Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.5 LAccepted-AOC | 1 | Accepted-AOC Lowest amount |
Tender Value
₹2.3 L
Closing Date
25 Feb 2022, 10:00 amClosed
AGM PLANNING
O/o GMT,BSNL, BALAN K NAIR ROAD,ASOKAPURAM
Rewinding HV coil of 160 KVA Dry type Transformer at TE Kalpetta under Calicut BA
2021_BSNL_99071_2
KL CLT-17/13(20)/6/2021-PLG CLT KRL/09 dated at CL
Open Tender
Electrical Works
Works
60 days
BSNL, CALICUT
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
AO(Cash), O/o GMT,BSNL
Exempted
13 Sept 2022
4 Feb 2022
26 Feb 2022
4 Feb 2022
25 Feb 2022
4 Feb 2022
Amount
Rewinding of 1 No. High Voltage Primary coil in the one limb of 160 KVA 11KV / 415 V resin cast dry type transformer with suitable size and rating super enamelled copper conductor as per the existing design and casting with resin cast insulation , dismantling the faulty HV coil from the limb along with its resin cast insulation, i/c transportation of faulty transformer from TE Kalpetta to the Transformer manufacturing / repairing company and back to TE Kalpetta after rewinding, loading, unloading, lifting and shifting etc, reassembling the transformer in the UPSS chamber at TE Kalpetta after removing the existing 250 KVA Transformer, rewiring of control wiring for heater and temperature sensor and alarm circuit etc., testing commissioning complete as reqd. ( Agency shall submit factory testing certificate after rewinding the transformer and shall give a warrenty of one year) ( Note:- rate quoted shall be after deducting the scrap value of burnt copper )
Transporting of one number 250 KVA dry type transformer from TE Kalpetta to TE Asokapuram, ( Approx 70 Km), reinstalling the same in the UPSS Chamber at TE Asokapuram, i/c lifting, loading, unloading shifting etc, i/c re wiring of temperature sensor and alarm control circuit and heater circuit, connecting all HT and LT bus bars, testing and commissioning etc complete as reqd.
Supplying and fixing Rubber gloves 15000 V rating with ISI mark in the substation room etc as reqd.
S/F of High Voltage HRC fuse of 16 A / 20A rating with 40kA breaking capacity suitable for 11 KV/12 KVHT Load Break Switch
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .