Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.5 LQualified Make: Sonel
Model: SONEL & MRU-120 204 CONVERGENT TECHNOLOGIES 2ND MAIN MAHALAKSHMI LAYOUT BANGALORE KARNATAKA 560086 | BENGALURU URBAN | KARNATAKA | 560086 | Make: Sonel
Model: SONEL & MRU-120 | L1 | Qualified | |
| 2 | L2₹2.7 L+₹27,524 (11.2%)Qualified Make: FLUKE
Model: Fluke 1623-2 1ST FLOOR RZ 100J 182 OPPOSITE PILLAR NO 34 NR PALAM METRO GATE NO 2 RAJ NAGAR I PALAM NEW DELHI SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | Make: FLUKE
Model: Fluke 1623-2 | L2 | Qualified | |
| 3 | L3₹3.2 L+₹74,604 (30.3%)Qualified Make: FLUKE
Model: Fluke 1623-2 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: FLUKE
Model: Fluke 1623-2 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Oct 2018, 4:00 pmClosed
Digital Earth Resistance Meter ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Display type 3½ digit LCD display 3½ digit LCD display Measurable Earth resistance range selection Auto ranging Auto ranging Method for resistance measurement 4-pole 4-pole Counts 2000 2000
3000
4000
6000
10000 Number of the stakes 4 * Material of the stakes Galvanised Iron * Length of the Stakes 30 * Diameter of the Stakes 10 * Number of the Test Leads 3 * Length of the Test Leads 50 * Number of Test Leads 2 * 1/4 with Clamps Length of Test Leads with Clamps 1 * OTHER FEATURES Internal Memory (Number of record) 1500 * External memory Through USB * Interface USB * Minimum Open Circuit Output voltage 48 * Over range indication Available * Stakeless test(Clamp On) true true
false MEASUREMENTS Number of Measurable Range 2 * Measurable Ranges (Ohm) 1 to 1999
0.01 to 19.99 * Measurable Earth resistance resolution (Ohm) 0.01
0.1 * Measurable Earth resistance accuracy ±2 % ±2 count
±2 % ±1 count * Facility to Measure Earth Voltage true * If Yes
Measurable Earth Voltage range 24 * If Yes
Measurable Earth Voltage accuracy 0 * If Yes
Measurable Earth Voltage resolution 0 * Other features to measure soil resistivity * GENERIC Weight of the tester 1.1 * Dimensions (cm x cm x cm) 250 mm x 133 mm x 187 mm * POWER REQUIREMENTS Type of Battery Non- Rechargeable (Alkaline) * if rechargeable
then chemistry of the battery NA * if Non-rechargeable
then size of the battery cell AA * Number of non- rechargeable the battery/cell 4 * 2/4 Voltage of rechargeable Battery 9 * Capacity of rechargeable battery (milliamperehour) 3000 * Suitable charger adaptor provided NA * Battery backup time 3000 * Low battery indication Available * ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the tester GEO Earth Ground Tester
User's Manual
Batteries
Quick Reference Guide
2 Test Leads
USB Cable
carrying case
earth stakes
reel cables
2 nos of clamps * TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hours at a temperature of 55 degree C in accordance with IS:9000/part-3/sec tion-5/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 latest true * conformity to Cold test at 0 degree C for four hours as per IS: 9000( Part 2/section 4) latest true * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove confromity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * 3/4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramavath Vijay Kumar 500062
HRPSU
NFC
P.O. ECIL
1 30
624275
GEM/2018/B/88625
digital earth resistance meter
30 days
Telangana; Medchal Malkajgiri
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Digital Earth Resistance Meter ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Display type 3½ digit LCD display 3½ digit LCD display Measurable Earth resistance range selection Auto ranging Auto ranging Method for resistance measurement 4-pole 4-pole Counts 2000 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 6000 | - | - | - |
| 10000 Number of the stakes 4 * Material of the stakes Galvanised Iron * Length of the Stakes 30 * Diameter of the Stakes 10 * Number of the Test Leads 3 * Length of the Test Leads 50 * Number of Test Leads 2 * 1/4 with Clamps Length of Test Leads with Clamps 1 * OTHER FEATURES Internal Memory (Number of record) 1500 * External memory Through USB * Interface USB * Minimum Open Circuit Output voltage 48 * Over range indication Available * Stakeless test(Clamp On) true true | - | - | - |
| false MEASUREMENTS Number of Measurable Range 2 * Measurable Ranges (Ohm) 1 to 1999 | - | - | - |
| 0.01 to 19.99 * Measurable Earth resistance resolution (Ohm) 0.01 | - | - | - |
| 0.1 * Measurable Earth resistance accuracy ±2 % ±2 count | - | - | - |
| ±2 % ±1 count * Facility to Measure Earth Voltage true * If Yes | - | - | - |
| Measurable Earth Voltage range 24 * If Yes | - | - | - |
| Measurable Earth Voltage accuracy 0 * If Yes | - | - | - |
| Measurable Earth Voltage resolution 0 * Other features to measure soil resistivity * GENERIC Weight of the tester 1.1 * Dimensions (cm x cm x cm) 250 mm x 133 mm x 187 mm * POWER REQUIREMENTS Type of Battery Non- Rechargeable (Alkaline) * if rechargeable | - | - | - |
| then chemistry of the battery NA * if Non-rechargeable | - | - | - |
| then size of the battery cell AA * Number of non- rechargeable the battery/cell 4 * 2/4 Voltage of rechargeable Battery 9 * Capacity of rechargeable battery (milliamperehour) 3000 * Suitable charger adaptor provided NA * Battery backup time 3000 * Low battery indication Available * ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the tester GEO Earth Ground Tester | - | - | - |
| User's Manual | - | - | - |
| Batteries | - | - | - |
| Quick Reference Guide | - | - | - |
| 2 Test Leads | - | - | - |
| USB Cable | - | - | - |
| carrying case | - | - | - |
| earth stakes | - | - | - |
| reel cables | - | - | - |
| 2 nos of clamps * TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hours at a temperature of 55 degree C in accordance with IS:9000/part-3/sec tion-5/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 latest true * conformity to Cold test at 0 degree C for four hours as per IS: 9000( Part 2/section 4) latest true * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove confromity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * 3/4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramavath Vijay Kumar 500062 | - | - | - |
| HRPSU | - | - | - |
| NFC | - | - | - |
| P.O. ECIL | - | - | - |
| 1 30 | - | - | - |
Exempted
4 Oct 2018
4 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_624275.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .