| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹45.6 LAccepted-AOC | L-01 | Accepted-AOC Being lowest | |
| 2 | L-02₹49.4 L+₹2.4 L (5.07%)Rejected-Finance 2ND FLOOR SC ROAD SANTA PLAZA TEZPUR DISTT SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L-02 | Rejected-Finance Not being lowest | |
| 3 | L-03₹49.4 L+₹2.4 L (5.10%)Rejected-Finance C O MALAY DUTTA MADHYAPARA OPP DARRANG COLLEGE GIRLS HOSTEL P O TEZPUR DISTT SONITPUR ASSAM 784 001 | SONITPUR | ASSAM | 784001 | L-03 | Rejected-Finance Not being lowest | |
| 4 | L-04₹49.9 L+₹2.9 L (6.14%)Rejected-Finance | L-04 | Rejected-Finance Not being lowest | |
| 5 | L-05₹50.1 L+₹3.1 L (6.50%)Rejected-Finance NOT AVAILABLE | L-05 | Rejected-Finance Not being lowest |
Tender Value
₹45.6 L
EMD Value
₹91,300
Closing Date
3 Sept 2024, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Charali
Spl repair to Bldg No T 274 and provn of Trg store for 401 cover shed near bldg No P 213 Bicycle cum scooter stand near bldg No T 548 in various location at Misa Campunder GE S Tezpur
2024_MES_662825_1
8891
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹91,300
Yes
12 Nov 2024
28 Jun 2024
5 Sept 2024
28 Jun 2024
3 Sept 2024
13 Jul 2024
28 Jun 2024 - 3 Jul 2024
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth round, in layers not exceeding 25 cm in soft/loose soil and removing surplus soil to a distance in exc 50m and making good surface complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and as directed.
Excavation in trenches not exc. 1.5 Metre wide and exc. 1.50 Metre but not exc. 3.0 Metre or part there of in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Material (Soil) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L Plain Cement Concrete type B-1, (1:2:4) (20mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed.
M&L Hardcore of gauge not exc. 63 mm, broken stone aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface below plinth protection/hard standing/floor complete all as specified and as directed.
M&L Earth filling under floor or in foundations including watering and consolidation, spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed. Note- Additional earth if required shall be obtained from MOD land and rate of which shall deemed to be included in the quoted rate
M&L for 25mm thick damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, type B-0 using 12.5mm graded stone aggregate including necessary formwork complete all as specified and as directed.
M&L RCC M-25 Design Mix type B1 using 20 mm graded aggregate as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc; basement slabs, under reamed piles and mass concrete complete all as specified and as directed.
M&L RCC M-25 Design Mix type B1 using 20 mm graded aggregate) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L RCC M-25 Design Mix type B1 using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L RCC M-25 Design Mix type B1 using 20 mm graded aggregate as in slab, shelves etc.all as specified and directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M & L RCC M-25 Design Mix type B1 using 20 mm graded aggregate as in chajjas and the like all as specified and directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L for formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed.
M & L Formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified and directed.
M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified and directed.
M&L Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed.
M & L Formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed.
M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
Taking down chowkhats incl shutters (without taking off shutters from the frame exc 1.5 sqm but n. exc 4 sqm complete all as specified and as directed.
M&L Pressed steel frames for doors with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. Note :- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate
S&F 35 mm thick factory made flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specified and directed.
S&F 2nd class hardwood 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauge etc. divided into squares with plain chamfered or rounded, rebated sash bars, sizes of the members of the shutters as specified in SSR Part I, section 8, clause 8.23(a) complete all as specified and directed.
S&F 200 mm long,aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
M&L Extruded aluminium alloy handle fabricated type of 150 mm long complete all as specified and directed.
S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F for MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F Floor door stopper 14cm long of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in repairs in floor.complete all as specified and directed.
S&F as in repair stainless steel curtain rod of dia 38 mm with fixing brackets,etc. with two Nos of end knob complete for doors/window opening complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat ), removing serviceable tiles to store and rubbish off the premesises complete all as specified and directed.
M&L 18-20 mm thick machine cut kota stone slab (table rubbed and polished) as in flooring laid over and including 15 mm thick screed bed or bedding layer in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing, grinding and mirror polishing upto desired satisfaction of Engr In Charge complete all as specfied and directed.
M&L Machine cut kota stone slab 18-20 mm thick as in skirting,risers of steps laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing including rendering 10mm thick on brick wall or concrete surfaces in cement mortar 1:4 for fixing of tiles complete all as specified and directed.
M&L Chequrred cement concrete tile 25 cm x 25 cm x25 mm thick set jointed and pointed in neat cement slurry in floors, with grey cement and pigment including 15mm thick screed bed or bedding layer in cement mortar1:6 complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block glossy finished with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade over 40 mm sand cushion over rammed earth complete all as specified and as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed.
M&L Rendering 15mm thick on brick wall or concrete surface consisting two layers, under layer of 10mm thick in CM (1:4) & top layer of 5mm thick in cement mortar 1:4 mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. Note:- Water proofing compound shall be measured and paid saperately under relevant item
M&L Rendering 15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed.
Supply only Integral Water Proofing compound, conforming to IS 2645 and as approved, complete all as specified and directed.
M&L Cement Concrete type D2 (1:4:8) using 40mm graded aggregate 75mm thick in Sub-bases, finishing concrete surfaces fair and even, complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in path/pavings finished rough and laid in alternate bays to receive chequered tile complete all as specified and directed.
M & L 75mm th PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L 150 mm th PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in sub base of flooring complete all as specified and directed.
M&LForming Constrution (Dummy) joints 30 mm deep x 10 mm wide, filled with sealing compound grade A.complete all as specified and as directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or weldedy complete all as specified and directed by Engineer-in-Charge
S&F Steel window frame with side hung shutters including box type hinges with steel handle and steel pegs stay complete with glazing bars complete all as specified and directed.
S&F Steel ventilators with top hung shutters including hinges, steel peg stay, complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane including hacking out old broken glass any, size, quality or description from wooden / metal frame complete all as specified and directed.
S&F Sheet glass ordinary quality 4mm thick and glazing with oil putty in squares n.exc. 0 .5 sqm each pane complete all as specified and directed.
M&L Galvanised mild steel wire cloth of 0.56mm dia and average aperture of 1.18mm and fixed in position complete all as specified and directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering.complete all as specified and as directed.
S&F Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/clading to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed.
S&F Rolled mild steel sections as in main and cross beams,hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors,fixed with angle cleats or other connecting plates of Fe-410-W(Gde-E-250) quality-B complete all as specified and as directed.
S&F Rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction but welded tubes conforming to IS- 1161-1979 grade St-240 complete all as specified and directed.
M&L Mild steel screw bolts (machine made),diameter of neck 16 to 20 m,length of bolt exc 22.5cm and n exc 30cm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed.
Dismanting timber scantling under 40 Sqcm in secion In fillets, rails , posts, refters and purlins etc in any position in framed work or unframed work.complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L Aluminium powder coated snap grid False ceiling of size 600 mm x 600 mm x 4 mm thick for fixing boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements with 1.6mm dia GI wire and anodised adjuster complete all as specified and as directed.
M&L 6mm thick non asbestos fibre cement building board fixed/inserted to Aluminium frame work, as in ceiling complete all as specified and as directed.
M&L Preparing new Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 3mm thick water proof wall care putty by smart painting method including rubbing with emmery paper to make wall surface smooth and even by smart painting method complete all as specified and directed.
M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsion anti fungus Paint over a coat of Primer (as per Manufacturer’s instructions), and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Exterior Emulsion anti fungus Paint over a coat of damp shield Primer (as per Manufacturer’s instructions), and applied over 3mm thick water proof wall care putty by smart painting method including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L applying two coat of distemper by smart painting method on ceilling non asbestos fibre cement building board surfacescomplete all as specified and directed.
M&L Preparing new Steel or Iron Surfaces of any description, exe 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide, Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing new Wood and Wood Based Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed.
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as specified and as directed by Engineer-in-Charge.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall deemed to be included in the quoted rate.
All as per item No. 78 here-in-before but one 3 pin 5 amps switch socket out let on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No 78 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit 20mm dia medium duty with all accessories (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall deemed to be included in the quoted rate.
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including metal flush box suitable for modular cover plate with frame of size 1M to 8M for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall deemed to be included in the quoted rate. (iii) Metal flush box , modular cover plate with frame of size 1M to 8M shall be measured and separately under relevant item.
All as per item No. 82 here-in-before but one 3 pin 5 amps switch socket out let on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No.82 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit 20mm dia medium duty with all accessories (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point including metal flush box suitable for modular cover plate with frame of size 3M for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall deemed to be included in the quoted rate. (iii) Metal flush box , modular cover plate with frame of size 3M shall be measured and separately under relevant item.
S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular type switch 16 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular socket out let 3 pin 6 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular socket out let 3 pin 6/16 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and as directed.
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 5 pin 5 and 15 Amps, flush type universal, 240 Volts complete all as specified and directed.
S&F Ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F Lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified and directed.
S&F Stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 2 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 3 modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 4modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 6modules complete all as specified and as directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 8 modules complete all as specified and as directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 2 Module complete complete all as specified and as directed. .
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 3 Module complete complete all as specified and as directed. .
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 4 Module complete complete all as specified and as directed. .
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 6 Module complete complete all as specified and as directed. .
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 8 Module complete complete all as specified and as directed. .
Supply and fixing submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.
Supply and fixing Bldg security light fittings 30 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
Supply and fixing 18 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
S&F Recessed/surface dust free LED fitting 36 watts size(2X2)'' soft light glare free homogenous illumination very high efficiency enviormental friendly long life complete making all connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose as in repair complete all as specified and directed.
S&F in repair LED bulb 15W,6500k complete all as specified and directed.
Supply and fixing epoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
Supply and fixing for sheet metal enclosure TPN DB- 4 way 415 V, double door , 200 A copper bus bar, IP 43,Suitable for 63-125 Amp MCCB as incomer as flush mounted complete all as specified and as directed.
Supply and fixing MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessary connection complete all as specified and directed.
Supply and fixing MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed.
Supply and fixing MCB TPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F Ventilating metallic exhaust fan 380 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size complete all as specified and directed.
Taking down ceiling fans, exhaust fan of any sweep and any height and opening the fan and oiling,greasing and replacement of unserviceable accessories and servicing overhauling and reassembling and testing for efficient functioning and hanging back in position including provision of 0.50 sqmm copper flexible twin twisted cable of required length from ceiling rose to fan complete all as specified and directed.
Supply, laying / fixing / connecting, testing and commissioning of 10 Sqmm x 2 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified complete all as specified and as directed by the Engr-in-Charge. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor's firm name while carrying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
AVASANA SOLUTIONS PRIVATE LIMITED (BID ID -3067965)
M/S Jiban Krishan Das and Co (BID ID -3066970)
M/s MN ENTERPRISRE (BID ID -3068506)
MOHAMMAD NABI HUSSAIN (BID ID -3068923)
BCL (BID ID -3067993)
M/S MOHANPASARI (BID ID -3069119)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .