Loading…
Loading…
Tender Value
₹5.5 Cr
EMD Value
₹11.0 L
Closing Date
24 Sept 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
Note for Technical Eligibility Criteria: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Single Similar Work: Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or 1.1.1 Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA- SSDAC) or Automatic signalling.
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Provision of sliding boom, electrically operated lifting barriers at LC Gates in ERS- KTYM - KYJ section of Thiruvananthapuram division
TVC-SNT-SIG-26-27-12~SR
TVC-SNT-SIG-26-27-12
Open
Works - General
10 Months
Thiruvananthapuram, Kerala
₹0
₹11.0 L
24 Sept 2026
2 Sept 2026
10 Sept 2026
75 items across 1 schedule · ₹2,75,53,472.51 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 300.00 | 382.12 | 1,14,636 |
| 2 | Supply and Provision of indicative type Class D Surge Protection Device f o r 2 4 V DC/48V D C (spark g a p type), w i t h Potential Free contacts and installed as per the instructions o f t h e Engineer i n charge a t s i t e ( OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better m a k e ) . A ll o t h e r miscellaneous materials required for installation shall be supplied by the contractor. | Numbers | 12.00 | 6,328.8 | 75,945.6 |
| 3 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per the instructions of the Engineer in charge a t site (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other m i s c e l l a n e o u s m a t e r i a l s required for installation s h a l l b e s u p p l i e d b y the contractor. | Numbers | 12.00 | 6,830.72 | 81,968.64 |
| 4 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 120.00 | 1,707.55 | 2,04,906 |
| 5 | Supply of 8-Channel Earth Leakage Detector as per RDSO Specifications RDSO/SPN/256/2002 or latest | Numbers | 6.00 | 1,10,759.06 | 6,64,554.36 |
| 6 | Supply of SMR of capacity 230V AC/110V DC, 2 0 A a s p e r R D S O Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 3.00 | 58,730.08 | 1,76,190.24 |
| 7 | Supply of DC-DC Converter of Capacity 110V DC/24-40V, 10A as per RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 6.00 | 21,381.6 | 1,28,289.6 |
| 8 | Supply o f Low maintenance secondary cells o f t h e following capacities w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. e) S u p p l y o f Secondary c e l l s - 2V-300AH capacity | Numbers | 180.00 | 9,574 | 17,23,320 |
| 9 | Installation o f 8-Channel E a r t h Leakage Detector. T h i s includes transportation of materials t o Site location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including c o n n e c t i o n t o t h e B R C e a r t h . Also includescarrying out of pre-commission checklist. | Numbers | 3.00 | 11,320 | 33,960 |
| 10 | Supply of 24 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S- 63/2014 REV.4 | Metre | 10000.00 | 388.15 | 38,81,500 |
| 11 | S u p p l y o f 1 2 Cx1 .5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 39000.00 | 215.92 | 84,20,880 |
| 12 | " S u p p l y o f 2 x 2 5 s q m m P V C insulated Armoured, unscreened underground Railway Signalling Aluminium cable a s p e r I R S : S- 63/2014 REV.4" | Metre | 6000.00 | 93.01 | 5,58,060 |
| 13 | S u p p l y o f Polythene Insulated Polythene Sheathed armoured J e l l y Filled Telephone Cable with Poly-AL Moisture Barrier, 10 Pairs, 0.63 MM Conductor Diameter as per RDSOSpecification N o . IRS:TC-41/97 with amendment 1 or latest | Metre | 1000.00 | 123.9 | 1,23,900 |
| 14 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" a s p e r t h e i n s t r u c t i o n s o f Railway representative a t s i t e . ) as per drawing enclosed | Numbers | 412.00 | 262.65 | 1,08,211.8 |
| 15 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included i n this schedule) | Metre | 20000.00 | 64.1 | 12,82,000 |
| 16 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying o f cables i s n o t included i n this schedule.) | Metre | 600.00 | 79.51 | 47,706 |
| 17 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth o f 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 115.00 | 314.41 | 36,157.15 |
| 18 | Breaking of Platform concrete having 0.3 feet thickness - 0.5 feet thickness and to a width of 0.3 Mtr using cutter machine and removal o f R C C s l a b s o n t h e Passenger Platform, t r e n c h i n g t o a d e p t h o f 0 . 6 m to a c c o m m o d a t e t h e a d d i t i o n a l cables, replacing the slabs removed after the cables a r e l a i d a n d replastering w i t h cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 15.00 | 2,224.44 | 33,366.6 |
| 19 | Excavation of trench along route of existing c a b l e d u c t , o p e n i n g t h e s l a b s to a c c o m m o d a t e a d d i t i o n a l c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables i s n o t included i n t h i s schedule.) [Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 150.00 | 161.92 | 24,288 |
| 20 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating i t a s per the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation o f trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth o f 1 m trench shall be from the bottom of sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 240.00 | 385.45 | 92,508 |
| 21 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench b y r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f D W C / R C C p i p e s with couplers/collars is not included in this schedule). | Metre | 282.00 | 501.03 | 1,41,290.46 |
| 22 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 300.00 | 208.54 | 62,562 |
| 23 | Provision o f G I p i p e s (50/100mm d i a ) for cable laying in hard rocky area with off sets a t b o t h e n d s d u l y supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes s h a l l b e c l o s e d w i t h b r i c k masonry abutments work so that no cable is exposed, T h e w ork shall be carried o u t a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 120.00 | 182.87 | 21,944.4 |
| 24 | L a y i n g o f signaling/power/ telecommunication cables a s per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre | 56000.00 | 18.18 | 10,18,080 |
| 25 | Placing of one layer of country bricks of size approximately 220mm x 100mm x 60mm lengthwise vertically in the trench.[Country bricks of size 220mm x 100mm x 60mm (approximately) shall be supplied by the Contractor]. | Metre | 600.00 | 30.53 | 18,318 |
| 26 | Placing of one row of country bricks of size approximately 220mm x 100mm x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 20000.00 | 62.99 | 12,59,800 |
| 27 | Placing of two rows of country bricks of size approximately 220mm x 100mm x 60mm breadth wise horizontally above thecables in 0.5mtr width trench.[Country bricks of size 220mm x 100mm x 60mm (approximately) shall be supplied by the Contractor]. | Metre | 600.00 | 116.41 | 69,846 |
| 28 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 20000.00 | 15.4 | 3,08,000 |
| 29 | "Refilling of cable trench 1m depth by 0.5m width throughout, with earth after laying of cables, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 600.00 | 19.29 | 11,574 |
| 30 | "Digging of pit to a depth of 800mm of size 3 0 0 m m X 3 0 0 m m , c a s t i n g o f concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y ramming. T h e cable markers shall be provided at an interval of 20 M t r s . w i t h i n statio n l i m i t s a n d 5 0 Mtrs. outside station limits throughout t h e cable r o u t e , d i v e r s i o n s a n d a l s o a t every track/road crossing." | Numbers | 412.00 | 123.35 | 50,820.2 |
| 31 | " Ro a d crossing/ Tr a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: T h e pilot used for HDD should be of sufficient size to s u i t insertion o f H D P E / D W C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a HDP E pipe o r a n y other combination a s d i r e c t e d b y t h e site engineer) ( S u p p l y o f H D P E p i p e i s not covered in this schedule)" | Metre | 260.00 | 1,351.45 | 3,51,377 |
| 32 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 15.00 | 8,850 | 1,32,750 |
| 33 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 15.00 | 9,233.5 | 1,38,502.5 |
| 34 | Supply o f KLCR relays 24V, A C I (Supply of Ke y Loc k Checking Relay (KLCR) w ith one number K-50 neutral Relay to work on 24V D C n o n A C immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt-1 or latest (with one extra ward plate andwith case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers | 48.00 | 10,722.72 | 5,14,690.56 |
| 35 | Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 237.00 | 4,366.63 | 10,34,891.31 |
| 36 | Supply of Relay, AC Immune, plug-in-type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers | 60.00 | 4,639.03 | 2,78,341.8 |
| 37 | Supply of electronic time delay units (120/60 s e c s ) w i t h p l u g boards, connectors and retaining clips with necessary inspection as p e r specificatio n/ d r a w i n g / description enclosed in this document. | Numbers | 104.00 | 2,742.03 | 2,85,171.12 |
| 38 | Supply of lamp proving relays(QECX-61) for a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 48.00 | 5,901.5 | 2,83,272 |
| 39 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 4.00 | 4,945.51 | 19,782.04 |
| 40 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 3.00 | 8,786.26 | 26,358.78 |
| 41 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set | 1.00 | 11,355.02 | 11,355.02 |
| 42 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ L C control circuit (up to 20 relays/Plug in type) | Set | 13.00 | 13,597.41 | 1,76,766.33 |
| 43 | Supply of relay rack to hold 168 relays, with necessary inspection, a s per specification/drawing | Numbers | 4.00 | 40,700 | 1,62,800 |
| 44 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm w ith Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rac k shall be covered with phynolic s h e e t o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w o r k also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T F u s e b l o c k s i s not covered in the schedule) [Wire P V C 3 / 0 . 7 5 m m copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint a n d a l l o t h e r miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 320.00 | 167.99 | 53,756.8 |
| 45 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm w ith Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rac k shall be covered with phynolic s h e e t o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w o r k also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T F u s e b l o c k s i s not covered in the schedule) [Wire P V C 3 / 0 . 7 5 m m copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint a n d a l l o t h e r miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 35.00 | 201.27 | 7,044.45 |
| 46 | Concreting a n d erection o f Re l a y racks- 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply of relay rack is not covered in this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, paint a n d all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d b y the Contractor]. b)Concreting a n d erection of relay rack - 56 capacity | Numbers | 12.00 | 3,015.04 | 36,180.48 |
| 47 | Fixing of plug boards, 50 way terminal blocks with 2BA terminals, and wiring of relays as per the approved circuit diagram using wire P V C 1 6 / 0 . 2 m m c o p p e r . Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide s m o o t h materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring o f contacts f o r data logger a n d terminating t h e m i n t a g blocks, provision of relay index board.(Supply of relays, plug boards, connectors and retaining clips i s not covered i n this schedule). [Wire P V C 16/0.2mm c o p p e r , t a g blocks, 2BA terminals, hard wood plank of size 600mmx 900mmx25mm w i t h decolum finish, MS angles o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, p h y n o l i c sheet 6mm t h i c k o f size 1200mmX1800mm with aluminium grooved channel frame for relay index board, paints, soldering materials, bunching thread, wire w o u n d resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay | 180.00 | 1,045.76 | 1,88,236.8 |
| 48 | Fixing o f additional p l u g boards, 5 0 ways terminal b l o c k s a n d w i r i n g o f additional relays a s p e r t h e approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC s h a l l b e p r o v i d e d w h e r e v e r required. Alterations t o Re l a y particulars s h a l l be incorporated in the relay Index board. (Supply o f relays, plug boards, connectors a n d retaining c l i p s a n d 5 0 w a y terminal boards is not covered in this schedule).[Wire P V C 16/0.2mm c o p p e r , 2 BA terminals, t e a k w o o d p l a n k 2 5 m m t h i c k for fixing r e s i s t o r s a n d c o n d e n s e r s , soldering materials, bunching t h r e a d , w i r e wound resistance, condenser, wire supporting tray w i t h cover o f suitable s i z e m a d e o f PVC, p a i n t , v a r n i s h a n d a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay | 140.00 | 726.5 | 1,01,710 |
| 49 | Carrying o u t alterations t o t h e existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire P V C 16/0.2mm copper. T h e w o r k includes p a i n t i n g alterations a n d r e l e a s i n g the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm c o p p e r , soldering materials, bunching t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay | 120.00 | 695.67 | 83,480.4 |
| 50 | Supply o f Double walled corrugated pipe - 103.5mm i n n e r d i a & 1 2 0 m m o u t e r dia c o n f o r m i n g t o s p e c i fi c a t i o n N o . IS 14930(Part 2 ) : 2 0 0 1 w i t h o n e coupler for e v e r y 6 m o f p i p e a s p e r Technical specification | Metre | 522.00 | 365.19 | 1,90,629.18 |
| 51 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 42.00 | 457.88 | 19,230.96 |
| 52 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 420.00 | 1,119.16 | 4,70,047.2 |
| 53 | Supply o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s p e r specification N o . I S 4984: 2016 with latest amendments a n d Material Grade:PE 80 | Metre | 260.00 | 853.55 | 2,21,923 |
| 54 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 3200.00 | 61.44 | 1,96,608 |
| 55 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 600.00 | 93.02 | 55,812 |
| 56 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 235.00 | 103.84 | 24,402.4 |
| 57 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 235.00 | 37.74 | 8,868.9 |
| 58 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 15.00 | 9,213.28 | 1,38,199.2 |
| 59 | "Erection o f s u r f a c e b a s e , s i g n a l pole, mounting o f c o l o u r l i g h t s i g n a l u p t o 4 aspects complete o n S i g n a l p o l e / Off-set bracket, ( f o r L E D / fi l a m e n t b u l b s ) with lenses, t r i p l e p o l e l a m p holde r, filament switching u n i t s , C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h p l a t f o r m c o m p l e t e and concreting o f ladder shoe, fixing o f number plates, marker board, lens guard, fixing of s p e e d l i m i t b o a r d w h e r e v e r necessary, termination o f tail cables, wiring o f signal u n i t w i t h P V C w i r e 3 / 0 . 7 5 m m copper, provision of EWS locks, and painting of one c o a t o f r e d o x i d e a n d t w o c o a t s of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall b e provided by drilling a hole i n t h e signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, l a m p holders, l a m p s , filam e nt switching u n i t a n d CLS transformer is not covered in this schedule). ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia , M sand, S i g n a l C o l l a r R i n g s , w i r e P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, l e a d w o o l , p a i n t s P V C / N y l o n sleeves, enameled number plates. enameled marker b o a r d s , E W S l o c k s , a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 15.00 | 8,287.08 | 1,24,306.2 |
| 60 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation a n d erection o f apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers | 13.00 | 11,333.1 | 1,47,330.3 |
| 61 | " E x c a v a t i o n o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' t y p e l o c k f o r t h e f r o n t d o o r and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]""" | Numbers | 17.00 | 8,787.04 | 1,49,379.68 |
| 62 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for e a c h p i p e f o r c a b l e throughing, fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside w ith o n e coa t of red-oxide and two coats of aluminium paints. (Supply o f C T boxes i s n o t covered i n this schedule. Rails o f different length shall be supplied b y Railways. T h e contractor shall cut lengthy rails wherever required.) [ C e m e n t , M s a n d , s t o n e j e l l y o f size 20/25mm, paint, varnish, GI Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for e a c h p i p e , fi x i n g b o l t s a n d n u t s with washers, E W S locks, paints a n d a l l other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 2.00 | 4,999.16 | 9,998.32 |
| 63 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination racks a s p e r approved circuit diagram. The terminal particulars a r e to be r e p a i n t e d /correc te d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k includes c l o s i n g t h e opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases w i t h masonry brick work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination racks w i t h cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 400.00 | 73.59 | 29,436 |
| 64 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." a)Termination o n 25/60mm P B T terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 2680.00 | 172.14 | 4,61,335.2 |
| 65 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." b)Termination o n P B T f u s e b l o c k (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 200.00 | 209.93 | 41,986 |
| 66 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also o n the inner side o f t h e doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. a)Termination o f cables o n 2 5 / 6 0 m m PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 380.00 | 151.09 | 57,414.2 |
| 67 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also o n the inner side o f t h e doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. b)Termination o f cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 35.00 | 188.86 | 6,610.1 |
| 68 | Charging and installation o f secondary cells o f t h e following capacities, o n existing battery stand/ RCC slabs in the battery room. T h e w o r k involves charging of secondary cells, fi x i n g a n d connecting the batteries with strips, manufacture and fixing of t e a k w o o d t e r m i n a l b o x , termination of c a b l e s , w i r i n g w i t h s u i t a b l e w i r e PVC 7/1.40mm a n d 3/0.75mm c o p p e r through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame in the relay room. The particulars shall b e digitally using good quality "laminated gum sheet, provision of hydrometer -1 No. on a stand and battery tester-1 No. Charging of secondary cells shall b e d o n e b y the contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). [Teakwood plank 25mm thick for manufacturing termination box with locking facility, w i r e P V C 7/1.4mm a n d 3/0.75mm copper, anti-corrosive paint, varnish, PVC pipes/ casing, a n d a l l other miscellaneous materials required f o r t h i s w o r k s h a l l be supplied by the contractor]." a) Installation o f 2 V- 3 0 0 A H c e l l o n existing stand / slabs(Per Unit = Per Cell) | Per Unit | 180.00 | 1,077.53 | 1,93,955.4 |
| 69 | Releasing of hand plunger lock single/double along with switch extension pieces, stretcher bars, point/ trap indicators and other fixtures carefully without damaging t h e materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Set | 20.00 | 2,389.28 | 47,785.6 |
| 70 | Releasing o f existing apparatus cases (Full/ H a l f / Quarter s i z e ) without d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, ' E ' t y p e l o c k s , e t c . , and breaking t h e c o n c r e t e foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. T h e released materials shall b e accounted a n d stacked a t a p l a c e a s instructed by Railway representative at site. | Numbers | 18.00 | 3,006.71 | 54,120.78 |
| 71 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with o r w i t h o u t R o u t e Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. T h e work includes breaking t h e concrete foundation,closing t h e resultant p i t and resurfacing it by ramming and levelling. | Numbers | 15.00 | 3,083.03 | 46,245.45 |
| 72 | Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. | Set | 20.00 | 5,550 | 1,11,000 |
| 73 | Releasing o f p o i n t r o d s w i t h r o d roller trestles, complete assembly. T h i s includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated by ramming and levelling. a)Releasing of trestles 1/2 way | Numbers | 340.00 | 86.3 | 29,342 |
| 74 | Releasing o f p o i n t r o d s w i t h r o d roller trestles, complete assembly. T h i s includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated by ramming and levelling. c)Releasing of point roddings | Metre | 400.00 | 14.71 | 5,884 |
| 75 | Releasing o f p o i n t r o d s w i t h r o d roller trestles, complete assembly. T h i s includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated by ramming and levelling. d) Releasing of A type foundations | Numbers | 80.00 | 632.15 | 50,572 |
| Schedule total | ₹2,75,53,472.51 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
GCCCorrectionslip1-5.pdf
ATTACHMENT
GCCCorrectionslip6-11.pdf
ATTACHMENT
SOR2022BOOKLET.pdf
ATTACHMENT
LetterPoliceVerification.pdf
ATTACHMENT
CableCutpenaltyLetter.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf Model form of Bank Guarantee
ATTACHMENT
ATC_4.pdf
ATTACHMENT
Annexure-B.pdf
ATTACHMENT
TANforELB.pdf
ATTACHMENT
EaratigTANver3_1.pdf
ATTACHMENT
KLCRDrawing.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .