7 Nos. 10,000 213446 70,000
36 Maintenance of RECD device in DG(HY) 4 Nos. 5,000 213447 20,000
37 ON-OFF Potential Survey: Yearly execution of ON-OFF Potential Survey(Y)
37.1 Hazira Mora Pipeline: Total No of TLP are 24 Nos 1 Nos. 12,000 213562 12,000
37.2 Mora Utran Pipeline: Total No of TLP are 32 Nos 1 Nos. 16,000 213563 16,000
37.3 Mora-Kribco Pipeline: Total No of TLP are 9 Nos 1 Nos. 4,500 213564 4,500
37.4 Mora-Sajod Pipeline: Total No of TLP are 77 Nos 1 Nos. 38,500 213565 38,500
37.5 PMT Pipeline: Total No of TLP are 12 Nos 1 Nos. 6,000 213566 6,000
37.6 Mora-NTPC pipeline: Total No of TLP are 3 Nos 1 Nos. 1,500 213567 1,500
37.7 Mora-Vapi Pipeline: Total No of TLP are 200 Nos 1 Nos. 100,000 213568 100,000
37.8 Cairn-Mora Pipeline: Total No of TLP are 16 Nos 1 Nos. 8,000 213569 8,000
37.9 TPPL diaX 22 Kms, 33 TLPs 1 Nos. 16,500 213570 16,500
37.10 OUPL dia X 17Kms, 32 TLPs 1 Nos. 16,000 213571 16,000
37.11 ONGC OLPAD dia X 3.5Kms, 7 TLPs 1 Nos. 3,500 213572 3,500
37.12 Hazira Ankleshwar Pipeline: Total No of TLP are 120 Nos 1 Nos. 60,000 213573 60,000
37.13 Eklera Srikrishna Sarigam Pipeline: Total No of TLP are 26 Nos 1 Nos. 13,000 213574 13,000
37.14 Silvasa Connectivity Pipeline: Total No of TLP are 27 Nos 1 Nos. 13,500 213575 13,500
37.15 Chandol-Vapi-Vapi GIDC Total No of TLP are 24 Nos 1 Nos. 12,000 213576 12,000
37.16 Raymond TOP-Raymond Receiving Total No of TLP are 5 Nos 1 Nos. 2,500 213577 2,500
37.17 Ruby-Welspun/Alok Total No of TLP are 4 Nos 1 Nos. 2,000 213578 2,000
38 Current Measurement in B type TLP(Y) 30 Per Location 500 213439 15,000
39 Integrity check of Zn/Mg anode(Y) 60 Per Location 50 213440 3,000
40 Calibration of secondary instruments such as Pressure Transmitter, Diff Pressure Transmitter, Temperature Transmitter, Pressure Gauge, Diff Pressure Gauge, Temperature Gauge, RTD at respective locations. (Trained manpower as well as master calibrator traceability with NABL certified lab and the calibrator shall have equal or better accuracy than the field instrument, in the scope of contractor).(Y)
40.4 TG of Range (0-100 degree C) 23 Nos. 737 206359 16,951
41 Removal and Re-installation of Turbine Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate to Meter, Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No separate charges shall be paid for manpower, consumables, lifting equipment's, valve operations, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.(Y)
42 Removal and Re-installation of Senior Orifice Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate to Meter, Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No separate charges shall be paid for manpower, consumables, lifting equipment's, valve operations, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.(Y)
43 Removal and Re-installation of Ultrasonic Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate to Meter, Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No separate charges shall be paid for manpower, consumables, lifting equipment's, valve operations, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.(Y)
44 Maintenance of Pressure/Flow control valve.(Y) 30 Nos. 2,500 213454 75,000
45 Checking of Pig Signal Indicator.(Y) 24 Nos. 500 213455 12,000
46 Calibration of Master Instruments(Multifunctional calibrator)(Y) 2 Nos. 45,000 213456 90,000
47 Calibration of Master Instruments (Temperature bath, Make: ametek type:RTC-156 BM RTD sensor)(Y) 1 Nos. 30,000 213457 30,000
48 Calibration of Master Instruments(Dead Weight tester, Model 580)(3Y) 2 Nos. 60,000 213458 120,000
49 Maintenance of Heating skid including checking of burners, pilot, Cleaning of flame arrester, checking of water level & checking of any leakages at Mora terminal(Q) 4 Nos. 2,500 213459 10,000
50 Checking and maintenance of Local control panel(LCP)9HY) 68 Nos. 1,500 213460 102,000
51 Checking and maintenance of CO2/FM200 flooding system(Q) 64 Nos. 3,000 213461 192,000
52 Illumination Monitoring at various GTL terminals at Night including required calibrated instrument and transportation up to the respective sites as per instruction of EIC.(HY) 78 per Station 1,965 210785 153,270
53 Environmental Monitoring by carrying out the Ambient air quality measurement for Particulate Matter (P.M10 & PM 2.5), Oxides of Sulphur (Sox) and Oxides of Nitrogen (NOx) and Noise level measurement at least 7 different spot ( i.e. 7samples) as per GTL format/EIC Instruction & GPCB norms in each SV station for 24 hrs and analysis of the result for submitting to GPCB as per scope of work and instruction by Engineer-in-charge. The scope includes noise level recording for HVS machines also. Noise level monitoring includes DG area during day & night time.(HY) 76 Per Station 5,137 206011 390,412
54 D.G Sets Stack monitoring as per GPCB norms from 51 KVA to 125 KVA(HY) 16 Nos. 4,409 210009 70,544
55 Portable drinking water analysis as per BIS-10500 (2012)(HY) 6 Per Sample 3,000 213462 18,000
56 Checking and maintenance of Fire Extinguishers(Q)
57 Inspection and updation of first aid boxes & PPEs (Items is charged as per separate SOR).(Q) 240 Per station 500 213466 120,000
58 Hydrotesting of fire delivery hose.(HY) 150 Nos. 500 213467 75,000
59 Cleaning of fire water tank at Mora terminal (Capacity 03.25 lakh litres)(Y) 1 Nos. 15,000 213468 15,000
60 De-ployment of experienced fire-man personnel on the round the clock basis by placing 1 person/shift of three shift per day and maintain hourly logs, Fire hydrant system daily checks, water filling as per EIC requirement at GTL, terminal 24 month 120,000 213469 2,880,000
61 Calibration of Portable gas detectors(Y)
62 Surface preparation of new piping/spool/Fittings, Steel Structural surfaces with Bristle Blaster machine, or blasting methods. Finish of surface quality SA 2 ½ and roughness 60 microns minimum by providing shot/sand of approved quality, shot/sand blasting equipment's & its accessories, manpower, material etc. The job also includes painting of piping spool including supply of paint and application of 1 coats of Neromastic 400(Mixture of Part-A & Part-B) or equivalent high build epoxy primer of 150 micron and 1 coats of Nerothane Enamel (PU)(Mixture of Part-A & Part-B) or equivalent Poly eurathene paint of golden/ cannery yellow/ any applicable colour of 150 micron or as instructed by GTL with of approved quality including stencilling of line numbers, pipe tagging, flow direction arrow, other lettering as found condition of pipeline as per instruction of GTL EIC. This includes covering of nut-bolts using masking tape and marking of thickness measuring spots during surface preparation & painting works 50 Sq. mtr 500 213473 25,000
63 Surface preparation of Installed (operational) piping/spool/Fittings, Steel Structural surfaces with manually scraping methods including manpower and material etc. The job also includes painting of piping spool including supply of paint and application of 1 coats of Neromastic 400(Mixture of Part-A & Part-B) or equivalent high build epoxy primer of 150 micron and 1 coats of Nerothane Enamel (PU)(Mixture of Part-A & Part-B) or equivalent Poly eurathene paint of golden/ cannery yellow/ any applicable colour of 150 micron or as instructed by GTL with of approved quality including stencilling of line numbers, pipe tagging, flow direction arrow, other lettering as found condition of pipeline as per instruction of GTL EIC. This includes covering of nut-bolts using masking tape and marking of thickness measuring spots during surface preparation & painting works 700 Sq. mtr 500 213474 350,000
64 Repair of Pipeline / Flange / RTD Thermowell/IJ/Valves Body at leakage portion or less thickness locations by supply and application of leak clamp which can be installed on line and injecting sealing material. The job includes cleaning of pipeline / flange / RTD Thermowell/IJ/Valves, installation of leak clamp or any other leak clamp which can be installed on line and injecting sealing material on pipes. The job includes the flange / RTD Thermowell/IJ/Valves and restore the field to its original conditions. The job includes man-power, transportation and other resources. This job shall be carried out by certified OEM / vendor only.
65 Peel-off test on existing buried pipeline to check the health of pipeline and corrosion on pipe surface. Job includes excavation, Dewatering& backfilling of required size. After inspection, cleaning, coating repair, holiday check, back filling and final clean-up. etc, as per drawing and direction of E.I.C. Survey is to be carried out on pipelines of dia. 6”, 8’’, 10", 12’’, 16", 18’’, 24’’, 30”,36" including man power, transportation, machinery, peel-off test equipment, temperature gun, etc. 2 Per Pit 19,320 213153 38,640
66 Installation of above ground valves(Ball/Glove/ Check) of various sizes in piping system including handling, blind removal providing temporary supports if necessary, Studs bolt loosening / tightening, gasket insertion and torque setting by torque wrench with all tools/tackles/manpower etc. of valves sizes, Hydra and other lifting equipment inclusive of scaffolding arrangement at site if required including valve operation. Gasket shall be provided by GTL.
66.1 Up to & including 1” NB 5 Nos. 446 208652 2,230
67 Dismantling of valves(Ball/Globe/Check) from the line and putting blinds / spool pieces etc., for various pipe sizes etc. including Stud bolt loosening, gasket changing, handling with all tools / tackles / manpower etc. of valves sizes. Gasket shall be provided by GTL.
67.1 Up to & including 1” NB 5 Nos. 446 207121 2,230
68 Dismantling or Installation of Blind Flanges from A/G piping for various pipe sizes including nut bolt removing & handling with all tools / tackles / manpower/machinery & consumables etc. and stacking all within radius of 250 Mts as per GTL EIC instructions.
69 Gas cutting, grinding, and bevelling of various diameter station pipes of upto Sch-80 (Sch-160 up to 2" pipe). The job inclusive of all manpower, transportation, consumables, equipment's, tools, NDT check of bevel end etc.
70 Dismantling of piping spool along with flanges from line for various pipe sizes and putting blind including nut bolt removing & handling with all tools / tackles / manpower/machinery etc and stacking all within radius of 250Mts as per GTL EIC instructions.(No separate charges shall be paid extra for manpower & equipment's used)
71 Installation of piping spool along with flanges for various pipe sizes including blind removal, nut bolt removing ,stud cleaning, tightening and torque setting by torque wrench & handling with all tools / tackles / manpower/ machinery within radius of 250 Mts etc as per GTL EIC instructions.(No separate charges shall be paid extra for manpower & equipment's used)
72 Supply and Installation of chequered plate of upto 6 mm thickness for trenches, platforms etc including application of red oxide primer and two coats of finish paint of approved quality.(No separate charges shall be paid for gas cutting, grinding & welding of edges of chequered plate & transportation of the same) The job inclusive of all consumables, equipment's, tools, labour etc. removal of existing installed chequered plate from Operating plat form, Pit, Etc 100 Sq. mtr 5,144 208899 514,400
73 Providing and fixing pre coated galvanized G.I. Sheet(0.6 mm thick trapezoidal profile) of approved colour on roofing and sides of Metering system or DG Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets complete and including all accessories. 100 Sq. mtr 1,086 208901 108,600
74 Providing & fixing hand railing with Class-B pipes on equipment's like filter, PRS, operating platforms, buildings etc. The job includes surface cleaning, supply and application of two coats of red oxide primer and two coats of finish paint of approved quality. The job also includes removal of existing damage railing wherever is required including cutting ,grinding etc. The job is to be executed as per the direction of the E.I.C. 100 Mtr.. 782 210102 78,200
75 Replacement by removing old gaskets including tightening and loosing of Flanges ,stud cleaning, tightening and torque setting by torque wrench with all tools / tackles / manpower/ machinery etc as per GTL EIC instructions. Gasket shall be provided by GTL at designated store.
76 Fabrication and installation of Above ground piping of grade ASTM A333 Gr.6 / API 5L/X65 & equivalent grade of different schedule including, handling, aligning, cutting, bevelling /edge preparation, installation of associated fittings / flanges, fit-up, tie-in, welding, Radiography, UT, DP, transportation of fabricated spool to location, temporary supporting, erection of different size of fabricated aboveground piping at all elevations including handling, temporary supporting etc. The job includes carrying out hydrostatic testing as per GTL approved procedure of completed Piping loop / Piping system as approved by Owner / Owner’s Representative to the specified pressures, providing all testing equipment's / instruments / accessories, blind etc. including Pressure recorder, Temperature probe, Temperature recorder. Dewatering, surface preparation & painting of Spool after successful completion of hydro testing is also including in scope. (Pipe/ pipefittings shall be issued by GTL at designated store.)
76.1 Pipe Wall thickness ranging from 6.4 mm– 8.56 mm 40 Inch. Dia. 1,500 210104 60,000
76.2 Pipe Wall thickness ranging from 8.57 mm– 17.4 mm 200 Inch. Dia. 1,768 210105 353,600
76.3 Pipe Wall thickness ranging from 17.5 mm– 32 mm 48 Inch. Dia. 1,983 210106 95,184
77 Re-conditioning of coating of underground gas pipeline after locating the pipeline as per the coating fault. The activity includes (a) Excavation to expose the line to suitable depth to expose the pipeline and provide working space around the pipeline.(b)Removal of existing coating by using scrappers etc. and cleaning the surface to fine finishes by power brush / suitable method.(c) Rectification of Coating of the defects by HEAT SHRINKABLE /DENSO MAKE after surface preparation by mechanical cleaning, primer application, wrapping of tape, edge preparation, holiday test etc.(d)Back filling the trenches and restoring the fields to the satisfaction of GTL. Cleaning ROU of any debris etc.(e) The supply of all consumables, utilities, dewatering Pump equipment, and all manpower required, pipe cleaning and surface preparation, repairing of coating defects (resulting in holiday in coating) and testing including all handling, transportation, etc. included in this schedule of item.(f)any crop compensation to the land owner / farmers shall be in the scope of GTL. (No separate charges shall be paid for manpower, consumables, equipment's, tools used for this activity)
77.1 DENSO / RayChem MAKE TAPE (Tap width 150 mm with inner layer with 50 % of overlap & outer layer with 50 % of overlap) 100 Sq. mtr 8,040 213177 804,000
77.2 HEAT SHRINKABLE Sleeve 8 Sq. mtr 8,122 208934 64,976
77.3 COATING REPAIR PERP HTLP 80 10 Sq. mtr 7,678 213179 76,780
77.4 COATING REPAIR FILLING MATERIAL MASTIC 12 Sq. mtr 7,900 213180 94,800
78 Condition Checking of underground sectionalizing Valves/ Tap off including it's by-pass valves and associated underground piping. The job includes a) Removal of gravels, Excavation( (Removal of gravel from Process Area, Manual Excavation) and making trench of appropriate size, required for checking of valves and under ground piping. Excavation to be carried out segregating sand, gravel, mud, PVC so that backfilling can be done appropriately. Thickness measurement of valve body as well as underground piping, b) Reconditioning of coating using R-95 Epoxy or equivalent coating to be claimed as per relevant SOR (Supply & Application). c) Holiday test for the valve body and underground piping d) Backfilling & restoration as found condition, e) This include removal and re-installation of PT/TT/PGD/FPL stand/pole, if required. f) The supply of all consumables, utilities, equipment, and all manpower required, valve cleaning and surface preparation, repairing of coating defects (resulting in holiday in coating) and testing including all handling, transportation, etc. included in this schedule of item. This includes Supply & replacement of Polyethylene sheet (sheet 0.5 mm thk) during the course of valve checking.
79 Checking of above ground pipeline supports by lifting the pipe section, providing temporary supports by standard Engineering practises and rectification measures like application of paint to be carried out and fibre sheet of proper dimension shall be placed. Any rectification in support shall be paid as per the relevant SOR. (Measurement shall be done on the basis of Dia of Pipeline and Nos. of Support to be checked) No separate charges shall be paid for Manpower, Tools & Tackles, consumables used for this activities.
79.1 2”NB 5 Per support 848 210815 4,240
79.2 3”NB 5 Per support 848 210816 4,240
79.3 4”NB 5 Per support 924 210817 4,620
80 Painting of Valves (Ball, Globe & Check) of different sizes with two coats of finished paint of epoxy paint of suitable colour of approved make as per the GTL Vendor list attached with this tender to give an even shade after proper scraping of existing paint by power brushing or suitable method and clearing of surface free from foreign materials as per the instructions of GTL EIC. The job is inclusive letter writing of tag Number as per direction of EIC
81 Painting of Actuators (excluding SS and Panel Part) installed on different sizes of valves with two coats of finished paint of epoxy paint of suitable colour of approved make as per the GTL Vendor list attached with this tender to give an even shade after proper scraping of existing paint by power brushing or suitable method and clearing of surface free from foreign materials as per the instructions of GTL EIC.
82 Supply and Installation of "U" Clamps of CS material of standard type with NPT at bolting end including polyethylene insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. This include removal of old rusted U Clamps.
83 Load testing of EOT/Mono Rails of various capacities including supply of dead weight block of required capacity and submission of certificates of competent authority. The job includes examination and testing of lifting tools and tackles as per Factories Act,1948 and providing certificate in FORM No:10 (Prescribed under rule 60) by competent person who has certificate possessing by issued Factory Inspector . Tested date, safe working load, due date etc shall be written on the equipment at end of testing as per instruction of Engineer In-Charge. No separate charges shall be paid for manpower, consumables, lifting equipment's, transportation of test load, tools & tackles used during execution of this activity.
84 Hydro testing of, Filters as per GTL Requirements( Test Pressure- 150 Barg, Holding period - Min 4 Hours). Test includes Complete hydrostatic test arrangement i.e. test facilities with high pressure hose pipe, Calibrated digital pressure gauge, suitable manifold and any special requirement to conduct the hydrostatic test at site location and submission of reports. Required Valve operation, blinding if required, removal of filter elements, re-installation of filter elements after completion of Hydro- test. No separate charges shall be paid for manpower, consumables, lifting equipments,water, tools & tackles used during execution of this activity. The job includes examination and testing of pressure vessel as per Factories Act 1948 and providing certificate in FORM No:11 (Prescribed under rule 61) by competent person who has certificate possessing by issued Factory Inspector. Tested date, Test Pressure, due date etc shall be written on the equipment at end of testing as per instruction of Engineer In-Charge.
84.1 up to 12" dia size Filter 1 Nos. 11,816 213121 11,816
84.2 14" to 20" dia size Filter 1 Nos. 18,494 213122 18,494
84.3 24" to 30" dia size Filter 1 Nos. 20,035 213123 20,035
84.4 36" to 60" dia size Filter 1 Nos. 28,254 213124 28,254
85 Hiring of following equipment's for doing any emergency work with all required valid test certificates. The period of hiring will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will not be paid. Normal working time per day will be 8 Hrs. Rate for idle time shall be 50%. Night is not included in idle time except if works will continue in night. Hiring rates is inclusive of diesel, operators, maintenance cost, loading/unloading of equipment's by Hydra/manual at site.
85.1 Dewatering pump of capacity 20KL with required capacity D.G.Set 80 Per Hrs. 699 207136 55,920
85.2 Air Compressor of capacity 75 CFM with required capacity D.G.Set 8 Per Hrs. 585 207162 4,680
85.3 Hydra of lifting capacity 10MT to 15 MT along with required wire ropes & D-Shackle 300 Per Hrs. 1,541 102223 462,300
85.4 Tractor Mounted Pneumatic Type Rock Breaker 1 Per Hrs. 1,078 102228 1,078
86 Schedule of rates for extra works for manpower supply (Total 26 day per month is counted in per month SOR)
86.1 Qualified Welder 1 Per 8 Hr. 2,398 208224 2,398
86.2 Fitter/Grinder 10 Per 8 Hr. 1,283 208225 12,830
86.3 Electrician/ Wireman 30 Per 8 Hr. 1,283 208223 38,490
86.5 Helper/Unskilled Labour 200 Per 8 Hr. 616 208220 123,200
86.9 Draftsman / Skilled Stencil Maker 60 Per 8 Hr. 3,000 213475 180,000
86.10 Mechanical technician 300 Per 8 Hr. 1,200 213476 360,000
86.11 Instrument technician 100 Per 8 Hr. 1,200 213477 120,000
87 Preparation/Updation of As-Built drawings like P&ID, GAD, Plot Plan, ISO, Alignment Sheet, Earth Pit Layout, Cable Root, Electrical Single Line Diagram etc. (including taking of required measurement from Site) after modifications(.with submission of editable Auto-Cad file and one printed copy)
87.3 Plot Plan 15 Per dwg. 4,824 212618 72,360
87.5 Alignment Sheet 5 Per dwg. 4,824 212620 24,120
87.6 Earth Pit Layout 7 Per dwg. 4,824 212621 33,768
87.7 Cable Root 7 Per dwg. 4,824 212622 33,768
87.8 Electrical Single Line Diagram 5 Per dwg. 4,824 212623 24,120
87.9 Hazardous Area Classification 15 Per dwg. 4,406 213478 66,083
87.10 Crossing drawing 1 Per dwg. 4,406 213479 4,406
88 Supply and replacement of Gland packings of Globe Valves (from 2" to 12" ). Gland Packing to be purchase from GTL Approved Vendor/OEM of Valve. 5 Nos. 1,307 501461 6,535
89 Servicing & Maintenance of EOT Crane (Overhead Crane) of up to 15 tonne capacity mentioned below for General Servicing & checking of Long Travel, Cross Travel & Hoist Mechanism including following activities 1) Checking of Travelling speed for LT,CT & Hoist. 2) Checking the condition of Main Hoist Wire Rope 3) Operational check for Gear box of LT,CT & Hoist to check the condition of Gears & Oil. 4) Cleaning & checking of Girder 5) Checking of Brake Disc/Brake Pads/Brake Liners 6) Checking of Push Button Controls, Operation of Motors, Variable Frequency Drives (VFD), Limit Switches, Breaking Resistors & Bus Bars. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity. 1 Nos. 21,894 210929 21,894
90 Overhauling of the jockey Centrifugal pump and Main centrifugal pump of the Fire hydrant system. 5 Nos. 21,581 210064 107,905
91 Supply & installation of FRP sheet(5 mm) as per thickness mentioned below of approved colour on roofing and sides of Metering system or DG Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets complete and including all accessories. Job includes removal of existing sheets if any. 200 Sq ft. 407 500679 81,400
92 Supply & installation of Teflon sheet as per thickness mentioned below for Pipe Support (Between pipe and Support
93 PAUT Testing as per instruction of EIC and submission of report .The job shall be inclusive of coating removal as per the requirement of testing. 1 Location 49,531 211703 49,531
94 Supply, transportation, fabrication and erection of MS steel section (Frame) of various sizes along with required fasteners (plate, angle, tee, channel, beam etc) for installation of panel. Rate also includes the surface cleaning by a suitable method, Supply and application of two coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy of grey colour / colour as specified by GTL of approved make, the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement. Job inclusive of labour, machinery etc.(No separate charges shall be paid for transportation of fabricated structure, manpower, equipment's used during execution of this activity) 2000 per Kg 123 205425 246,000
95 Supply & filling Rubble Soiling (200-250 mm thick) in trench, bottom of foundations for FML skid/piping supports etc up to required level complete as per drawings, specifications and as directed by EIC. No separate charges shall be paid for manpower, consumables, equipment's, handling, tools & tackles used during execution of this activity. 100 Sq. mtr 1,284 211773 128,400
96 Painting, Numbering & Lettering of existing pipeline markers and painting of vent pipes in cased crossings including Supply of paint and application of 2 coats of red-oxide primer and 2 coats of zebra strip (black and golden yellow stripes) of approved quality to give an even shade after proper scraping of existing paint and clearing of surface free from foreign materials. The rate are including man/ material and transportation to the position / site.
96.1 Direction Marker 125 Nos. 910 208825 113,750
96.2 Warning Marker 250 Nos. 910 208826 227,500
96.4 Navigation Marker 7 Nos. 910 208828 6,370
97 Supply, transportation & installation of Navigation Marker (of size 5m X 2m with required channels for grouting) at River Crossing including painting, stencilling the logo, arrow markers & signs as per specimen drawing DRW. No. GTL-AMC-STD-10 enclosed. The Job includes supply of all materials for grouting in 1:3:6 PCC mixtures to correct line, level and direction. The work also includes transportation to site of installation, necessary excavation for grouting of post, cleaning ground portion from the ground level & restoration. 1 Nos. 39,883 210985 39,883
98 Supply, transportation and installation of new direction marker / warning Marker on pipeline RoU as per DWG. No. GTL-AMC-STD-10 / GTL-AMC-STD-11 including supply of all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra colour (black and golden yellow strips) of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation up to required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation, lifting equipment's, handling, tools & tackles used during execution of this activity. 60 Nos. 6,837 207220 410,220
99 Supply, transportation and installation of new FRP direction marker / warning Marker with RCC pole on pipeline RoU as per DWG. No. GTL-AMC-STD-10 / GTL-AMC-STD-11 including supply of all materials cleaning, Excavation up to required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation, lifting equipment's, handling, tools & tackles used during execution of this activity. 30 Nos. 3,000 213480 90,000
100 Supply, Transportation and installation of new K.M. Marker as per DWG. No. GTL-AMC-STD-09 including supply of all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra colour (black and golden yellow strips) of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation up to required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation, lifting equipment's, handling, tools & tackles used during execution of this activity. 30 Nos. 8,081 207226 242,430
101 Supply, transportation and installation of pre-cast RCC (1:2:4) RoU boundary markers on pipeline RoU as per drawing No.- DWG. No. GTL-AMC-STD-04 or as per direction of E.I.C. The work also includes necessary excavation of pits, grouting of post & restoration. No separate charges shall be paid for manpower, consumables, transportation to site location, tools & tackles used during execution of this activity. 600 Nos. 1,481 205415 888,600
102 Cleaning of valve chamber / condensate pit including de-watering, cleaning of moisture content, sludge removal, cleaning with fresh water, drying of cleaned valve chamber or condensate pit and disposal of sludge and debris within a lead of 1 KM. 12 Per Chamber / PIT 1,961 210991 23,532
103 Providing stone pitching average 230-250mm thickness with the joints filled up with cement mortar of 1:6. Including preparation of the bed slope, cutting and filing earth, compacting to the 90% of proctor's density, filling the joints with 1:6 cement mortar pointing the joints with same mortar complete in all respects including the supply of stone boulders, all materials, labour and consumables etc. as directed by engineer-in-charge and as per the specifications. 7 Sq. mtr 1,150 208619 8,050
104 Shifting of Pipeline markers (i.e. Warning marker / Direction marker / KM marker / Arial marker / OFC marker / Navigation marker etc.) from its existing location , the the job includes supply of all materials required to complete the removal of existing marker and re-installation works including excavation, fixing of boundary stone/pipeline marker on pipeline RoU in PCC 1:3:6 to correct line & level, restoration etc. Complete job as per specification and direction of E.I.C. 10 Nos. 4,739 212646 47,390
105 Supply and installation of concertina Razor wire to replace the existing damage portion fencing of dia. 500mm of GI barbed wire 12SWG in helical shape of wire to wire distance 250mm spacing in existing boundary wall with 8 nos(4 on each side) horizontal wiring at 45 degree spacing each as described in drawing. The 'Y' Steel Structure if used shall be claimed as per relevant SOR. New structure work includes sand blasting , primer and 2 coats of aluminium paint for structural work. 200 R. Mtr. 925 102024 185,000
106 Supply and installation of Barbed wire( 6 Wire) fencing to replace the existing damage portion mm of GI barbed wire 12SWG in existing boundary wall. The Steel Structure if used shall be claimed as per relevant SOR. New structure work includes sand blasting, primer and 2 coats of aluminium paint for structural work and existing with single coal of aluminium painting 200 R. Mtr. 196 102025 39,200
107 Supplying and laying in position of RCC NP3 class pipes with collars, confirming to IS: 458 for pipe culverts, cable crossing, road crossing etc. including cutting the hume pipe if necessary, lowering, laying in position to proper levels, slopes etc. caulking the joints with spun yarn soaked in neat cement slurry and finishing with cement mortar 1: 2 (1 Cement: 2 Sand) curing etc. all complete as per drawings / specifications and directions of Owner/Owner’s Representative. Rate is included the cost of excavation up to 1.2-meter cover and backfilling of earth. Providing bedding concrete of PCC (1:4:8) 75 mm thick and backfilling with good earth
108 HAZOP Study by independent HAZOP chairman of experienced agency. Prior to start the work, the contractor shall submit credential of HAZOP chairman for approval of GTL. 1 Per Day 43,789 211970 43,789
109 Rough plaster 1:4 cement-mortar which includes groove of 15 to 25 mm Width X 15 mm Depth in plastering at all heights, levels and places, including scaffolding, chipping, roughing up the concrete , curing and finishing 25 Sq. mtr 318 212090 7,950
110 Water body Bank protection: By Supply of material and construction of Gabions if the sloping side of the water crossing & embankments is between 10 and 45,the gabions mattresses will be constructed by works include, fabricate hexagonal mesh of opening of size 100x120 mm made of 3.0 mm dia galvanized steel wires with all selvedges finished with 4.0 mm dia galvanized wires. Gabions mattresses unit i.e. diaphragms of size 2 m x 25 cm thick with length varying from 4.0 m to 6.0 m as per site requirements. In any case, mattresses length will not be more than 60 m. Mattresses shall be filled using solid hard rock boulders (grade from 75 mm to 150 mm) overfilling up to 40 mm will have to be done to allow for settlement. Gabions mattresses diaphragms shall be laced laid and placed at required locations as per detailed approved drawing. 150 Cu Mtr. 5,294 212223 794,100
111 Supply and installation of laminated plywood sheet up to 10mm thick in doors, windows as per applicable colour as per direction of EIC. 1 Sq. mtr 2,452 212118 2,452
112 Supply, installation, testing and commissioning of UPVC, male or female threaded isolation valve (Handle Valve), with necessary fitting etc., to complete the job. Job is also inclusive of plaster braking (FOR external / internal work)(SCH 80 ASTM )
113 Dismantling of damaged tiles from building including staking of serviceable materials and disposal of unserviceable material within 100 mtr lead. The job including temporary covering of panels / equipment's installed in room with Polythene sheet of contractor material. 1 Sq. mtr 185 212145 185
114 Removal of excavated sand / debris/soil and disposal of material from specified location up to 5 Kms of area 1 Cu Mtr. 189 212146 189
115 Providing and fixing Indian style W/C of reputed make complete with connection to sanitary. Rate shall include all internal plumbing (hot & cold) cost inclusive of all necessary items to complete the job as directed by Engineer – in – charge 1 Nos. 6,702 212148 6,702
116 Providing and fixing European style W/C of reputed make with connection to sanitary W/C line. Rate shall include all internal plumbing cost inclusive of all necessary items to complete the job as directed by Engineer – in – charge 2 Nos. 7,285 212149 14,570
117 Providing and fixing Flush tank complete with connection to sanitary W/C line. Rate shall include all internal plumbing cost inclusive of all necessary items to complete the job as directed by Engineer-in-charge 2 Nos. 3,541 212150 7,082
118 Providing & fixing in position 15 mm C.P. brass bib cocks. 1 Nos. 2,452 212964 2,452
119 Providing & fixing in position 15 mm C.P. brass swivel (swinging) sink cocks. 1 Nos. 2,452 3000585 2,452
120 Providing & fixing in position 15 mm C.P. pillar cock with connecting pipes ,nuts washers, etc complete. Pillar Cock - long neck with Aerator, if required. 1 Nos. 925 213216 925
121 Providing & fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. 1 Nos. 925 212160 925
122 Providing & fixing flush valve with necessary fittings. 1 Nos. 2,398 212161 2,398
123 Providing & Fixing Jet Spray/Hand faucet – with all fittings & fixtures. 1 Nos. 599 212162 599
124 Providing & fixing of concealed stop cock with wall flange and necessary pipes and fittings etc. complete., for the following sizes. Stop Cock.
125 Waterproofing of the terrace of CR/Guard Room building, including terrace cleaning, crack filling, chemical wash, application of one layer of cement chemical(SBR latex) with fiber mesh, followed by putty and an additional layer of cement chemical. Final coating of SBR latex chemical shall be applied on top. Waste generated shall be disposed of in the nearby designated area with prior permission of GTL. The SOR also includes a 24-hour pond test after job completion. 300 Sq. mtr 500 213482 150,000
126 Transportation of Scrap material (Hazardous Waste, batteries, Used Oil, Structural Steel, Plastic, GI Sheets, UPVC Sheets, Wooden Scrap etc. ) from various GTL terminals up to Scrap yard/Designated Terminal within Base as directed by engineer-in-charge. The job includes loading of material in vehicle, transportation abiding all safety precautions and unloading at designated places. The Vehicle shall be as per the weight & volume of scrap material which shall be pre-identified jointly by GTL & Contractor. No extra charges shall be paid for Manpower, Equipment's etc. for loading & unloading of the material.
127 Supply and installation of Warning Board / Warning Marker / Notice Board including stencilling the Warning Write ups, logo, arrow markers & signs; to be installed at identified locations as per the specimen drawing enclosed including supply of all materials for grouting in 1:3:6 PCC mixtures to correct line, level and direction. The work also includes transportation to site of installation, necessary excavation for grouting of post, cleaning under ground portion up to 300 mm height from the ground level. No separate charges shall be paid for manpower, consumables, lifting equipment's, handling, tools & tackles used during execution of this activity. 2 Nos. 27,013 212856 54,026
128 Requirement of Structural Civil Engineer at GTL Sites /station. This job is inclusive of site visit for issuing of structural stability certificate of existing GTL site(Viz GTL building , process area piping support etc) .During the site visit any abnormality/irregularity observed then recommendation report for the mitigation requirement with drawing ,BOM etc. to be submitted to GTL. 5 Per station 4,739 212877 23,695
129 Installation of safety signage’s board (4 mm ACP sheet with High quality radium eco solvent sticker with gloss lamination) 20 Sq ft. 2,369 212884 47,380
130 Providing and installation of radium eco solvent sticker with gloss lamination for safety boards, station Piping,Pole,JB etc 250 Sq ft. 2,369 212885 592,250
131 Supply of molykote 1000 grease 5 Per Kg 8,056 212888 40,280
132 Excavation, Laying, Testing, Nitrogen purging, Commissioning & Backfilling of MDPE 90/160 mm OD X SDR 17.6 1 R. Mtr. 294 213483 294
133 Supply of technician with plastic jointing machine for MDPE 90/160 mm OD X SDR 17.6 with tools & tackles. 1 Mandays 2,453 213484 2,453
134 Complete job of repairing the PE (90mm and 160mm PE pipe dia.) damage / leakage of existing under ground pipeline. Complete job of repairing the leakage/damage of existing buried PE pipeline. The job includes mobilization of team along with tools and tackles, cordoning safeguard the site as per EIC instruction, traffic diversion if any, co-ordination with external agencies/authorities if any, public announcement in gas supply affected area for customer information, excavation of pit to locate the leakage/damage, dewatering, cleaning of pit, squeezing, electrofusion jointing, resume gas supply, soap solution test, backfilling and public announcement after gas resumption to affected customers. The scope covers required tools and tackles, isolation of network or squeezing including the equipment's, manpower that are required for rectification of leakage/repair shall be in scope of contractor. 2 Each 1,472 213485 2,944
135 Dismantling of existing Valve Chamber of any size - including PE pipeline connectivity - demolition of Civil foundation, site restoration with cleaning of debris, transportation of PE valve assembly to GTL Store 1 Each 6,868 213486 6,868
136 Supply and Installation of HDPE water pipelines including fittings as mentioned below sizes in control room building / terminal at damaged locations. No separate charges for plumber shall be paid.
136.1 2" HDPE Pipe Size & Fittings 10 R. Mtr. 500 213487 5,000
136.2 4" HDPE Pipe Size & Fittings 10 R. Mtr. 600 213488 6,000
137 Supply and installation HDPE fittings in water pipeline at damaged location. No separate charges for plumber shall be paid.
138 Earth work in excavation, site grading in all kinds of soil including soft rock in any plan dimension including disposal of excavated surplus and unserviceable earth up to any lead in all conditions. Soil to be levelled and neatly dressed complete in all respect as per scope of work, as per detailed construction drawings, as per technical specifications and directions of the Engineer-in-charge. 300 Cu mtr. 348 213497 104,400
139 Demolishing brick work including staking of serviceable materials and disposal of unserviceable material within 1KM lead including transportation/labour etc. 1 Cu mtr. 1,505 102023 1,505
140 Demolishing of RCC work by using mechanical breaker / Hammer / Manually / abrasive cutting machine including stacking of steel bars and disposal of unserviceable material within 1 KM lead with all tools/tackles/equipment/machinery/labour etc. 5 Cu mtr. 2,842 101897 14,210
141 Breaking of PCC from damaged floor by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the demolished materials within a lead of 1 KM. 5 Cu mtr. 1,666 100124 8,330
142 Back-filling of available excavated earth (excluding rock) in trench, sides of foundation etc in layers not exceeding 30 cm in depth consolidating earth deposited layer by ramming and watering, lead up to 100 Mtr. and filling up to required Ground level. No separate charges shall be paid for manpower, consumables, equipment, handling, tools & tackles used during execution of this activity. 300 Cu mtr. 223 211771 66,900
143 Supplying and filling Sand in 150 mm thick layers watering, rolling, ramming, consolidating and dressing the surface including cost of sand (Zone-II/Zone-III sand only) complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge. 1 Cu mtr. 1,620 213498 1,620
144 BRICK WORK IN SUB STRUCTURE
144.1 Providing and construction and handing over brick masonry work with brick class designation M-7.5 of IS:1077 in Cement Mortar 1:4 (1cement : 4 coarse sand) below DPC including weep holes, plastering of 15 mm thickness in CM 1:4 on exposed surfaces, mud mat, excavation and backfilling with serviceable earth, complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. 5 Cu mtr. 6,372 213499 31,860
145 BRICK WORK IN SUPER STRUCTURE
145.1 Providing and construction and handing over brick masonry work with brick class designation M-7.5 of IS:1077 in Cement Mortar 1:4 (1cement : 4 coarse sand) in superstructure plastering of 15 mm thickness in CM 1:4 on both the faces complete in all respects as per scope of work, detailed construction drawings , technical specifications and direction of Engineer-in-charge. 10 Cu mtr. 7,683 213500 76,830
146 PLAIN CEMENT CONCRETE
146.1 Providing, laying in position, construction and handing over of PCC in all types of concrete works including levelling courses below foundations, mass concrete works, chambers, cable trench, under floors and any other locations (which are not covered as part of respective items of SOR), at all levels and locations etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. 10 Cu mtr. 5,508 213501 55,085
147 Providing and laying RCC (reinforced cement concrete) of grade M-20 with 20mm and down grade crushed stone aggregate in all types of sub-structures like foundations, beam, columns, pedestals, pedestal bases, cable trench, RCC retaining wall foundation for boundary wall including construction joints, bitumen painting on surfaces in contact with soil, shuttering, supplying and fixing MS inserts/bolts,conduits,precast covers, finishes etc. at all depths and levels complete as per drawings, specifications and directions of the Engineer-in-charge. 10 Cu mtr. 7,593 213502 75,930
148 Providing and laying RCC (reinforced cement concrete) of grade M-25 with 20mm and down grade crushed stone aggregate in all types of sub-structures like foundations, beam, columns, pedestals, pedestal bases, cable trench, RCC retaining wall foundation for boundary wall including construction joints, bitumen painting on surfaces in contact with soil, shuttering, supplying and fixing MS inserts/bolts,conduits,precast covers, finishes etc. at all depths and levels complete as per drawings, specifications and directions of the Engineer-in-charge. 15 Cu mtr. 7,872 213503 118,080
149 Providing and laying RCC (reinforced cement concrete) of grade M-20 with 20 mm and down grade crushed stone aggregate in all types of super-structures like slab, columns, beams (except building superstructure which are not covered elsewhere), pedestals, pipe supports, RCC retaining wall, boundary wall including construction joints, shuttering, supplying & fixing MS inserts/bolts,conduits,precast covers, finishes etc. at all heights and levels complete as per drawings , specifications and directions of the Engineer-in-charge. 1 Cu mtr. 7,593 213504 7,593
150 Providing and laying RCC (reinforced cement concrete) of grade M-25 with 20 mm and down grade crushed stone aggregate in all types of super-structures like slab, columns, beams (except building superstructure which are not covered elsewhere), pedestals, pipe supports, RCC retaining wall, boundary wall including construction joints, shuttering, supplying & fixing MS inserts/bolts,conduits,precast covers, finishes etc. at all heights and levels complete as per drawings , specifications and directions of the Engineer-in-charge. 1 Cu mtr. 7,872 213505 7,872
151 Supplying and Fabricating and Fixing in position HYSD Steel Reinforcements/ TMT Grade Fe-500/550 conforming to IS1786-1985 at all levels and positions including the Cost of transport, Straightening, Cutting, Bending, Cranking, Binding, Welding, Provision of necessary Chairs and Spacers, Preparation of bar bending schedule and getting the same approved by EIC etc., complete as per Drawings and Specifications and including Cost of binding wire, Labour etc., all complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. The chairs and spacer bars provided will not be Measured for payment. 1000 Kg 96 205438 96,000
152 Cleaning of underground/overhead water tank pit deploying all necessary equipment, manpower etc. including de-watering, sludge removal, disinfection using chlorine or potassium permanganate, cleaning with fresh water and disposal of sludge and debris within a lead of 1 Km. (by involving professional agency) 2 Nos. 172 212070 344
153 Cleaning of Soak Pit/ Septic Tank/ SEVER/Mud Pit with its associated system including removal of sock/mud, dewatering, removal of chocking if any, debris and disposal of the same to the distance of 10 Km, cleaning with fresh water including tools/tackles/transportation/material/labour etc., 5 Nos. 1,437 212071 7,185
154 FLOORING WORKS
154.1 Providing and laying vitrified floor tiles in different sizes 5 Sq. mtr 1,066 213506 5,330
154.2 Providing and fixing 1st quality ceramic glazed floor tiles 10 Sq. mtr 1,067 212097 10,670
154.3 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite 1 Sq. mtr 7,670 213507 7,670
154.4 Providing and fixing 10 mm thick acid and/or alkali resistant tiles 1 Sq. mtr 1,719 212095 1,719
155 Supplying and laying of Cement Concrete inter locking paver block 80 mm thick, I shape or as per GTL or any other approved shape, rough finish, M-40 compressive strength of approved brand laid over the sand bed of minimum 100 mm thick. The CC interlocking blocks to be of uniform Grey colour or as approved by EIC complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. 25 Sq. mtr 1,095 212087 27,375
156 Providing and laying 12 mm thick cement plaster on walls, RCC beams, columns and chajja etc of mix 1:4 ( I cement, 4 fine sand) including making of typical grooves drip-course including hacking of RCC roof beams and columns surfaces and curing etc. The job includes the cost of supplying and fixing of chicken wire mesh at every joint of brick masonry and RCC before commencing the plastering work complete in all respect as per scope of work, detailed construction drawings , technical specifications and directions of the Engineer-in-charge. 25 Sq. mtr 290 205434 7,250
157 Supplying and applying 2 coats of reputed paint / Weather coat / Weather shield on external walls surfaces in approved colour at all heights as per scope of work and recommendations of manufacturer including surface preparation, primer putty etc. detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. 800 Sq. mtr 264 213508 211,200
158 Enamel painting of interior wall of building, providing & applying acrylic emulsion paint of required shade and quality including the preparation of surface for painting, applying primer and 2 coats of acrylic emulsion paint as directed by EIC including temporary covering of panels / equipment installed in room with Polythene sheet. 500 Sq. mtr 233 212068 116,500
159 Snow-cem painting of exterior wall finishing walls with water proof cement paint, at all heights, with 2 or more coats of approved shade and approved brand and quality such as “super snow-cem” or equivalent approved brand on Rough wall surfaces, which includes rough plaster, sand face and brick face surfaces to give an even shade including scaffolding and preparation. 50 Sq. mtr 119 102220 5,950
160 Painting of Above Ground Civil Supports/Foundations/Earth Pits etc. (Existing/Newly Constructed) including Paint (Terra cotta), equipment for application & its accessories, manpower, material etc up to required surface finish. 100 Sq. mtr 194 211572 19,400
161 Repairing asphalt metal road which includes pot hole filling, levelling, patching, carpeting, etc. 100 Sq. Mtr. 286 212192 28,600
162 Providing and fixing FRP Plain Sheet of 2.00 mm thickness in Plain profile of approved colour on roofing and sides as per manufacturer's instructions including cost of sealant in the overlapping portion of sheets complete and all accessories. 20 Sq. mtr 1,092 212179 21,840
163 RoU Protection works in case of Exposure/ Soil Erosion, The rates includes royalty or any other levies by Govt. agencies towards taking of loose earth from borrowed area for required back-filling and required compection as per the direction of engineer-in-charge/site engineer inclusive all labour, materials, tools, tackles, transportation, taxes etc. completion all respect. (Payment shall be made on basis of measurement of the pit profile of the earth washout in the ROW)
163.1 Random rubble masonry 200 Cu mtr. 3,000 213509 600,000
163.2 Supply & Filling Empty Cement Bags 50 Kg Capacity with sand cement mixture (10:1) 500 Nos. 140 3000640 70,000
164 Providing and fixing G.I. chain link fencing 1 Sq. mtr 1,043 102026 1,043
165 Providing and fixing in concrete at all levels and positions, bolts with nuts and washers, pipe sleeves etc. including painting the exposed surfaces with two coats of approved paint, providing grease to exposed area of bolts, welding wherever necessary, complete as per drawing, specifications and instruction of engineer in charge (PCC blocks, jigs and fixtures will not be paid extra) and protecting the same till final erection. 10 kg 300 213402 3,000
166 AL. WINDOWS & PARTITIONS
166.1 Supply and Application of Good quality Sun Film of ISI mark, black colour on plain float glass. 5 Sq. mtr 63 212107 315
166.2 Providing and fixing of window & door hinges with necessary fittings materials 1 Nos. 402 213510 402
166.3 Providing & fixing of sliding window lock with necessary fittings materials 1 Nos. 402 213511 402
166.4 Supply & installation of PVC sheet in existing aluminium door with necessary fittings materials 1 Sq ft. 402 213512 402
167 BUILDING REPAIR & MAINTENANCE
167.1 Supply&Fix Alum Door Section thk 2.5mm 70 Sq. mtr 5,865 212103 410,550
167.2 Supply&Fix Alum Window Section Thk2.5mm 50 Sq. mtr 5,865 212104 293,250
167.3 Provid&Fix Float Glass Window etc 6mm Thk 70 Sq. mtr 2,645 213513 185,150
167.4 Provid&Fix Overhead Hydraulic Door Closer 5 Nos. 1,268 212109 6,340
167.5 Providing & Fixing Floor spring for door operation 10 Nos. 6,000 213403 60,000
167.6 Suply,Ins,Test&Commi Glazed European Urinal 5 Nos. 5,729 212152 28,645
168 Removal of damaged false ceiling from the position and disposal of the same within a lead of 500 meters and fixing new false ceiling in place/ in position of old ceiling including repair & restoration of required Metal frame work. 15 Sq. mtr 212 212176 3,180
169 Supply of utility water suitable for sanitation purpose, plantation and gardening at designated locations of stations in tanker The job including filling of water in tanker, transportation, handling and transferring to U/G water tanks of GTL
170 Supply of RO drinking water in 20 L capacity bottle at various station of GTL 1200 per bottle 30 213514 36,000
171 Hiring of JCB for doing any normal/emergency excavation. The period of hiring will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will not be paid. Maximum working time per day will be 8 Hrs. Rate for idle time of JCB shall be 50%. (Note: No separate payment shall be made for the quantity of excavation done.)Hiring rates is inclusive of diesel, operators, maintenance and transportation cost etc. 150 Per Hrs. 2,000 213515 300,000
172 Hiring of Backhoe for doing any normal/emergency excavation. The period of hiring will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will not be paid. Maximum working time per day will be 8 Hrs. Rate for idle time of Backhoe shall be 50%. (Note: No separate payment shall be made for the quantity of excavation done.) Hiring rates is inclusive of diesel, operators, maintenance and transportation cost etc. 1 Per day 36,800 213516 36,800
173 Painting of boundary wall , providing & applying paint of required shade and quality including the preparation of surface for painting, applying primer and 2 coats of weather proof/weather coat paint as directed by EIC. 500 Sq. mtr 119 213517 59,500
174 Filling empty Geo textiles bags(Bag will be supplied by GTL) of 150 kg capacity (the bags to be used in good condition only) by using sand and stitching by using jute threads and placing in position in RoW as directed by engineer-in-charge /Site Engineer. No separate charges shall be paid for manpower, machinery, consumables, transportation to site location, tools & tackles used during execution of this activity. 300 Nos. 100 213519 30,000
175 Painting of numbers/ letters/ logos/ arrow etc including supply of fluorescent/ highlighted paint/ acrylic emulsion/ oil paint of approved brand as per the approved vendor list and quality wherever required as per directed by GTL EIC 110 Sq ft. 770 210927 84,700
176 Providing and laying anti-skid vinyl flooring sheet 2.5 mm thick over base floor. 25 Sq. mtr 517 212211 12,925
177 Supply, transportation & installation of reputed UPVC/PVC water tank with cover of different sizes with replacement of old one at required location including all necessary fittings, & accessories.
177.1 500 ltr Water Capacity 1 Nos. 7,280 212187 7,280
177.2 1000 ltr Water Capacity 1 Nos. 14,000 212188 14,000
178 Supply and replacement of 1/2" to 01" UPVC elbow/coupler/tee for water pipeline works 10 Nos. 413 213520 4,130
179 Providing and fixing Gypsum board false ceiling of 12.5 thick ,Gypsum board of tile size (610 x 610) mm weight of tile shall be 8.00 (kg/m2) suspended from RCC ceiling fixed with the help of (125 x 38) mm rowl plug and hanged with 5 mm thick galvanised hangers. Tiles shall rest over aluminium frame of (25 x 38) mm main and t @ 610 mm c/c including providing and fixing aluminium angle of size (25 x 25) mm all around the wall including all labours, material, scaffolding, screws, nails, hire charges of drill machine or any other material required for satisfactory completing of work and as per direction of EIC. 1 Sq. mtr 2,450 213521 2,450
180 Survey for Sub surface gas detection along the pipeline RoU. 1 kms 400 213522 400
181 Dismantling and taking out of submersible pump-motor of rating 3KW / 5 KW from bore well, retaining and rolling of power cable pulled out from bore well. And reinstallation of repaired motor and associated assembly back into the bore in complete working condition. The rate for repairing of damages in the system shall be paid as per list below. All the tools tackles, manpower, tripod, fasteners etc. required for the job is included in the scope.
181.1 Rewinding including bearing bushing etc. 3/5 KW 2 Nos. 5,897 208958 11,794
181.2 Rectification/Replacement of mechanical damage of pump including bearing bushing etc. 2 Nos. 8,040 208960 16,080
182 Supply and installation of Submersible Pump (3HP) with motor assembly 2 Nos. 30,309 213155 60,618
183 Supply & replacement of starting capacitor for 1-phase submersible pump set ( 250 mfd) 4 Nos. 933 208976 3,732
184 Supply & Installation of Bore-well Starter Single-Phase up to 5kw. Starter should be with in-built over load tripping feature. 6 Nos. 4,642 208977 27,852
185 Supply & Installation of Bore-well Starter Three-Phase up to 5 Kw. Starter should be with in-built over load tripping feature. 1 Nos. 6,369 208978 6,369
186 Supply, Transportation and Installation of lighting Pole (excluding of luminairs, fixtures, JBs etc.) of reputed make confirming IS 2062/IS 1161 material of GI pipe of height approximately 5 to 12 Meter including utilising & fixing of existing luminaire, JBs, Earthing connection, cable connection etc. on new pole.
187 Supply & installation of unamroured/flexible multistrand Copper earthing cable 16 sq mm. The job includes the excavation, removal of existing Copper Strip, laying of new cable, back-filling & restoration. No separate charges shall be paid for manpower, tools & tackles, equipment's, instruments used during this activity. 450 R. Mtr. 483 210780 217,350
188 Collection of hazardous wastes including used engine oil, gear oil, hydraulic oil, turbine oil, compressor oil, transformer oil ,spent oil, filter elements, grease contaminated cotton waste etc. from GTL stations and disposal-off the same to an approved CPCB / GPCB vendor by complying Hazardous Waste (Management and Handling) Rules, 1989. 200 Kg 154 208680 30,800
189 Supply, installation testing & commissioning of Copper earthing: the job includes: a) Excavation of a pit of size (900 mm x 900mm x 3500mm deep) b) placement of Copper earth plate (600mm x600mmx6mm) and embedding the GI pipe of 20mm, 3Mtr. length in the earth c) back filling the pit with alternate layers of approx. 100Kg Charcoal and 50 Kg salt to cover the earth plate The pit shall further be refilled with earth up to ground level and compacted. Copper Strip (Size 25mm X 3mm) 2 nos. shall be provided from plate electrode to ground level to facilitate jointing with earth wire. It shall be provided with test link for testing of the particular earth pit. The funnel shall be installed above the ground for facilitating pouring of water. The funnel of earthing pits shall be covered by brick masonry chamber (Size 900mm x 900 mm x 600mm) with cement plaster on inside and outside. The chamber shall be provided with a hinged MS cover and frame fixed on chamber alognwith tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1 ohm 1 Nos. 23,117 213110 23,117
190 Supply, Installation, Testing & Commissioning of GI Pipe Earthing. A Pit (Size : 3500 mm deep) shall be excavated by auguring or otherwise, 65 dia GI pipe 3.5 Mtr. length shall be put. The GI pipe shall be cut tapered at the bottom and provided with holes of 12 mm dia. drilled at 75 mm interval up to 2.5 Mtr. length from bottom.The pit shall be back filled with alternate layers of appx 100 kg of charcoal and 50 kg of salt. The Pit shall further be refilled with earth up to ground level and compacted. GI Strip size 50x12mm shall be welded to this GI Pipe at ground level to facilitate jointing with earth wire. It shall be provided with test link for testing of the particular earth pit. The funnel shall be installed above the ground for facilitating pouring of water. The funnel of earthing pits shall be covered by brick masonary chamber (Size 900mm x 900mm x 600mm) with cement plaster on inside and outside. The chamber shall be provided with a hinged MS cover and frame fixed on chamber along with tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1 ohm. 1 Nos. 15,925 213111 15,925
191 Supply, installation testing & commissioning of Copper earthing, Chemical Maintenance Free Earth Pit 10 Nos. 29,293 213112 292,930
192 Supply, installation testing & commissioning of GI earthing, Chemical Maintenance Free Earth Pit 20 Nos. 21,069 213113 421,380
193 Supply, Laying & Installation of Copper earthing strip – 25 x 3 mm (Above ground / Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includes cutting the strip suitable to site, edge preparation , excavation of required length, strip laying and back filling after completion , site welding and bending and termination as per EIC, supply of connection bolts etc. 100 Mtr.. 575 500747 57,500
194 Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Above Ground) with over lapping of minimum 75 mm at joints and two consecutive strips to be welded together and applying bitumen on the joint. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 1 Mtr.. 173 500748 173
195 Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strips to be welded together and applying bitumen on the joint. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 100 Mtr.. 210 500749 21,000
196 Replacement of concrete/ MS plate covers of Earth Pits by hinged acrylic covers with locking/bolting facility & with facility to change testing date. The related modifications of massonary works of Earth pits shall be in the scope of the contractor. 30 Nos. 2,569 210787 77,070
197 Supply and Installation of LED tube light having 20W Al body T8 Tube Rod with colour temp. 6500K of reputed makes 100 Nos. 1,228 211619 122,800
198 Supply and Replacement of LED Tubes/ Lamps of reputed make including scaffolding, men, machinery if required as per EIC. Job includes installation on pole (up to 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables, lifting equipment's, handling, tools & tackles used during execution of this activity.
198.2 18 w Four/Two Pin LED 70 Nos. 309 211620 21,630
198.5 120 W flood light LED 50 Nos. 9,158 211627 457,919
198.6 72 W street light LED 50 Nos. 3,181 211630 159,067
198.7 45 W flameproof street light LED 25 Nos. 16528 212722 413,200
198.8 30 W, 12V light LED for Solar light 5 Nos. 13848 213596 69,240
199 Supply and installation of 2 X18 W batten lighting fixture of reputed make including LEDs length 04 ft. 40 Nos. 2,812 211635 112,480
200 Supply and Installation of flameproof LED Flood light fixtures 120 W of reputed Make with PESO approved 15 Nos. 10,923 211640 163,845
201 Supply and Installation of LED Type Indication Lamp in Panel.
202 Supply and installation of reputed make switch fuse unit
203 Supply and replacement of Capacitors(1-10 mfd) of reputed make 10 Nos. 136 209053 1,360
204 Supply and Replacement of Heavy duty 4 Pole Terminal block in outdoor lighting JB and in other electrical Panels
205 Supply & Replacement of MCB, 10 KA of reputed Make
206 Supply & Replacement of MCB/MCCB, 50 KA of reputed make
206.8 MCCB Box up to 250A MCCB 1 Nos. 27,013 212605 27,013
207 Supply & Replacement of ELCB/RCCB of reputed make
208 Supply and Replacement of HRC Fuse of reputed make
209 Supply and Replacement of Bakelite Fuse Fittings of reputed make for below given size
210 Supply and Installation of utility spares of reputed make
210.1 3 Pin Plug Top up to 16A 50 Nos. 141 208729 7,050
210.2 3 Pin Socket (With/Without Safety Shutter) up to 16A 100 Nos. 108 208730 10,800
210.3 Piano switch up to 16 A (single pole) (Industrial/Modular) 100 Nos. 86 208731 8,600
210.4 Piano switch up to 32 A (double pole) (Industrial/Modular) 20 Nos. 370 208732 7,400
210.5 3 Pin Switch Socket board up to 16 A with indicator (PVC/ Acrylic/Metal) 50 Nos. 380 208733 19,000
210.6 3 Pin 6/16 A surface type combined switch socket outlet (Industrial/Modular) 50 Nos. 174 208734 8,700
210.7 3 Pin 6/16 A flush type socket outlet 60 Nos. 174 208735 10,440
210.8 Switch type fan regulator Electronic 60 Nos. 174 208736 10,440
210.9 Socket type fan regulator Electronic 55 Nos. 261 208737 14,355
210.10 25 mm dia PVC conduit 65 Mtr.. 119 208738 7,735
210.11 PVC Casing / Capping of size up to 50 x 16 mm 1 Mtr.. 163 209082 163
210.12 PVC Flexible Corrugated Conduit up to size 50 mm 1 Mtr.. 196 209083 196
211 Supply and Installation FLUSH Type On-Off Push Button switch 19mm Dia 1 Nos. 240 500615 240
212 Supply and Installation NO Block for On-Off Push Button Flush Type 1 Nos. 240 500616 240
213 Supply and Installation Side Hinged SMC FRP Based Pole mounted Junction Box including cable gland of appropriate size for Street Light/Flood Lighting pole for below mentioned size of reputed make
214 Supply and Installation of Terminal Connectors in Electrical Panels & Junction bos suitable to Din Rail type mounting for below mentioned size of reputed make with Side lock plates/separators Operating voltage is 240/440 Volts.
214.2 Above 16 SQmm up to-32 Sqmm 12 Nos. 430 500627 5,160
214.3 Above 32 SQm m up to-63 Sqmm 15 Nos. 567 500628 8,505
215 Supply and placing of insulation Rubber Mats (2.5 mm thick, class-B, Colour-Blue) as per IS15652;2006(New IS Standard) & of reputed make. Material batch test certificate shall be provided along with material. 6 Sq. mtr 1,221 211794 7,326
216 Supply and Installation of SS 316, double compression type Cable Glands for armoured twin and multicore power cables of voltage grade 650/1100 V and Instrument cables along with PVC Shrouds. The Glands Shall be Flameproof to Gas Group IIA, IIB and Weatherproof to IP 65, for cables having overall diameters as given below.
217 Cable Fault Repairing - Supply and installation of reputed make Cable Jointing Kits for following Cables including IR test and Re-commissioning of cable. The work includes excavation up to the cable, making required trenches for execution of job and backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables, equipment's, tools & tackles used during execution of this activity.
217.1 Upto 3 C x 50 sq. mm. Cu. Armoured Cable 1 Nos. 3,239 208689 3,239
217.2 Upto 4 C x 50 sq. mm. Cu. Armoured Cable 1 Nos. 3,239 208690 3,239
217.3 Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Nos. 3,098 208691 3,098
217.4 Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Nos. 3,098 209099 3,098
218 Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes. Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The Insulation Resistance of cable has to be checked & report to be submitted before commissioning. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity.
218.1 Upto 3 C x 6 sq. mm. Cu. Armoured Cable 200 Mtr.. 367 500629 73,400
218.2 Upto 4 C x 6 sq. mm. Cu. Armoured Cable 100 Mtr.. 444 500630 44,400
218.3 3 C x 10 sq. mm. Cu. Armoured Cable 10 Mtr.. 524 500631 5,240
218.4 4 C x 10 sq. mm. Cu. Armoured Cable 10 Mtr.. 619 500632 6,190
218.5 3 C x 16 sq. mm. Cu. Armoured Cable 10 Mtr.. 700 500633 7,000
218.6 4 C x 16 sq. mm. Cu. Armoured Cable 10 Mtr.. 860 500634 8,600
218.7 3 C x 25 sq. mm. Cu. Armoured Cable 10 Mtr.. 1,027 500635 10,270
218.8 4 C x 25 sq. mm. Cu. Armoured Cable 10 Mtr.. 1,261 500636 12,610
219 Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc,. Only Cable will be supplied by GTL at designated stores. The Insulation Resistance of cable has to be checked & report to be submitted before commissioning. No separate charges shall be paid for transportation of cables from GTL designated stores to the site, manpower, consumables, equipment's, tools & tackles used during execution of this activity. Upto 4 C x 25 sq. mm. Cu. Armoured Cable 10 Mtr.. 300 213404 3,000
220 Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed instrumentation Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity.
220.1 FRLS Flexible Earthing cable of 6 sq. mm. 250 Mtr.. 218 212607 54,500
220.2 Flexible cable up to 3 C x 6 sq. mm. cable 100 Mtr.. 448 3000548 44,800
221 Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The Insulation Resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity
221.1 Upto 3 C x 6 sq. mm. Cu. Armoured Cable 100 Mtr.. 562 209110 56,200
221.2 Upto 4 C x 6 sq. mm. Cu. Armoured Cable 100 Mtr.. 641 210884 64,100
221.3 3 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr.. 699 209111 699
221.4 4 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr.. 794 210885 794
221.5 3 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr.. 874 210886 874
221.6 4 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr.. 1,034 210887 1,034
221.7 3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr.. 1,179 208697 1,179
221.8 4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr.. 1,413 208698 1,413
221.9 1 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr.. 707 210888 707
222 Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GTL at designated store. The Insulation Resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for transportation of cable from GTL designated store to site, excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity.
222.1 Upto 3 C x 2.5 sq. mm. Cu. Armoured Cable 1 Mtr.. 381 210889 381
222.2 Upto 3 C x 6.0 sq. mm. Cu. Armoured Cable 1 Mtr.. 381 210890 381
222.3 Upto 3 C x 10.0 sq. mm. Cu. Armoured Cable 1 Mtr.. 381 210891 381
222.4 Upto 3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr.. 406 210892 406
222.5 Upto 4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr.. 406 210893 406
223 Supply & Installation of single phase Heavy Duty Exhaust Fan, .No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Fan should be having thermal cut off protection.
224 Supply & Installation of single phase Heavy Duty flameproof PESO approved Exhaust Fan, .No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Fan should be having thermal cut off protection.
225 Supply and Installation of BLDC ceiling fan (reputed make), white / ivory colour, 230v, 1-Phase, 1200 mm sweep. It shall have robust two piece motor construction, All Aluminium alloy construction with double ball bearing and powder coated finish to protect metal from corrosion. The fan shall be energy efficient having 5 star rating. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 15 Nos. 2,398 209128 35,970
226 Supply and Installation of Wall mounted cabin fan , 230V, 1-Phase, 300 mm sweep of reputed make 6 Nos. 2,725 211644 16,350
227 Supply and Installation of self priming Monoblock pumps of reputed make operating on single phase, up to rating of 2 HP, with matching piping connections. Work includes dismantling of already installed pump, required inlet/outlet connection, foot valves servicing & cable termination. No separate charges shall be paid for manpower, consumables,equipments, tools & tackles used during execution of this activity. 4 Nos. 14714 209129 58,856
228 Rewinding of the following motors/Monoblock Pump. work includes removal of the equipment, rewinding & repairing, re-installation of the same.(Including replacement of Bearing).No separate charges shall be paid for manpower, consumables,equipments, bearings, tools & tackles used during execution of this activity.
228.1 Ceiling or wall mounted fan 10 Nos. 872 208726 8,720
228.2 Monoblock pump up to 2.0 HP 5 Nos. 2,452 3000554 12,260
228.3 Exhaust Fan heavy duty 15 Nos. 1,634 208727 24,510
228.4 Exhaust Fan heavy duty explosion proof IIA & IIB 3 Nos. 2,398 210928 7,194
229 Painting of lighting pole/ Solar pole / Stack including surface preparation, supply of paint and application of 2 coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy paint of Silver colour of reputed make give an even shade after proper removal of existing paint and clearing of surface free from foreign materials. No separate charges shall be paid for manpower, consumables, equipment's, letter writing of tag Number, tools & tackles used during execution of this activity.
229.1 Upto 4.5 Meter Height Pole (FLP Light pole in process area) 25 Nos. 1,595 209165 39,875
229.2 Upto 6 Meter Height Pole (Solar Light) 10 Nos. 1,853 209164 18,530
229.3 6.1 Meter to 9 Meter Height Pole 20 Nos. 2,315 209163 46,300
229.4 9.1 Meter to 11 Meter Height Pole 20 Nos. 2,779 209162 55,580
230 Chemical foam washing of evaporator and condenser coil of Air conditioner 60 Nos. 1,000 213523 60,000
231 Supply and installation of capacitor for A.C compressor of 1.5 TR, 2 TR
232 Supply and installation of capacitor for fan motor of 1.5 TR, 2 TR
233 Supply and installation of thermostat switch of compressor for 1.5 TR, 2 TR 10 Nos. 864 210032 8,640
234 Supply and replacing of faulty relay in compressor for 1.5 TR, 2 TR 10 Nos. 756 210033 7,560
235 Supply and replacement of 3 way switch for 1.5 TR, 2 TR 10 Nos. 702 210034 7,020
236 Supply and replacing of outer cover for AC units for 1.5 TR, 2 TR
237 Supply and replacing of front grill of Split A.Cof 1.5 TR, 2 TR
238 Supply and installation of copper tubing for1.5 TR, 2 TR 60 Mtr.. 1,199 213210 71,940
239 Supply and replacing of contactor coil for 1.5 TR, 2 TR
240 Repairing of control circuit of indoor AC unit up to 02 Ton 17 Nos. 3,450 210760 58,650
241 Supply and installation of control circuit unit from OEM of indoor AC unit up to 02 Ton 17 Nos. 5,838 213116 99,246
242 Supply and installation of required Cu armoured cable for AC of 1.5 TR, 2TR 11 Mtr.. 424 212699 4,664
243 Supply and replacing of Drain pipe of PVC for 1.5 TR, 2 TR 50 Mtr.. 159 212960 7,950
244 Supply and replacing of Swing motor 12 V for 1.5 TR, 2 TR 5 Nos. 150 750
245 Supply and replacing of exhaust fan of outdoor unit for 1.5 TR, 2 TR
246 Supply and replacing of flapper for indoor unit for 1.5 TR, 2 TR
247 Supply and replacing of Air filter net for 1.5 TR, 2 TR
248 Supply and replacing of insulation of AC duct from outdoor to indoor for 1.5 TR, 2 TR 6 Mtr.. 380 213211 2,280
249 Repairing, rewinding & re-installation of blower fan motor for 1.5 TR, 2 TR AC.This job includes removal of faulty motor, repairing & rewinding and re-installation. No separate charges shall be paid for manpower, consumables, bearings, equipment's, tools & tackles used during execution of this activity. 15 Nos. 1,307 210048 19,605
250 Supply and replacing of insulation of indoor blower fan motor for 1.5 TR, 2 TR 20 Nos. 2,715 212610 54,300
251 Supply and replacing of AC outdoor unit valve brass cap for 1.5 TR, 2 TR 20 Nos. 558 212612 11,160
252 Charging of refrigerant for 1.5 TR, 2 TR 60 Nos. 2,180 210049 130,800
253 Shifting of A.C including gas charging, up to three meter copper tubing and civil work for 1.5 TR, 2 TR. The job includes dismantling, handling, transportation, re-installation, testing & commissioning of A.C.Units. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Above three meter copper tubing will be paid extra as per relevant SOR. 10 Nos. 3,814 210055 38,140
254 Supply and installation of the outdoor unit condenser body of AC 1.5 to 2 TR. The job includes dismantling of old one,re-installation of new one , testing & commissioning. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 8 Nos. 4,904 210056 39,232
255 Supply of compressor and installation including gas charging for 1.5 & 2 TR Split AC(including inverter AC) . No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 8 Nos. 13,624 209195 108,992
256 Repairing & Reinstallation of AC Timer Panel, including replacement of Timer PCB & Relays. 1 Nos. 1,906 210919 1,906
257 Supply & installation of AC Timer Panel of Microprocessor based for Max 6 no of A.C Timer Operation. 1 Nos. 3,814 209199 3,814
258 Supply & Installation of Faulty PCB of Indoor AC unit for 1.5 TR to 2.0 TR 10 Nos. 3,814 209200 38,140
259 Supply & Installation of Air Conditioner out door unit Bracket/Stand. The Job includes of installation of required bracket in wall with drill & suitable fasteners. 15 Nos. 1,634 210920 24,510
260 Supply and installation of Banjo hose for DG set up to 125 KVA 6 Nos. 514 211656 3,084
261 Supply and Installation of KWH meters in DG set 1 Nos. 1,849 211655 1,849
262 Supply and installation of Thermostat for DG set up to 125 KVA 1 Nos. 1,849 211654 1,849
263 Supply and installation of Water temperature switch for DG set up to 125 KVA 1 Nos. 924 211653 924
264 Supply and installation of Spin on Lube oil Filter for DG set up to 125 KVA 1 Nos. 872 211652 872
265 Supply and installation of Spin on Diesel Filter for DG set up to 125 KVA 1 Nos. 1,489 211651 1,489
266 Supply and installation of Battery Charger 12 V for DG set up to 125 KVA 1 Nos. 4,623 211650 4,623
267 Supply and installation of Magnetic Pick-up coil for DG set up to 125 KVA 1 Nos. 4,623 211649 4,623
268 Supply of Coolant for coolant cooled engines 1 Litres 266 211633 266
269 Repairing of the leaked Radiator of Diesel Generator Set for the Capacity from 51 to 125 KVA includes dismantling and installation. 4 Nos. 3,852 500651 15,408
270 Supply & replacement of Automatic Voltage Regulator of Cummins make D.G set. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 3 Nos. 11,816 209206 35,448
271 Supply and Installation of Fuel Filter PRE Type 20 Nos. 667 209207 13,340
272 Supply of Fuel Filter MIC Type 20 Nos. 667 209208 13,340
273 Supply of Lube Oil Filter Element 20 Nos. 718 209209 14,360
274 Supply of Air Filter 1 Nos. 2,542 209210 2,542
275 Supply of Air Cleaner 1 Litres 2,542 211625 2,542
276 Supply & replacement of "V"-Belt for blower of Kirloskar/Cummins/ Crompton Greaves/ A49 make. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 4 Nos. 667 209212 2,668
277 Supply & replacement of Bearing set. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 2,569 209215 2,569
278 Supply & replacement of Oil seal for crank. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 2,773 209216 2,773
279 Supply & replacement of Steel Braided Diesel Pipe with/without banjo connection. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 2 Mtr.. 308 212961 616
280 Supply and replacement of engine oil for DG set / (20W40/15W40) 260 Litres 328 209218 85,280
281 Supply and Replacement of Cooling water pump for DG set up to 125 KVA 1 Nos. 8,000 213524 8,000
282 Supply & Installation of Automatic Float-Boost charger of 12V 6 Amp Rating. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 5,651 209221 5,651
283 Supply, removal of old battery & Installation of new 12V Lead-Acid Battery of Approved make for Invertor/ DG Set. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles, used during execution of this activity. Contractor shall quote considering the buyback of old battery.
284 Supply & Installation of 12V SMF Battery of Approved make. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Contractor shall buyback the old battery, hence price shall be quoted accordingly.
285 Servicing of DG starter system. The Work involves checking of ignition start switch & magnetic switch, fuse between ignition switch and 12 V battery, 12 V battery voltage and Sp. Gravity of battery water. Top-up of DM water in battery if required.
285.1 Supply and replacement of bearings. 1 Nos. 1,849 209233 1,849
285.2 Supply and replacement of magnetic rotors. 1 Nos. 4,623 209234 4,623
285.3 Rewinding of Alternator up to 50 kVA . 1 Nos. 35,447 209235 35,447
285.4 Rewinding of Alternator above 50 kv to 125 KVA 1 Nos. 42,125 210924 42,125
286 Supply and installation of Power contactors 4 pole up to 200A 1 Nos. 15,664 213525 15,664
287 Supply & Replacement of Faulty Power Contactor coil (65A-200 A;UI=1000V) 1 Nos. 18,494 209238 18,494
288 Supply & Replacement of Faulty Aux Contactor coil (For R,Y,B Phase Indication Contactor, 240 V Rating) 1 Nos. 1,130 209239 1,130
289 Supply & Replacement of Faulty Aux Contactor (For R,Y,B Phase Indication, 4A, 415/440 V Rating) 1 Nos. 1,849 209240 1,849
290 Supply and replacement of Current Transformer
290.1 CT Rasin Cast : CT ratio 50-100/1-5A, CL 5P20, VA 7.5 1 Nos. 945 209241 945
290.2 CT Rasin Cast : CT ratio 50- 100/1-5A, CL 1, VA 7.5 1 Nos. 1,007 209242 1,007
291 Supply and replacement of Analog/Digital Ammeters (0-100 Amp/AC) 1 Nos. 1,386 209252 1,386
292 Supply and replacement of Analog/Digital Voltmeters (0-450 V AC) 3 Nos. 1,386 209257 4,158
293 Supply and replacement of SF6 cylinder in case of SF6 breaker. 1 Nos. 1,541 209266 1,541
294 Dismantling, powder coating (Alkali Resistant Epoxy Powder Coated , Shade:RAL 7032) & reassembling of Ni-CD Battery Rack. Work includes Surface Cleaning of batteries with DM water & potential measurement of each cell voltage after reassembling. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 2 Nos. 6,678 209270 13,356
295 Supply of solenoid valve 5 Nos. 8,175 500669 40,875
296 Supply and replacement of display with Control card /circuit 2 Nos. 2,670 501459 5,340
297 Supply and replacement of ignition key assembly. 1 Nos. 3,269 500673 3,269
298 Supply and installation of door hinges and locks for DG set canopy 30 Nos. 1,634 500674 49,020
299 Supply and installation of caution board/danger notice on electrical panel as per IS 2551 having skull and bone sign with voltage level. 1 Nos. 925 500677 925
300 Supply & Installation of Terminal plate of 9 terminals with copper links for different type of TLP units 1 Nos. 4,682 213526 4,682
301 Supply and replacement Solar Module of solar light 2 Nos. 16,350 211684 32,700
302 Supply & Installation (Including removal of existing one) of Ni-CD Battery (VRPP) 1.2 V for UPS system
303 Supply and Installation of Pre cast Cable Route Marker (For Instrumentation and Electrical cables) 1 Nos. 770 211705 770
304 Dismantling and stacking of damaged lighting pole including excavation, cutting etc.& backfilling if required, completion of job in totality to the satisfaction of EIC within a lead of 100Mtr. The safe removal of existing luminaire, JBs, Earthing connection, cable connection etc. from the pole and handing over of same to GTL is in contractor's scope. No separate charges shall be paid for manpower, consumables, lifting equipment's, handling, tools & tackles used during execution of this activity. 10 Nos. 4,074 210976 40,740
305 Relocation of Lighting / Solar/OPD/PGD pole within the terminal which includes removal with or without RCC foundation & re-installation with proper foundation, concrete support etc. complete in all respect. This also includes levelling of old foundation location & backfilling if required, with all tools/tackles/labour/machinery/Hydra etc. Removal of fixtures, JB, earthing connections, Cable connections from pole at old location & reconnection and testing of all the system at new location is included in the scope. In case of relocation of pole to other terminal the transportation shall be given as per the relevant SOR. 4 Nos. 5,897 210066 23,588
306 TR Unit Fault finding, Breakdown maintenance irrespective of number of visits by Expert or representative of OEM of TR Unit and Repaired / replacement of spares if any required . The rates for Spares to be paid separately as per relevant SOR 1 Per TRU 12,282 211987 12,282
307 Supply and installation of Corrosion Coupons. 5 Nos. 8,549 211988 42,745
308 Current Attenuation Test survey at every 100 mtr. On pipeline network and submit complete detail report along with graph and recommendations. 25 kms 5,592 211989 139,800
309 Health Assessment of Transformer Rectifier unit as per requirement through OEM for verify the efficiency of TR unit including Anode Ground Bed condition assessment 1 Unit/Location 5,449 212055 5,449
310 Foreign Pipeline crossing survey for proper bonding and interference 1 Per location 1,421 212647 1,421
311 Interference Survey (AC / DC / Stay current) for Main line 1 per location 6,540 212062 6,540
312 CIPL Survey 100 Per kms 5,995 212064 599,500
313 DC interference survey for SV/IP /Terminal stations, critical area of interference, reasons & mitigation recommendations 1 Per location 8,283 212065 8,283
314 Direct Current Voltage Gradient (DCVG) based on CIPL / CAT survey report and recommendations and submit complete detail report along with fault location drawing and recommendations. 25 kms 7,051 211990 176,275
315 Painting of TLP/AJB/CJB unit including numbering and letter stencilling of TLP type by supply of reputed brand epoxy based Anti Corrosive Paint and Primer of zinc chromate base, including cleaning by wire brushing, scrapping the rusted area and application of Primer (2 coat) & Finish paints (2 coat) of TLP with labour, materials, transportation. 75 Nos. 910 211991 68,250
316 Supply and Installation of new TLP (A/B/C/D/E/I) with bend as per the drawing attached, along with diagram plate including necessary civil Foundation, excavation, backfilling etc excluding cost of cable 40 Nos. 16,726 211992 669,040
317 Supply and Installation of new TLP Type H with bend as per the drawing attached, along with diagram plate including necessary civil Foundation, excavation, backfilling etc. 10 Nos. 21,069 211993 210,690
318 Supply and Installation of new AJB with bend as per the drawing attached, along with diagram plate including necessary civil Foundation, excavation, backfilling etc. 3 Nos. 24,310 211994 72,930
319 Installation of new TLP along with necessary civil Foundation, excavation, backfilling etc. But excluding cost of cable. 3 Nos. 3,093 211995 9,279
320 Supply and installation of TLP/AJB/CJB doors along with necessary welding, hinges, allen bolts etc. Old damaged doors shall be handed over to GTL, if any 1 Nos. 2,653 211996 2,653
321 Cable to Pipe Joints by using Pin Brazing method. (Thermit weld not allowed) . This job includes necessary excavation, removal of coating, restoration of coating by Araldite Hardener and backfilling and restoring to original condition as per direction of EIC. Rate of cable supply shall be given as per relevant SOR mentioned elsewhere. Holiday Detection shall be done post restoration of coating. 15 Nos. 5,176 211997 77,640
322 Re-installation of TLP after shifting the existing TLP from its present location to a new location for better approachability including necessary cable laying & jointing but excluding Cable to Pipe connection. necessary civil Foundation, excavation, backfilling etc. included in the scope of work. but excluding cost of cable. Rate of cable supply shall be given as per relevant SOR mentioned elsewhere 10 Nos. 3,541 211998 35,410
323 Supply & Replacement of Mother Board in TR unit 1 Nos. 17,493 212000 17,493
324 Supply & Replacement of Display Board in TR unit 1 Nos. 10,881 212001 10,881
325 Supply & Replacement of Control Card in TR Unit 1 Nos. 7,084 212002 7,084
326 Supply & Replacement of Filter Circuit in TR Unit (LR Filter) 1 Nos. 2,725 212003 2,725
327 Supply & Installation of Analogue Panel Meter, Size 96 X 96, 230 Volt Operated (AC-Ameter,AC- Voltmeter) 5 Nos. 1,961 212004 9,805
328 Supply & Installation of Digital Volt Meter, Size 48 X 96, Aux Supply:- 230 Volts AC operated, 5 Nos. 1,961 212005 9,805
329 Supply & Installation of Digital Ammeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated, Range : 0-10 A, Display : 0-10 A 5 Nos. 1,961 212006 9,805
330 Supply & Installation of Digital Voltmeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated , Range : 0-20 VDC, Display : 0-20 VDC / 0-30 VDC 5 Nos. 1,961 213212 9,805
331 Supply & Installation of Digital Voltmeter, Size 48 X 96, Aux Supply:-5 Volts DC operated, Range : 0-200 VDC, Display : 0-200 VDC 5 Nos. 1,961 213214 9,805
332 Supply & Installation of Digital Ammeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated, Range : 0-75 mV, Display : 0-30 A 5 Nos. 1,961 212010 9,805
333 Supply & Installation of 4 - Position Rotary Switch used for Reference Electrode Selection. 1 Nos. 1,361 212011 1,361
334 Supply & Installation of 8 - Position Rotary Switch used for Reference Voltmeter Selection 1 Nos. 1,493 212012 1,493
335 Supply & Installation of 6 - Position Rotary Switch used for Reference Voltmeter Selection 1 Nos. 1,493 212013 1,493
336 Supply installation, Testing and commissioning of Signal Transducer (Converter) for PSP, Aux Supply:-230 Volts AC operated or 48 Volts DC operated, Input:-0-4 VDC, Output:-4-20 mADC. 1 Nos. 5,995 212014 5,995
337 Supply, installation, Testing and commissioning of Signal Transducer (Converter) for DCV, Aux Supply:-230 Volts AC operated or 48 Volts DC operated, Input:-0-60 VDC, Output:-4-20 mADC. 1 Nos. 5,995 212015 5,995
338 Supply, installation, Testing and commissioning of Signal Transducer (Converter) for DCA, Aux Supply:-230 Volts AC operated or 48 Volts DC operated, Input:-0-75 mVDC, Output:-4-20 mADC. 1 Nos. 5,995 212016 5,995
339 Supply and installation, Testing and commissioning of Kirk cell with enclosure (Rated capacity 5KA ) 10 Nos. 46,324 212017 463,240
340 Supply and Installation, Testing and commissioning of 21 Kgs of 99.99% pure Zinc grounding anodes with necessary backfill material with required excavation and backfilling, termination etc. 10 Nos. 23,053 212018 230,530
341 Maintenance of Kirk Cell along with supply of 30% pure KOH solution and a thin oil film along with replacement of of Kirk cell casing box (enclosure) if broken and cleaning of steel plates of Kirk cell. 10 Nos. 3,161 212019 31,610
342 Re-installation of Zinc Grounding anode which includes necessary excavation, cleaning of zinc anodes, and supply of backfill material along with necessary cotton bags. Additional required cable shall be claimed as per relevant SOR mentioned elsewhere 1 Nos. 4,087 212020 4,087
343 Supply and installation of a set of resistors and shunts for AJB of various ratings as per instruction of EIC. 20 Nos. 2,015 212022 40,300
344 Excavation of Anode Ground Bed in depth of one meter after providing and laying common salt of approx. 500 kgs and sufficient watering of ground bed. The job includes cost of salt, watering, excavation / backfilling charges etc. After completion of above job, circuit resistance is to be measured and recorded as per instruction of EIC 1 Nos. 11,893 212023 11,893
345 Supply, installation, testing and commissioning of considered High Silicon Cast Iron oxide anode of 21 Kgs weight and with canister, anode cable, metallurgical grade coke breed, auguring of appropriate size of hole , anode to cable joint and necessary termination as per standard practice and satisfaction of EIC 1 Nos. 22,493 212220 22,493
346 Supply, installation, testing and commissioning of considered MMO type anode of appropriate weight and with canister, anode cable, metallurgical grade coke breed, auguring of appropriate size of hole , anode to cable joint and necessary termination as per standard practice and satisfaction of EIC Rating for MMO type Anode: 1) Anode Shape and Dimensions: 750mm+/- 5mm Long 25.4 mm OD + 0.40/ -0.79 mm 1mm +/-0.1mm thick 2) Anode weight (without cable) 0.210 Kg/m +/- 0.021 Kg/m 1 Nos. 35,755 212024 35,755
347 Supply & Installation of permanent reference Cell (Cu-CuSO4) with 30 mtr tail cable (Make: MC Miller USA or HARCO USA) with a warranty of minimum 2 years from date of installation at existing or new location of pipeline, including excavation, backfilling, supply and installation of 1" PVC pipe for watering and connection complete in all respect as per instruction of EIC. Additional cable if any required shall be claimed as per relevant SOR mentioned elsewhere. 6 Nos. 21,271 212026 127,626
348 Supply & Installation, Testing & commissioning 10 Kg of magnesium anode with required cable length, excavation & backfilling of soil complete as per standard specification & EIC instructions 3 Nos. 13,881 212028 41,643
349 Removals of corrosion coupon by excavation, sending it to the lab for analysis, submit the report with analysis and recommendations. The area should be backfilled after removal of CC. The work includes all labour cost and laboratory analysis cost. 1 Nos. 14,151 212029 14,151
350 Supply, Laying & Termination (using lugs, ferrules & double compression type FLP glands) of FRLS Cable Under-Ground including Excavation & Backfilling etc. (At depth of 0.7 to 1.2 mtrs, sand packing of 250 mm and brick covering) with supply of sand & bricks including termination of cable at both ends with supply of appropriate size of glands, lugs etc.and cable jointing. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable etc.
350.1 1C x 6mm2 armoured copper cable with PVC insulation and FRLS Characteristics 300 Mtr. 245 212030 73,500
350.2 1C x 4mm2 armoured copper cable with PVC insulation and FRLS Characteristics 1 Mtr. 234 212031 234
350.3 1C x 10mm2 armoured copper cable with PVC insulation and FRLS Characteristics 100 Mtr. 322 212032 32,200
350.4 1C x 25mm2 armoured copper cable with PVC insulation and FRLS Characteristics 100 Mtr. 469 212033 46,900
350.5 3C x 16mm2 armoured copper cable with PVC insulation and FRLS Characteristics 1 Mtr. 716 212034 716
351 Supply & Installation, Testing & commissioning of Solid state electronic polarization cell of 5KVA 1 Nos. 148,033 212035 148,033
352 Supply & Installation, Testing & commissioning of Surge diverter -10KVA / 8-20 usec 4 Nos. 17,870 212036 71,480
353 Supply & Installation, Testing & commissioning of Pre packed zinc grounding cell 12.5 kg wt X 2 nos with 6M-10 sqmm cu, PVC unarmoured tail cable prepacked in chemical backfill with required backfilling, excavation and termination etc as per instruction of EIC 1 Nos. 27,206 212037 27,206
354 Supply of Portable reference electrode Cu-CuSo4 2 Nos. 12,265 212038 24,530
355 Supply & Installation, Testing & commissioning of Electrical Resistance Probe 2 Nos. 71,980 212042 143,960
356 Supply, laying & commissioning of Zinc Ribbon for AC interreference grounding as out come of AC interference survey report 1 Per KG 1,560 212044 1,560
357 Laying & Termination/Cable Jointing of CP cable, which includes excavation & back filling. Additional SOR to be operated for CP Cable 10 Mtr. 294 212045 2,940
358 Laying and termination of CP cable for Insulating Joint for available clit on IJ. No need for Pin Brazing. All consumable like Funnel, M-Seal, Epoxy & Hardener etc in the scope of contractor. 1 Mtr. 315 212047 315
359 Supply and installation of 18 W LED lighting fixture. 6 Nos. 1,798 212204 10,788
360 Supply and Installation of 2*18W flameproof LED tube light suitable for battery room 20 Nos. 2,858 213033 57,160
361 Supply & Installation of following rating Integrated Solar Street light 30W consists of a Solar panel and LED luminary with built-in Lithium-ion / Lithium Ferro Phosphate battery (LiFePO4) battery of appropriate Ah Capacity and solar driver card with charge controller. In addition, LED luminary has a motion sensor to increase / decrease the LED light brightness on detecting any movement near the solar light. of standard make. with 2 years product warranty & Battery warranty 5 year. Also needs Designed for outdoor use. Completely waterproof (IP65 rating) design. Installation of this fixture to be done on existing Solar lighting pole (retrofit type) 10 Nos. 13,848 211634 138,480
362 Supply & Installation of following rating Semi-Integrated Solar Street light of 30 W consists of a Solar panel and LED luminary with built-in Lithium-ion / Lithium Ferro Phosphate battery (LiFePO4) battery of appropriate Ah Capacity and solar driver card with charge controller. In addition, LED luminary has a motion sensor to increase / decrease the LED light brightness on detecting any movement near the solar light. of standard make. with 2 years product warranty & Battery warranty 5 year. Also needs Designed for outdoor use. Completely waterproof (IP65 rating) design. Installation of this fixture to be done on existing Solar lighting pole (retrofit type) 10 Nos. 13,195 213527 131,953
363 Repairing & re-installation of following rating Integrated Solar Street light of 30W fixtures which is consists of a Solar panel and LED luminary with built-in Lithium-ion / Lithium Ferro Phosphate battery (LiFePO4) battery and solar driver card with charge controlled and motion sensor. The Job shall includes replacement of faulty LED, PV Module, Motion sensors, LION Battery etc as per requirement. 1 Nos. 6,701 3000587 6,701
364 Supply and Installation of following size Four Way/Multiway Flameproof Junction box of Approved Make as per the GTL Vendor list attached with this tender. Suitable for Gas Group IIA, IIB, Ex d type, CMRI/PESO Approved ZONE-1 & ZONE-2. IP-65/66, Unused Cable entry shall be sealed with appropriate FLP plug
364.1 Ex d IIA/IIB 4 Way Junction box 100 Dia. 2 Nos. 5,807 212693 11,614
364.2 Ex d IIA/IIB Multi Way Junction box 170 Dia. 5 Nos. 7,594 212694 37,970
364.3 Ex d IIA/IIB Multi Way Junction box 260 Dia. 5 Nos. 11,167 212695 55,835
364.4 Ex d IIA/IIB Multi Way Junction box 340 Dia. 5 Nos. 16,528 212696 82,640
364.5 Ex d IIA/IIB Multi Way Junction box 700 X 700 mm 5 Nos. 31,270 212697 156,350
365 Supply of Swing Pedestal fan, 230V, 1-Phase, 400 mm sweep. 2 Nos. 4,020 212704 8,040
366 Supply and Installation of Exhaust Fan Louvers
367 Following Spares for Supply & Installation shall be considered for the Heating skid Operation & Maintenance Work.
367.1 UV sensor (Make : Honeywell, Model: C7027A 1023) 1 Nos. 14,294 212729 14,294
367.2 Flame relay (230 VAC) (Make : Honeywell, Model: R4343 E1048) 1 Nos. 22,336 212730 22,336
367.3 Ignition transformer (Make : Honeywell, Model: ET 401 ), Broad Specification : Input 230 VAC Ignition cable Plug in type spark current 20 mA 1 Nos. 7,147 212731 7,147
367.4 Ignition cable (Make : Belden, Model : High temperature 7mm Metallic cable) 5 R. Mtr. 8,488 212732 42,440
368 Supply & installation of Lighting Arrester as per latest relevant IS/IEC Code. All tools/tackles/manpower/material/transportation in the scope of contractor, 2 Nos. 7,108 212945 14,216
369 Supply and Installation of LED Flood light 150 W as per the GTL Vendor list. 1 Nos. 15,639 212947 15,639
370 Supply & Installation Electrical panel lock 60 Nos. 200 213528 12,000
371 Supply and installation of UV laminated and rewritable earth pit tag plate of 4 mm ACP sheet of size (10" x 8"), along with 20 mm dia pipe of 750 mm length with necessary civil work. Tag should mentioned pit no., resistance, test date and due date. 300 Nos. 50 213529 15,000
372 Alternate Current Voltage Gradient (ACVG) based on CIPL / CAT survey report and recommendations and submit complete detail report along with fault location drawing and recommendations. 6 kms 5,000 213530 30,000
373 Off potential measurement
373.1 Hazira Mora Pipeline: Total No of TLP are 24 Nos 1 Nos. 12,000 213579 12,000
373.2 Mora Utran Pipeline: Total No of TLP are 32 Nos 1 Nos. 16,000 213580 16,000
373.3 Mora-Kribco Pipeline: Total No of TLP are 9 Nos 1 Nos. 4,500 213581 4,500
373.4 Mora-Sajod Pipeline: Total No of TLP are 77 Nos 1 Nos. 38,500 213582 38,500
373.5 PMT Pipeline: Total No of TLP are 12 Nos 1 Nos. 6,000 213583 6,000
373.6 Mora-NTPC pipeline: Total No of TLP are 3 Nos 1 Nos. 1,500 213584 1,500
373.7 Mora-Vapi Pipeline: Total No of TLP are 200 Nos 1 Nos. 100,000 213585 100,000
373.8 Cairn-Mora Pipeline: Total No of TLP are 16 Nos 1 Nos. 8,000 213586 8,000
373.9 TPPL diaX 22 Kms, 33 TLPs 1 Nos. 16,500 213587 16,500
373.10 OUPL dia X 17Kms, 32 TLPs 1 Nos. 16,000 213588 16,000
373.11 ONGC OLPAD dia X 3.5Kms, 7 TLPs 1 Nos. 3,500 213589 3,500
373.12 Hazira Ankleshwar Pipeline: Total No of TLP are 120 Nos 1 Nos. 60,000 213590 60,000
373.13 Eklera Srikrishna Sarigam Pipeline: Total No of TLP are 26 Nos 1 Nos. 13,000 213591 13,000
373.14 Silvasa Connectivity Pipeline: Total No of TLP are 27 Nos 1 Nos. 13,500 213592 13,500
373.15 Chandol-Vapi-Vapi GIDC Total No of TLP are 24 Nos 1 Nos. 12,000 213593 12,000
373.16 Raymond TOP-Raymond Receiving Total No of TLP are 5 Nos 1 Nos. 2,500 213594 2,500
373.17 Rubby-Welspun/Alok Total No of TLP are 4 Nos 1 Nos. 2,000 213595 2,000
374 Supply and mobilization of Nitrogen gas of commercial grade in loose Cylinder / banks of individual cylinder capacity 7m3 at a pressure of 150 kg/Sq cm with all connecting hoses and de-mobilization after completion of job including loading, unloading, handling Cylinder pressure regulator and pressure gauge with accessories. No separate charges shall be paid for manpower, tools & tackles, lifting equipment's used during this activity. 80 Nos. 670 3000600 53,600
375 Removal, Refilling, hydrotesting & re-installation after painting of CO2 Gas cylinders used for flooding system of Water Capacity: 68 Ltr/N2 cylinder Capacity 48 ltr including to & fro transportation. (CO2 refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower, tools & tackles, lifting equipment's used during this activity. 40 Nos. 8,000 213532 320,000
376 Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GTL at designated stores. No separate charges shall be paid for transportation of cables from GTL designated stores to the site, manpower, consumables, equipment's, tools & tackles used during execution of this activity
376.1 Instrument cable up to 2P x 1.5sqmm armoured cable 1 Mtr.. 147 210878 147
376.2 Instrument cable up to 6P x 1.5sqmm armoured cable 1 Mtr.. 147 210879 147
376.3 Instrument cable up to 12P x 1.5sqmm armoured cable 1 Mtr.. 172 210880 172
376.4 2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr.. 531 209116 531
376.5 3 C x 1 Sq mm Armoured Power Cable 1 Mtr.. 295 210901 295
376.6 2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr.. 357 210902 357
377 Supply & Installation of GI Cable Trays with cover on MS steel support. All Accessories shall be in the scope of contractor like MS angle support , channel,Fastners, Clamp, Cable tie etc. as per below mentioned size
377.1 Perforated Cable tray with cover 450 mm 5 Mtr. 1,373 500754 6,865
377.2 Perforated Cable tray with cover 300 mm 5 Mtr. 983 500755 4,915
377.3 Perforated Cable tray with cover 150 mm 5 Mtr. 628 500756 3,140
377.4 Perforated Cable tray with cover 100 mm 5 Mtr. 452 500757 2,260
377.5 Ladder type Cable tray 450 mm 5 Mtr. 1,348 500758 6,740
377.6 Ladder type Cable tray 300 mm 5 Mtr. 1,204 500759 6,020
377.7 Ladder type Cable tray 150 mm 5 Mtr. 839 500760 4,195
378 Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The insulation resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity
378.1 Instrument cable up to 1P x 1.5sqmm armoured cable 200 Mtr.. 437 208702 87,400
378.2 Instrument cable up to 2P x 1.5sqmm armoured cable 200 Mtr.. 491 208703 98,200
378.3 Instrument cable up to 6P x 1.5sqmm armoured cable 50 Mtr.. 711 209117 35,550
378.4 Instrument cable up to 12P x 1.5sqmm armoured cable 50 Mtr.. 991 209118 49,550
379 Supply and Installation of "U" Clamps of SS material of standard type with NPT at bolting end including polyethylene insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. This include removal of old rusted U Clamps.
380 Painting of OPD Pole/PGD Pole including surface preparation, supply of paint and application of 2 coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy paint of Silver colour approved make as per the GTL Vendor list attached with this tender to give an even shade after proper removal of existing paint by suitable method and clearing of surface free from foreign materials. No separate charges shall be paid for manpower, consumables, equipment's, letter writing of tag Number, tools & tackles used during execution of this activity.
380.2 Upto 4.5 Meter Height Pole (OPGD/PGD etc pole in process area) 40 Nos. 1,407 212609 56,280
381 Supply & Installation of 12V 18 AH SMF Battery 5 Nos. 1,029 3000530 5,145
382 Supply & Installation of GTL approved makes Cooling/Ventilation fan in control panel axial fan 220V
383 Supply of panel cover for modular piano switches of different sizes. 1 Nos. 599 211673 599
384 Supply & Replacement of door hinges in instrument local control panel / RTU panel /Electrical panels. 20 Nos. 925 500656 18,500
385 Supply & Replacement of door Lock in instrument local control panel / RTU panel /Electrical panels. 20 Nos. 1,307 500657 26,140
386 Supply & Replacement of light and fixture for panel door in instrument local control panel / RTU panel. 20 Nos. 1,034 500658 20,680
387 Supply & Replacement of Selector switch in Instrument local control panel. 5 Nos. 1,199 500659 5,995
388 Supply & Replacement of Panel Hooter, Supply Voltage 230Vac / 24 Vdc as per GTL requirement for instrument panel and F & G and CO2 flooding system. 5 Nos. 3,269 500660 16,345
389 Supply & Replacement of FLP & WP Field Hooter , Supply Voltage 230Vac / 24 Vdc as per GTL requirement for Gas Detection System. 5 Nos. 6,649 500661 33,245
390 Supply & Replacement of FLP & WP Flasher (Yellow/Red) , Supply Voltage 230Vac / 24 Vdc as per GTL requirement for Gas Detection System. 5 Nos. 8,175 500662 40,875
391 Supply & Replacement of Power Supply Converter, 230 Vac to 24 Vdc, 10A. 10 Nos. 4,904 500668 49,040
392 Removal and Re-installation of Regulator Valve ( Either Active or Monitor) of size mentioned below. Size of regulator valve to be considered as per Inlet size of Regulator. No separate charges shall be paid for manpower, consumables, lifting equipments,Valve operation, venting activity,dismenteling & installation of tubing, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.
393 Removal and Re-installation of SSV Valve of size mentioned below. No separate charges shall be paid for manpower, consumables, lifting equipment's, tools & tackles used during execution of this activity. Maintenance to ne perform Gasket shall be supplied by GTL at designated store.
394 Removal and Re-installation of Flow Control Valve of size mentioned below. No separate charges shall be paid for manpower, consumables, lifting equipment's, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.
395 Preparation of cable schedule and termination detailing of existing cables of all panels the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement. 1 per panel 8,219 211706 8,219
396 Relocation of panel (Base frame Mounted)- Isolation of the existing panels by Dismantling/ Disconnection of cables, earthing's, tag-welding etc as to make them fully isolated from the existing setup and shifting & erection of panels on MS frame at new location, the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement (separate charges shall be paid for MS steel frame & earthing connectivity as per relevant SOR SOR). The size of floor mounted panel shall be up to 2100 X 1000 X 1200 (HxDxW) (in mm). The maximum weight shall be consider up to 2 tons. 1 per panel 25,685 211707 25,685
397 Supply laying and Termination (using Conduit, Rojet Box,temrinal block, crimping, connectors) of telecom & network cables. The Insulation Resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity.
397.1 Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 5 Pair 1 Mtr. 678 3000596 678
397.2 Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 10 Pair 1 Mtr. 884 3000597 884
397.3 Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 50 Pair 1 Mtr. 884 211749 884
397.4 Flexible 2 pair Telephone cable 1 Mtr. 298 210912 298
397.5 Up to 1 sqmm control cable 1 Mtr. 350 211750 350
397.6 RG-11 Video Cable 1 Mtr. 300 3000598 300
397.7 Optical Fiber Patch chord with connector as per GTL requirement- 1 pair - Up to 25 meter length 1 Mtr. 623 213203 623
397.8 CAT 6 Ethernet cable 1 Mtr. 300 211752 300
398 Gas detection System
398.1 Pole for Open path gas detector--150mm dia pole with 4.5 mtr height 10 Nos. 2,680 212642 26,800
398.2 Pole for point gas detector - 2.0 mtr height 20 Nos. 2,233 212643 44,660
399 Mechanical water meters (Asionic 400W or equivalent make) supply and installation. Contractor shall submit catalogue for GTL approval before supply
400 Supply and Installation of CO2 /FM 200 Flooding System spares as follows.
400.1 Supply & Installation Master card (10-036 A) 1 Nos. 20,377 212751 20,377
400.2 Supply & Installation Slave card (10-048B) 1 Nos. 16,587 212752 16,587
400.3 Repairing of Master card 2 Nos. 11,847 212753 23,694
400.4 Repairing of Slave card 6 Nos. 9,951 212754 59,706
400.5 Supply & Installation 7805 IC with Heat Sink 5 Nos. 4,739 212755 23,695
400.6 Supply & Installation Battery charger card 5 Nos. 2,369 212756 11,845
400.7 Supply & Installation 15017 card 5 Nos. 4,739 212757 23,695
400.8 Supply & Installation SMPS 5 Nos. 4,904 212758 24,520
400.9 Supply & Installation new EPROM set with Programming 4 Nos. 12,795 212759 51,180
400.10 Supply & Installation relay card 3 Nos. 16,587 212760 49,761
400.11 Supply & Installation PCB card 3 Nos. 13,743 212761 41,229
400.12 Supply & Installation memory enable lock & key 5 Nos. 8,056 212762 40,280
400.13 Supply & Installation multicriteria Photo electric Smoke/Thermal/Optical smoke Detector 30 Nos. 2,891 212763 86,730
400.14 Neck Ring for CO2 cylinder 10 Nos. 1,184 212764 11,840
400.15 Online weight monitor with interconnecting cable 5 Nos. 11,847 212765 59,235
400.16 Manual call point 15 Nos. 2,071 212766 31,065
400.17 Supply & Installation Valve for Master Cylinder 1 Nos. 34,595 212767 34,595
400.18 Supply & Installation Valve for Slave Cylinder 1 Nos. 34,595 212768 34,595
400.19 Ball Valve with Electrical Actuator 1 Nos. 43,125 212769 43,125
400.20 Hose pipe (3/8”) with Hydro test certificate 20 Nos. 1,564 212770 31,280
400.21 Hose pipe (1/4”) with Hydro test certificate 20 Nos. 1,199 212771 23,980
400.22 Linear Heat Sensor cable 100 R. Mtr. 966 212772 96,600
400.23 Hooter with flasher 5 Nos. 2,037 212773 10,185
400.24 Electric Siren (1 KM range) 3 Nos. 6,113 212774 18,339
400.25 Manual release push Button with cover 15 Nos. 520 212776 7,800
400.26 Supply & Installation Keypad card 5 Nos. 2,891 212777 14,455
400.27 Supply & Installation Siren Electronic Card 5 Nos. 5,260 212779 26,300
400.28 Supply & Installation Zone Display card 3 Nos. 12,795 212780 38,385
400.29 Electrical LED Type Warning Sign Board 3 Nos. 2,449 212781 7,347
400.30 Supply & Installation Pressure Switch 2 Nos. 6,236 212782 12,472
400.31 Supply & Installation NRV (Connected to Header) 5 Nos. 5,165 212783 25,825
401 Supply and replacement of MIMIC Diagram 18 Nos. 1,943 212789 34,974
402 Supply and replacement of Limit Switch of cylinder weight indicator 5 Nos. 520 212790 2,600
403 Supply and Installation of FM200 Flooding System spares as follows.
403.1 Zone Module (FA:5:ZM:504-C) 1 Nos. 5,686 212792 5,686
403.2 Mode Selection Module -1 : (FA:5:M:517 A) 1 Nos. 4,739 212793 4,739
403.4 Mother Board MB:1:507 1 Nos. 4,739 212795 4,739
403.5 Output Relay board (FA:5:518:A) 1 Nos. 2,369 212796 2,369
403.6 Power Module : (FAS:5:PS:501) 1 Nos. 7,108 212797 7,108
403.7 Monitor Module: (FAS:5:MM:502-A) 1 Nos. 4,739 212798 4,739
403.8 Control Module : ( FAS:5:CM:503-A) 1 Nos. 7,108 212799 7,108
403.9 Annunciator Window PCB: AA-266A 1 Nos. 4,739 212800 4,739
403.13 Discharge valve (Part no:00-100000-000, make-CRYPTZO) for FM200 Cylinder 1 Nos. 6,161 212784 6,161
403.14 Discharge Hose (Part No: 14-000001-000, Make-CRYPTZO) for FM200 Cylinder 1 Nos. 711 212785 711
403.15 Electrical cum manual actuator (Part No: 14-000031-000, Make-CRYPTZO) for FM200 Cylinder 1 Nos. 11,374 212786 11,374
403.16 Check valve (Part No: 14-000060-000, Make-CRYPTZO) for FM200 System 1 Nos. 5,686 212787 5,686
404 Removal, hydrotesting, Refilling & re-installation of FM 200 Gas cylinders used for flooding system of Water Capacity: 68/80/120 Ltr, Pressure: 48 Kg/Cm2 including to & fro transportation. (FM200 refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower, tools & tackles, lifting equipment's used during this activity.
404.1 FM200 gas Cylinder with 68/80/120 Ltr WC 1 Nos. 284,345 212806 284,345
404.2 FM 200 gas refilling 1 Kg 4,739 212808 4,739
405 Supply and Installation of LED Gate light 40 W with fixture 1 Nos. 15,639 212809 15,639
406 Supply of Canister For Checking of point gas detector 4 Nos. 5,449 212817 21,796
407 Supply, installation/replacement of up to 6" Dial and up to 210 Bar range Pressure Gauge 5 Nos. 14,217 212896 71,085
408 Supply, installation/replacement of up to 6" Dial and up to 100 Deg C Temperature Gauge 2 Nos. 14,217 212897 28,434
409 Supply, installation/replacement of up to 6" Dial and 0-2 Bar Differential Pressure Gauge 1 Nos. 11,847 212898 11,847
410 Supply, installation/replacement of Analog Input Barrier approved make 1 Nos. 4,739 212901 4,739
411 Supply, installation/replacement of Analog Output Barrier approved make 1 Nos. 4,739 212902 4,739
412 Supply, installation/replacement of Digital Input Barrier approved make 1 Nos. 5,781 212903 5,781
413 Supply, installation/replacement of Digital Output Barrier approved make 1 Nos. 5,781 212904 5,781
414 Supply, installation/replacement of Pulse Input Barrier approved make 1 Nos. 4,265 212905 4,265
415 Supply, installation/replacement of Proximity Switch (Make-Pepperl+Fuchs, Model No-NJ5-11-N-G) 1 Nos. 6,634 212906 6,634
416 Supply, installation/replacement of Proximity Switch (Make-Pepperl+Fuchs, Model No-NCB2-V3-NO) 1 Nos. 6,634 212907 6,634
417 Supply of Helium Gas (Helium Gas For Gas Chromatograph) 1) ( Purity of Gas 99.999%, (Grade 5) 2) Allowable impurity level (V/V)% (V/V%, PPM, MAX: - Ar < 2, O2 < 2, H2O <2, CO+CO2 <1, Thc <0.5, Cl2+Hg+S-Comp <0), 3) Cylinder Capacity 47 Ltrs Water Capacity , 4) Cylinder filling Pressure -150 Kg/cm² (+/- 5 kg/cm2), 5) Helium Gas Volume per Cylinder- 7.0 m³ ,6) Stability Gas -Stability of Helium Gas must be valid for at least One Year from the date of re-filling. , 7) Supply of Cylinders -Refilling to be done in Cylinders supplied by GTL, 8) Freight, loading and unloading of Cylinders and door delivery are in vendor scope, To and Fro transportation, 9) Gas composition Certificate-Lab analysis Certificate Required for each cylinder with traceability. 10) Lab Facility-The Bidder shall preferably have in-house laboratory infrastructure equipped with analysers and instruments necessary for helium gas analysis. In the event that such facilities are not available with the Bidder, the analysis and testing of helium gas shall be mandatorily undertaken at either (i) the Manufacturer’s laboratory, or (ii) any reputed/NABL-accredited laboratory. 1 Cu mtr. 3,000 213533 3,000
418 Supply and install Helium Cylinder Regulator (inlet 150 KG/CM2, outlet -0-15 KG/CM2) 1 Nos. 7000 213534 7,000
419 Hydro testing of Cylinder (which are due for hydro test, shall be Hydro tested at 225 Kg/cm² and CCOE approved test certificate has to be submitted. Vendor has to quote separately for Hydro testing charges) 1 Nos. 1800 213535 1,800
420 Arrangement and supply of water in tanker/truck/lorry only for fire fighting during emergency/mock drill. 10,000 Litres 1 Nos. 3,752 208676 3,752
421 Arrangement of fire tender during critical/Hot work/mock drill/Shutdown activities 1 Per 8 hrs. 33,174 212886 33,174
422 Arrangement of ambulance during critical/Hot work/mock drill/Shutdown activities 1 Per 8 hrs. 23,696 212887 23,696
423 Spares of Fire Extinguishers used during Maintenance and HSE items
423.1 Painting of up to 2 kg. CO2 Cylinder 30 Nos. 189 210137 5,670
423.2 Painting of 4.5 kg. CO2 Cylinder 30 Nos. 284 210138 8,520
423.3 Painting of 6.5 kg. CO2 Cylinder 1 Nos. 331 211550 331
423.4 Painting of 9.0 Kg. CO2 Cylinder 60 Nos. 427 210139 25,620
423.5 Painting of ABC F/E 6.0 Kg (SP). 30 Nos. 236 212567 7,080
423.6 Painting of DCP FE 9.0 Kg 5 Nos. 284 210142 1,420
423.7 Painting of DCP/ABC F/E 25.0 Kg 50 Nos. 473 210144 23,650
423.8 Painting of DCP/ABC F/E 75.0 Kg 15 Nos. 711 210145 10,665
423.9 Painting of ABC F/E 2 Kg. Capacity(SP) 10 Nos. 189 212911 1,890
423.10 Painting of ABC F/E 9 Kg. Capacity (S P) 35 Nos. 284 210522 9,940
423.11 Hydro Pressure Test up to 2 kg CO2 Cylinder 25 Nos. 427 210146 10,675
423.12 Hydro Pressure 4.5 kg CO2 Cylinder 25 Nos. 520 210147 13,000
423.13 Hydro Pressure Test 6.5kg CO2 Cylinder 1 Nos. 520 211551 520
423.14 Hydro Pressure Test 09.0 Kg. CO2 Cylinder 25 Nos. 711 210148 17,775
423.15 Hydro Pressure Test ABC 6 Kg FE (SP) 25 Nos. 236 212570 5,900
423.16 Hydro Pressure Test 09 Kg. DCP Cylinder 1 Nos. 236 210151 236
423.17 Hydro Pressure Test 09 Kg. ABC Cylinder(SP) 25 Nos. 236 210526 5,900
423.18 Hydro Pressure Test DCP/ABC 25 Kg FE 30 Nos. 473 210153 14,190
423.19 Hydro Pressure Test DCP/ABC 75 Kg FE 25 Nos. 711 210154 17,775
423.20 Hydro Pressures ABC F/E 2 Kg Capacity 1 Nos. 236 213194 236
423.21 Refilling of 2.0 kg CO2 Cylinder 2 Nos. 427 210122 854
423.22 Refilling of 4.5 kg CO2 MS body 15 Nos. 545 212994 8,175
423.23 Refilling of 6.5 kg CO2 Cylinder 1 Nos. 639 212912 639
423.24 Refilling of 9.0 kg CO2 Cylinder 25 Nos. 734 210125 18,350
423.25 Refilling of 9.0 kg DCP F/E 25 Nos. 616 213100 15,400
423.26 Refilling of 25 kg ABC F/E -With 90% MAP Powder & Filling CO2 30 Nos. 3,058 213101 91,740
423.27 Refilling of 75 kg ABC F/E -With 90% MAP Powder & Filling CO2 25 Nos. 9,285 213039 232,125
423.28 Refilling of 2 kg ABC F/E -With 90% MAP Powder & Filling N2 10 Nos. 546 213040 5,460
423.29 Refilling of 6 kg ABC F/E -With 90% MAP Powder & Filling N2 25 Nos. 1,091 213041 27,275
423.30 Refilling of 9 kg ABC F/E -With 90% MAP Powder & Filling N2) 25 Nos. 1,420 213102 35,500
423.31 Refilling of CO2 Gas Cartridge 200 Grams 1 Nos. 142 210133 142
423.32 Refilling of CO2 Gas Cartridge 1.0 kg 5 Nos. 427 210135 2,135
423.33 Refilling of CO2 Gas Cartridge 2.0 kg 5 Nos. 427 210136 2,135
423.34 Refilling nitrogen for ABC F/E 2 kg(SP) 1 Nos. 189 213043 189
423.35 Refilling nitrogen for ABC F/E 6 kg(SP) 25 Nos. 236 212565 5,900
423.36 Refilling nitrogen for ABC F/E 9.0 kg(SP) 25 Nos. 284 210518 7,100
423.37 Brass Operating CAP for DCP F/E 1 Nos. 520 213204 520
423.38 Operating Cap with Safety Valve -DCP 1 Nos. 995 501031 995
423.39 PVC Discharge Hose for 6 Kg ABC F/E 15 Nos. 189 213103 2,835
423.40 PVC Discharge Hose for 9Kg ABC/DCP 15 Nos. 236 501032 3,540
423.41 PVC Discharge Hose for 25.0Kg DCP/ABC (3 Mtr. Long) 15 Nos. 520 501471 7,800
423.42 PVC Discharge Hose for 75Kg DCP/ABC (5 Mtr. Long) 15 Nos. 805 501033 12,075
423.43 Spray Nozzle 6 kg. F/E ABC 5 Nos. 75 213104 375
423.44 ABS Plastic Squez Grip Nozzle up to 9 kg DCP/ABC 5 Nos. 142 213105 710
423.45 Hose Clamp 5 Nos. 28 501035 140
423.46 Brass Chromium Plated Safety Clip with chain 1 Nos. 28 501472 28
423.47 Rubber Cap Washer - DCP 1 Nos. 28 501037 28
423.48 RUBBER BUSH,SCREW & WASHER up to 9 KG - ABC 25 Nos. 19 501038 475
423.49 Inner Container 9/25 Kg. -DCP 25 Nos. 331 500295 8,275
423.50 Wall Brackate 2/5/6/9/10 Kg. - DCP 1 Nos. 28 501810 28
423.51 Rubber Guard For Nozzle -DCP 1 Nos. 9 501041 9
423.52 Pressure Gauge For 25/75 kg.- DCP 25 Nos. 427 501811 10,675
423.53 Trolley Wheel -25 / 75Kg. -DCP 1 Nos. 236 501812 236
423.54 Trolley Wheel Set - 25 / 75 Kg -DCP 1 Nos. 1,184 501044 1,184
423.55 PVC sticker for F/E (DCP/ABC) showing Instruction of usage & applicability of FE 40 Nos. 37 501821 1,480
423.56 Connecting Hose Between CO2 Pilot Cylinder up to 75KG 25 Nos. 284 501475 7,100
423.57 Shutoff Nozzle for 25/75KgDCP F/E 1 Nos. 1,089 501046 1,089
423.58 Spring loaded safety valve-DCP 5 Nos. 427 501047 2,135
423.59 Dry Chemical Powder (Sodium Bi-carbonate) with ISI Mark 5Kg 1 Nos. 42 501476 42
423.60 Dry Chemical Powder (90% MAP) with ISI Mark up to 5/6 Kg 25 Nos. 75 501477 1,875
423.61 Pre Gauge:upto 2 kg ABC(Stored pre Type)F/E 10 Nos. 142 501478 1,420
423.62 Pre Gauge: 6 kg ABC(Stored pre Type)F/E 10 Nos. 142 501479 1,420
423.63 Pre Gauge: 9 kg ABC(Stored pre Type)F/E 10 Nos. 142 501480 1,420
423.64 PVC discharge hose 6 kg ABC (SPT) F/E 17 Nos. 142 212573 2,414
423.65 PVC discharge hose 9 kg ABC (SPT) F/E 25 Nos. 189 213205 4,725
423.66 Discharge Brass Nozzle 6 kg ABC (SPT)F/E 1 Nos. 95 501820 95
423.67 Discharge Brass Nozzle 9 kg ABC (SPT)F/E 1 Nos. 95 501481 95
423.68 Plunger 6 kg ABC (Stored pre Type) F/E 1 Nos. 331 212575 331
423.69 Plunger 9 kg ABC (Stored pre Type) F/E 1 Nos. 331 501482 331
423.70 "O" ring for 2/6/9 kg ABC (SPT) F/E 1 Nos. 19 501483 19
423.71 Brass Operating Cap Assembly-DCP 9Kg 1 Nos. 1,089 501049 1,089
423.72 PVC Discharge Hose+Open Spray Nozzle-9kg 5 Nos. 189 501050 945
423.73 ABS Plastic Siphon Tube-DCP up to 9Kg 1 Nos. 118 501051 118
423.74 Locking Pin for ABC type up to 9kg 27 Nos. 28 501056 756
423.75 Discharge Hose with Horn 1Mtr. for 4.5kg 10 Nos. 402 501054 4,020
423.76 Discharge Hose with Horn 3Mtr. for 9.0kg 10 Nos. 805 500273 8,050
423.77 Discharge Horn 4.5Kg 10 Nos. 142 501055 1,420
423.78 Discharge Horn 9.0Kg 10 Nos. 189 500275 1,890
423.79 Discharge Hose 4.5Kg 10 Nos. 331 501070 3,310
423.80 Discharge Hose 9.0Kg 10 Nos. 711 500277 7,110
423.81 Aluminium CO2 Locking Pin 30 Nos. 9 500278 270
423.82 Locking Holder 30 Nos. 47 501057 1,410
423.83 CO2 Neck Handle with Rubber Grip 2 Nos. 142 501058 284
423.84 M.S. Heavy Duty Wall Bracket CO2 F/E 1 Nos. 28 500311 28
423.85 Trolley Wheel - 9.0 Kg 1 Nos. 236 501484 236
423.86 Trolley Wheel Set - 9.0 Kg 1 Nos. 1,089 500313 1,089
423.87 Rubber Handle ( Hose Between Horn) CO2 1 Nos. 19 500314 19
423.88 MS Nipple ( Hose Between Horn) CO2 1 Nos. 19 501061 19
423.89 PVC sticker for F/E (CO2/ABC) showing Instruction of usage & applicability of FE 25 Nos. 37 212919 925
423.90 Acrylic sheet tag checking&Maint. 300 Nos. 37 212920 11,100
424 Supply of Items of First Aid Boxes
424.1 Supply & Replacement of Small Dressing Bandage for Finger Wound 50 Nos. 65 212922 3,250
424.2 Supply & Replacement of Medium Dressing Bandage for Hands & Feet Wound 50 Nos. 65 212923 3,250
424.3 Supply & Replacement of Absorbent cotton wool 30 Nos. 42 212924 1,260
424.4 Supply & Replacement of Antiseptic Solution (Dettol/Savlon) - 60ml 30 Nos. 43 102193 1,290
424.5 Supply & Replacement of Dressing Scissors 30 Nos. 47 212925 1,410
424.6 Supply & Replacement of Roll of Adhesive Plaster 2cms x 1 Mtr. USP 30 Nos. 48 212926 1,440
424.7 Supply & Replacement of Eye Pads 30 Nos. 35 212927 1,050
424.8 Supply & Replacement of Polythene Wash Bottle/Eye Cup for washing eyes 30 Nos. 23 212928 690
424.9 Supply & Replacement of Safety Pins of 110 Nos. 9 212929 990
424.10 Supply & Replacement of Potassium Permanganate (Used for cleaning wounds and dermatitis, fungal infections) 30 Nos. 53 212930 1,590
424.11 Supply & Replacement of Soframycin ointment (used for curing wounds, cuts, burns) 30 Nos. 53 212931 1,590
424.12 Supply & Replacement of triangle bandage 30 Nos. 37 212932 1,110
424.13 Supply & Replacement of Band Aid Strips 110 Nos. 23 212933 2,530
424.14 Supply & Replacement of ORS 1 Nos. 19 212934 19
424.15 Supply & Replacement of Pain Relief Spray 3 Nos. 208 212935 624
424.16 Supply & Replacement of First Aid Box 20 Nos. 805 212936 16,100
424.17 Supply & Replacement of Wind Sock Stand 1 Nos. 1,305 212937 1,305
424.18 Supply & Replacement of Wind Sock 1 Nos. 497 212938 497
425 Maintenance of SCBA set
425.1 Supply & replacement of shoulder strap assembly of SCBA 1 Nos. 15,374 212939 15,374
425.2 Overhauling of SCBA 1 Nos. 16,334 212940 16,334
425.3 Hydrotesting of SCBA cylinder 1 Nos. 1,895 212941 1,895
425.4 Refilling of SCBA cylinder 1 Nos. 946 501410 946
426 Supply of NON-PERCOLATING FLEXIBLE FIRE FIGHTING DELIVERY HOSE As per IS : 14933 Type 3 (B), 63 MM Dia with SS coupling as per IS : 903 (SS 304) and copper wire Binding. Length – 15 Meters 25 Nos. 5,000 213536 125,000
427 Supply & Installation of double door firefighting hose boxes made of MS plates of 3 mm minimum thickness with glass front. The size of the box should be adequate to accommodate double headed landing valves with 2 fire hose each of 15 m length, and one branch pipes. 15 Nos. 5,000 213537 75,000
428 Supply of Heavy Duty Sluice valves for fire hydrant network that conforming to IS:14846, of cast iron (FG200/FG260) bodies with non-rising stems, bronze seat rings, and PN1.0 or PN1.6 pressure ratings.
429 Supply of 63 MM, A Type - I Water Monitor as per IS 8442 is a stand-post mounted, manual fire-fighting monitor designed for high-capacity water delivery. Approx. 53 meters horizontal range and 21 meters vertical reach. 1750 LPM flow rate at 7 Kg/CM2. 360° horizontal, and a vertical movement of at least 125° (80 degree up and 45 degree down). 1 Nos. 35,000 213541 35,000
430 Service and maintenance of high pressure water mist trolley (Make : Swadeshi) 1 Nos. 25,000 213542 25,000
431 Washout repair job on existing buried pipeline, which occur mostly during monsoon period: Supplying and filling selected loose earth other than black cotton soil from borrowed pits in the washout/depressed land or in the pit locations of pipeline ROW compacting including cost of transportation, spreading, compacting, all as directed by engineer-in-charge. The rates includes royalty or any other levies by Govt. agencies towards taking of loose earth from borrowed area as per the direction of engineer-in-charge / site engineer inclusive all labour, materials, tools, tackles, transportation, taxes etc. completion all respect. (Payment shall be made on basis of measurement of the pit profile of the earth washout in the ROW) 500 Cu Mtr. 764 102027 381,812
432 Supply of radium sticker with lamination as per instructed by EIC 10 Sq. meter 500 213543 5,000
Total for One Year excluding GST 51,314,244
Total for Two Year excluding GST 102,628,489
Bidder to quote (-) % / Discount
Bidder to quote (+) % / Accreation
Bidded Total excluding GST 102,628,489
Note :- GST shall be at actual.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Surat Base grid Map.pdf
AMC Surat SOW.pdf
Annexure-1 Surat Base Pipeline details.xlsx
XLSX
Annexure-2 Details of Terminal Surat Base.xlsx
XLSX
Annexure-3 AMS.xlsx
XLSX
Surat AMC SOR rev-3 final.xlsx
XLSX
AMC Surat Comm. RFP.pdf
AMC Surat Bidding Schedule.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].