Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | ₹5.3 L Quoted ₹6.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹6.6 L+₹63,195 (10.6%)Rejected-Finance | ₹6.6 L+₹63,195 (10.6%) | L2 | Rejected-Finance Second lowest bidder |
Tender Value
₹4.6 L
EMD Value
₹9,200
Closing Date
11 Aug 2021, 5:00 pmClosed
Executive Engineer
HPSIDC Ltd. Shimla
Providing Electrical Installation in Veterinary Hospital
2021_SIDC_50777_1
Job No. 9
Open Tender
Electrical Works
Item Rate
120 days
Gokhra (Mandi)
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹9,200
11 Nov 2021
4 Aug 2021
12 Aug 2021
4 Aug 2021
11 Aug 2021
4 Aug 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and as per direction of the Engineer-in-charge.. Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and as per direction of the Engineer-in-charge.. Group C.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required and as per direction of the Engineer-in-charge.. (i) 2x1.5 Sq. mm.
2x2.5 Sq. mm.
4 x 4+2 x 4 Sqmm
2x4.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required and as per direction of the Engineer-in-charge..
Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required and as per direction of the Engineer-in-charge..
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required and as per direction of the Engineer-in-charge.. 2 Pair
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required and as per direction of the Engineer-in-charge.(i) 20 mm. dia
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required and as per direction of the Engineer-in-charge.:-(i) 2 modules (78mmx78mmx50mm)
6 modules(205mmx78mmx50mm)
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Telephone socket outlet, Modular.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required and as per direction of the Engineer-in-charge..
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required and as per direction of the Engineer-in-charge..
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required and as per direction of the Engineer-in-charge..
supplying and fixing Modular computer board on surface/recess with suitable size inner and outer sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, modular type switch,3 Nos. 5/6 Amp Switch and 3 Nos. 5 pin 5/6 Amp Socket complete connections, painting etc. as required and as per direction of the Engineer-in-charge..
Supplying and fixing bakelite batten /angle holder including connections, etc. as requied and as per direction of the Engineer-in-charge..
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required and as per direction of the Engineer-in-charge.
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required and as per direction of the Engineer-in-charge.
Supplying and fixing copper strip bus-bars suitable for 63 Amp/100. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required and as per direction of the Engineer-in-charge.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required and as per direction of the Engineer-in-charge. Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, /MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge.. 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge.. 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge.. (i) 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required and as per direction of the Engineer-in-charge.(i) Double door-12 way
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 8 module incomer, 2module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-2+8 way (8+6+24),horizontal type
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required and as per direction of the Engineer-in-charge..
Extra for using salt and charcoal for pipe earth electrode complete as required and as per direction of the Engineer-in-charge..
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required and as per direction of the Engineer-in-charge..
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- 25 Liter capacity water heater (Cat-A)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty, 300 mm sweep
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Heavy duty, 300 mm sweep in/c cost of fan Shutter required and as per direction of the Engineer-in-charge.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to required length] with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required and as per direction of the Engineer-in-charge. (i) Ceiling Fan 1200 mm sweep, Category-A
Ceiling Fan 1400 mm sweep, Category-A
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required as per direction and approve by the Engineer-in-charge. Fixed type wall bracket 150 dia, single lamp.(Category-A)
Mirror light 610 mm, double lamp.(Category-A)
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Bulk head fitting, CFL type (Category-A)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size and as per direction of the Engineer-in-charge.(i) Armoured cable 35 sq. mm (3.5 core)
(ii) Armoured cable 6 sq. mm (twin core)
(iii) Armoured cable 10 sq. mm (twin core)
Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Syska/Havells/Philips/ Bajaj make as required complete in all respect and approved & directed by engineer in charge.. 9 Watt
Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Syska/Havells/Philips/ Bajaj make as required complete in all respect and approved & directed by engineer in charge. (a) 15W
Supplying & fixing SKYLUKS LED surface mounting fitting 1' x 1' LED luminaire panel of Bajaj/Havells/Philips/Syska20 / 24WH as per direction and approve by the Engineer-in-charge
Providing & fixing Skyluks efficient LED panel recessed/surface 4x1 /2x2FTof Bajaj /Syska equivalent to Bajaj Code No. BZRSLL 36W GJI WH /NW complete in all respect fitting in ceiling as approved & directed by engineer in charge.
Supply, installation, testing & commissioning of 1.5 TR(cold) split type air conditioning unit with remote of following make complete as required in all respect with Base Frame , Refrigent copper piping , Hard PVC /Flexible drain pipe, PVC Round Cover 50mm dia upto required length including stabilizer & stand for AC as approved & directed by engineer in charge.in/c modular industrial socketwith MCB of required rating..Voltas/Lloyd/LG/Blue Star
Providing and fixing LEDstreet light fitting in warm white colour with pressure die- cast housing with toughened glass and individual LED's with secondary optics and IP 66 protection. As per CAT No. BRTFG 45W LED/W/W (warm White) complete in all respect. The fitting is to be fixed on existing bracket mounted on pole/on wall including wiring etc as required as approved and directed by engineer-in-charge of Bajaj/Philips/Havells make.
Providing and fixing 5mtr octagnol pole dip galvinised single dip to average 65 micron DFT and designed for wind speed of 169 KM/ hour Bajaj make pole top dia 70mm bottom dia 130mm and thickness 3mm with foundation bolt single arm bracket complete in all respect of Bajaj make as per product code BOP-5030 or make i/c MCB. connector and connection from connector to fitting s approved by Engineer-in-charge.
Providing and fixing Fire extinguisher water CO2 9 Kg type-IS-15683 as approved by the Engineer-in-Charge.
Providing and fixing Fire extinguisher CO2 4.5 Kg type-IS-15683 as per direction and approve by the Engineer-in-charge
supplying and fixing of reputed make Light Emitting Diode of following rating as required.7-15 Watt. (phillips/ syska/or equivlent make as per direction and approve by the Engineer-in-charge
Bhanu Pratap
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .