Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.8 L+₹2.9 L (11.7%)Rejected-Finance PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹28.4 L+₹3.5 L (14.1%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹28.4 L+₹3.5 L (14.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹31.0 L+₹6.1 L (24.6%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | m/s prakash enterprise L2 | SURESH ELECTRICALS L3 | AADESH CONSTRUCTION L5 | SANVI ASSOCIATES L1 | J J ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 0.00Schedule 'A' | ||||||||
| 1.00 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in hard/dense soil all as specified and directed | 100 | CUM | 675 ₹67,500 | 945 ₹94,500 | 800 ₹80,000 | 750 ₹75,000 | 350 ₹35,000 Lowest |
| 2.00 | Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed | 80 | CUM | 139 ₹11,120 | 259 ₹20,720 | 160 ₹12,800 | 125 ₹10,000 Lowest | 200 ₹16,000 |
| 3.00 | Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed. | 20 | CUM | 320 ₹6,400 | 448 ₹8,960 | 240 ₹4,800 | 200 ₹4,000 Lowest | 220 ₹4,400 |
| 4.00M&L for taking up old unserviceable ductile iron (DI) water mains including all fittings with spigot and socket joints/flanges, burning out lead joints from the existing location including cleaning complete all as specified and as directed for the following sizes :- | ||||||||
| 4.01 | (a) 80 mm dia | 100 | RM | 90 ₹9,000 | 50 ₹5,000 Lowest | 110 ₹11,000 | 85 ₹8,500 | 90 ₹9,000 |
| 4.02 | (b) 100 mm dia | 50 | RM | 105 ₹5,250 | 60 ₹3,000 Lowest | 120 ₹6,000 | 100 ₹5,000 | 95 ₹4,750 |
| 4.03 | (c) 150 mm dia | 30 | RM | 120 ₹3,600 | 70 ₹2,100 Lowest | 150 ₹4,500 | 110 ₹3,300 | 130 ₹3,900 |
| 5.00 | Supply and fix in replacement of butterfly valve 100/150 mm dia including all necessory fittings all as specified and directed. | 2 | Each | 10,050 ₹20,100 | 5,000 ₹10,000 Lowest | 15,000 ₹30,000 | 9,500 ₹19,000 | 15,000 ₹30,000 |
| 6.00Supply and fix in replacement of CI sluice valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :- | ||||||||
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 May 2026, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
REPAIR/ REPLACEMENT OF EXTERNAL WATER SUPPLY INSTALLATIONS, GI/CI/DI PIPE LINES, PUMPS, ELECTRIC MOTORS, VALVES AND CLEANING OF OVERHEAD TANKS AND UG SUMPS AND ALLIED WORKS AT NAVAL AIR ENCLAVE
2026_MES_762814_1
9359/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹50,000
Yes
28 Jul 2026
30 Apr 2026
23 May 2026
30 Apr 2026
22 May 2026
15 May 2026
30 Apr 2026 - 14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Schedule 'A' | - | - | - | - |
| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in hard/dense soil all as specified and directed | 100 | CUM | - | - |
| - | Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed | 80 | CUM | - | - |
| - | Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed. | 20 | CUM | - | - |
| - | M&L for taking up old unserviceable ductile iron (DI) water mains including all fittings with spigot and socket joints/flanges, burning out lead joints from the existing location including cleaning complete all as specified and as directed for the following sizes :- | - | - | - | - |
| - | (a) 80 mm dia | 100 | RM | - | - |
| - | (b) 100 mm dia | - | RM | - | - |
| - | (c) 150 mm dia | - | RM | - | - |
| - | Supply and fix in replacement of butterfly valve 100/150 mm dia including all necessory fittings all as specified and directed. | 2 | Each | - | - |
| - | Supply and fix in replacement of CI sluice valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :- | - | - | - | - |
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Gen_spec.pdf
Tender Documents • 1.81 MB
BOQ_854474.xls
BOQ • 16.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .