| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC | ₹46.0 L Quoted ₹48.2 L | L1 | Accepted-AOC ANNAPURNA ENTERPRISES is the lowest bidder |
| 2 | L2₹49.9 L+₹1.7 L (3.52%)Rejected-Finance | ₹49.9 L+₹1.7 L (3.52%) | L2 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
| 3 | L3₹50.0 L+₹1.8 L (3.69%)Rejected-Finance | ₹50.0 L+₹1.8 L (3.69%) | L3 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
| 4 | L4₹51.0 L+₹2.8 L (5.71%)Rejected-Finance | ₹51.0 L+₹2.8 L (5.71%) | L4 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
| 5 | L5₹51.5 L+₹3.3 L (6.83%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | ₹51.5 L+₹3.3 L (6.83%) | L5 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
Tender Value
₹49.5 L
EMD Value
₹98,900
Closing Date
22 Jun 2024, 6:00 pmClosed
GE Kota
DADWARA KOTA RAJASTHAN 324002
REPAIR/ MAINTENANCE TO SUMMER APPLIANCES AND LT ELECTRIFICATION ALONGWITH CONNECTEED ITEMS AT SOUTHERN SECTOR AND ABHERA AREA AND COMPREHENSIVE MAINTENANCE OF STAND BY DG SETS UNDER GE KOTA AT MIL STN KOTA
2024_MES_657494_1
8819E8
Open Tender
Civil Works
Item Rate
183 days
GE Kota
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE Kota
₹98,900
Yes
26 Oct 2024
3 Jun 2024
29 Jun 2024
3 Jun 2024
22 Jun 2024
17 Jun 2024
Amount
REPAIR/ MAINTENANCE TO SUMMER APPLIANCES
M & L for taking down & refixing including transportation of window type AC upto 2 Ton capacity from site to civil workshop for repair to corroded body by replacing with 22 SWG MS sheet for side/top and 3mm thick MS plate in bottom of AC & including renewal of unserviceable spares and painting with anti corrosive paint of existing colour over and including a coat of suitable primer and return to MES store yard complete all as specified and directed.
M & L for taking down & refixing including transportation of split type AC indoor/outdoor unit upto 2 Ton capacity from site to civil/local workshop for repair to corroded body by replacing with 22 SWG MS sheet for side/top and bottom of AC & including renewal of unserviceable spares and painting with anti corrosive paint of existing colour over and including a coat of suitable primer and return to MES store yard complete all as specified and directed.
Attending complaints as on required of any nature for defective A/C of various capacity and make split /window type and rectification of defects & including necessary dismantling, taking down if required and taking out for repairing and refixing at site, replacing spares as required (spares parts shall be measured and paid separately), however small pieces of wire terminals, soldering/crimping required at site for proper functioning of the equipment shall deemed to be included in the quoted rate under this item complete all as specified and directed. Note : All spare parts for renewal/ fixing shall be measured and paid separately as supply only or supply & fixing under appropriate items of BOQ.
Supply only in renewal of starting capacitor 100/120/150 MFD suitable for window/split type AC complete all as specified and directed.
Supply only in renewal of running capacitor MFD/45+2.5 MFD/ 50+4.5 MFD / 60+6 MFD suitable for window/split type AC complete all as specified and directed.
Supply only in renewal of running capacitor 2.5/3/4/6 MFD for fan motor of window type/Split AC complete all as specified and directed.
Supply only in renewal of fan motor 1/5 HP long shaft suitable for window type AC of any capacity, as per sample complete all as specified and directed. MAKE: Universal / Sarada / Tibcon /Keltron
Supply only in renewal of fan motor 1/5 HP suitable for out door unit of split type AC 1.5 / 2.0 Ton capacity as per sample complete all as specified and directed. Make: Universal/Sarada/Tibcon/Keltron /American Universal/GE Motors.
Supply only in renewal of fan blade suitable for out door unit of split type AC 1.5/2.0 Ton capacity complete all as specified and directed. Make: Universal/Sarada/Tibcon/Keltron /American Universal/GE Motors.
Supply only in renewal of starting relay pin type for window / split type ACs as per existing specification complete all as specified and directed. Make - Renutral/ Indfos/ Annapurna or equivalent as approved by GE.
Supply only in renewal of printed circuit board (PCB) suitable for split type AC 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample.
Supply only in renewal of temperature digital display sensor suitable for split type AC 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample.
Supply and fixing in renewal of remote for A/C split type 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample.
Dismantling the unserviceable/damaged insulation and supply and fix nitrile rubber insulation of size 7/8" for suction and liquid refrigerant line for split type AC complete all as directed. Make-A-flex,Totaline.
Supply and fixing in renewal of copper tube 1/4" for window ACs of any capacity complete all as specified and directed. Make - Totaline/Carrier.
Supply and fixing in renewal of copper tube 1/2" complete all as specified and directed. Make - Totaline/Carrier.
Supply only in renewal of condensing coil with copper tube and aluminium fins of capacity 2.00 TR suitable for split AC complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply only in renewal of condensing coil with copper tube and aluminium fins of capacity 1.50 TR suitable for split AC complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply only in renewal of cooling coil with copper tube for indoor unit of split AC capacity 1.5/2.00 TR complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply and fixing in renewal of fiber body suitable for indoor unit of split AC 1.5/2.0 TR complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE.
Supply and fixing in renewal of factory made stand for outer unit of split AC as per existing specification and make complete all as directed.
M&L for electrically disconnecting of outdoor unit of split AC & including taking out from wall / stand after pumping down gas, cleaning/washing of chocked condensing fins and tubes with water and solvent materials by using mechinical pressure after cleaning and servicing refixing of unit, mechanically leak testing including filling of nitrogen gas for pressure testing, finding leak, vacuumising the gas and bracing of leaked copper pipes and filling the suitable refrigerant gas after complete testing, connecting the cables and testing for functioning complete all as specified and directed.
M&L for electrically disconnecting of window type AC and taking out from wall, cleaning /washing of choked condensing fins, evaporator coil and tubes with water and solvent materials by using mechinical pressure, renewal of unserviceable air filter after cleaning and servicing refixing the window AC, mechanically leak testing, including filling of nitrogen gas for pressure testing, finding leak, vacuumising the gas and bracing of leaked copper pipes and filling the suitable refrigerant gas after complete testing, connecting the cables and testing for functioning complete all as specified and directed.
Taking down unserviceable hermatically sealed compressor unit of window/split type ACs of 1.5/2.0 TR capacity and replace with new sealed compressor unit in exchange of the existing unserviceable sealed compressor unit with and including initial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas.
Blank
Taking down and re-fixing of window/split type AC including all accessories, making suitable size opening in existing wall as suitable for fixing of AC, including making good the disturbed surfaces to match with existing surface complete all as specified and directed.
Supply and filling refrigerant gas R-22/R- 32/R-410/R-134/R-600 for charging of gas in compressors of existing AC's/Refrigerator/water cooler/Deep freezer complete all as directed. Note ;- (i) Empty /filled cylinder shall be responsability of contractor and he shall be liable for all risk against same deemed to be included in the quoted rate. (ii) Empty gas Cylinders shall be returned to contractor after use.
M & L for repairs to voltage stabilizer of any make/model & including rewinding of main transformer, renewal of sensing transformer, connector, up to 30 Amps power relay and 3 core multistranded PVC insulated flexible copper conductor cable, voltage stabilizer of capacity upto 5 KVA complete all as specified and directed.
Attending complaints as on required basis of any nature for defective water coolers, refrigerator and deep freezer of various capacity and make and rectification of defects including necessary dismantling and taking out for repairing and refixing at site, replacing spares as required (spares shall be measured and paid separately), however small pieces of wire terminals, soldering / crimping required on site for proper functioning of the equipment will be deemed to be included in the quoted rate under this item. Note : All unserviceable spare parts for renewal/ fixing shall be measured and paid separately as supply only or supply & fixing under appropriate items of BOQ.
M&L for transportation of water cooler of any capacity form site to local workshop for repair to body by tinkering with 22 SWG MS sheet ,spray painting of complete water cooler with two coat of synthetic enamel paint over a coat of zinc primer on the repaired portion of existing colours, including supply and fix top cover beading, hinges, broken legs and transportation of water cooler back to AGE E&M yard capacity 40/80 ltr /60/120 ltr / 40/40ltr and testing commissioning complete. Note : All unserviceable spare parts for renewal/ fixing shall be measured and paid separately as supply only under appropriate items of BOQ.
Supply only in renewal of Fan motor 1/3 HP with blade complete all as directed. Make: AUE/Shreeram or equivalent make as approved by GE.
Supply only in renewal of relay for 1/3 HP compressor complete all as directed. Make: HI- Tech/Ranitrol.
Supply only in renewal of Over load proctector relay for 1/3 HP compressor complete all as directed. Make: HI- Tech/Ranitrol.
Supply only in renewal of Thermostatic switch for water cooler of any capacity complete all as directed. Make: Indofoss/Ranitrol.
Supply only in renewal of Starting Capacitor 40-60 MFD complete all as directed. Make: Keltron/Polycap.
Supply only in renewal of Running Capacitor 10 MFD complete all as directed. Make: Keltron/Polycap.
Supply only in renewal of 15mm bore statinless steel Push button Tap for water cooler as per sample complete all as directed. Make :- Jaison/Prayag/Sangam or equivalent make approved by GE.
Supply only in renewal of 15mm bore ball/float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 15mm-142gms) suitable for water coolers complete all as directed. Make:- Prayag/Sangam or equivalent make approved by GE.
Supply only in renewal of Plug top 15/16 Amps complete all as directed. Make :- Kinjal/Anchor/Havells or equivalent make approved by GE.
Supply only in renewal of Plug top 5/6 Amps complete all as directed. Make :- Kinjal/Anchor/Havells or equivalent make approved by GE.
Supply only in renewal of Cooling coil unit of Aluminium for freezer unit for 220 to 310 Litres complete all as directed. Make :- Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator.
Supply only in renewal of Cooling coil unit of Aluminium for freezer unit for upto 219 Litres complete all as directed. Make : Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator.
Supply only in renewal of Relay suitable for refrigerator of 1/6 or 1/8 HP compressor complete all as directed. Make :- Hi tech / Ranitrol.
Supply only in renewal of Capillary tube for refrigerator any capacity complete all as directed. Make :- Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator.
Supply only in renewal of Door lining (magnetic) for refrigerator 220/310 Litres capacity complete all as directed. Make :- Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator.
Supply only in renewal of Over load protector relay suitable for refrigerator complete all as directed. Make:- Hi tech/ Ranitrol.
Supply only in renewal of Cabin lamp for refrigerator as per sample complete all as directed. Make :- Philips/ Pigma/ Orsam.
Supply only in renewal of Thermostatic switch for Refrigerator complete all as directed. Make: Indofoss/Whirlpool (Auto defrosting type).
Taking down unserviceable compressor unit of water coolers of 40/80 ltr capacity and supply and fix with new sealed compressor & including intial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas.
Taking down unserviceable compressor unit of water coolers of 60/120 ltr capacity and supply and fix with new sealed compressor & including intial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas.
Supply and fixing sealed compressor 1/6 HP suitable for refrigerators & including taking down unserviceable existing compressor complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas.
Supply and fixing sealed compressor 1/8 HP suitable for refrigerators & including taking down unserviceable existing compressor complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 4 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor and including taking down old unserviceable wiring complete all as specified & as directed. Note :- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
Transportation of Deep freezer form AGE E/M store yard/site to local workshop for repair to body by tinkering with 22 SWG MS sheet, spray painting of complete deep freezer with two coat of synthetic enamel paint of existing colours over one coat of primer/red oxide, renewal of broken legs, hinges, complete top beeding, inside puff insulation and transportation of deep freezer back to AGE E/M yard capacity 300 ltr to 420 ltr and testing commissioning complete all as directed. Note : All unserviceable spare parts for renewal/ fixing shall be measured and paid separately as supply only or supply & fixing under appropriate items of BOQ.
Supply only in renewal of Relay for 1/3 Hp compressor (1208) complete all as directed. Make: HI- Tech/Ranitrol.
Supply only in renewal of Over load proctector relay for 1/3 HP compressor complete all as directed. Make: HI- Tech/Ranitrol.
Taking down unserviceable compressor unit of deep freezer upto 310 ltr capacity and supply and fix with new sealed compressor of capacity 1/3 HP unit of suitable capacity complete all as directed. Make:- Kirloskar/Blue star /Copeland.
Material and labour for spray painting of refrigerator / water cooler externally with two coats of Duco paint of approved shade after necessary preparation of surfces & including denting, etc. complete all as specified and directed for the following items: Refrigerator of capacity 300 / 310 Liters.
Refrigerator of capacity 165/185/200/220/230 Liters.
Water Cooler of capacity 60/120 Liters.
Water cooler of capacity 40/80 Liters.
Dismantling, opening and including rewinding the desert cooler fan motor of capacity 1/10 HP or 1/8 HP single phase AC 50 Hz with super enamelled copper wire of existing gauge/ size & including renewal of bush, shaft, packing gasket, nuts, bolts and washers, complete all as specified and directed.
Supply and fix in renewal of 20mm thick wool pad set (set of 3) & including wire mesh suitable for 18"/20" desert cooler complete all as specified and directed.
S&F in renewal of set of fan blades various type for derest coolers complete all as specified and directed.
Supply and fix in renewal of submersible 1.8m head, 5 ltr per minutes water discharge, 230 Volt, AC, Desert Cooler spray pump suitable for 18"/20" desert cooler complete all as specified and directed.
S&F in renewal of 3 core flexible FRLSH cable of multistranded copper conductor 2.5 sqmm confirming to latest IS, complete all as specified and directed.
S&F in renewal of regulating switch three speed 5 Amps, SP, 230 volts complete all as specified and directed.
S&F in renewal of PVC flexible pipe 15mm bore of superior quality complete all as specified and directed.
S&F in renewal of PVC water distributor 3 way assembly of size 15mm & including fixing at top of cooler by means of screw/ bolts /nuts, complete all as specified and directed.
M&L for preparation of steel surfaces of desert cooler (inner/ outer) & including spray painting with synthetic enamel paint first quality over & incl a coat of red oxide primer, complete all as specified and directed.
M & L for cutting of unserviceable rusted base from Water coolers of any make and S&F new base fabricated out of MS sheet 16 gauge on existing water cooler & including drilling and welding and applying two coats of synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed.
S&F in renewal of side panel made out of PBI sheet minimum 1mm thick suitable for 18''/20'' desert cooler and applying two coats of synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed.
Dismantling of unserviceable PVC/iron grill of desert cooler and Supply & fixing PVC/Iron grill suitable for 18''/20'' desert cooler including screws, nut & bolts etc, complete all as specified and directed.
Dismantling of unserviceable desert cooler fan motor with iron ring and supply and fixing of new fan motor copper wound, ISI marked with iron ring of existing capacity & including nuts, bolts, washers etc, complete all as specified and directed. Make :- Crompton/Khaitan/Usha/Polor.
S&F in renewal of single pole and neutral enclosure with a two pin and earth plug and socket, complete with one SP, MCB of 20 Amps, complete all as specified and directed.
M & L for disconnecting water cooler from existing position, drain out complete storage water and cleaning descaling etc., including repair of leakage, clean the surface of water cooler and refixing in original position, complete all as specified and directed.
Notes applicable for all above items :- (i) The contractor is required to carry out onsite (at the place of installation itself) repair of the summer appliances based on day to day requirement of MES during the currency of this contract. Therefore, while quoting the rates contractors should keep this factor in mind as the quoted rates shall deemed to be inclusive of the factor of onsite repair of various summer appliances. (ii) The repair/Maint of all the refrigerator having compact design shall be carried out by the auth rep of OEM only.
COMPREHENSIVE MAINTENANCE OF STAND BY DG SETS UNDER GE KOTA
Material and labour for servicing/overhauling and 'B' checks comprising of the following for generator lubrication system of under mentioned DG set engine and alternator & AC Generator: - (i) M&L for replacement of engine oil of 15W 40 conforming to CK 4 APL Category. (ii) M&L for replacement of lubricating oil filter elements (iii) M&L for renewal of super lube oil by pass filter elements (iv) M&L for cleaning/change crank case breather (v) M&L for checking of aneroid oil & cooling system. (b) Fuel System : M&L for renewal of fuel filter elements, oil change breather, throttle linkage, Air piping (c) Cooling System : M&L for renewal of coolant in radiator, check heat exchanger, nuts/bolts, adjust injectors and valves, M&L for renewal of tappet cover gasket. (d) AC Generator : Check of winding condition, oiling and greasing of bearings, tuning of exciters, rotating AVR function. Renewal of unserviceable bushes & including assembling and testing complete all as directed. Note : (i) The servicing/overhauling & 'B' checks of DG Set shall be carried out through the original equipment manufacturer's authorised dealers or their Auth service centers only.
500 KVA Capacity Make : Engine : CROMPTON GREAVES Alternator : CROMPTON GREAVES
250 KVA Capacity Make : Engine : CROMPTON GREAVES Alternator : CROMPTON GREAVES
180 KVA Capacity Make : Engine : KIRLOSKAR Alternator : Jyothi
160 KVA Capacity Make : Engine : Ashok Layland/Kirloskar Alternator : Kirloskar/Jyothi
125 KVA Capacity Make : Engine : Kirloskar Alternator : Jyothi
40 KVA to 82.5 KVA Capacity Make : Engine : Kirloskar Alternator : Jyothi
15 KVA to 25 KVA Capacity Make : Engine : Ashok Leyland/Kirloskar Alternator : Kirloskar/Jyothi
M & L for replacement of coolant additive concentrator confirming to CK 4 API category complete all as specified and directed.
Supply & fixing in renewal of water hose pipe of DG sets of capacities 500/ 250/ 180/ 160/ 125 KVA, complete all as specified and directed.
~ditto~ all as per item No 76.00 (here-in-before) but for DG sets of capacity up to 75 KVA.
Supply & fixing in renewal of flexible fuel pipe of DG sets of 75 to 500 KVA capacity, complete all as specified and directed.
Supply & fixing in renewal of flexible fuel pipe of DG sets upto 75 KVA capacity, complete all as specified and directed.
M&L for painting the DG Set and DG Set panel by thoroughly cleaning with CTC etc & including preparing the surface and applying one coat of synthetic enamel paint of approved shade by spray painting for DG Sets and DG Set Panels & including writing the capacity & make of DG Set, with white paint complete all as specified and directed for the following capacities of DG sets: -
5 KVA to 20 KVA DG Sets
25 KVA to 50 KVA DG Sets
75 KVA to 180 KVA DG Sets
Supply & fixing in renewal of battery charging alternator belt complete all as specified and directed and suitable for followling capacities of DG sets: -
DG Set 125 KVA to 500 KVA
DG Set 25 KVA to 50 KVA
DG Set 5 KVA to 20 KVA
Supply & fixing in renewal of battery lead set, PVC insulated multisranded copper conductor of size 70sqmm and 1.25 mtr long each duly fixed with brass clamps, copper lugs complete all as specified and directed and suitable for followling capacities of DG sets: -
DG Set 125 KVA to 500 KVA
DG Set 25 KVA to 50 KVA
DG Set 5 KVA to 20 KVA
S&F in renewal of water temperature gauge including sensor and cable complete all as specified and directed.
Dismantling of radiator, taking it to work shop for overhauling & cleaning, descaling with acid, removal of leakage, welding brazing & refixing it duly repaired etc complete all as specified and directed for followling capacities of DG sets: -
DG Set 160 KVA to 500 KVA
DG Set 45 KVA to 125 KVA
DG Set upto 45 KVA
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning and next due date for tank cleaning for the following capacities of DG Sets: -
DG Set 125 KVA to 500 KVA
DG Set 40 KVA to 75 KVA
DG Set 5 KVA to 25 KVA
S&F in renewal of water pump of suitable capacity complete all as specified and directed for the following DG sets: -
125 KVA to 500 KVA
upto 75 KVA
M &L for repair / overhauling of self starter & including renewal of carbon brushes, bearing, bushes, rewinding of armature and field etc. and warnishing, complete all as specified and directed for the following capacity: -
DG Set 250 KVA to 500 KVA
DG Set 125 KVA to 180 KVA
DG Set 40 KVA to 75 KVA
DG Set 5 KVA to 25 KVA
M & L for repair the fuel injection pump (FIP) & injectors from DG set cap 7.5 KVA to 62.5 KVA and carry out servicing and calibration including renewal of injectors nozzles etc., and refitting the same for smooth and efficient functioning complete all as directed.
M & L for repair the fuel injection pump (FIP) & injectors from DG set cap 75 KVA to 260 KVA and carry out servicing and calibration including renewal of injectors nozzles etc., and refitting the same for smooth and efficient functioning complete all as directed.
M&L for tappet setting, including renewal of gaskets, springs etc complete all as specified and directed.
DG Set 125 KVA to 500 KVA
DG Set 5 KVA to 75 KVA
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 25x4 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old unserviceable earthing complete all as specified and directed. (Earth lead strip and GI protection pipe beyond 7.50 m shall be measured and paid separately).
Supply & fixed in renewal of four pole MCCB, 63 Amp, 16 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 100 Amp, 16 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 160 Amp, 36 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 200 Amp, 36 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
Supply & fixed in renewal of four pole MCCB, 250 Amp, 36 KA (Ics=Icu=100%) with adjustable thermal and fixed magnetic settings, 415 Volts, 50 Hz, conforming to relvent IS/IEC complete all as specified and directed.
S & F and connecting in renewal of 180 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S & F and connecting in renewal of 150 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S & F and connecting in renewal of 100/110 AH sealed lead acid battery 12 Volt into DG set with all necessary connections, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 400 amp, including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 200 amp including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 100/125 amp including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F four pole onload change over switch, 415 V, 63 amp including disconnecting and taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 63 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 100 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 150 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 200 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
S&F Power contactor, 400 Amps, 3 pole, 415 Volts AC with single phase solenoid & incl taking out unserviceable one, complete all as specified and directed.
Material and labour for renewal of defective DG set digital controller of DG set capacity 15 KVA to 500 KVA as per manufacturer, complete all as specified and directed.
Material and labour for taking shutdown and disconnecting cables from AMF panel and DG set of capacity 5 to 62.5 KVA and dismantle the spare parts of any make and type and disconnect the engine from the alternator and transport it to the workshop and conduct engine overhauling of DG set and replace all the unserviceable spare parts with the new one and reassembling of complete DG set and incl testing, commisioning complete all as specified and directed by OEM & Engineer-in-Charge. Note :- Cost of spare parts shall be measured and paid separately under relevant item of this BOQ here-in-after.
Supply only in renewal of following spare parts of existing make for DG set of 5KVA to 62.5 KVA capacity: - Nozzle
Piston Ring
Piston asy
Liner with O-Ring
Head Gasket
Fuel gasket
CR Bearing set
Inlet Valve
Exhaust Valve
Head repairing
Engine head assy
Engine oil seal
Valve seal
Valve spring
Valve guide
M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity & including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter & including testing complete all as specified and directed by OEM & Engineer-in-Charge. Note :- Cost of spare parts shall be measured and paid separately under relevant item of this BOQ here-in-after.
Supply only in renewal of following spare parts of existing make for automatic main failure (AMF) panel of any capacity : - CT's of range 62.5 KVA to 400 KVA
Relay of range 62.5 KVA to 400 KVA
Digital Voltmeter/Ammeter
Voltage monitoring relay (digital type)
Delay timer
LED indicator (R Y B)
Toggle switch
Dismantling of unserviceable self starter of capacity 24 volts from engine and S&F new one in existing position complete all as specified and directed.
Dismantling of unserviceable self starter of capacity 12 volts from engine and S&F new one in existing position complete all as specified and directed.
Dismantling of unserviceable Dynamo of capacity 12 volts from engine Supply and fix new one in existing position complete all as specified and directed.
Dismantling of unserviceable Dynamo of capacity 24 volts from engine Supply and fix new one in existing position complete all as specified and directed.
S&F in renewal of automatic voltage regulator (AVR) for DG set of capacity 180 to 500 KVA, complete all as specified and directed.
S&F in renewal of automatic voltage regulator (AVR) for DG set of capacity 125 to 160 KVA, complete all as specified and directed.
S&F in renewal of automatic voltage regulator (AVR) for DG set of capacity upto 75 KVA, complete all as specified and directed.
Supply only distilled water in and including PVC containers/bottles of 5 litre each, complete all as specified and directed.
S & F in renewal of fuel indication transparent plastic tube of any size as per existing complete all as directed.
M & L in renewal of broken acoustic enclosure door hinges with stainless steel hinges complete with nut, bolts etc as per site requirement of any type, cap & make as per existing complete all as directed.
M & L in renewal of brass battery terminal suitable for lead acid battery 12 Volt 40 AH to 12 Volt 180 AH complete all as directed.
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 2.0 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 400 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x250 mm, including connection with LT cable with appropriate lugs, complete all as specified and directed.
Labour only for attending day to day break down of DG Set of any size and capacity including complete inspection of DG set, first hand repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of DG set with vacuum cleaner complete all as directed. Notes :- (i) The maintenance cost of DG set shall be deemed to comprises of cost of labour employed for the purpose, T & P used and other petty items such as cotton waste, kerosene oil, grease, nut, bolts etc. (ii) Non attending the complaint within 8 Hrs @ Rs. 2000/- per day shall be recovered from the contractor. (iii) Keep the complaints pending after one day @ Rs. 4000/- per day shall be recovered from the contractor. (iv) The complaint shall be generated by telephonically/Verbally by concern JE E/M or Engineer-in-Charge. (v) Spares shall be measured and paid separately. (vi) Servicing shall be carried out by the authorised dealer of Manufacturer's i.e. OEM.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removing excavated material (soil) n exc. 50m distance and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L dry clean river sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
M&L for trenchless boring under road/hard standing & including making good as per the existing complete all as directed. Note :- GI pipe shall be measured and paid separately under respective item of this BOQ.
S&F in renewal of 50 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
S&F in renewal of 80 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade (ISI marked), laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 135.10 & 135.60 :- (i) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ. (ii) Rate deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. Cross Sectional area of cable 95 Sqmm 3.5 core
Cross Sectional area of cable 70 Sqmm 3.5 core
Cross Sectional area of cable 50 Sqmm 3.5 core
Cross Sectional area of cable 25 Sqmm 4 core
Cross Sectional area of cable 16 Sqmm 4 core
Cross Sectional area of cable 10 Sqmm 2 core
S&F in renewal of automatic battery charger 12 Volt, DC, 10 Amps suitable for 5 KVA to 160 KVA DG set batteries with complete wiring connection & including suitable size of 2 core service cable for supply complete all as specified and dircted.
S&F in renewal of automatic battery charger 24 Volt, DC, 10 Amps suitable for 180 KVA to 500 KVA DG set batteries with complete wiring connection & including suitable size of 2 core service cable for supply complete all as specified and dircted.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m.
Supply, transporting, erection and fixing steel tubular swaged pole, 9.00 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete & including taking down existing old unserviceable poles and complete all as specified and directed.
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 9.0 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting 100 mm wide reflective red strickers in 3 lines around the pole, complete all as specified and directed.
S&F in renewal of PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 4 line, complete all as specified and directed.
S&F in renewal of PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 3 line, complete all as specified and directed.
M & L for cutting of bushes and cleaning the area around the sub station & surface dressing n exc 15 cm deep & including two pole/four pole structures premises at southern sector and cutting the bushes, complete all as specified and directed.
S&F in renewal of aluminium lugs, properly crimping and taping different colours, complete all as specified and dircted for the following size of cables: - 185 Sqmm
S & F in renewal for MCCB, four pole, 415 Volts, 400 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 250 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 200 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 160 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 100 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 63 Amp, ultimate breaking capacity 10 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
Supply only electrical insulating tape roll of length 25 metre and width 20 mm having high performance strength and good adhesive characteristics, complete all as directed.
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 400 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including connection with LT cable with appropriate lugs, complete all as specified and directed.
S & F in renewal of service wire of size 6 Sqmm 2 core of aluminium conductor PVC sheathed, confirming to latest IS/IEC complete all as specified and directed.
S & F in renewal of service wire of size 4 Sqmm 2 core of aluminium conductor PVC sheathed,confirming to latest IS/IEC complete all as specified and directed.
Disconnection of power supply from existing LT Panel of any type, disconnection of earth strips, cutting of the foundation angles/channels, removing of the panel from the site, including MS iron form work for raising the height of the panel upto the height as directed by the Engineer-in-Charge, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine, re-installation of panel, including repair to foundation of panel, restoration of power supply, including necessary excavation & earth work required for taking out & re-fixing the incoming and out going cables etc, complete all specified and directed. Note :- The MS form work shall be included in the quoted rate.
Disconnection of electric connection from existing LT Panel/LT feeder pillars panel of any size, dressing of cable ends including repair of body of LT panel, repair/welding work of gates, hinges of the door including rewiring by copper conductor control cables of suitable size, renewal of burnt out aluminium lugs and fixing with new lugs, nuts bolts etc, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine & necessary welding work if required & including necessary excavation & earth work required for taking out & re-fixing the incoming and out going cables etc, complete all specified and directed.
M&L for straight through jointing kits heat shrikable type LT UG XLPE cable heavy duty armoured sheathed & including excavation in any type of soil/strata, taking out cable & making disturbed surface after relaying the cable making joints suitable for aluminium conductor of following size complete all as specified and directed :-
10 Sqmm to 16 Sqmm 4 core
25 Sqmm to 50 Sqmm 3.5 core
70 Sqmm to 120 Sqmm 3.5 core
150 Sqmm to 185 Sqmm 3.5 core
S.S ENTERPRISES
RAGHAV ENTERPRISES
SARDAR PATEL ENTERPRISES
Aditya Enterprises
M/S R.K. Builders & Developer
Ganesh Contruction
SINGH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .