Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.1 L+₹69,947.15 (13.1%)Rejected-AOC ELAVANCHERRY GP PALAKKAD | PALAKKAD | KERALA | 672122 | L2 | Rejected-AOC L2 |
Tender Value
₹5.5 L
EMD Value
₹13,826
Closing Date
14 Jan 2025, 2:00 pmClosed
AEE
WSP SUB DIVISION HARIPAD
STATE PLAN 2018-19-RWSS TO KARUVATTA-CONSTRUCTION OF TEMPORARY PUMP HOUSE LAYING PUMPING MAIN AND SUPPLY AND ERECTION OF PUMP SET AND COMMISSIONING OF NEW TUBE WELL IN WARD 10 -VAKKANACHAL OF KARUVATTA GRAMAPANCHAYATH
2025_KWA_723388_1
WRD/KWA-CE(CR)/TR/24841/2024
Open Tender
Civil Works - Water Works
Item Rate
60 days
WSP SUB DIVISION HARIPAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,220
₹13,826
Yes
6 Feb 2025
7 Jan 2025
15 Jan 2025
7 Jan 2025
14 Jan 2025
7 Jan 2025
Amount
APPENDIX A - PART 1 :- CIVIL WORK - CONSTRUCTION OF TEMPORARY PUMP HOUSE
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
9.95.3:Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:100x75x4 mm
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
APPENDIX B- PART II :- CONSTRUCTION OF PUMP HOUSE - ELECTRIFICATION WORK.
OD137096/2024-2025:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed mediumclass PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper Group B conductor single core cable etc. as required
OD137097/2024-2025:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with lSI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required. 63ATP&N
OD137098/2024-2025:Earthing with G.l. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate Jlaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required
OD137099/2024-2025:Installation, testing and commissioning of pre-wired, fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc.directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
OD137100/2024-2025:Supplying 36/40w Fluorescent Lamp with all accessories
OD137101/2024-2025:Supplying and fixing metal box of 200 mm X 125 mm X 60 mm size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
OD137102/2024-2025:Supplying and providing meter box and panel board for KSEB supply and providing necessary fuse unit and isolators for 3 phase supply as per the direction of departmental officers.
APPENDIX C - PART III :-LAYING PUMPING MAIN - WORKING CHARGES.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD137103/2024-2025:Interconnecting the newly laid 90 mm PVC. Pipe line to the existing line, by cutting the existing 63/75/90 PVC. Line diametrically, the cut being diametrically perpendicular to the axis of pipe and smoothening of cut ends, inserting the 63/75/90 mmx63/75/90 PVC ‘TEE’,63/75/90 mm CIR Joint supplied by the contractor and placing in position, jointing with solvent cement and testing to the required test pressure, including cost of ‘TEE supplied by the contractor, labour charges , and hire for tools etc; complete.
OD137104/2024-2025:Interconnecting the newly laid 90mm PVC pipe line to the existing 80mm GI pumping main using 80mm GI bend 2Nos, 80mm GI pipe -2.5m ,90mm PVC Threaded adaptor, 90mm PVC pipe,etc..to the newly laid 90mm PVC line and testing to the required test pressure ,including cost of necessary specials supplied by the contractor, labour charges, hire for tools etc. complete
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
100.47.1.4:Leak rectification work in 63mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
100.47.1.5:Leak rectification work in 75mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
100.47.1.6:Leak rectification work in 90mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
100.57.1:Rectifying the leakages in boring point of public tap connection including earth work excavation in all kinds of soil for exposing the boring point including concrete / tar cutting, dismantling the damaged saddle piece,cutting and removing damaged portion of pipe line,fixing new saddle piece,laying 20/25 mm PVC 10Kg/cm2 pipe in place of damaged portion of pipe and connecting with existing pipe line,testing the line to the required test pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of hire and conveyance of tools, plants and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, including cost of pipe and saddle piece and as per the direction of departmental officers etc. complete.
APPENDIX B - PART II :-LAYING PUMPING MAIN - COST OF MATERIALS
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
APPENDIX C :-SUPPLY, ERECTION AND COMMISSIONING OF SUBMERSIBLE PUMP SET
OD137089/2024-2025:Supplying 80 mm GI Class B pipe (weight not less than 8.5 Kg/m) having ISI mark
OD137090/2024-2025:Supplying good quality 80mm GI BEND
OD137091/2024-2025:Supplying 80mm GI Tee
OD137092/2024-2025:Supplying 3X4mm sq. submersible cable having ISI mark
OD137094/2024-2025:Providing bleaching powder solution feeding unit for disinfection of water consisting of supplying and providing polyethylene water storage tank (ISI marked) with cover and suitable locking arrangement of capacity 500 Ltr, providing platform of size 1.25 M x 1.00 M for placing PVC tank by structural steel work riveted, bolted or welded in built up sections including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using ISA 75 x 75 x 6, providing 20 mm CPVC pipe connection for inlet water supply to tank from pumping main and out let supply from tank to bottom of tube well including providing two number ball valves in inlet line and one valve in outlet line and providing 50 mm CPVC pipe darin outlet in tank for scovring arrangement including providing 50 mm PVC ball, valve in drain pipe and making the unit functional for collecting water from pumping main and continuous feeding of bleaching powder solution to tube well etc complete including cost and conveyance of polyethylene water storage tank (ISI marked) with cover and suitable locking arrangement of capacity 500 Ltr - 1 No, Steel structural platform using ISA 75 x 75 x 6 - 108 Kg, inlet and outlet pipe connection using 20 mm CPVC pipe and specials - 66 M and valves, drain arrangement all labour charges, supplying 30/40 Ltr PVC bucket - 2 Nos and PVC mug - 2 Nos (for mixing bleaching powder), hire charges of tools etc complete as per the direction of engineer in charge.
OD137095/2024-2025:Supply, conveying and fittings with specials of 80 mm Flexiible PVC hose
Suresh K (BID ID -2059793)
Bidder Name
C Jayaprasad
Suresh K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1148705.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .