Loading…
Loading…
Tender Value
₹12.6 Cr
EMD Value
₹9.6 L
Closing Date
28 Aug 2026, 6:00 pm
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF HIGH SECURITY WALL WITH CONCERTINA COIL AND ENTRANCE GATE AT 19 WEU UNDER GE (N) TEZPUR
2026_MES_781318_1
98843_TEZ(N)_SZ_E8
Open Tender
Civil Works
Item Rate
360 days
TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (N) TEZPUR
₹9.6 L
Yes
31 Jul 2026
31 Jul 2026
4 Sept 2026
31 Jul 2026
28 Aug 2026
21 Aug 2026
31 Jul 2026 - 7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for dismantling old existing posts or struts (wood, steel or RCC), any section, including taking out embedded portion and making good disturbed ground embedded in concrete with and including clear vegatation on fencing and in floor area to facilatate demolition of any size and section complete all as specified and directed. | 1,282.5 | RM | - | - |
| 2 | M&L for dismantling fencing wire mesh any type complete all as specified and directed. | 5,670 | SQM | - | - |
| 3 | M&L for dismantling mild steel work such as gate of any description not otherwise provided for complete all as specified and directed. | 110.1 | QTL | - | - |
| 4 | M&L for dismantling mild steel work as in barbed wire of any description not otherwise provided for complete all as specified and directed. | 9.72 | QTL | - | - |
| 5 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. | 200 | RM | 2 | ₹400 |
| 6 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. | 2,535 | RM | - | - |
| 7 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3.5 core with reduced neutral conductors (3.5 core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. | 100 | RM | - | - |
| 8 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy Duty) with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 Volts grade complete all as specified and directed | 500 | RM | - | - |
| 9M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed by Engr-in-Charge. NOTE : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final. | |||||
| 10M&L for returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cm in depth complete all as specified and directed by Engr-in-Charge. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Complete_Drgs_CESZ 2018 TD-01 (Sheet No 1)Architectural norms general notes (fixing height of various fitting fixtures)..pdf
Additional Documents • 0.22 MB
Complete_Drgs_CESZ 2018 TD-01 (Sheet No 2) Architectural norms general notes (fixing height of various fitting fixtures).pdf
Additional Documents • 0.14 MB
Complete_Drgs_CESZ 2018 TD-01(Sheet No 3) Architectural norms general notes (fixing height of various fitting fixtures)..pdf
Additional Documents • 0.10 MB
Complete_Drgs_CESZ 2018 TD-27 (Sheet No 1) Details of MS Gate.pdf
Additional Documents • 0.11 MB
Complete_Drgs_CESZ 2018 TD-27 (Sheet No 2) Details of MS Gate.pdf
Additional Documents • 0.07 MB
Complete_Drgs_CESZ 2018 TD-27 (Sheet No 3) Details of MS Gate.pdf
Additional Documents • 0.06 MB
Complete_Drgs_ST-12 1-5 HIGH SECURITY WALL 3.0 M HIGH FOR BASIC WIND SPEED OF 50 MS .pdf
Additional Documents • 0.08 MB
Complete_Drgs_ST-12 2-5 HIGH SECURITY WALL 3.0 M HIGH FOR BASIC WIND SPEED OF 50 MS .pdf
Additional Documents • 0.09 MB
Complete_Drgs_ST-12 3-5 HIGH SECURITY WALL 3.0 M HIGH FOR BASIC WIND SPEED OF 50 MS .pdf
Additional Documents • 0.06 MB
Complete_Drgs_ST-12 4-5 HIGH SECURITY WALL 3.0 M HIGH FOR BASIC WIND SPEED OF 50 MS .pdf
Additional Documents • 0.09 MB
Complete_Drgs_ST-12 5-5 HIGH SECURITY WALL 3.0 M HIGH FOR BASIC WIND SPEED OF 50 MS .pdf
Additional Documents • 0.06 MB
Complete_Tender.pdf
Tender Documents • 4.46 MB
BOQ_875948.xls
BOQ • 1.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].