| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.3 CrAccepted-AOC | ₹10.3 Cr Quoted ₹10.4 Cr | L-1 | Accepted-AOC L-1 firm in the tender |
| 2 | L-2₹11.0 CrRejected-AOC | ₹11.0 Cr | L-2 | Rejected-AOC L-2 frim in the tender |
| 3 | L-3₹14.1 CrRejected-AOC | ₹14.1 Cr | L-3 | Rejected-AOC L-3 frim in the tender |
| 4 | Rejected-Technical | - | - | Rejected-Technical PQC NOT FULLFILL |
Tender Value
Refer Docs
EMD Value
₹13 L
Closing Date
20 Sept 2023, 2:00 pmClosed
SE, EMCC-1, JTPS, Malawan, Etah
SE, EMCC-1, JTPS, Malawan, Etah
Biennial contract for maintenance of complete Electrical system of JTPS excluding CHP system.
2023_RVUNL_826124_1
ET07/EMCC-1/EMCD-XIII/2023-24
Open Tender
Repair and Maintenance Services
731 days
Jawaharpur Thermal Power Station, Malawan
As per PQC in tender specifications
2 documents required · 2 mandatory
₹11,800
Dy CAO, CFA BO, JTPS, Malawan
₹13 L
28 Oct 2024
3 Aug 2023
22 Sept 2023
3 Aug 2023
20 Sept 2023
3 Aug 2023
3 Aug 2023 - 20 Sept 2023
Amount
Part A: Lighting, welding and cabling network Maintenance of main plant & BOP areas
Round the clock operation & maintenance and Routine & breakdown maintenance of permanent station lighting system the lighting systems & Installation of new electrical points, light fittings/fixtures, lighting transformers, welding receptacle, Electrical wiring to provide new connection, Erection/repair of G.I. conduit pipe etc. including supply of Porta Cabin Prefabricated Quarters, Transit Field Hostel, round the clock operation of Substation for providing supply to Porta Cabin, Field hostel and prefabricated quarters 2X660MW inside the plant boundary.
Up keeping/cleaning of various cable vaults/galleries/trenches and racks
Excavation of trench
Routine/Breakdown maintenance of all exhaust fan and ventilation system at various places
Laying/ salvaging of power /control cables Of Dia up to 80 MM.
Jointing and end termination of control cables of all sizes
Jointing and End termination of LT power cables of all sizes
Jointing and End termination of HT power cables of all sizes
Painting of various type electrical equipments /panels, HT/LT busducts, HT/LT Transformers, HT/LT motors, Painting of Street lights poles and other electrical equipments
Fabrication & fixing of Canopy upto 1 Sq meter
Supplying of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size: 20 mm
Supplying of following size of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required
2 x 2.5 sq. mm,
2 x 4 sq. mm,
Supplying metal box of size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover as required
Size: 200x125x60 mm,
Size: 200x250x75 mm,
Supplying of piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 A switch,
15/16 A switch,
3 pin 5/6 A socket outlet,
5 pin 15/16 A socket outlet,
Supplying following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Rating: 25Amps
Supplying of rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
63 Amp and above,
PART-B: MAINTENANCE OF HT AND LT MOTORS
Routine and Preventive Maintenance of HT, LT& DC motors of main plant and offsite BOP area
LT MOTOR (<=2.2KW) Attend Defect
LT MOTOR (>2.2-5.5KW) Attend Defect
LT MOTOR (>5.5-18.5KW) Attend Defect
LT MOTOR (>18.5-37KW) Attend Defect
LT MOTOR (>37-55KW) Attend Defect
LT MOTOR (>55-90KW) Attend Defect
LT MOTOR (>90KW) Attend Defect
DC MOTORS(<=10KW)-Attend Defect
DC MOTORS(>10-20KW)-Attend Defect
DC MOTORS(>20KW) Attend Defect
LT MOTOR (<=5.5KW) Connection
LT MOTOR (>5.5-18.5KW) Connection
LT MOTOR (>18.5-37KW) Connection
LT MOTOR (>37-55KW) Connection
LT MOTOR (>55-90KW) Connection
LT MOTOR (>90KW) Connection
HT MOTORS Terminal connection / disconnection
LT MOTOR (<=2.2KW) OH / Servicing
LT MOTOR (>2.2-5.5KW) OH / Servicing
LT MOTOR(>5.5-18.5KW)-OH / Servicing
LT MOTOR(>18.5-37KW)-OH / Servicing
LT MOTOR(>37-55KW)-OH / Servicing
LT MOTOR(>55-90KW)-OH / Servicing
LT MOTOR(>90KW)-OH / Servicing
DC MOTORS(<=10KW)- OH/ Servicing
DC MOTORS(>10-20KW)-OH / Servicing
DC MOTORS(>20KW)-OH / Servicing
Deployment of highly skilled manpower for unscheduled jobs
Deployment of skilled manpower for unscheduled Jobs
Deployment of semi-skilled manpower for unscheduled jobs
HT MOTORS (<=1000KW) Attend Defect /Servicing
HT MOTORS (>1000-2500KW) Attend Defect /Servicing
HT MOTORS(>2500-5000kW)-Attend Defect / Servicing
HT MOTORS(>5000kW)-Attend Defect / Servicing
LT MOTOR (<=10 KW) Shifting/Replacement
LT MOTOR (>10- 30 KW) Shifting/Replacement
LT MOTOR (>30-75KW) Shifting/Replacement
LT MOTOR (>75-90 KW) Shifting/Replacement
LT MOTOR (>90KW) Shifting/Replacement
DC MOTORS(<=10KW)-Shifting/Replacement
DC MOTORS(>10-30KW)-Shifting/Replacement
DC MOTORS(>30KW) Shifting/Replacement
HT MOTORS (<=1000KW) Shifting/rotation
HT MOTORS (>1000-2500KW) Shifting/rotation
HT MOTORS(>2500-5000kW) Shifting/rotation
HT MOTORS(>5000kW) Shifting/rotation
Miscellaneous machining/ repairing works
Rewinding of 3-Phase 440V induction motor
Up to1.0 KW
Above 1.0 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 20 KW
Above 20 KW up to 30 KW
Above 30 KW up to 40 KW
Above 40 KW up to 55 KW
Above 55 KW up to 70 KW
Above 70 KW up to 80 KW
Above 80 KW up to 100 KW
Above 100 KW up to 110 KW
Above 110 KW up to 135 KW
Above 135 KW up to 145 KW
Above 145 KW up to 300 KW
Rewinding of Single phase 240V AC induction motor
Up to 1.0 KW
Rewinding of 220V DC Motor/Generator
Up to 1 KW
Above 1 KW up to 5 KW
Above 5 KW up to 20 KW
Above 20 KW up to 40 KW
Above 40 KW up to 60 KW
PART-C: LT AND HT SWITCHGEAR MAINTENANCE
Round the clock maintenance and Routine & Preventive maintenance work of HT, LT switchgear, PMCC, MCC, PCC modules, local control panels, AC DBs, DCDBs, HVAC panels and including DC motor panels of main plant and offsite BOP area
Breakdown maintenance of HT breakers switchgear boards (11KV & 3.3 KV) & HT Bus Bars
Breakdown maintenance LT breakers, Modules PMCC/MCC /PCC/DC Control Panels and Power & control bus bars of LT panels
Routine, preventive &breakdown maintenance of all EOT cranes, Hoists &winches of TG & BOP areas
Testing Engineer
Highly Skilled manpower deployment for unscheduled jobs
Skilled manpower deployment for unscheduled Jobs
Semi- Skilled manpower deployment for unscheduled jobs
PART-D: MAINTENANCE OF TRANSFORMER & its equipments
Routine Check of various ratings power transformers Up to 40 MVA
Preventive Maintenance of various rating power transformer up to 40 MVA
Breakdown Maintenance of various rating power transformer up to 40 MVA
Oil filtration of transformers rating up to 40MVA
Bushing Replacement of Transformer up to 40 MVA
PART-E: MAINTENANCE OF DC SYSTEM AND DG SETS
Routine and Preventive maintenance of DG set AMF panels,220V DC battery banks &Chargers installed at Main Plant & BOP areas
PART-F: MAINTENANCE OF ESP& ASSOCIATED EQUIPMENTS
Arresting of oil leakage from high voltage rectifier Transformer
Checking, Cleaning and inspection of ESP area electrical equipments
Annual Preventive & Break-down maintenance of ESP fields/Tr panels
Annual Preventive & breakdown maintenance of ESP rectifier transformers
Oil filtration of Rectifier Transformer of ESP
Cleaning and Inspection of High Voltage rectifier Transformer
Deployment of highly skilled manpower for unscheduled jobs
Skilled manpower deployment for unscheduled jobs
Semi-Skilled manpower deployment for unscheduled jobs
Replacement of damaged with New/repaired ESP transformer along with negative bushing chamber by dismantling, lowering down, shifting, lifting up & recommissioning and associated works and connecting it to field
PART-G: MAINTENANCE OF GENERATOR AND AUXILLIARIES
Assistance in Daily checking of Generator parameters Upkeep and routine maintenance of various panels of Generator & its auxiliaries including IP,SP,NSPBD, Air pressurization units, PT cubicles, CT & PT, Marshalling boxes, ECUP
Transportation/Loading/Unloading of H2 gas filling
Servicing / Overhauling/Replacement of AC/DC seal oil pump or float trap valve of seal oil system as per Scope of work
Servicing / Replacement of valves of H2 Gas/Seal Oil System / Primary Water System Valve as per scope of work
Removal/ Filling of H2 gas from Generator as per scope of work
Alignment of Primary Water/seal oil pumps with AC/DC motor as per standard procedure.
Replacement of Bearing/ Mechanical seal of seal oil pump by isolating & dismantling and assembling & installation after completion of work
Servicing /Overhauling/Bearing replacement of Primary Water Pump
Replacement/Cleaning of seal oil system duplex Filter
Replacement/Cleaning of SWCS cooler Filter
Replacement of Resins
Servicing of Duplex filter of seal oil system as per scope of work
Attending Leakage from Generator gas coolers Coolers as per scope of work
Replacement of defective generator hydrogen gas Cooler
Detecting Hydrogen gas leakage with help of soap solution and attending minor gas leakage from entire generator system
Breakdown maintenance of thyristor cooling fans
Replacement of rubber expansion bellows of phase and neutral side of generator terminal/phase
Work on IP/NSPBD/SP bus ducts of UT/UAT/GT
Cleaning/replacement of flexible links of phase/neutral side of generator terminal as per scope of work
Replacement of phase/neutral side protection CT
Deployment of highly skilled manpower for unscheduled jobs
Deployment of skilled manpower for unscheduled Jobs
Deployment of semi-skilled manpower for unscheduled jobs
OEM based Services as per scope of work
PART H: Operation and maintenance of 765 kV/400 kV/220kV GIS & AIS Switchyards and Transformers/ICTs/Reactors above 63 MVA/MVAR
Routine and Breakdown maintenance of 765 KV AIS/400 KV GIS switchyard and GTs/ICTs/Reactors above 63 MVA/MVAR.
Shift duty of operating personnel in 3 shifts in a day of 765KV AIS/400 KV GIS Switchyard of JAWAHARPUR TPS.
PART I: Engagement of Electrical Field Operation Assistant (Operator) Round the clock in Shift for TWO years
2 nos. Shift Operator for Operation of Main Plant MV, LV Switchgear, MCC rooms and DC battery rooms.
2 nos. Shift Operator for Operation of MV, LV Switchgear, MCC room of ESP & FGD
2 nos . Shift Operator for Operation of LV Switchgear, MCC room of W& WWTP
2 Nos. Shift Operator for Operation of MV, LV Switchgear, MCC room of AHP
M/s Simar Infrastructures Limited
YASHMUN ENGINEERS LIMITED
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf