Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
26 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
REPAIR, MAINTAINENCE AND CLEANING OF SEWAGE LINES, SEPTIC TANK AND SOAKAGE WELL AT DEFENCE LAB JODHPUR
2020_MES_400214_1
8401/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) R AND D JODHPUR
AS PER TENDER DETAILS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,000
Yes
28 Dec 2020
3 Dec 2020
28 Dec 2020
3 Dec 2020
26 Dec 2020
12 Dec 2020
4 Dec 2020 - 11 Dec 2020
60 days
Amount
Cleaning/taking out sludge/mud/silt from manhole and septic tanks of any size and capacity manually or mechanically including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly all as specified and directed by Engineer-in-charge NOTE:-Sludge/muds/silt including water shall be measured before taking out from manholes/septic tank.
Taking out muddy/ sewage water from soakage pit by using of mechanical sewage/mud water diesel pump set of suitable power and dispossed off muddy/ sewage water in a closed container vehicle to a distance out side MD land complete all as specified and directed by Engineer-in-charge. Note:- All labour and T&P i.e. sewage water pump set, closed container vehicle, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account.
M&L cleaning of sewage pipe line up to 250mm bore by roding from manhole to manhole by manually / mechanically as per site requirement and flushing with water,and getting out sludge if collected in manholes and removing the solid and sludge to out side MD land and dispossed off,and refixing the man hole cover complete all as specified & directed by Engineer-in-Charge. NOTE:- The cost of removal shall be included in the quoted rate and nothing extra shall be admissible on this account.
Removing of blockage from WC/floor trap/Nahani and line up to gulley trap by roding or blockage remove manually by opening grating & refixing after removing all greese, muds,sludge,silts etc (blockage) complete all as specified and directed by Engineer-in-Charge.
Removing of blockage from gulley trap to first manhole by roding or blockage remove manually by opening manhole cover & refixing after removing all greese, muds,sludge,silts etc (blockage) complete all as specified and directed by Engineer-in-Charge.
M&L Plugging under-ground sewage line (150mm to 600mm) in manholes of any depth and removing the same after deslugging of soakage well / septic tank complete all as specified & directed by Engineer in charge.
Site clearance including clearing away all grass vegetation, saplings,shrubs, brushwood, undergrowth,roots,and trees not exceeding 30 cm in girth( measured at a height of one meter above ground level) and removing entire rubbish out side MOD land complete all as specified and directed by Engineer in charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete complete all as specified & directed by Engineer in charge.
M&L PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in benching/ channels of manholes etc complete all as specified and as directed by Engineer in charge.
M & L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and directed by Engineer in charge.
S & F 150 mm bore Reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed complete all as specified and as directed by Engineer in charge.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to150 mm bore salt glazed stone ware drain pipe/NP-2 pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed by Engineer in charge.
Returning filling in including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and directed by Engineer in charge.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and directed by Engineer in charge.
Dismantling 100 mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from walls/ trenches complete all as specified & directed by Engineer in charge
Dismantling 75mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from walls/ trenches complete all as specified & directed by Engineer in charge.
S & F 100 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified & directed by Engineer in charge.
S & F 100 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer in charge.
S & F 75 mm bire Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified & directed by Engineer in charge.
S & F 75 mm bire Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer in charge.
S & F in repairs Stack clamps made out of 50 mm by 3 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore pipecomplete all as specified & directed by Engineer in charge
S & F in repairs Stack clamps made out of 50 mm by 3 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore pipe complete all as specified & directed by Engineer in charge.
Demolition of cement concrete reinforced in roofs, floors (other than ground floors) beams, staircases, landing, chajjas, manhole cover slab and similar suspended work and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L precast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate in landings, cover slabs (for man holes etc) chullah hoods,chajjas,water troughs,shelves and similar articles with plain faces complete all as specified & directed by Engineer-in-charge.
M&L mild steel TMT bars 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M&L Mild steel round bars 10/12 mm dia and over cut to length, bent to shape as in handle of RCC cover slab of manholes complete all as specified & directed by Engineer in charge.
Dismantling of brickwork or stone/boulder masonry, built in cement mortar including all quoins arches, pillers etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
Dismantling of brickwork or stone/boulder masonry, laid dry and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) except stone complete all as specified & directed by Engineer-in-charge.
M&L squared rubble walling, Jodhpur type, laid dry, brought upto course and well bonded complete all as specified & directed by Engineer-in-chrge.
M&L squared rubble walling, Jodhpur type, laid dry, brought upto course and well bonded except stone complete all as specified & directed by Engineer-in-chrge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L, rendering 15 mm thick cement plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge.
S&F 5 cm thick sand stone slabs as in sun-shades, chajjas, shelves, cills, landings, cover stones,manhole cover, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
m/s Firoz khan
M/S JALAL KHAN
M/S IK CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .