Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹986.4 Cr
EMD Value
₹9.9 Cr
Closing Date
16 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GM - Contract
Construction of 12.527 km Elevated Viaduct from Shilaj Circle to Badrabad Dead End, including 7 Nos. elevated Stations of Ahmedabad Metro Rail Project
351978
GMRC/CONS/STNS+VDCT - 2/2026
Open
Civil - All
Works
Gandhinagar
9 documents required · 8 mandatory · 1 optional
₹50,000
₹9.9 Cr
11 Oct 2026
11 Oct 2026
11 Oct 2026
16 Nov 2026
11 Oct 2026
Bill of Quantity (BOQ)
Gujarat Metro Rail Corporation (GMRC) Limited
(SPV of Govt. of Gujarat and Govt. of India)
Formerly known as Metro Link Express for Gandhinagar and Ahmedabad (MEGA) Co. Ltd.
Block No.1, First Floor, Karmayogi Bhavan, Behind Nirman Bhavan,
Sector 10/A, Gandhinagar:
Corporate Identification No (CIN): U60200GJ2010SGC059407
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
PREAMBLE AND GENERAL REQUIREMENTS FOR ELEVATED SECTION
The Pricing Document shall be read in conjunction with technical Specification, Employers Requirement,
BOQ’s for the works and other provisions of the tender documents, Schematic tender drawings etc.
including Annexure, Appendix, Addendum / corrigendum and any other document forming part of the
Tender Document.
The Bill of Quantities shall be read in conjunction with the Instructions to the Tenderer, General Conditions of
1. Contract, Special Condition of Contract, Employers Requirement, Scope of work, technical specifications and
drawings etc. If the specifications in the scope of work, Employers Requirement, Technical specification are
inferior with respect to relevant codes and standards then the provision of the Codes and Standards shall
prevail and vice versa. The decision of the Engineer-in- charge regarding this issue shall be binding on the
The quantities given in the Bill of Quantities are estimated and provisional and are given to provide a common
2. basis for bidding. The basis of payment will be the actual quantities of work carried out, as measured by the
Contractor and verified by the Engineer and valued at the rates and prices tendered and accepted in the priced
Bill of Quantities, where applicable, and otherwise at such rates and prices as the Engineer may fix within the
terms of the Contract. The final executed work quantities may vary.
The rates for each item and the Schedule of Items shall be written in indelible ink or type written in the
3. summary sheet in words and figures. Therefore, the quoted price for each Schedule shall be calculated and
written against each Schedule of the work. The total price, as sum of quoted price for all the Schedules of the
work shall be shown at the bottom of the summary sheet. The total price shall also be written in words and
figures. In case of any discrepancy, the amount written in words will be taken. The percentage/item rates shall
be quoted and amount evaluated in Indian Rupees only. as applicable against Schedule/items in BOQ, both in
figures and in words. The person authorized to sign on behalf of the tenderer shall sign in full at bottom of all
pages and at the end of schedule.
All the item of works which are not covered in BOQ Schedule A, B and C1 of structure Section, but are required
4. to be carried out as per the direction of Engineer-in-Charge, shall be carried out under the Schedule-C2 i.e.
Provisional Sum Schedule as per below preference.
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be as per rates mentioned in above SOR excluding GST)
The rates in BOQ are exclusive of GST (18%) and custom duties but including all other Taxes and cess, octroi
5. etc. as on date of submission.
If the Tenderer fails to fill up the percentage rate, “In each Schedule of the Summary sheets” the offer will be
6. evaluated based on the Par rate (cash value rate of the tender) given in the BOQs and no claim on account of
this will be entertained from the tenderer. However, GMRCL reserve the right to disqualify the tenderer.
General directions and descriptions of work and materials are not necessarily repeated or detailed in the Bill
7. of Quantities. References to the relevant specifications and sections of the contract documentation should be
made before quoting rates in the Bill of Quantities.
The rates are deemed to be inclusive of all lead (except as otherwise specifically provided in the description of
8. the particular item), lifts, ascend, descend, handling, rehandling, crossing of Nallah/Streams/Tracks any other
All enabling works for executing the work e.g. approach road to site, launching arrangements, arrangement of
9. water and electricity and any other incidental works which can be reasonably be inferred to be required for
completing the works is to be arranged by the contractor at his own cost and deemed to be included in the
In all concreting items, all material, equipment, labour, casting beds, stress frames, form work staging,
10. scaffolding, etc is to be arranged by the contractor within the quoted rates.
Storage of Material: All the material at site will have to be properly stacked & stored so as to facilitate
11. inspection. The material should be properly protected from the detrimental effects of nature and fire, theft etc.
The contractor shall be responsible for watch & ward and any loss or deterioration on account of above shall
lead to rejection of material and the contractor has to replace the same at his own cost.
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
The method of measurement of completed work for payment shall be in accordance with provisions in
12. Contract/Specifications except as otherwise specifically provided in the description of item or particular bill
of quantities or explanatory notes to the particular bill of quantities.
Obtaining prior permission for felling/cutting of trees will be in the scope of Contractor.
All materials to be supplied by the contractor within the quoted rate for the respective item.
All design mix concrete shall be machine batched with automatic weigh batcher, machine mixed and machine
15. vibrated or Ready Mix Concrete prepared in batching plant and transported by transit mixer to the site of work
or as directed by the structural designer.
The installation price of switchboards, metering panels, DB's or any other items shall include supply and fixing
16. of supporting steel structures/MS channels grouting of the same, associated civil works etc., as required. No
change in unit rate shall be allowed for any change in quantity or for any other reason whatsoever.
Prior to demolishing of any structure measurements will have to be taken. Scheme of dismantling has to be got
17. approved from the Engineer-in-charge.
All activities not specifically covered in BOQ /Schedule of Items, but required to be executed in order to
18. complete the Scope of work have to be deemed as covered with in these mentioned items of the Schedule /
Errors will be corrected by the Employer for any arithmetical errors in computation or summation as indicated
19. in the Contract Document.
The contractor must see the site conditions such as type of soil, locations etc., and take all factors into
20. consideration while quoting in the BOQ as no extra cost will be allowed on any ground arising out of or relating
to the site conditions. earth resistivity testing, water testing all shall be carried and cost of same shall be
considered included in the bid.
The contractor shall take into account the expenses of pre-commissioning tests to be conducted as per
21. specification of the complete installation by licensed agencies.
All temporary works shall be carried out by the contractor including temporary lighting & power at station
22. areas, Switchboards, DG sets, cables, stores, etc.
Repairs to damage of existing carriage way, canal work etc. during construction work shall be carried out by
23. contractor at his own cost as per the technical specifications. Prior to start of repairing work, scheme of repair
work shall be got approved from Engineer in charge.
For all type of cement concrete work rate shall inclusive of
24. I. The rate shall include cost of all necessary admixtures required as per mix design, curing, casting including
centering, shuttering, propping, staging, scaffolding, necessary tools, plants, machinery and all related
operations, etc.
II. The rate shall include cost of carrying out concrete mix design from approved laboratory as described in
the specification or as approved by Engineer-in-charge.
III. The rate is inclusive of all materials, including, mixing in fully automatic batch mix plant, transportation by
transit mixer for any lead from plant site, pumping, pouring, curing, placing in position, making good the
damages, with all lift with contractor's labour, tools & plants, machineries, as required.
IV. The rate is inclusive of providing formwork for exposed form finished concrete surface for concrete above
ground level in desired pattern, sizes with grooves, using laminated shuttering plywood/steel shuttering,
including neat cleaning & rendering of exposed concrete surface, as per the sample approved by the Architect
and as directed by the Engineer-in-charge. (Same kind of shuttering material should be only used for standard
and residual sizes)
V. The rate is inclusive of roughening and/or hacking exposed concrete surfaces for key for plastering, grinding
with carborundum stone over concrete spills / level difference in joints of concrete.
VI. The rate is inclusive of cost of providing grooves, chamfers, moulding, cutout etc. in formwork & using
required dosage of plasticizer in concrete for obtaining required workability as per approval of Engineer-in-
charge. The work will include vibration of concrete, curing protecting from damage, bailing/pumping out
water if required, levelling of ground, making site good etc.
VII. The rate is included labour for keeping embedment if any wherever required while casting.
VIII. The rate shall include form liner finish as per drawing / technical specifications.
The Tenderer’s offer shall be exclusive of GST. Income Tax and any other statutory taxes to be deducted at
25. source, if any, will be deducted by the Employer in accordance with the Income Tax Act and any other acts in
force and in accordance with instructions issued by the Authorities on this behalf, from time to time.
The Tenderer is required to furnish the PAN for all members of Group.
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
The rates and prices to be tendered in the Bill of Quantities are for completed and finished items of work and
27. complete in all respects. It will be deemed to have included all constructional plant, tools, machinery, labour,
supervision, materials, fuel, oil, consumables, elect& power, water, transportation, all leads and lifts,
dewatering, all temporary works and false works, construction of temporary stores and buildings, fencing,
watering, lighting, erection maintenance, night working, inspection facilities, safety measures at work sites
casting yard for workmen and road users, preparation of design and drawings pertaining to the casting yard,
staging, shuttering, form work, stacking yard etc., establishment and overhead charges, labour camps,
insurance costs for labour and works, contractor's profit, all taxes, royalties, duties, cess, octroi, and other
levies and other charges together with all general risks, liabilities and obligations set out or implied in the
contract and including remedy of any defects during the Defect Liability Period, unless otherwise provided in
Annexure-13A as duly filled in and priced should be invariably submitted in the Financial Package as
28. mentioned under Para C15.1 of the I.T.T (Instruction to Tenderers) under Volume-1 of Tender-Document and
the evaluation of Financial Package by the Employer will be done in accordance with Para E5 of ITT and other
relevant terms and conditions of the Tender.
Tender Total to be sum of total amount as derived/ quoted in the summary sheet along with addition of Price
Tender Total to be sum of total amount as derived/ quoted in the summary sheet along with addition of Price
29. of unqualified withdrawal of all conditions of Deviation, as per Annexure-13A, if any. This Tender Total will be
used for comparative evaluation of the Tenders.
The tenderer shall include in the Annexure – 2, Tax Estimate of the tender document, the rates/amounts
30. considered in the state and central Tax, duties, levies and included in the tender price and Gujarat state
government taxes, cesses and levies.
The tenderer should quote his percentage against each Schedule in the “summary sheets of each part” only on
31. N Procurement Portal and nowhere else.
The preparation and submission of the design, drawings, etc. for the complete façade works, unitized structural
32. DGU glazing system and all of its elements, roofing with structural steel, space frame, polycarbonate sheet for
the courtyard and atrium, canopies shades at various locations, etc. is in the contractor's scope. The contractor
shall submit 3 qualified façade vendors/structural designers with substantial experience in similar projects.
GMRC will review and select the vendor. The contractor must then obtain designs from the selected vendor
and submit all designs, drawings, and calculations for approval.
All design criteria must comply with relevant codes, force factors, and load factors while maintaining the
original architectural intent. Following design approval, the contractor shall create mockups for final approval
by the Architect/GMRC before proceeding with execution. All these requirements are included in the
contractor's scope, and no additional payment will be made for these items.
The successful contractor shall submit the material sampled which are in co-ordination with interior work like,
33. detector, camera, switchboard, Distribution board, lighting, speakers etc.., to the Engineer for approval prior
to supply/commencement of such works. The approval of these samples to be sought from architect/GMRCL.
Any choice of color model aesthetical options from approved makes shall be supplied by contactor at no extra
cost / commercials.
All material to be supplied at site shall be pre intimated to the engineer along with supporting FAT, material
34. test, type test reports and qty sheet along with specification compliance, unless the same is approved and
accepted the material shall not be supplied at site.
All expenses related to material FAT at factory or OEM location shall be borne by contractor, also the cost shall
35. include transportation, lodging & boarding of engineer / GMRCL team attending the testing at factory / OEM
location weather local / abroad.
The successful contractor shall submit 100% compliance against each and every BOQ line items & material
36. specification before work commencement at site or any material delivery at site.
The successful contractor shall submit the Schematic diagrams, fabrication drawings with details of all
37. equipment like D.G, Pumps, wirings diagrams etc., to the Engineer for approval prior to
supply/commencement of such works. The approval of these drawings will be general and will not absolve the
contractor of the responsibility of the correctness of these drawings. At least six copies of the approved
drawings shall be submitted to the Engineer for their distribution to various agencies at site at no cost to the
All testing and calibrating charges for the Meters shall be included in the installation price of the Meter Cubicle.
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
High voltage testing by Voltage Boosters, relay calibration by secondary injection and meter calibration have
39. to be carried out at site by authorized agencies.
The contractor shall carry out DG set testing and commissioning including supply of fuel & other
40. consumables/accessories at site without any extra cost for supply of fuel & other consumables/accessories as
required or instructed by the Engineer. Supply of fuel for testing shall be provided by the Contractor after
successful testing DG tank shall be filled by contractor. All the charges for fuel is also included. No seperate
payment shall be made for the supply of fuel.
The contractor shall supply all equipment, spares and consumables required for 104 weeks of Defect Liability
All wall and floor openings where cable containments are passing through shall be sealed with 2-hour fire
42. rated sealant after completion of cable pulling or installation.
The rate also includes all charges like packing and forwarding charges, handling, loading, unloading,
43. transportation, transit and other insurance, hoisting to all levels, setting and fixing in position, disposal of
debris including all other labour, Liabilities, obligations and risks arising out of conditions of contract and
Liasoning for obtaining approval from CEIG, Fire clearances, Electrical Inspectorate & Local authorities.
All enabling works for executing the work e.g. approach road to site, launching arrangements, arrangement of
44. water and electricity and any other incidental works which can be reasonably be inferred to be required for
completing the works is to be arranged by the contractor at his own cost and deemed to be included in the
All items of E&M works which are not covered in BOQ but are required to be carried out as per direction of
45. engineer in charge will be based on list of concerned item as available in DSR (E&M)
Payment for scheduled E&M works shall be made as follows:
1) 65% on supply and delivery
2) 10% on installation
3) 15% on testing and commissioning
4) 5% on integrated testing and commissioning
5) 5% on taking over
Payment for the Comprehensive Annual Maintenance Contract (CAMC) shall be made in equal quarterly
47. instalments over the 5-year contract period (totalling 20 instalments), payable at the end of each quarter upon
submission of the service report and invoice.
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Name of Work: Construction of 12.527 km Elevated Viaduct from Shilaj Circle to Badrabad Dead End, including 7 Nos. elevated Stations, E&M Works
for Ahmedabad Metro Rail Project.
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
Total Amount (INR)
(including percent
above / below / at
Schedule No. & Description Basic Cost (INR) % at Par/above/below
S No Amount At Par
Section Description of Section In Figure In Words In Figure Word
1 Schedule-A General
2 Schedule -B1 Foundation Work
3 Schedule -B2 Cast in Situ Concrete Work
4 Schedule -B3 Precast Concrete Work
5 Schedule -B4 Reinforcement and Restressing Steel
6 Schedule -B5 Structural Steel
7 Schedule -B6 Bearing
8 Schedule -B7 Miscellaneous Work
9 Schedule -B8 Structural steel for Open Web Girder
10 Schedule -C1 Electrical System Works
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Name of Work: Construction of 12.527 km Elevated Viaduct from Shilaj Circle to Badrabad Dead End, including 7 Nos. elevated Stations, E&M Works
for Ahmedabad Metro Rail Project.
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
Total Amount (INR)
(including percent
above / below / at
Schedule No. & Description Basic Cost (INR) % at Par/above/below
S No Amount At Par
Section Description of Section In Figure In Words In Figure Word
Fire Alarm System & Fire Fighting System
11 Schedule -C2
Air Conditioning & Ventilation System
12 Schedule -C3
13 Schedule -C4 Building Management System Works
Comprehensive Annual Maintenance for
14 Schedule -C5 Years for completed Electrical and
Mechanical system works.
Provisional Sum for Electrical System, Fire
Alarm System & Fire Fighting System, Air
15 Schedule -C6 Conditioning and Ventilation System,
Building Management System and
Miscellaneous Works.
16 Schedule-D1 Road works Item under R&B SOR 2023-24
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Name of Work: Construction of 12.527 km Elevated Viaduct from Shilaj Circle to Badrabad Dead End, including 7 Nos. elevated Stations, E&M Works
for Ahmedabad Metro Rail Project.
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
Total Amount (INR)
(including percent
above / below / at
Schedule No. & Description Basic Cost (INR) % at Par/above/below
S No Amount At Par
Section Description of Section In Figure In Words In Figure Word
Any other items not covered in Schedule A,
17 Schedule-D2 B & D1 but are required to be carried out
as per direction of Engineer, the order of
preference for adopting rates is as follows:
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be as per rates
mentioned in above SOR excluding GST)
Total of Schedule A, B1, B2, B3, B4, B5, B6, B7, B8, C1, C2, C3, C4,
01. The tenderer shall quote a percentage (Above/Below/At Par) at SN. 1 to 17 of this summary Sheet only and nowhere else. Total of Schedule from S. No: 1 to
shall be Considered for Tender Evaluation.
02.For the purpose of comparative evaluation of tenders, the amount worked out from the quoted percentage (above/below/at par) or/and quoted rate of item as
applicable, in equivalent INR shall be compared amongst various tenders to determine the lowest evaluated tender applying provision of clause 1.1.3.1 (ix) of NIT.
03. The bidder’s quote to be filled in Annexure – 1 (i.e. Summary Sheet of Bill of Quantity), it should be exclusive of GST & Custom duties.
04. The tax bifurcation to be filled in Annexure – 2 (i.e. Details of Taxes and Duties.
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Summary of Bill of quantities
Section Description of Section Amount (Rs)
Schedule-A General
Schedule B:-Civil Structural work
Schedule -B1 Foundation work
Schedule -B2 Cast in Situ concrete work
Schedule -B3 Precast concrete work
Schedule -B4 Reinforcement and prestressing steel
Schedule -B5 Structural steel
Schedule -B6 Bearing
Schedule -B7 Miscellaneous work
Schedule -B8 OWG Steel Structure
Schedule -C E&M Works
Schedule - C1 Electrical System Works
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule - C2 Fire Alarm System & Fire Fighting System Works
Schedule - C3 Air Conditioning & Ventilation System Works
Schedule - C4 Building Management System Works
Schedule - C5 Comprehensive Annual Maintenance for 5 Years for completed Electrical and Mechanical system
Schedule- C6 Provisional Sum for Electrical System,Fire Alarm System & Fire Fighting System, Air Conditioning
and Ventilation System, Building Management System and Miscellaneous Works
Schedule D: Provisional Sum
Schedule D1 Road works Item under R&B SOR 2023-24
Schedule D2 Any other items not covered in Schedule A, B & D1 but are required to be carried out as per
direction of Engineer, the order of preference for adopting rates is as follows:
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be rate of SOR excluding GST)
Total Amount (excl. GST)
Total Amount (excl. GST)
GMRC Page 10 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule A - General Items
Item Description Unit Rate (excl. Quantity Amount (Rs.)
Note: During the Contract period till the completion of the works the contractor shall
provide the following:
1 Surveying for verifying alignment, marking pier location, vertical & horizontal clearances KM
and establishing triangulation points and bench marks for the elevated corridor including 83,648.50 12.90
corrections, if any.
Note: The payment schedule for the item shall be as follows:
I. Payment @ 25% of total cost of the item on checking and approval of all control points
and submission of drawings.
ii.Payment @ 70% of total cost of the item equally distributed over the duration of the
contract and will be paid on pro-rata basis.
ii.Payment @ 5% of total cost of the item on satisfactory completion of work along with
the final bill.
(i) Payment @ 25% of total cost of the item on checking and approval of all control points and
submission of drawings.
(ii) Payment @ 70% of total cost of the item equally distributed over the duration of the
contract and will be paid on pro-rata basis.
(iii) Payment @ 5% of total cost of the item on satisfactory completion of work along with the
GMRC Page 11 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
2 Providing temporary barricade in good condition (new/refurbished) including all road RM
safety devices on both sides of viaduct/stations during construction at site as per technical 4,975.10 -
specifications and GFC drawings. Temporary barricade shall be of plain MS sheet 16 Gauge
fixed with steel frame as per drawing, painting (including primer of approved quality) with
synthetic enamel paint of approved color, quality and brand, writing lettering and logo of
Metro including maintenance of the same duly cleaning the same on fortnightly basis and
painting if required, arrangement for blinker lights/ rope light on barricades during night
as per requirement and as per the instruction of the Engineer-in-charge. During the
construction, barricading has to be kept continuously. Nothing extra will be paid for
dismantling and re-erecting the barricades within contract boudry. There should not be
any opening at the end of barricade except at locations approved by Engineer-in-charge.
(Barricading for road widening work shall be measured separately). Barricading may be
required to be shifted laterally number of times as per site requirements/sequence of
works but payment will be made only on first installation. In case of variation in weight per
RM, the prorata rate adjustment will be made for 70% of cost
Note:(i) Barricades on either side shall be measured individually.(ii) Once barricade has
been provided and work started, removal of barricade is not permitted till completion of - -
pile, pile cap, pier and pier caps, portal beams, superstructure complete , till completion of
entire superstructure.(iii) While erecting barricade, the bottom gap between barricade
and road should be plugged with cement concrete from inside.(iv) Adequate blinking lights
(rope light) on barricade during night time must be ensured. The cost of this item should
GMRC Page 12 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
include provision for power pack / Genset etc. so as to ensure the blinking of lights in night
time as long as barricades are in position at the work spot.
(v) After completion of the entire work, the barricades shall be the property of the
contractor.(vi) Replacement of damaged barricades shall be done by contractor at his own - -
cost. Nothig shall be payable extra.It is specifically highlighted that barricading during
construction shall be limited to 8m to 10m width only, considering the traffic constraint.
This width applies to viaduct in straight portion. In station areas and on curves, the
barricading width and placing shall be as approved by the Engineer in consulation with the
traffic management.For barricading payment shall be made at 70% on erection of
barricade and 30% on removal of barricade as per the instructions of Engineer in-charge.
(i) For barricading payment shall be made at 70% on erection of barricade RM
(ii) 30% on removal of barricade as per the instructions of Engineer in-charge. RM
3 Submit colour photographs (Ground/Aerial) of the works as directed by the Engineer-in- Per
charge and supply at monthly intervals, or as instructed by the Engineer-in-charge. One set month 1,989.00 36.00
shall comprise one soft copy with three copies of prints (hard copy in Glossy paper) of each
photograph of size not less than 225 x 175 mm each. (40 to 50 nos per month).
4 Supply of Ground/Aerial video and DVDs/pendrive of 180 minutes duration comprising one Per
master copy and one extra copy as per technical specifications showing the progress of month 9,945.00 36.00
works as directed by Engineer-in-charge.
GMRC Page 13 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
5 Providing furnished office accommodation at site for the use of site engineer and his Per
supporting staff approximately of 700 sqm carpet area (fully air conditioned) including site month 4,55,000.00 36.00
office at casting yard with minimum two watchman and two office boy in each office for
24hrs and also as per increased on its requirement. Offices may be at single or multiple
locations as directed by the Engineer-in-charge.
Note: 1) The details of site office and furniture, computer equipment, software etc., to be
provided by the Tenderer, are shown in the "Employers requirement". - -
2) This furnished accommodation shall be provided by the Tenderer during the contract
period and also extended period of the contract.
3) For the extended period of contract, contractor will be paid only the actual expenditure
incurred for operating this item. No extra payment will be allowed.
6 Cutting, transporting of trees including primary root, stacking and handing over to the
concerned department as per instruction of Engineer-in-charge. - -
(i) Girth upto 30cm Nos.
(ii) Girth more than 30cm but upto 50cm Nos.
(iii) Girth more than 50cm but upto 75cm Nos.
(iv) Girth more than 75cm but upto 1.25m Nos.
GMRC Page 14 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
(v) Girth more than 1.25m but upto 2.4m Nos.
(vi) Girth More than 2.4m Nos.
7 Transplanting the marked trees of various species and girth to the place shown by
Engineer-in- charge/Engineer’s representative within a lead of 1.5km with all tools, plants, - -
man & machinery and necessary preparation such as preparation of earth ball of tree roots
of desired depth & diameters, dislodging, lifting, transportation and transplanting tree
from original place to the new place including all arrangements, tools & plants, labour etc.,
for successfully completing the work. The work includes excavating pits of adequate size,
arranging loose soil, mixing of manure, fertilizer, insecticides etc., to ensure survival of the
trees being transplanted. Maintenance of tree i.e., watering, manuring, soil heaping, spray
of insecticides shall be done for one year. All above operations shall be executed as per
(i) Girth upto 30cm Nos.
(ii) Girth more than 30cm but upto 50cm Nos.
(iii) Girth more than 50cm but upto 75cm Nos.
(iv) Girth more than 75cm but upto 1.25m Nos.
(v) Girth more than 1.25m but upto 2.4m Nos.
(vi) Girth More than 2.4m Nos.
Stage wise payment for the work will be as following:
30% after trees transplanted. - -
40% after sprouting & establishment of trees
30% after completion of maintenance period of one year.
GMRC Page 15 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
7(a) Extra over item no A.7 (above) for lead more than 1.5 km and upto 5 km for all girth for per km
transportation (per km) 663.00 50.00
8 Carryout Geo-technical investigation work (as and where required) including exploratory RM
drilling of 150 mm dia boreholes in all sorts of soil, ordinary rock and hard rock, up to 1,989.00 1,080.00
maximum depth as mentioned, collecting undisturbed samples and conducting standard
penetration tests alternate at an interval of 1.5 m. depth, conducting necessary laboratory
tests & field tests for all type of classification and determination of soil parameters like
density, shear and consolidation parameters if required, including submission of report in
three copies covering investigation data and recommendation for SBC and the pile capacity
considering the design criteria, all as per specification.
1)The rate is inclusive of submitting soil investigation report in three sets in hard copy as
well soft copies.
9 Traffic Signals, Signage Etc.
9(a) Providing & fixing of retro-reflective traffic sign boards using high intensity Retro Reflective sqm
Sheeting (encapsulated lens type) as recommended by IRC and MORTH on 2mm 7,186.40 250.00
Aluminium Substrate properly processed on front side of Aluminium substrate with
pressure sensitive Heat vacuum applicator. Logos and Borders may be out of cut-sheet or
screen printing with appropriate ink which should also have 7 years warranty. The Retro
Reflective traffic sign boards using high intensity Tape should have MS angle support of
size 25 x 25 x 3 mm or 35 x 35 x 4 mm depending upon the size.
9(b) Providing and fixing and maintaining the road infrastructure/furniture during executions,
refixing as where required. - -
GMRC Page 16 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
(i) Road delineator - Supply of Rectangular Metal Delineator (Black colour Rectangular Nos
Delineator with high intensity Reflective Sheet)Height: 1200 mm approx..Size: 100 x 40 mm 1,259.70 300.00
rectangular Reflective: 1 no. Band of 120 mm High Intensity Grade RedColour Reflective
tape and 3 Nos. Bande of 150 mm white colour paint.
(ii) Portable Signage - Supporting of Retro-Reflective Sign Board of size 900 mm Triangular or Nos
60 mm Dia Circle or 90 x 600 mm by using high intensity Retro Reflective Sheeting on 2 mm 4,641.00 200.00
thick Aluminium Substrate with M.S. Back Support frame
(iii) Reflective lights - Hazards warning Blinkers both sides (Rechargeable with 2 Nos. Nos
sealed maintenance free batteries) 1,989.00 500.00
(iv) Traffic Cones Nos
Square Base cone with heavy base of size 390 mm x 390 mm Height: 705 mm
Cone Colour: Red Colour (UV stabilized) - -
Body Material: Low Density Poly Ethylene
Reflective Part: 1 No. White colour Engineering Grade Reflective band of 125 mm width all
Note: - The specifications given in this BOQ item are not complete. In addition, the items
shall comply with the regulations and Tender Specifications. After completion of the entire - -
work, all the items will be the property of the contractor and he is also responsible for
shifting all such release materials away from the site.
9(c ) Deployment of adequate manpower for 8hrs shift for day and night management of traffic
at intersection, roadway influenced by contractor and traffic diversions at various levels. - -
GMRC Page 17 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
In-charge-(minimum 1) shift
Supervisor-(minimum 2) shift
Traffic Guards-(maximum 50 man days per day) shift
Note : The deployment to be done with prior approval of GMRCL and Traffic Police. The
personnel at above should be familiar with traffic rules and regulations the traffic signals
and road delineators shall be placed as per approved plan and shall be prepared as per
relevant code and Ahmedabad Traffic Police guideline.
10 Construction of rainwater harvesting well consisting of 4.5m internal dia, 4.5m deep with Each
1 no. 200 mm nominal dia. PVC plain screen pipe with ribs conforming to IS: 12818-1992, 2,69,312
upto sub soil water table, including boring etc. Earth work excavation upto required depth,
brick masonry 75 class brick in cement mortar 1:4 foundation concrete 1:4:8, 150 mm thick
RCC top slab with steel reinforcement, centering and shuttering 1 no. precast RCC EHD
manhole cover & frame, with 8 mm thick plastic encapsulated foot rest at the rate of
300mm c/c, 400 mm thick fine sand and 600mm thick stone aggregate (6mm to 40mm
nominal size), at bottom level complete as per detail drawings, nothing extra will be paid.
SCHEDULE A - TOTAL AMOUNT
SCHEDULE A - TOTAL AMOUNT
GMRC Page 18 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
GMRC Page 19 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B1 - FOUNDATION WORK
Item Description Unit Rate (excl. Quantity Amount (Rs.)
1 Providing Excavation for utility mapping and shifting based on site Cum
condition. This shall includes following items 423.42
1. Excavation through existing concrete/ water bound macadam road /
bituminous road / concrete road/soil/morrum/ hard rock /soft rock/ old
structures below ground as encountered of all thickness including
dismantling other structures, dead utilities, dewatering, pumping and
bailing out water, strutting and shoring, etc. for utility identification shall
be done by either manually or with necessary precautions so that existing
utility shall not damage. At each pier location sizes of excavation pits will
2. Temporary suppurt for utility if required.
3. utility mapping and submission of utility mapping in soft and hard copy
with plan,elevation and cross-sections coordinates in autocad and with
photographs for submission to DDC review.
4. If boring will required, same will be paid in separate item (Ref item no
5. If utility shifting is required it shall be paid under relevant BOQ item.
6. Back fill of excavated soil upto natural ground level with sufficient
compaction for required stability of piling rig during piling work.
2 Boring 100mm dia borehole, 8m deep at pile locations to find out RM
underground utilities as directed by Engineer in charge. 705.58
GMRC Page 20 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
3 Providing and installing cast-in-situ vertical bored piles as per approved - -
good for construction (GFC) drawing and with M35 grade of concrete (as
per specification) using OPC cement confirming to sulphate concentration
criteria as per Sl. No. (i) & (ii) of Table 4 of IS 456 and for high concetration
sulphate content the type of cement shall be used as per Sl. No. (iii), (iv) &
(iv) of Table 4 of IS 456, including all operations such as installation and
shifting of piling rig etc, in all type of soil strata/rocky strata along elevated
section. Minimum cement content shall be 380kg/cum. The cost includes
the cost of empty boring wherever required. (Measurement shall be from
cut-off level to founding level). The stated length includes test piles for
initial load tests. The item includes disposal of earth, muck, slush released
from piles, top cutted portion of pile at disposal ground for all leads.
Reinforcement shall be paid separately. Rate shall include cost of using
required dosage of admixture in concrete for obtaining required
workability as per approval of Engineer in charge. Rate shall includes
provision of A class MS pipes of 50mm outer diameter as per technical
specification, minimum 1.0mm thick (light) as per IS 1239M in all piles
at the time of casting to be used for cross-hole sonic test. Pipes shall
extend from ground level to bottom of pile where pipe shall be sealed
at bottom. Rate includes filling of tubes after sonic test using standard
cement non-shrink mortar before casting of pile cap. The item includes
drilling and socketing in rock at required depth. Idling of rig due to any
reason shall not be payable. Bore drilling shall be done by use of hydraulic
rig using temporary casing of required depth and polymer slurry. The item
includes the cost of polymer to be used for stabilisation of bore.
Note: 800mm dia/ 1000 mm dia /1200 mm dia /1500 mm dia/1800 mm - -
dia multiple pile foundation will be implemented. The lengths of each pile
diameter is indicative only and may vary at Detailed Design stage.
3.1 For 800mm dia Pile RM
3.2 For 1000mm dia Pile RM
GMRC Page 21 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
3.3 For 1200mm dia Pile RM
3.4 Extra over item no B3 (above) for providing M40 grade concrete for pile cum
instead of M35 grade concrete. (Minimum cement content shall be 390 350.83
kg/cum of concrete)
4 Providing and fixing permanent MS liner (of required thickness or as MT
directed by Engineer-in-charge) for 800/1000/1200/1500/1800 mm dia 1,04,401.90
bored cast-in-situ piles wherever required as per approved construction
drawings and directions of Engineer-in-charge all complete and applying a
primer coat of approved steel primer.
Measurement :- The liner shall be of MS plate, of required thickness or as - -
per drawings duly approved. The payment of liner shall be made in Kg as
per the area of the MS sheet provided in liner multiplied by density (78.5
kN/m3). The quoted rates will be applicable for all lengths provided upto
the soffit of pile cap. The measurement will be made for the actual length
of liner provided correct to one centimeter.
5 Carrying out static initial vertical load tests as per relevant IS Codes - -
including all arrangements for measuring deflections and submitting
reports as per specifications. This includes making of pile head ready for
testing at the desired level, supporting / reaction arrangement
(including reaction piles/soil/rock anchors, if any) for the kentledge
load. Cost of pile to be tested wil be paid in item B.3. The test
arrangements shall cater for additional 25% above test load)
(i) 800 mm dia pile (Test load of 680MT) Nos.
(ii) 1000 mm dia pile (Test load of 1200MT) Nos.
(iii) 1200 mm dia pile (Test load of 1800MT) Nos.
GMRC Page 22 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
6 Carrying out static initial lateral load tests as per relevant IS Codes - -
including all arrangements for measuring deflections and submitting
reports as per specification and tender drawing. This includes making of
pile head ready for testing at the desired level, supporting / reaction
arrangement (include reaction piles/ soil/ rock anchors, if any) for the
kentledge load. (Cost of test pile will be paid in item B.3 )
(i) 800 mm dia pile (Test load of 38MT) Nos.
(ii) 1000 mm dia pile (Test load of 50MT) Nos.
(iii) 1200 mm dia pile (Test load of 63MT) Nos.
7 Carrying out static routine vertical load tests as per relevant IS - -
Codes including all arrangements for measuring deflections and
submitting reports. This includes making of pile head ready for testing at
the desired level, supporting / reaction arrangement (incl. reaction
piles/soil/rock anchors, if any) for the kentledge load. The test
arrangements shall cater for additional 25% above test load.
(i) 800 mm dia pile (Test load of 375MT) Nos.
(ii) 1000 mm dia pile (Test load of 675MT) Nos.
(iii) 1200 mm dia pile (Test load of 975MT) Nos.
8 Carrying out static routine lateral load tests as per relevant IS Codes - -
including all arrangements for measuring deflections and submitting
reports. This includes making of pile head ready for testing at the desired
level, supporting / reaction arrangement (incl. reaction piles/ soil/ rock
anchors, if any) for the kentledge load.
(i) 800 mm dia pile (Test load of 23MT) Nos.
(ii) 1000 mm dia pile (Test load of 30MT) Nos.
GMRC Page 23 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
(iii) 1200 mm dia pile (Test load of 38MT) Nos.
9 Non destructive integrity testing of piles of 800mm/ 1000 mm/1200 mm Nos.
/1500mm /1800mm dia and as per specifications and submitting reports. 1,169.44
(Payment shall be made for number of pile tested)
10 Integrity pile test using cross-hole sonic logging for 0.8m, 1.0m, 1.2m, Nos.
1.5m, 1.8m diameter piles as per the provision of ASTM standard D6760, 8,770.78
as per drawings & technical specifications. (Payment shall be made for
number of pile tested)
11 Providing M-15 grade concrete (as per specification) for minimum cum
75mm thick PCC below pile cap, open foundation slabs and ramp 4,735.93
foundations extending 75mm all around beyond pile cap, open foundation
slabs and ramp foundations. Rate shall include cost of using required
dosage of admixture in concrete for obtaining required workability as
per approval of Engineer.
11a Providing M-15 grade concrete (as per specification) for minimum cum
75mm thick PCC below open foundation/ raft/ combined foooting for 4,735.93
other than station box area (i.e. entry- exit structures. water tanks,
escalator, lift pits, staircases pump house etc) extending 75mm all
around footing. Rate shall include cost of using required dosage of
admixture in concrete for obtaining required workability as per approval
GMRC Page 24 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
12 Providing M-35 grade, reinforced cement concrete (as per specification) cum
using OPC cement confirming to sulphate concentration criteria as per 6,948.92
Sl.No. (i) & (ii) of Table 4 of IS 456 and for high concetration sulphate
content the type of cement shall be used as per Sl. No. (iii), (iv) & (iv) of
Table 4 of IS 456, for pile cap including excavation through existing
concrete/ water bound macadam road / bituminous road / concrete road
/soil/morrum/ hard rock /soft rock/ old structures below ground as
encountered of all thickness including dismantling other structures, dead
utilities, dewatering, pumping and bailing out water, strutting and shoring,
curing etc.Minimum cement content shall be 380kg/cum. The item also
includes formwork and backfilling in foundation with quarry dust/sand
including watering, compacting with a vibratory plate compactor. The Cost
includes cutting/chipping of pile up to cut off level or up to good concrete
and built up of pile up to required level. The cost includes loading,
unloading and disposal of surplus excavated material along with pile heads
using covered trucks to contractor's dumping yard, / disposal of surplus
excavated material at with all leads and lifts and as directed by the
Engineer-in-charge or anyother dumping ground as directed by Engineer
within 40 Km of the alignment. The contractor should ensure that during
transportation the carried material does not spill out. Reinforcement shall
be paid separately. Rate shall include cost of using required dosage of
admixture in concrete for obtaining required workability as per approval
of Engineer-in-charge. (6% of the amount shall be withheld. Out of this,3
% of the amount shall be released after disposal of excavated material
including pile head material at contractor's dumping yard and 3 % of the
amount shall be released after restoration works on pile caps). Rate
includes restoration of road work over the excavation zone for pile cap i.e.
GSB and WMM over sand filling as per the instruction of the Engineer.
(i) 94% on pile Cap casting -
(ii) 3% on disposal exavted material -
(iii) 3% on restoration work -
GMRC Page 25 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
12 (a) Extra over item no 12 (above) for providing M45 grade concrete for pile cum
cap instead of M35 grade concrete. (Minimum cement content shall be 350.83
410 kg/cum of concrete)
12.(b) Providing M 35 grade, reinforced cement concrete (as per cum
specification) using OPC cement confirming to sulphate concentration 6,948.92
criteria as per Sl.No. (i) & (ii) of Table 4 of IS 456 and for high concetration
sulphate content the type of cement shall be used as per Sl. No.
(iii), (iv) & (iv) of Table 4 of IS 456, for pile cap / open foundation/
raft/ combined foooting for other than station box area (i.e. entry-
exit structures. water tanks, escalator, lift pits, staircases pump
house, FOB's etc) including excavation through existing concrete/
water bound macadam road / bituminous road / concrete road
/soil/morrum/ hard rock /soft rock/ old structures below ground as
encountered of all thickness including dismantling other structures,
dead utilities, dewatering, pumping and bailing out water, strutting and
shoring, curing etc. Minimum cement content shall be 380kg/cum. The
item also includes formwork and backfilling in foundation with
earth/quarry dust/sand including watering, compacting with a vibratory
plate compactor. The cost includes loading, unloading and disposal of
surplus excavated material using covered trucks to contractor's dumping
yard with all leads and lifts and as directed by the Engineer-in-charge. The
contractor should ensure that during transportation the carried material
does not spill out. Reinforcement shall be paid separately. Rate shall
include cost of using required dosage of admixture in concrete for
obtaining required workability as per approval of Engineer-in-charge. (6%
of the amount shall be withheld. Out of this,3 % of the amount shall be
released after disposal of excavated material including pile head material
at contractor's dumping yard and 3 % of the amount shall be released
after completing road restoration works. Rate includes restoration of road
work over the excavation zone. (Minimum cement content shall be
kg/cum of concrete)
GMRC Page 26 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
12 (c) Extra over item no 12 b (above) for providing M45 grade concrete for pile cum
cap instead of M35 grade concrete. (Minimum cement content shall be 350.83
410 kg/cum of concrete)
13 For all RCC items of schedule B1, minimum cement content has been Kg 6.21
specified. For any extra /less cement above or below the minimum
specified cement content, addition/deduction shall be paid under this
SCHEDULE B1 - Total Amount
SCHEDULE B1 - Total Amount
GMRC Page 27 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026
GMRC Page 28 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B2 - IN-SITU CONCRETE WORK
Item Description Unit Rate (excl. Quantity Amount (Rs.)
1 Providing and laying M-40 grade cement concret (as per technical cum 8,128.00 1931.93
specification) for reinforced cement concrete crash barrier/pier protection all
round the pier leaving a gap of 25mm min between and following the pier shape
exactly on at grade road as specified in drawings, including centering,
shuttering, compaction, scaffolding, curing and all related operations as
required to complete the work. The gap shall be filled with either coarse sand or
compressible filler board of high density as directed by Engineer in charge or as
per GFC drawings. Rate includes the cost of required dosage of admixture
in concrete for obtaining required workability and cost of compressible fibre
board or coarse sand as per specification and approval of Engineer in
charge.Reinforcement will be paid separately.
Minimum cement content shall be 390 kg/cum of concrete.
GMRC Page 29 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
2 Providing and laying M-55 grade reinforced cement concrete (as per cum 9,227.00 19506.90
specification) for Viaduct & Station piers (standard pier, portal pier, &
cantilever pier, Cantilever pier cap, Standard Pier cap, Column from concourse
slab to platform level, Pedestals) etc and column for stations including
shuttering scaffolding and all related operations required to complete the work
at all levels including centering, shuttering, propping, staging, scaffolding,
compaction, curing, necessary tools, plants, machinery and all related
operations etc.for all heights using steel material for shuttering & steel props.
Form work to be designed in a such way that traffic on road is allowed during
the work at all times. Rate includes cost of providing grooves if required (the
ribs/grooves in pier shutter if required, shall be as per drawing).
Reinforcement shall be paid separately. Rate includes cost of using
required dosage of admixture in concrete for obtaining required
workability, curing compound as per specification & approval of Engineer in
charge. Minimum cement content shall be 440 kg/cum of concrete.
Note:(i) No cold joints are permitted. However cold joint at the junction of " pile - -
cap-pier" and at the top surface of the starter of pier (which is normally less
than 2m length), cold joints are unavoidable. In that case old concrete
surface should have adequate shear keys depressions,reinforced dowels
and a layer of concrete bonding compound. Concrete retarder compound
may also have to be used at the concrete surface of starter pier above the pile
cap.The rate is inclusive of all above bonding agents/methods. However if
any additional cold joints are unavoidable due to the reasons not beyond
the control of contractor, all above bonding measures shall be on account of
the contractor.
(ii) Concreting must be carried out using concrete pumps or concrete placer
GMRC Page 30 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
2(a) Extra over item no 2 (above) for providing M60 grade reinforced cement cum 819.00 500.00
concrete instead of M55 grade concrete. Minimum cement content shall be
450kg/cum of concrete.
2(b) Deduction for Providing M40/20 concrete instead of M55/20 concrete in above Cum -241.00 500.00 -1,20,500.00
Concrete items. Minimum cement content shall be 390 kg/cum of concrete.
3 Providing and laying M 40 grade reinforced cement concrete (as per cum 8,439.00 5258.40
specification) for station beam and slab (Beam/slab at concourse level, wall
and slab for Lift, beam and slab for staircase & escalator, Beam/slab/
parapet wall at Platform Level, Parapets, Pedestals at Platform Level, Cable
Trough etc) including shuttering scaffolding and all related operations
required to complete the work at all levels including centering, shuttering,
propping, staging, scaffolding, compaction, curing, necessary tools, plants,
machinery and all related operations etc.for all heights using steel material for
shuttering & steel props. Form work to be designed in a such way that traffic on
road is allowed during the work at all times. Rate includes cost of providing
grooves if required (the ribs/grooves in pier shutter if required, shall be
as per drawing) and sleeves with different diameters. Reinforcement shall
be paid separately. Rate includes cost of using required dosage of
admixture in concrete for obtaining required workability, curing compound
as per specification & as per specifications includes loading, unloading and all
complete as per approved drawings and specifications.
Minimum cement content shall be 390 kg/cum of concrete.
GMRC Page 31 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
4 Providing M 55 grade reinforced cement concrete for Reinforced concrete (as cum 10,264.00 804.00
per specification) for portal beam (integral to pier)/ Pier Cap including
shuttering scaffolding and all related operations required to complete the
work at all levels including centering, shuttering, propping, staging, scaffolding,
curing, necessary tools, plants, machinery and all related operations etc.for all
heights using steel material for shuttering & steel props. Form work to be
designed in a such way that traffic on road is allowed during the work at all
times Rate includes required dosage of admixture in concrete for obtaining
required workability as per approval of Engineer in Charge. Reinforcement
will be paid separately.Minimum cement content shall be 440 kg/cum of
4.b Extra over item no 4 (above) for providing M60 grade reinforced cement cum 819.00 100.00
concrete instead of M55 grade concrete.
Minimum cement content shall be 450 kg/cum of concrete.
5 Providing M 55 grade reinforced cement concrete (as per technical cum 10,310.00 1295.00
specification) for Pedestals and Shear Key/Seismic Stopper including centering,
steel shuttering, scaffolding and all related operations as required to complete
the work as specified in drawings. Reinforcement shall be paid separately. Rate
includes required dosage of admixture in concrete for obtaining required
workability as per approval of Engineer in charge.
Minimum cement content shall be 440 kg/cum of concrete.
GMRC Page 32 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
6 Providing M50 grade reinforced cement concrete (as per technical specification) cum 10,801.00 3492.75
for deck slab over Precast I Beams/Steel beams & cross-girder/FOB's etc
including centering, steel shuttering, scaffolding and all related
operations as required to complete the work as specified in drawings.
Rate includes provision of formwork of steel/concrete for casting of slab.
Reinforcement shall be paid separately. Rate includes required dosage of
admixture in concrete for obtaining required workability as per approval of
Engineer-in-charge.Minimum cement content shall be 430 kg/cum of concrete.
7 Providing M45 grade reinforced cement concrete (as per technical specification) cum 7,605.00 4943.40
for other than station box area (i.e. entry- exit structures. water tanks,
escalator, lift pits, staircases pump house etc) including centering, steel
shuttering, scaffolding and all related operations as required to complete the
work as specified in drawings. Rate includes provision of sacrificial formwork of
steel/concrete for casting. Reinforcement shall be paid separately. Rate includes
required dosage of admixture in concrete for obtaining required workability as
per approval of Engineer-in-charge.
Minimum cement content shall be 410 kg/cum of concrete.
8 Providing reinforced cement concrete for stitch concrete (all types and levels),
upstands (all types and levels), Diaphargm and similar elements, complete
with centering, steel shuttering, scaffolding, sacrificial formwork (steel/concrete
as required), and all related operations as per drawings and specifications.
Reinforcement shall be paid separately. Rate includes approved admixture
dosage for required workability as per Engineer-in-charge’s approval.
GMRC Page 33 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
a) M40 grade reinforced cement concrete (Minimum cement content shall be 390 Cum 8,128 4728.33
kg/cum of concrete)
b) M50 grade reinforced cement concrete (Minimum cement content shall be 430 Cum 9,196 250.00
kg/cum of concrete)
c) M55 grade reinforced cement concrete (Minimum cement content shall be 440 Cum 10,264 250.00
kg/cum of concrete)
9 For all RCC items of schedule B2, minimum cement content has been specified. Kg 6.21 105240.00
For any extra /less cement above or below the minimum specified cement
content, addition/deduction shall be paid under this items.
10 Providing, fabricating, supplying, transporting, placing and fixing galvanized sqm 609 7740.00
corrugated steel deck sheets instead of conventional temporary centering,
steel shuttering and scaffolding over Precast Beams/I-girder/Steel girder/cross-
girder/pie-girder etc as per the instruction of Engineer incharge. for casting of
RCC deck slab, including cutting, bending, lapping, fastening to girders with
shear studs/clips/self-drilling screws, providing edge trims, closures and all
accessories complete as per approved drawings and specifications. The rate
shall include all labour, materials, equipment, handling, wastage, staging
required for fixing, and all incidental works necessary for completion of the
item, measured in square metres of deck slab. The rate includes material,
labour. machinery, accessroies, fixtures etc at all levels and locations, all
complete as per instructions of Engineer Incharge.
SCHEDULE B2 - Total Amount
SCHEDULE B2 - Total Amount
GMRC Page 34 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026
GMRC Page 35 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B3 - PRECAST CONCRETE WORK
Item Description Item Rate (excl. GST) Quantity Amount (Rs.)
1a Establishment of casting yard; LS 1.00
Establishment of casting yard for all precast elements including batching plant -
for concrete production, storages, labs, office and other facilities to execute
the work as per good engineering practices and as approved by engineer to
ensure production and storage of all precast element to achieve the specified
key dates, comprising as mentioned below, which shall be increase/decrease
with approval of Engineer-in-charge, suitably to suit the construction schedue
for achieving the Key Dates (KDs)
A. Casting bed for U -girder - 36 nos. -
B. Casting bed for pier cap - 8 nos
C. Casting bed for I girder - 6 nos. I Girder
D. Batching plant capacity should be minimum 60 cum/hour & 30 cum/hour
The payment of this item shall be made as under
A. Developing access -10%
B. Establishing bed for U grider, I girder, pier cap and gantries - 40%.
C. Establishing of batching plant, labs, office - 30%
D. Completion of full facilities as approved by engineer -20%.
The amount shall be paid against the indemnity bond.
1.b Recovery against payment of establishment of casting yard LS -7,50,00,000.00
Recovery against payment of establishment of casting yard @ 15000000 in 5 -
GMRC Page 36 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
2 Providing M55 grade reinforced cement concrete (as per technical cum 12,598.21 9198.00
specification) Precast Prestressed Pier Cap/Precast portal beam including
shear key, pedestals, in-situ connection with pier. The item includes lifting the
pier caps from the mould and shifting the same to the stacking yard. The item
includes provision of holes for lifting and filling of holes after erection using
non-shrink grout. Reinforcement, strands, cables, anchorages and sheathing
shall be paid separately. Rate includes cost of using required dosage of
admixture in concrete for obtaining required workability as per approval of
Engineer-in-charge and all related operations as required to complete the
work as per drawing & specifications. The cost includes centering,
shuttering, scaffolding, providing cutouts where specified, curing
arrangements as required, steam curing arrangement if deemed necessary,
all handling etc. complete.Minimum cement content shall be 440 kg/cum of
3 Transporting precast Standard Pier Caps/Precast portal beam from the MT 1,475.35 22995.00
casting yard / storage yard to the work site, erection in position including the
cost of all temporary supports, erection equipment, lifting cranes,
transporting etc, positioning and fixing on pier with cement concrete of M55
grade. The weight shall be calculated assuming concrete density of 2.5 t/m³.
Shifting within the site/ yard is the responsibility of the contractor and shall not
be paid separately.
GMRC Page 37 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
4 Providing M55 grade reinfoced cement concrete (as per technical Cum 12,598.21 64464.00
specifications) for U-Girder of all simply supported spans (straight or curved) in
the casting yard including provision of shear connector for secondary pour
concrete (rail plinths), additional bars for earthing, bars/ strands/ hooks for
lifting of U-Girder, cutting of bars/ strands/ hooks after transportation and
sealing of lifting recess as specified in drawings, lifting the full spans from the
mould and shifting the same to the stacking yard. Reinforcement, strands,
debonding tubes, anchorages and sheathing shall be paid separately. Rate shall
include the cost of using reuired dosage of admixture for obtaining required
workability as per approval of Engineer in charge and all related operations as
required to complete the work as per drawings and specifications. Rate
includes cost of providing grooves/logo of client if required (the
ribs/grooves/logo in shutter if required, shall be as per drawing). Minimum
cement content shall be 440 kg/cum of concrete.
5 Providing HDPE debonding tubes for prestressing strands (to be cut-off RM 32.74 535846.97
flush to concrete after casting), epoxy based sealing compound at edges of
strand and epoxy putty to avoid slurry ingress during concreting. The quantity
given is the net length of tubes without extra tube length required
during construction. Rate includes filling HDPE tubes with grease as specified
6 Transporting precast full span U-Girder from the casting yard to work site, MT 1,286.38 161160.00
erection in position by using launching girder and shall not take any support
from ground / Road including the cost of all temporary supports, erection
equipment, lifting cranes, transporting etc, and positioning on bearings etc for
viaduct into completed structures conforming to required lines, grades and
dimensions complete as per drawings and specifications. The weight shall be
calculated assuming concrete density of 2.5 t/m³. Shifting within the site / yard
is the responsibility of the contractor and shall not be paid separately.U Girder
shall be launched/ Erected by using Lauching Girder and shall not take any
support from Ground or Road
GMRC Page 38 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
7 Providing, pre-casting and curing precast RCC beams concrete (cement as per cum 11,584.00 8123.50
technical specification) of all types I-Beam, Pie beams, L- beams, T- beams,
Rectangle beam etc. wherever required, complete of M40/20 grade for
Superstructure/Portal/Station Beams including shuttering and formwork etc.
Reinforcement shall be paid separately. Rate shall include cost of using
required dosage of admixture in concrete for obtaining required workability as
per approval of Engineer.
Minimum cement content shall be 390 kg/cum of concrete.
8 Providing, pre-casting and curing precast Pre tensioned / Post tensioned cum 11,705.00 10410.40
beams concrete (cement as per technical specification) of all types I-Beam, Pie
beams, L- beams, T- beams etc. complete of M50/20 grade for
superstructure/Portal/Station Beams etc. including shuttering and formwork
etc. Reinforcement shall be paid separately. Rate shall include cost of using
required dosage of admixture in concrete for obtaining required workability as
per approval of Engineer.
Minimum cement content shall be 430 kg/cum of concrete.
9 Transporting and erection of I-Beam, Pie beams, L- beams, T- beams, RCC- MT 1,286.38 46334.75
Beams, any other precast beams etc. into completed structures conforming to
required lines, installation of Spherical/POT PTFE/ all types of bearings etc. as
per the manual of bearing manufacturer under the supervision of bearing
manufacturer and as directed by the Engineer, grades and dimensions
complete as per drawings and specifications.
GMRC Page 39 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
10 Providing M55 grade reinforced cement concrete (as per technical cum 13,466.43 6192.00
specification) for casting and curing of Precast PSC I-Girder (Post
tensioned) with tapering width of all types (straight or curved spans as
per approved GAD) in the casting yard including provision of lifting the
girders from the mould and shifting the same to stacking yard. Prestressing
strands / cables / systems and reinforcement shall be paid separately. Rate
includes cost of lifting hook, using required dosage of admixture in
concrete for obtaining required workability as per approval of Engineer in
charge. Note : Type, size and number of shutter moulds shall be as per the GFC
drawings and nothing extra is payable.Minimum cement content shall be
kg/cum of concrete.
11 Transporting Precast PSC I-Girder from the casting yard to work site, MT 1,052.49 15480.00
erection in position including the cost of all temporary supprots, erection
equipments, lifting cranes, transporting etc, positioning on bearings and fixing
on pier. The weight shall be calculated assuming concrete density of 2.5 t/m3.
Shifting within the site/yard is the responsibility of contracor and shall not be
paid separately.
12 Providing M50 grade reinfoced cement concrete (as per technical Cum 12,736.00 693.00
specifications) for Precast Slab panel at concourse / Platform levels of typical
station of all simply supported spans (straight or curved) and Precast
Staircases in the casting yard including provision of shear connector for
secondary pour concrete, additional bars for earthing, bars/ strands/ hooks for
lifting of precast slab, cutting of bars/ strands/ hooks after transportation
and sealing of lifting recess as specified in drawings, lifting the full spans
from the mould and shifting the same to the stacking yard.
Reinforcement, strands, debonding tubes, anchorages and sheathing shall
be paid separately. Rate shall include the cost of using reuired dosage of
admixture for obtaining required workability as per approval of Engineer
in charge and all related operations as required to complete the work as
per drawings and specifications.
Minimum cement content shall be 430 kg/cum of concrete.
GMRC Page 40 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
13 Transporting precast Slab panel / Staircases from the casting yard to work site, MT 898.00 1732.50
erection in position including the cost of all temporary supports, erection
equipment, lifting cranes, transporting etc, and positioning on bearings/ steel
plates etc conforming to required lines, grades and dimensions complete as per
drawings and specifications. The weight shall be calculated assuming
concrete density of 2.5 t/m³. Shifting within the site / yard is the
responsibility of the contractor and shall not be paid separately
14 Providing M60 grade reinforced cement concrete (as per technical cum 12,667.32 11046.00
specification) for casting and curing of Precast pier arm / Cross Arm / Cross
Girder etc. of typical station (Post tensioned) including in-situ connection
with pier/column with tapering sction of all types in the casting yard
including provision of lifting the Pier arm from the mould and shifting the same
to stacking yard. Prestressing strands / cables / systems and reinforcement
shall be paid separately. Rate includes cost of lifting hook, using required
dosage of admixture in concrete for obtaining required workability as per
approval of Engineer in charge. Note : Type, size and number of shutter
moulds shall be as per the GFC drawings and nothing extra is payable.Minimum
cement content shall be 450 kg/cum of concrete.
15 Transporting Precast pier arm of typical station from the casting yard to work MT 1,475.35 27615.00
site, erection in position including the cost of all temporary supprots, erection
equipments, lifting cranes, transporting etc, positioning on pier. The weight
shall be calculated assuming concrete density of 2.5 t/m3. Shifting within the
site/yard is the responsibility of contracor and shall not be paid separately.
GMRC Page 41 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
16 Providing M55 grade reinforced cement concrete (as per technical cum 12,598.21 5174.40
specification) for casting and curing of Precast PSC U-girder (Post
tensioned) with tapering width of all types (straight or curved spans as
per approved GAD) in the casting yard/at site including provision of lifting the
girders from the mould and shifting the same to stacking yard. Prestressing
strands / cables / systems and reinforcement shall be paid separately.
Rate includes cost of lifting hook, using required dosage of admixture in
concrete for obtaining required workability as per approval of Engineer in
charge. Note : Type, size and number of shutter moulds shall be as per the
good for construction (GFC) drawings and nothing extra is payable. Minimum
cement content shall be 440 kg/cum of concrete.
17 Transporting Precast PSC U-girder (Post tensioned) from the casting yard MT 1,286.38 12936.00
to work site, erection in position including the cost of all temporary
supprots, erection equipments, lifting cranes, transporting etc, positioning
on bearings and fixing on pier. The weight shall be calculated assuming
concrete density of 2.5 t/m3. Shifting within the site/yard is the responsibility
of contracor and shall not be paid separately.
18 Providing M40 grade reinforced cement concrete (as per techinical cum 11,118.46 2064.00
specification) for concreting, curing, transporting, lifting, installing precast
parapet over Deck slab on both side of viaduct, including transition span as
per the drawing in all precast psc I-girder/steel girder spans (straight or
curved), with all leads. The cost includes shuttering, scaffolding, special
adjustable props for alignment of units, moulds, providing cut outs, bolts &
inserts for fixing signalling mast, curing, required dosage of admixture for
concrete, all handling, and fixing in position, etc. complete) with cast in situ
stitch concrete of same grade.Note: Payment at 50% of accepted rate on
casting and Balance 50% on completion of erection, stitch concrete and related
works. Rate includes cost of providing grooves/logo of client if required (the
ribs/grooves/logo in shutter if required, shall be as per drawing).Minimum
cement content shall be 390 kg/cum of concrete.
GMRC Page 42 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
19 Transportation, erection and installation of precast parapets over already MT 1,037.82 5160.00
erected superstructure(psc i- girder/steel girder portion) conforming to
required lines, grades and dimension complete as per drawings and
specifications including cast in situ stitch concrete of same grade including cast
in situ stitch concrete of same grade. The weight shall be calculated assuming
concrete density of 2.5 t/m³. Shifting within the site/yard is the responsibility of
the contractor and shall not be paid separately
20 For all RCC items of schedule B3, minimum cement content has been specified. Kg 6.21 172776.00
For any extra /less cement above or below the minimum specified cement
content, addition/deduction shall be paid under this items.
17 Load test of PSC I-Girder/Pie Girder/ T Girder spans of any length including Nos 2,87,681.63 3.00
making all arrangement and conducting satisfactory Load Testing of girder
(simply supported span constructed by I-Girders), erected in position on the
piers at site, including arrangement for application of actual design
serviceable vertical load, arrangement for measurement of deflection at
various salient points of the girder and submitting a report. The details
of placement, position, increment of load on the girder and installation of
measurement devices etc and additional measures (such as temperature
measures) shall be as directed by the Engineer. After completion of the test all
the materials used for the load testing shall be removed and site shall be made
clear. Rate shall include submission of method statement and third party
certification of the test.
GMRC Page 43 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
18 Load Test of U-girder spans of any length including making all arrangement and Nos 2,87,681.63 6.00
conducting satisfactory Load Testing of U-girder, erected in position on the
piers at site, including arrangement for application of actual design serviceable
vertical load, arrangement for measurement of deflection at various salient
points of the girder and submitting a report. The details of placement, position,
increment of load on the girder and installation of measurement devices etc.
shall be as directed by the Engineer. After completion of the test all the
materials used for the load testing shall be removed and site shall be made
clear. Rate shall include submission of method statement and third party
certification of the test.
19 Load Test of Precast Slab Panel including making all arrangement and Nos 2,87,681.63 1.00
conducting satisfactory Load Testing of Precast slab panel, erected in position
on the piers at site, including arrangement for application of actual design
serviceable vertical load, arrangement for measurement of deflection at
various salient points and submitting a report. The details of placement,
position, increment of load on the girder and installation of measurement
devices etc. shall be as directed by the Engineer-in-Charge. After completion of
the test all the materials used for the load testing shall be removed and
site shall be made clear. Rate shall include submission of method statement
and third party certification of the test.
GMRC Page 44 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
20 Load Test of Steel Plate girder/ OWG Span of any length including Nos 2,87,681.63 2.00
making all arrangement and conducting satisfactory Load Testing of steel
girder span, erected in position on the piers at site, including arrangement for
application of actual design serviceable vertical load, arrangement for
measurement of deflection at various salient points of the girder and
submitting a report. The details of placement, position, increment of load on
the girder and installation of measurement devices etc. shall be as
directed by the Engineer-in-Charge. After completion of the test all the
materials used for the load testing shall be removed and site shall be made
clear. Rate shall include submission of method statement and third party
certification of the test.
SCHEDULE B3 - Total Amount
SCHEDULE B3 - Total Amount
GMRC Page 45 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026
GMRC Page 46 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule- B4 REINFORCEMENT AND PRESTRESSING STEEL
Item Description Unit Rate (excl. Quantity Amount (Rs.)
1 Providing TMT reinforcement steel of Fe-550D Grade conforming to MT 72,648.00 50,164.15
IS1786 (latest) from approved list of supplier, cost of material,
royalty, transportation, handling, storing, straightening, cutting,
bending, tying, lap/butt welding, placing in position including 18 gauge
GI binding wire in diamond form at each reinforcement junction in all
structural concrete at all heights and depths with all leads complete as
directed. Rate shall also include welding involved towards stay
current protection effects as per system approved by Engineer-in-
charge. The rate shall also include the cost of binding wire, labour, all
material, tools and plants, all leads, lift etc. as per drawings and
technical specification as directed by Engineer-in-charge. The rate shall
also include protective coating as per technical specifications. This item
is applicable for all components of viaduct, station box area and other
than station box area (i.e. entry- exit structures. water tanks, escalator,
lift pits, staircases pump house etc)
GMRC Page 47 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Note:(i) No laps, joints are permitted in rebars provided in -
superstructures, piers, portals, pier arm, portal beams. However,
mechanical couplers are to be used without extra cost.(ii) For pile
reinforcement, welding of lap joint shall be without extra cost.
Additional rings required for handling the rebar cage shall be the
responsibility of the contractor and shall not be paid separately.(iii) For
other structural members, lap joints are permitted for bar dia <
20 mm, (including 20 mm), else, mechanical couplers are to be
provided, where in rebar ends shall be cold forged with die.(iv) The
cost includes all welding and providing mechanical couplers, all types of
laps, standard laps, chair, spacers, bend deduction as per IS-SP 34 etc.,
as required and nothing extra is payable on this account.v) Steel
considered for foundations is 30% (approximately) out of total quantity
for the purpose of processing variation of quantities.
2 Supplying and threading uncoated stress-relieved low relaxation steel MT 1,29,124.52 3,531.77
confirming to IS: 14268, class - 2 from approved supplier in precast
pretensioned U-girder/slab panels/T-girder/L-girder etc. for simply
supported spans including spacers, anchorages, stressing using
approved system and all related operations to complete the work.
This item includes providing and fixing all strands, de-bonding
arrangements (de-bonding tubes etc), required anchorages for
live and dead ends, stressing upto required level using all tools
and equipments and consumables cement grouting as per
specification and as directed by the Engineer-in-charge. Rate includes
filling de-bonding type with grease as specified in ASTM and taping at
the ends of the strand. Rate includes the testing complete- load
transfer, anchorage efficiency etc.
GMRC Page 48 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
3 For U-girder/I-girder/Pier-cap/Cross-Arm/Portal beam/T-girder/pie- MT 1,42,026.43 1,298.73
girder/L-girder etc.: Supplying and post tensioning uncoated stress-
relieved low relaxation steel conforming to IS :14268, class 2 from
approved supplier including providing corrugated HDPE sheathing
duct for cable system of 27K15, 19K15, 12K15, 7K15, 19K13, 12K13,
7K13 with couplers & vent pipes, spacers, anchorages, stressing using
grouting, recess filling, epoxy protection of anchorages and all
related operations to complete the work. (Note: the details shown
on the drawing may change and nothing extra will be paid to the
contractor on this account).
SHEDULE B4- Total Amount
SHEDULE B4- Total Amount
GMRC Page 49 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026
GMRC Page 50 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B5- STRUCTURAL STEEL
Item Description U nit Rate (excl. Quantity Amount (Rs.)
1 Fabrication, Supply & Erection of Steel Plate girder spans. Procurement and fabrication MT 1,44,480.88
of steel members for Steel Plate girder Bridge Work using structural steel plates
(conforming to IS-2062-Grade B0 E 410) & structural steel rolled section (conforming to
IS-2062-Grade B0 E 250) to the required profile and shape as called for including the
shear studs profiled from the rods and erection of fabricated girders at specified site
locations. This item includes preparation of fabrication shop drawings, necessary
templates, all cutting, welding (using automatic submerged arc welding), grinding & all
equipments and operations etc required to complete the job. This item also includes all
tests on materials and welded fabricated parts as required. This item also includes
application of sand blasting on materials, application of primer and various coats of
internal and external painting in fabrication shop and site as per technical specification
in chapter of structural steel. This item includes all necessary equipment required to
complete the job including procurement, testing and supply of HSFG bolts (class 8.8 and
above) and its compatible nuts and washers.
This item also include erection of the fabricated plate girder to the required profile and
shape as called for at designated site location including loading, transportation of all
structural steel members from fabrication shop to site and unloading; preparation of
erection scheme drawings, setting of storage yard at site if required & all equipment and
operation etc.required to complete the job. This item also includes temporary
support/staging, staging braces, bracing to permanent work, strutting, tying or anchor
bolts, fasteners, welding, temporary foundations required for erection. This item also
includes the field bolting at erection site as per specifications including all connections
required between steel plate girder and bearings.
The structural steel to be used shall be procured from the approved manufacturer as per
contract provision. For payment purpose, nominal weight of the girder as per drawing
will only be considered.
GMRC Page 51 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Payment Terms shall be as follow: -
1) 50% shall be paid on fabrication of truss/girder components after inspection and
2) 10% shall be paid on Primer and painting of truss/girder components after inspection -
3) 5% shall be paid on receipt of fabricated and painted truss/girder components at site. -
4) 30% shall be paid on erection of truss/girder components by bolts and drifs and fixing -
permanent fastner.
5) 5% shall be paid on completion of balance work. -
Note:- Only steel which is erected and part of permanent structure will be measured - -
Note:- Any additional temporary structure which will be required for erection / -
launching of fabricated part or complete plate girder and the provision of the
connection of the same to the permanent work by welding the same or making holes as
per the approved launching scheme will be done by tenderer. No payment will be made
for such operations.
2 Providing , fabricating and erecting structural steel for hand/safety railing and other MT 1,11,168.75 810.47
structural members for viaduct including transition span consisting of tubular and
rolled sections profiled to require shape, inserts, plates with welded hold fasts for walk-
way, earth terminal plates, insert plates with welded hold-fasts, internal threaded
sleeves including MS bolts tightened by Torque wrench and primer coat & three coats
of enamel paint of approved make and colour as per specification and drawing, with
all lead and lifts and as per the directions of engineer. The rate includes required
surface preparation (sand blasting).
Note: All structural steel shall be Hot Dip galvanized conforming to IS-802 (Part II ),
IS:5358 and IS:4759. and the mass of zinc coating shall not be less than 500 g/sq.m.
GMRC Page 52 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
3 Providing, fabricating and erecting structural steel inserts for cable tray, inserts for cable MT 1,11,168.75 425.93
ducts, inserts for signalling mast steel brackets over parapet for fixing street light,
earthing arrangement consisting of plates with welded hold fast, welded headed nuts,
internal threaded sleeve, studs in the form of U bars, bolts (class 4.6) etc..
Note: All structural steel shall be Hot Dip galvanized conforming to IS-802 (Part II ),
IS:53548 and IS:4759 and the mass of zinc coating shall not be less than 500 g/sq.m.
Note: Some inserts fabricated by other agencies which have to be incorporated in the
precast segments/ cast- in-situ spans /piers/ pile cap/pile would have to be handed over
to the contractor for placement and fixing in the reinforcement cage/ shuttering before
concreting. No extra paymet will be made for such inserts.
4 Providing, fabricating and Erection of structural steel Foot Over Bridge (FOB) as per MT 1,44,480.88 693.00
grade defined in drawing i.e. E250 BR and tube section YST 310 complete. This rate also
includes preparation of shop drawings procurement of raw materials sand blasting,
painting, trail assembly and all other activities.This item includes all necessary equipment
required to complete the job including procurement, testing and supply of HSFG bolts
(class 8.8 and above) and its compatible nuts and washers. This item is also applicable for
station box and entry/exit structure wherever required as per the direcction and apporval
of engineer incharge.
i) Procurement and testing of Steel Quantities=45%
ii) On Completion of Fabrication of Steel Wotrk=20%
iii) Transporation and receipt of Fabricated Material at Site=10%
iv) Final Erection of Pre-Engineered Steel=25%
SCHEDULE B5 - Total Amount
SCHEDULE B5 - Total Amount
GMRC Page 53 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B6 - BEARINGS
Item Description Unit Rate (excl. GST) Quantity Amount (Rs.)
1 Elastomeric bearings
Supply and fixing in position true in line & level, Elastomeric
bearings of approved make, placing and fixing in location as per
specification/ drawings and as directed by the Engineer in charge.
For elastomeric bearing below superstructure Cucm 0.54 43415317.48
For elastomeric bearing on sides of shear key stopper. It includes Cucm 0.54 104393.67
vertical bearing with Teflon for slider arrangement in Guided end
2 Supply, fabrication, and installation of MS Wedge Plates including KG 276.70 87715.18
cutting, welding, drilling, grinding and surface treatment as per
approved drawings and specifications.and Fixing of MS Wedge
Plate over Elastomeric Bearing for U-Girder.
3 Supplying to site lifting, installation, fixing and placing of POT - -
Cum PTFE Bearing and its components in position during
casting of Pier/Pedestal and superstructure, incl. grouting of
holes for anchor bolts and underside of base plate with
approved non-shrink cementitious grout (e.g. Conbextra GP2 or
equivalent) as per specification. The design of POT cum PTFE
bearings shall be done by contractor as per loads, movements
etc. given in good for construction (GFC) drawings.
GMRC Page 54 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
i) Free POT Bearing (Un-facored Design Vertical load = 1750 kN ) Nos 48,625.41 4.00
ii) Fixed POT Bearing (Un-facored DesignVertical load = 1750 Nos 40,275.43 4.00
kN and Un-facored Design Horizontal load =600 kN)
iii) Longitudinal Guide POT Bearing (Un-facored Design Nos 42,362.88 4.00
Vertical load = 1750 kN and Un-facored Design Horizontal load
iv) Transverse Guide POT Bearing (Un-facored Design Vertical Nos 41,316.23 4.00
load = 1750 kN and Un-facored Design Horizontal load =600
Note: Price holds good for forces and movements varying by ± 25% -
for those indicated.
4 Spherical bearings Nos. 1,05,360.2 4.00
(i) Providing, fitting and fixing in position true in line and level
Spherical bearings , complete in all respect with all components
incl grouting with non-shrink cementitious grout as per drawing
and technical specifications.
Total Number of Fixed Bearing Max Vertical load = 5600 kN and
Horizontal load =1670 kN
(ii) Total Number of Free Bearing Max Vertical load = 5600 kN Nos. 87,490.7 4.00
(iii) Total Number of Slide Guide Longitudinal Bearing Max Vertical Nos. 1,04,696.6 4.00
load = 5600 kN and Horizontal load =1670 kN
(iv) Total Number of Slide Guide Transeverse Bearing Max Vertical Nos. 93,614.4 4.00
load = 5600 kN and Horizontal load =1670 kN
SCHEDULE B6 Total Amount
SCHEDULE B6 Total Amount
GMRC Page 55 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B7- MISCELLANEOUS ITEMS
Item Description Unit Rate (excl. Quantity Amount (Rs.)
1 Drainage Work
(i) Providing & fixing of double wall HDPE corrugated/plain pipes and /or
UPVC pipes (only external if provided) as specified for rain water in
superstructure of all types and down take pipes, bends, couplers, upper
receiving cap, Tees and end cap etc. upto bottom of pier through
shear key as specified in drawings. This will be required to be also
provided at track crossing location for laying power cable.
(d) Upper receiving cap -( hot dipped galvanised @650 g/sqm steel) for nos 3,083.66 462.78
2 Expansion Joints - -
GMRC Page 56 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
(i) Omega seal joint / Compression seal Expansion Joint RM 4,677.75 3,753.62
Providing and installing Omega seal joint / Compression seal
Expansion Joint conforming to specification incl. provision of edge
beams at end edges of both adjoining precast diaphragm segments,
cast in situ units and all related operations as required to complete the
work as specified in specifications.
(ii) Strip Seal Joint – Providing and installing Single strip seal joint RM 9,045.00 132.06
conforming to latest revisions of MORTH circulars incl. provision of
edge beams at end edges of precast diaphragm segments and cast in
situ unit and all related operations as required to complete the work as
specified in specifications. Gap for expansion joint installation is upto
100mm & maximum variation in gap upto ± 50mm as per instruction of
engineer incharge.
3 Supply and fixing of 3mt x 0.855mm and 2.0mm thick FRP sheets to RM 2,133.86 1,584.70
cover the gap between the U-girders as per approved drawings and
direction of Engineer-in-charge. This rate includes Material, Labour and
required machinery.
4 Making of Cutouts (Core Cutting) in pre constructed RCC / CC for all
grades / Block / Brick works for services required.
4.1 50 mm dia upto 250rnm long Nos 3,645.00 25.00
4.2 100 mm dia upto 250rnm long Nos 4,253.00 25.00
4.3 250 mm dia upto 250rnm long Nos 4,678.00 25.00
GMRC Page 57 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
4.4 150 mm dia upto 250rnm long Nos 5,164.00 25.00
4.5 200 mm dia upto 250rnm long Nos 5,468.00 25.00
5 Rebaring as per below per below details
5.1 10mm dia. Rebar Fixing in 12mm dia. with hole depth of 6" Nos 224.26 150.00
5.2 12mm dia. Rebar Fixing in 14mm dia. with hole depth of 6" Nos 579.00 150.00
5.3 16mm dia. Rebar Fixing in 20mm dia. with hole depth of 6" Nos 914.37 150.00
5.4 20mm dia. Rebar Fixing in 25mm dia. with hole depth of 6" Nos 1,058.75 150.00
5.5 25mm dia. Rebar Fixing in 30mm dia. with hole depth of 6" Nos 1,469.00 150.00
5.6 32mm dia. Rebar Fixing in 38mm dia. with hole depth of 6" Nos 1,653.00 150.00
6 Providing and fixing of cable support GI bracket (Hot Dip Galvanized as Kg 121.50 1,000.00
per drawing for laying of system cables in the platform area at
elevated station. The rate shall include cost of all required materials,
Hot Dip Galvanized , fabrication, transportation at site, fasteners and
fixing in viaduct holes already provided by Civil contractor for cable
fixing/tieing, complete job in terms of approved drawings and as per
direction of Engineer-in-charge.(Cost of Fasteners paid Separately)
GMRC Page 58 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
7 Providing, fabricating, supplying, and fixing lifting hook arrangement in Nos 3,378.66 7.00
ASS (Auxiliary Sub-Station) / TSS (Traction Sub-Station) room for
lifting and maintenance of equipment such as transformers, panels, or
other heavy electrical equipment, including hook, anchoring system,
fixing arrangement, and all associated works, complete as per
approved drawings and instructions of the Engineer.
8 Providing and applying two-component polysulphide sealant in RM 569.00 500.00
construction/expansion joints of concrete, masonry, metal, glass or
other surfaces, including joint preparation, primer application, backing
rod where required, sealant application and finishing, complete in all
respects as per approved drawings, manufacturer’s specifications and
instructions of the Engineer.
9 Providing, casting, supplying, transporting and erecting precast Sqmt 2,235.60 1,000.00
reinforced cement concrete (RCC) boundary wall panels with RCC
posts, including excavation, foundation, erection, fixing of panels,
jointing, finishing and all associated works, complete in all respects as
per approved drawings and instructions of the Engineer.
GMRC Page 59 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
10 Providing, Installing and fixing in position holding down bolts of various MT 1,52,741.00 7.00
sizes and lengths, as per drawings and instructions, including making of
pockets in foundations, column heads, beams et. / Providing,
fabricating to required profile and shape, transporting, erecting and
fixing in position MS members made of built-up sections/ rolled or
hollow structural steel sections to be used as fixtures/supports/hangers
etc. for system/roofing contractors at any location or as directed by
Engineer in charge. Providing, fabricating, installing and fixing in
position any additional structural connections for signages, gutters, or
required by the system contractors using standard plate sections
welded & built up section, tubes, square, rectangular pipe section,
rolled sections such as angles, channels etc.
11.0 Masonry Work
11.1 Providing & laying Autoclaved Aerated Cement Blocks masonry with Cum 6781 5068
100mm/150mm/200mm/300mm thick AAC blocks in all levels with
RCC band at sill level and lintel level with approved block laying
polymer modified adhesive mortar all complete as per direction of
Engineer-in-Charge. (The payment of RCC band and reinforcement shall
be made for seperately).
11.2 Providing and laying Damp-proof course 40 mm thick with cement Sqm 366 171.5
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
12.5 mm nominal size).
GMRC Page 60 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
11.3 Reinforced cement concrete work in beams, suspended floors, roofs Cum 10238 491.75
having slope up to 15° landings, balconies, shelves, chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases up to floor
five level excluding the cost of centering, shuttering, finishing and
reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).
11.4 Centering and shuttering including strutting, propping etc. and -
removal of form for all heights :
11.4.1 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 656 5106.5
11.5 Brick work with common burnt clay F.P.S. (non modular) bricks of class -
designation 7.5 in foundation and plinth in:
11.5.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 6347 71.75
11.6 Brick work with common burnt clay F.P.S. (non modular) bricks of class -
designation 7.5 in superstructure above plinth level up to floor V level
in all shapes and sizes in :
11.6.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 8103 73.5
11.7 Half brick masonry with F.P.S. brick of class designation 75 in -
foundations and plinth in.
11.7.1 Cement mortar 1:3 (1 cement : 3 coarse sand) sqm 830 71.75
GMRC Page 61 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
11.8 Half brick masonry with F.P.S. bricks of class designation 75 in -
superstructure above plinth level up to floor V level.
11.8.1 Cement mortar 1:3 (1 cement :3 coarse sand) sqm 1024 71.75
11.9 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at sqm 94 143.5
every third course of half brick masonry
11.10 Providing and laying in position cement concrete of specified grade -
excluding the cost of centering and shuttering - All work up to plinth
11.10.1 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: cum 7011 71.75
4 graded stone aggregate 20 mm nominal size derived from natural
11.11 Providing and laying in position ready mixed or site batched design -
mix cement concrete for plain cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting
of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering, shuttering
and finishing as per direction of the engineer-in-charge; for the
following grades of concrete.
GMRC Page 62 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Note: Extra cement up to 10% of the minimum specified cement -
content in design mix shall be payable separately. In case the cement
content in design mix is more than 110% of the minimum specified
cement content, the contractor shall have discretion to either re-design
the mix or bear the cost of extra cement.
11.11.1 All works above plinth and upto floor V level -
a) Concrete of M10 grade with minimum cement content of 220 kg /cum cum 8179 36.75
b) Concrete of M15 grade with minimum cement content of 240 kg /cum cum 8313 36.75
11.12 Providing and fixing up to floor five level precast cement concrete -
block, including hoisting and setting in position with cement mortar
1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering
11.12.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural cum 15919 357
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources).
12 Plaster works -
12.1 12mm cement plaster of mix: -
12.1.1 1:6 (1 cement : 6 fine sand). (at all levels and locations) Sqm 297 47402.25
12.2 15 mm cement plaster on rough side of single or half brick work wall of -
GMRC Page 63 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
12.2.1 1:4 (1 cement : 4 fine sand) (at all levels and locations) Sqm 356 18735.5
12.3 6 mm cement plaster of mix : -
12.3.1 1:3 (1 cement: 3 fine sand) (at all levels and locations) Sqm 268 40398.75
13 Providing & fixing G.I. Hexagonal chicken wire mesh of size 12mm x 20 Sqm 31.50 24,948.00
gauge conforming to IS : 3150 at the junction of dissimilar surfaces of
brick / block masonry wall and RCC column / beams and the like
including necessary "U" nails / screws with cleats for fixing, overlapping
etc. complete all as per specification and as directed by the Engineer
for all height and all locations.
Schedule B7 - Total Amount
Schedule B7 - Total Amount
GMRC Page 64 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule B8 - Structural Steel for Open Web Girder
Item Description Unit Rate (excl. Quantity Amount
1 Supply and Fabrication of steel through type TRUSS spans as per the approved MT
drawings of superstructure with contractor's own structural steel plates 1,81,543.22 1,489.40
(conforming to IS-2062-Grade B0 E 410) & structural steel rolled section
(conforming to IS-2062-Grade B0 E 250) quality with all welds, rivets, nuts bolts,
etc. with contractor's own materials, fabrication, machinery, templates, fixtures,
equipment, tools and plants, transportation, skilled/unskilled labour, all leads and
lifts, Descent, loading, unloading, crossing one or more Railway track if required,
etc. complete and as per RDSO drawings & specifications by RDSO approved
venders only.The work shall be carried out during block periods sanction by
railway. No extra payment shall be made on this account.
The rate is inclusive of transportation of fabricated truss parts to site by
contractor's own means at his cost.
The structural steel to be used shall be procured from the Railway/RDSO approved
manufacturer only. Work has to be done as per drawings and specifications
approved by Railway.
1) The fabrication of truss must be got done from RDSO approved firms only.
2) For payment purpose, nominal weight of the truss as per drawing will only be
Metalising TRUSS components such as cross girders, top chord channels, bracing
etc. as directed by Engineer with aluminium spray not less than two layers after
preparing surface by sand/grit blasting as per provision laid in Appendix VI of IRS B
1 code (latest alteration) including one coat wash primer (IS-5666) one coat zinc
chrome primer (IS-104) and two coats of aluminium paint (IS-2339) with approved
paint conforming to IS specification for fabrication and erection of steel girder
bridge (IRS B 1) with Contractor's own materials, tools and plants, labour, loading,
unloading, transportation, handling, re-handling if any, including all lead, lifts,
Descents, crossing of track/obstruction etc. complete in all respect and as per
direction of the Engineer.
GMRC Page 65 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Assembling, Welding, Erecting, Riveting, Launching, bolting by HSFG bolts(class
grade and above) wherever required (as per approved drawings) with contractor's
rivet materials, weld materials, HSFG bolts, service bolts, erection and launching of
Truss span to Railway's approved drawings with other ancillary steel structures
fixed to the truss where necessary in proper level and alignment and as per
technical specifications. The cost includes cost of launching steel nose/ launching
steel girder of required length.
Schedule B8 - Total Amount
Schedule B8 - Total Amount
GMRC Page 66 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Schedule C1 - Electrical System Works
S.No Description of Item Unit Rate QUANTITY Amount
SWITCH BOARDS/PANELS
Design, Fabrication, Assembling, Wiring, Supply, installation, testing & commissioning
of LT Panels fabricated out of CRCA sheet steel 2 mm thick for structural members
and 1.6 mm thick for doors and covers in cubical compartmentalized free standing
floor mounted, dust and vermin proof with reinforcement of suitable size ISA / ISMC
/ ISMB / flats wherever necessary. Panels shall be treated with all anticorrosive
process and powder coated (Minimum thickness 80 micron) with approved shade.
Panels shall be suitable for 415V, 3 phase, 4 wire, 50 Hz power supply system to
withstand rated symmetrical fault level at 415 V including interconnections, bonding
to earth etc. Panels shall be provided with 25% spare space, space heaters,
compartmental lights, lifting hooks as required and 2 Nos of Earthing Terminals. All
inter wiring shall be with suitable stranded copper conductor FRLSH insulated wire.
The panels shall confirm to IP-54. Galvanized hardwares with Zinc passivation shall be
a The Electrical Panels shall be a minimum of Form 4b type Type 5 in accordance
with BS EN61439-1/IEC 61439-2 . Internal arc test as per IEC 61641 complete as per
b The panels shall be provided with detachable gland plates of 3mm thickness for
entry of cables from the top/bottom as required.
c All live accessible parts shall be shrouded and all equipment shall be finger touch
proof. SMC/DMC shrouds and busbars supports shall be suitably spaced.
d The panel shall have tinned copper busbars with bar type feeder connections,
spacers etc.and neutral busbar shall be of 100% capacity. Bus Bar Sizing calculations
shall be submitted for approval of GMRCL Engineer.
e All components shall be connected to a common internal copper earth bus bar of
minimum size 50mm x 6mm.
GMRC Page 67 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
g Hinged doors with Neoprene type gaskets & Triangle key lock facility shall be
provided on Doors and all outgoing feeders with switch handles lockable in OFF
h Each incomer and outgoing feeder shall be provided with suitably rated MCB
controlled multiple LED lamps (Red, Yellow, Blue) for Phase indication and (Red,
Green, Amber) for ON, OFF & Trip status with all required accessories suitable for
230 VAC operation as approved.
j The makes of components and accessories shall be unique for all the panels under
this contract in order to have uniformity and standardization.
k All MCCBs shall be current limiting type microprocessor based releases having
continuously adjustable current setting in the range of 0.4 to 1.0 and 2-10 times of
short circuit, rated for requisite specified Service short circuit breaking capacity (Ics)
suitable for isolation conforming to latest IS/IEC60947-2 duly marked on MCCB, at
operating voltage (Ue) of 415 V, insulation voltage (Ui) 1100 V and with trip free
mechanism, handle indicating ON/OFF/tripped position. The breaking capacity as
mentioned in items of BOQ below. Breakers must have Ics = Icu = Icw.
l All MCCB's shall be 4 pole with Over Load Protection,Short circuit and Earth Fault
sensing. MCCBs shall be suitably designed to provide protection of motors, cables,
busbars to suit rated current, unbalanced power distribution as required and with
front adjustable overload and short circuit releases and minimum electrical
endurance shall be of the order of suitable operation cycles as specified in the
Technical Specification.All MCCBs shall be provided with Rotary handle and spreader
links for termination. All 4P MCCB has inbuilt feature of earth fault protection,
whereas all TPN MCCB's (Expect Motor Starters & DRPC Panels) shall have external
CT for neutral overload protection and earth fault protection
m All the Incomer, bus couplers of switch boards/ panels shall be provided with
potential free contacts for connectivity to PLC for ON/OFF status and control, as
required for BMS .All Incomer, bus couplers of switch boards/ panels shall be
provided with Multi function Meters with RS 485 for BMS connectivity. All the RS -
485 devices of Panels/ DBs shall be looped into a single terminal/ port for each
panels for easy integrations with BMS. All internal Wiring & required accessories are
in scope of Panel/ DB Vendor.
GMRC Page 68 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
n MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 10 kA at
415 V AC, current limiting type lower power loss appx 40 - 70% of the stipulated
value and suitable for magnetic releases operating between 3 to 5 times rated
current for normal power distribution application and 5 to 10 times rated current for
motor application duty, with minimum Electrical endurance of the order of
operation cycles. All MCCBs shall be provided with Rotary handle and spreader links
for termination complete as required.
o Panel design shall be compact to economies the room space available.
p All incomer ACB's shall be provided with minimum 6 NO + 6 NC contacts and there
should be provision to add min. 6 NO+ 6 NC Auxiliary contacts.
q All 4-pole ACBs, MCCBs & MCBs shall have fully rated neutral pole.
r The panels shall be provided with polymer based fire trace tube system. Scheme of
fire trace tube system shall be got approved by GMRCL Engineer before proceeding
with manufacturing and assembly. Cost for this item shall be paid under suitable Item
of Fire fighting works. Contractor shall interface with OEM of panel and Panel
flooding system and ensure that the provision is made during fabrication of panel
s Internal control wiring in the Starters shall be done with FRLSH PVC insulated cables
of adequate size. Internal wiring, contactors, relay contacts, push button contacts
should be rated not less than 2.5 sq. mm. All MCCB shall be motorized with RS
type communication port for BMS/SCADA functioning.
u Switch boards / panels shall be provided with Automatic clean agent gas flooding
arrangement with a fire detection tube system, as per the specifications complying
with the latest Indian Standards (IS:15517) and NFPA-2001. An Automatic gas
flooding system shall be provided with manual overriding system with regulated
valve arrangement including control & Monitoring module for opening or closing the
cylinder as and when it is called for. A bank of clean agent gas cylinders with
necessary tubing shall be provided.
v Each Panel/DB as required shall be capable of real-time data of Status, Control &
Monitoring through Ethernet/TCP IP Port / RS 485 through open protocol (IEC 60870-
5104 shall be preferred),
GMRC Page 69 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
w The Digital Multifunction meter shall have inbuilt bar graph for showing the
percentage loading in each phase and inbuilt LCD display to show all the power
parameters like A, V, W, VAR, VA, Wh, Vah, VARh & Hz. with BMS connectivity.
x All motorized MCCBs /ASTS MCCBs to be provided with 230V, 50Hz control supply as
required including conversion needed if any from UPS DB.
y The schematic drawings are to be read in conjunction with BOQ & Technical
specifications.
z The load demand, cable size and route length are indicative only and contractor shall
evaluate the adequacy of the switch gear and voltage drop norms.
aa All switch boards/ panels shall be provided with necessary Surge Protection for
Transient Over Voltages due to Lightning and switching surges shall be incorporated
with suitable rating Surge Arresters under Class-1, Class-2, Class-3 of IEC
ab The bus bar shall be designed for all the switch boards / panels meeting application
duty requirement provided with insulations/ bus bar supports system withstanding
the thermo dynamic stresses
ac All panel shall have IP 54 protection for indoor application and IP 65 for outdoor
ad Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
1.1 MAIN DISTRIBUTION BOARD (MDB)
A Transformer - I Incoming
GMRC Page 70 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
1 No. of 1000 A, 415V, 50kA, 4P Electrically operated (fully motorized) fully draw out
(EODO) type ACB with built in Microprocessor based release unit for Over Current,
Short circuit and earth fault protection with adjustable setting and time log facility
for each of the fault for achieving discrimination along with distinct fault indication
through LED display. ACB shall be provided with continuous rated shunt trip release
suitable for 240 VAC operation, suitable handles to operate ACB manually and spring
charging device suitable for 1 phase, 240 VAC operation, NO/NC contacts for
interlocks and indications. ACB shall have in-built compatibility through open
protocol like Modbus for SCADA/BMS connectivity (RS485) along with following
i) 1 No. of Multi Function Meter of accuracy class 1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards
with necessary Circuit MCBs and suitable size summating CTs for metering
supporting SCADA/BMS connectivity
ii) 1 No. 0-1000A Digital Ammeter with selector switch and Required set of CTs, MCBs
and Accessories
iii) 1 No. 0-500V Digital Voltmeter with selector switch and Required set of MCBs and
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15 VA Burden & Class
5P10 for protection
vii) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15VA burden and Class
1 for measurement
viii) 3 nos. cast resin current transformers of 1000/5 ratio with 15VA burden and Class
ix) 1 set of Under Voltage Relay with complete accessories.
x) 1 set of Over Voltage Relay with complete accessories.
xi) 1 set of Instantaneous Over Currrent Relay (50)
GMRC Page 71 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
xii) 1 set of IDMT Over Current Relay (51)
xiii) 1 set of Earth Fault protection relay (51N)
xiv) 1 set of Ground fault protection relay (50N)
xv) 1 set of reverse power protection and phase sequence protection
xvi) Auxiliary contacts required for necessary interlocking of Transformers, HT & LT
xvii) Class-B SPDs shall be provided in panel as per IEC 61643-12 or latest.
xviii) Contractor shall provide earmarked potential free terminals for SCADA signals as per
specification & requirements.
B Transformer - II Incoming
1 No. of 1000 A, 415V, 50kA, 4P Electrically operated (fully motorized) fully draw out
(EODO) type ACB with built in Microprocessor based release unit for Over Current,
Short circuit and earth fault protection with adjustable setting and time log facility
for each of the fault for achieving discrimination along with distinct fault indication
through LED display. ACB shall be provided with continuous rated shunt trip release
suitable for 240 VAC operation, suitable handles to operate ACB manually and spring
charging device suitable for 1 phase, 240 VAC operation, NO/NC contacts for
interlocks and indications. ACB shall have in-built compatibility through open
protocol like Modbus for SCADA/BMS connectivity (RS485) along with following
i) 1 No. of Multi Function Meter of accuracy class 1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards
with necessary Circuit MCBs and suitable size summating CTs for metering
supporting SCADA/BMS connectivity
ii) 1 No. 0-1000A Digital Ammeter with selector switch and Required set of CTs, MCBs
and Accessories
iii) 1 No. 0-500V Digital Voltmeter with selector switch and Required set of MCBs and
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
GMRC Page 72 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15 VA Burden & Class
P10 for protection
vii) 3 Nos. of cast resin current transformers of 1000/5 ratio with 15VA burden and Class
1 for measurement
viii) 3 nos. cast resin current transformers of 1000/5 ratio with 15VA burden and Class
for APFC relay /AHF.
ix) 1 set of Under Voltage Relay with complete accessories.
x) 1 set of Over Voltage Relay with complete accessories.
xi) 1 set of Instantaneous Over Currrent Relay (50)
xii) 1 set of IDMT Over Current Relay (51)
xiii) 1 set of Earth Fault protection relay (51N)
xiv) 1 set of Ground fault protection relay (50N)
xv) 1 set of reverse power protection and phase sequence protection
xvi) Auxiliary contacts required for necessary interlocking of Transformers, HT & LT
xvii) Class-B SPDs shall be provided in panel as per IEC 61643-12 or latest.
xviii) Contractor shall provide earmarked potential free terminals for SCADA signals as per
specification & requirements.
1 No. of 1000 A, 415V, 50kA, 4P draw out Electrically operated (fully motorized) fully
draw out (EODO) type ACB with built in Microprocessor based release unit for Over
Current, Short circuit and earth fault protection with adjustable setting and time log
facility for each of the fault for achieving discrimination along with distinct fault
indication through LED display. ACB shall be provided with continuous rated shunt
trip release suitable for 240 VAC operation, suitable handles to operate ACB
manually and spring charging device suitable for 1 phase, 240 VAC operation, NO/NC
contacts for interlocks and indications. ACB shall have in-built compatibility through
open protocol like Modbus for SCADA/BMS connectivity (RS485) along with following
GMRC Page 73 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
i) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps and ON/OFF push
ii) Auxiliary contacts required for necessary interlocking of Transformers, HT<
iii) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
iv) Two incomers shall be interlocked electrically & mechanically, so as only any 02 out
of 03 ACBs can be closed at any time.
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>1000 A as per specification, suitable to withstand symmetrical fault level of 50 kA at
415 V with 100% rated neutral busbar.
a) 1 nos. 400A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent, short circuit
and earth fault releases & each having 1- set Red/Green ON/OFF indicating lamps, &
3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden & Class
for Ammeter with Ammeter selector Switch.
b) 3 nos. 250A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent, short circuit
and earth fault releases & each having 1- set Red/Green ON/OFF indicating lamps, &
3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden & Class
for Ammeter with Ammeter selector Switch .
c) 3 nos. 160A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent, short
circuit, and earth fault releases & each having 1- set Red/Green ON/OFF indicating
lamps, 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden &
Class 1.0 for Ammeter with Ammeter selector Switch.
d) 1 nos. 100A, 415V, Ics=35 kA, Four Pole MCCB with variable overcurrent, short
circuit and earth fault releases & each having 1- set Red/Green ON/OFF indicating
lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden &
Class 1.0 for Ammeter with Ammeter selector Switch
GMRC Page 74 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
a) 2 nos. 400A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent, short circuit
and earth fault releases & each having 1- set Red/Green ON/OFF indicating lamps &
nos. cast resin current transformers of 400/5 ratio with 15 VA Burden & Class 1.0 for
Ammeter with Ammeter selector Switch.
b) 3 nos. 160A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent, short circuit
and earth fault releases & each having 1- set Red/Green ON/OFF indicating lamps &
nos. cast resin current transformers of 160/5 ratio with 15 VA Burden & Class 1.0 for
Ammeter with Ammeter selector Switch.
c) 3 nos. 250A, 415V, Ics=35kA, Four pole MCCB with variable overcurrent, short circuit
and earth fault releases & each having 1- set Red/Green ON/OFF indicating lamps &
nos. cast resin current transformers of 250/5 ratio with 15 VA Burden & Class 1.0 for
Ammeter with Ammeter selector Switch.
d) 2 nos. 100A, 415V, Ics=35 kA, Four pole MCCB with variable overcurrent, short circuit
and earth fault releases & each having 1- set Red/Green ON/OFF indicating lamps &
nos. cast resin current transformers of 100/5 ratio with 15 VA Burden & Class 1.0 for
Ammeter with Ammeter selector Switch.
SITC of MAIN DISTRIBUTION BOARD (MDB) No.
1.2 Emergency Main Distribution Board (EMDB)
A Incomer (Normal supply)
a) Incoming from B1 with 400A, 415V , Ics = 35kA, FP, Motorised MCCB complete with
variable overcurrent ans short circuit releases for Normal supply.
b) Incoming from B2 with 400A, 415V , Ics = 35kA, FP, Motorised MCCB complete with
variable overcurrent ans short circuit releases for Normal supply.
c) Automatic changeover system complete
GMRC Page 75 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
B INCOMING FROM DG PANEL
a) 1 no. 400A, 415V , Ics = 35kA, FP, Motorised MCCB complete with variable
overcurrent ans short circuit and short circuit releases for Normal supply.
b) Automatic changeover system complete
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
> 400 A as per specification, suitable to withstand symmetrical fault level of 35 kA at
415 V with 100% rated neutral busbar.
a) All incomers shall be interlocked electrically & mechanically with contactor based
automatic changeover system so that only one supply is switched on at a time and
fail safe restoration.
D Outgoing Units
a) 4 nos. 125 A, 415V, Ics=35 kA, TPN MCCB with fixed neutral and variable
overcurrent, short circuit and earth fault releases with 1 set each of MCB controlled
Breaker ON/OFF/TRIP and phase indicating lamps.
b) 2 no. 200 A, 415V, Ics=35 kA, TPN MCCB with fixed neutral and and variable
overcurrent, short circuit and earth fault releases with 1 set each of MCB controlled
Breaker ON/OFF/TRIP and phase indicating lamps.
c) 12 no. 63 A, 415V, Ics=25 kA, TPN MCCB with fixed neutral and and variable
overcurrent, short circuit and earth fault releases with 1 set each of MCB controlled
Breaker ON/OFF/TRIP and phase indicating lamps.
GMRC Page 76 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
1 No, 230V, AC operated integral type Digital meter with RS485 port for measuring
Amps ,Voltage, Energy, kWH, kVAR, frequency, Maximum Demand & power factor
etc conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with
necessary Circuit MCBs and suitable size summating CTs for above incomers
metering supporting SCADA/BMS connectivity.To be equipped with source power
sensing, automatic changeover, 3-phase Under-voltage protection, Phase Sequence
Protection and test facility inbuilt in the controller and RS 485 communication port
with compatibility for interfacing with BMS/SCADA. The trip unit of MCCB shall be
with adjustable Overload protection, Short Circuit protection, shunt trip coil, auxiliary
contacts for ON, OFF, TRIP indication etc. as per drawing and specifications along
with 3 sets of following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
ii) 1 No. 0-400A Digital Ammeter with selector switch and Required set of CTs, MCBs
and Accessories
iii) 1 No. 0-500V Digital Voltmeter with selector switch and Required set of MCBs and
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Auxiliary contacts required for necessary interlocking of breakers.
vii) 3 Nos. of cast resin current transformers of 400/5 ratio with 15VA burden and Class
1 for measurement.
viii) Class-B, SPDs shall be provided in panel as per IEC 61643-12 or latest.
ix) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
SITC of Emergency Main Distribution Board (EMDB) No.
GMRC Page 77 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
1.3 Design, Supply, installation, testing commissioning of Main Lighting & Power panel
(MLPP) complete as per specifications & Drawing with following:
Main Lighting & Power panel (MLPP)
A Incomer (from MDB-1)
2 No. of 100 A, 415V, 25kA, 4P MCCB with changeover switch built in
Microprocessor based release unit for Over Current, Short circuit and earth fault
protection with adjustable settings. The breaking capacity of MCCB shall be Icw=Icu.
MCCB shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) along with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
MFM shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
iii) 1 set of MCB controlled phase indicating lamps for all three phases.
iv) Amber healthy trip indicating lamps
v) 3 Nos. of cast resin current transformers of 100/5 ratio with 15VA burden and Class
1.0 for measurement
vi) Auxiliary contacts required for necessary interlocking.
vii) Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
viii) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
GMRC Page 78 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>100 A as per specification, suitable to withstand symmetrical fault level of 25 kA at
415 V with 100% rated neutral busbar.
a) 9 Nos. of 10A/20A , 415V, 10kA, TPN MCB, with fixed neutral and variable
overcurrent, short circuit releases. Suitably rated AC3 Duty power contactor of with
necessary NO & NC auxiliary contacts as required for operation through BMS, Auto/
manual selector switch, 1 set of MCB controlled Breaker ON/OFF/TRIP indicating
lamps, complete as required and approved.
SITC of Main Lighting & Power panel (MLPP) No.
1.4 Design, Supply, installation, testing commissioning of Emergency (UPS) Power
panel complete as per specifications & Drawing with following:
Emergency (UPS) Power panel (UPP)
a) 2 Nos. of 63 A, 415V, 25kA, 4P MCCB with built in Microprocessor based release unit
for Over Current, Short circuit and earth fault protection with adjustable settings.
The breaking capacity of MCCB shall be Icw=Icu. MCCB shall have in built
compatibility through open protocol like Modbus for SCADA/BMS connectivity
(RS485) each along with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
MFM shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) 3 Nos. of cast resin current transformers of 40/5 ratio with 15VA burden and Class
1.0 for measurement
iii) Auxiliary contacts required for necessary interlocking.
GMRC Page 79 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
iv) Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
v) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
vi) 1 set of MCB controlled phase indicating lamps for all three phases.
vii) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>63 A as per specification, suitable to withstand symmetrical fault level of 25 kA at
415 V with 100% rated neutral busbar.
a) 11 Nos. of 20A, 230V, 10kA, DP MCB, with fixed neutral and variable overcurrent &
short circuit releases. Suitably rated AC3 Duty power contactor of with necessary NO
& NC auxiliary contacts as required for operation through BMS, Auto / manual
selector switch, 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps,
complete as required and approved.
b) 4 Nos. of 10A, 230V, 10kA, DP MCB, with fixed neutral and variable overcurrent &
short circuit releases. Suitably rated AC3 Duty power contactor of with necessary NO
& NC auxiliary contacts as required for operation through BMS, Auto / manual
selector switch, 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps,
complete as required and approved.
c) 3 Nos. of 20A, 230V, 10kA, DP MCB, with fixed neutral and variable overcurrent &
short circuit releases. Suitably rated AC3 Duty power contactor of with necessary NO
& NC auxiliary contacts as required for operation through BMS, Auto / manual
selector switch, 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps,
complete as required and approved.
SITC of Emergency (UPS) Power panel (EPP) No.
GMRC Page 80 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
1.5 Design, Supply, installation, testing commissioning of Fire & Water Pump Panel
(FWP) complete as per specifications, Drawings and as per following details:
1.5.1 Fire & Water Pump Panel (FWP)
a) 2 Nos. 200A, 35 kA, 4 pole, motorized MCCBs with automatic changeover system
with source power sensing with provision for receiving two independent source
power supply (one incoming supply from EMDB and one incoming supply from DG-
AMF panel) , electrically and mechanically interlocked with common base frame and
controller having selector switch for automatic & manual operation on both the
sources., 3 phase Under - voltage protection and Phase Sequence Protection inbuilt
in the controller and RS 485 communication port with compatibility for interfacing
with BMS/SCADA. The trip unit of MCCB shall be with adjustable Overload
protection, Short Circuit protection, shunt trip coil, auxiliary contacts for ON, OFF,
TRIP indication etc. as per drawing and specifications each along with following.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
ii) 3 Nos. of cast resin current transformers of 200/5 ratio with 15VA burden and Class
1.0 for measurement
iii) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
iv) 1 set of MCB controlled phase indicating lamps for all three phases.
v) Auxiliary contacts required for necessary interlocking of breakers.
vi) Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
vii) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
GMRC Page 81 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
a) Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>200A as per specification, suitable with stand symmetrical fault level of 35kA at
V. The neutral busbar is to be of capacity as phases
a) 3 nos. 160 A, Ics=25 kA, 415 V, TPN MCCB with fixed neutral and with variable
overcurrent and short circuit releases.
a1) 3 nos. Star‐Delta starter of Suitable rating comprising 3 Nos. TP contactor AC‐3 duty
Auto/Manual switch, timer, Start Stop push button, & with potential free contacts for
remote monitoring and control having the following item for each.
i) 1 No. of AC operated, 4 Digit, independent Digital Ammeter with selector switch
with necessary Circuit MCBs and with suitable size, 1 Class CTs connections as
required for outcoming feeders
ii) 1 set of start stop push buttons with inbuilt ON/OFF indicating lamps.
iii) Auto / Manual selector switch.
iv) Amber healthy trip indicating lamps.
b) 5 no. 20A, Ics= 10 kA, 415 V, TP N MCB with fixed neutral and with variable
overcurrent and short circuit releases.
b1) 2 KW DOL Starter (2 No Sump pumps), Star‐Delta starters of Suitable rating (2 Nos.
Domestic water pumps), Star‐Delta starters of Suitable rating (1 no jockey pump)
with potential free contacts for remote monitoring and control, having the following
items for each:
i) 1 No. of AC operated, 4 Digit, independent Digital Ammeter with selector switch
with necessary Circuit MCBs and with suitable size, 1 Class CTs connections as
required for outcoming feeders
ii) 1 set of start stop push buttons with inbuilt ON/OFF indicating lamps.
iii) Auto / Manual selector switch.
iv) Amber healthy trip indicating lamps
GMRC Page 82 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
c) 4 no. 20 A, Ics= 25 kA, 415 V, TP N MCB with fixed neutral and with variable
overcurrent and short circuit releases.
c1) 3.5 KW Star-Delta Starter (2 No Borewell pump)with potential free contacts for
remote monitoring and control. having the following item for each
i) 1 No. of AC operated, 4 Digit, independent Digital Ammeter with selector switch
with necessary Circuit MCBs and with suitable size, 1 Class CTs connections as
required for outcoming feeders
ii) 1 set of start stop push buttons with inbuilt ON/OFF indicating lamps.
iii) Auto / Manual selector switch.
iv) Amber healthy trip indicating lamps
D Auxiliary relay shall be provided which shall be activated by pressure switch for
remote monitoring.
SITC of Fire & Water Pump Panel (FWP) No.
1.6 Design, Supply, installation, testing commissioning of Escalator Power Panel (ESPP)
complete as per specifications, Drawing and as per following details:
1.6.1 Escalator Power Panel (ESPP)
a) 2 No. of 250 A, 415V, 35kA, 4P MCCB with changeover switch with E/M interlocking
built in Microprocessor based release unit for Over Current, Short circuit and earth
fault protection with adjustable settings.The breaking capacity of MCCB shall be
Icw=Icu. MCCB shall have in built compatibility through open protocol like Modbus
for SCADA/BMS connectivity (RS485) along with following accessories.
i) 1 No. of Multi Function Meter with all required to measure and display the Electrical
quantities like, Current, Voltage, Active Energy-KWH, Reactive Energy-kVAH,
frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion & power factor
etc. with facility conforming to specifications and latest IEC standards. MFM shall
have in built compatibility through open protocol like Modbus for SCADA/BMS
connectivity (RS485) and all required accessories.
GMRC Page 83 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
vii) 3 Nos. of cast resin current transformers of 250/5 ratio with 15VA burden and Class
1.0 for measurement
ii) Auxiliary contacts required for necessary interlocking.
iii) Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>250 A as per specification, suitable to withstand symmetrical fault level of 35 kA at
415 V with 100% rated neutral busbar.
a) 8 Nos. of 63A, 415V, 25kA, TPN MCCB, with fixed neutral and variable overcurrent &
short circuit releases. Suitably rated AC3 Duty power contactor of with necessary NO
& NC auxiliary contacts as required for operation through BMS, Auto / manual
selector switch, 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps,
complete as required and approved.
SITC of Escalator Power Panel (ESPP) No.
1.7 Design, Supply, installation, testing commissioning of Commercial Power Panel
(CPP) complete as per specification, Drawing and as per following details:
1.7.1 Commercial Power Panel (CPP)
GMRC Page 84 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
2 No. of 160 A, 415V, 25kA, 4P MCCB with changeover switch built in
Microprocessor based release unit for Over Current, Short circuit and earth fault
protection with adjustable settings. The breaking capacity of MCCB shall be Icw=Icu.
MCCB shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) along with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
MFM shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
vii) 3 Nos. of cast resin current transformers of 160/5 ratio with 15VA burden and Class
1.0 for measurement
ii) Auxiliary contacts required for necessary interlocking.
iii) Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>160 A as per specification, suitable with stand symmetrical fault level of 25kA at
415 V. The neutral busbar is to be of same capacity as phases.
a) 1 no. 125 A Ics=15 kA, 415V, 1 No. KWH meter & TPN MCCB C-Curve each having
indication lamps to give ON/OFF/TRIP status.
b) 2 nos. 63 A Ics=15 kA, 415V, 1 No. KWH meter & TPN MCCB C-Curve each having
indication lamps to give ON/OFF/TRIP status.
GMRC Page 85 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
C) 2 nos.32A Ics=10 kA, 230V, 1 No. KWH meter & DP MCB C-Curve each having
indication lamps to give ON/OFF/TRIP status.
d) 7 nos. 20A Ics=10 kA, 230V, 1 No. KWH meter & DP MCB C-Curve each having
indication lamps to give ON/OFF/TRIP status.
a) 1 No. in each outgoing, Electronic Energy Meter with RS-485 port for measuring
Current, Voltage Active and reactive Energy, Maximum Demand & Power factor etc.
with TOD facility with suitable size of CT's for each of the outgoing feeder with
locking arrangement.
b) 1 no. in each outgoing, KWH digital energy meter with requisite class CT
SITC of Commercial Power Panel (CPP) No.
1.8 Design, Supply, installation, testing commissioning of A/C Power Panel (ACPP)
complete as per specifications, Drawings and as per following details:
1.8.1 A/C Power Panel (ACPP) as per specifications, Drawing and as per following details:
a) 2 No. of 250 A, 415V, 35kA, 4P MCCB with changeover switch built in
Microprocessor based release unit for Over Current, Short circuit and earth fault
protection with adjustable settings. The breaking capacity of MCCB shall be Icw=Icu.
MCCB shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) along with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
MFM shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) Auxiliary contacts required for necessary interlocking.
iii) Class-B, SPDs shall be provided in panel as per IEC 61643-12 or latest.
GMRC Page 86 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
iv) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
v) 1 set of MCB controlled phase indicating lamps for all three phases.
vi) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
vii) 3 Nos. of cast resin current transformers of 250/5 ratio with 15VA burden and Class
1.0 for measurement
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>160 A suitable to with stand symmetrical fault level of 35kA at 415 V. The neutral
busbar is to be of same size as phases.
a) 2 no.160A, 415V, Ics=25 kA, 4P MCCB’s(Motor Duty) with indicating lamps on each
phase to give indications.
b) 2 no. 63A, 415V, Ics=25 kA, TPN MCCB’s with indicating lamps (red) on each phase to
give indications.
c) 2 no. 20A, 230V, Ics=10 kA, DP MCB’s with indicating lamps (red) on each phase to
give indications.
SITC of A/C Power Panel (ACPP) No.
1.9 Design, Supply, installation, testing commissioning of Essential lighitng and power
panel for Emergency lighting which is fed from DG set. complete as per
specifications & Drawing with following:
1.9.1 Essential Lighting and Power Panel(ELPP)
A Incomer (from EMDB)
1 No. of 63 A, 415V, 25kA, 4P MCCB with built in Microprocessor based release unit
for Over Current, Short circuit and earth fault protection with adjustable settings.
The breaking capacity of MCCB shall be Icw=Icu. MCCB shall have in built
GMRC Page 87 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
compatibility through open protocol like Modbus for SCADA/BMS connectivity
(RS485) each along with following accessories.
i) 1 No. of Multi Function Meter of accuracy class-1 with all required to measure and
display the Electrical quantities like, Current, Voltage, Active Energy-KWH, Reactive
Energy-kVAH, frequency, Maximum Demand-KVA/KW, Total Hormonic Distortion &
power factor etc. with facility conforming to specifications and latest IEC standards.
MFM shall have in built compatibility through open protocol like Modbus for
SCADA/BMS connectivity (RS485) and all required accessories.
ii) 1 set of MCB controlled Breaker ON/OFF/TRIP indicating lamps.
iii) 1 set of MCB controlled phase indicating lamps for all three phases.
iv) Amber healthy trip indicating lamps
v) 3 Nos. of cast resin current transformers of 100/5 ratio with 15VA burden and Class
1.0 for measurement
vi) Auxiliary contacts required for necessary interlocking.
vii) Class-B SPDs shall be provided in all panels and Distribution Boards to meet all
functional requirement as per IEC 61643-12 or latest.
viii) Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
Electrolytic high conductivity tinned copper three phase and neutral busbars rated at
>63 A as per specification, suitable to withstand symmetrical fault level of 25 kA at
415 V with 100% rated neutral busbar.
4 Nos. of 10A/20A , 415V, 10kA, TPN MCB, with fixed neutral and variable
overcurrent, short circuit releases. Suitably rated AC3 Duty power contactor of with
necessary NO & NC auxiliary contacts as required for operation through BMS, Auto/
GMRC Page 88 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
manual selector switch, 1 set of MCB controlled Breaker ON/OFF/TRIP indicating
lamps, complete as required and approved.
SITC of Essential Lighting & Power panel (ELPP) No.
1.9 "Design, Detail Engineering, Supply, Erection, Testing and Commissioning of
Reactive Power Compensation and power quality Improvement along with
associated equipments & integration with existing protection and BMS system as
per specification and BOQ
1.9.1 Dynamic Reactive Power Compensation Panel , 33kV/0.415kV IGBT-based D-
STATCOM along with other associated equipments, associated control and power
cabling and earthing arrangement as per approved SLD , BOQ and specifications.
Bidder to quote the SITC price per KVAR basis. Actual payment shall be made as per
total KVAR installed at site per station. (Approx. KVAR per station required is 200)
SITC of Dynamic Reactive Power Compensation Panel. KVAR
TOTAL OF MV PANELS
2 MV DISTRIBUTION BOARDS
GMRC Page 89 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
A Supply, installation, testing & commissioning of front operated, front access cubicle
type, dead front, wall / recess/ surface mounted, totally enclosed dust and vermin
proof ( minimum protection IP 54 ) as per drawings and specifications. The
distribution boards shall be of sheet steel enclosure with copper bus bars suitable for
single or three phase MCBs. The MCB DB shall fabricated from 2 mm thick CRCA with
powder coated finish suitable for 415 V, 3-phase, 4 wire, 50 Hz system including
suitably rated insulated copper busbars, interconnections, neutral bar assembly,
phase segregating barriers, LED indicating lamps for incoming and outgoing feeders,
knockouts and gland plates for entry of cables and conduits, all internal wiring using
high temperature PVC FRLSH wires, independant terminals for each phase, neutral &
earthing terminals and including the cost of providing Master key lock on the door
and pad locking facility on door as well as at incomer, bonding to earth etc. complete
as per specification, drawings as required.
a) MCBs shall conform to IEC 60898 (latest) and, with breaking capacity 10 kA at 415 V
AC, current limiting type lower power loss appx 40 - 70% of the stipulated value and
suitable for magnetic releases operating between 3 to 5 times rated current for
normal power distribution application and 5 to 10 times rated current for motor
application duty, with minimum Electrical endurance of the order of 20000 operation
b) RCBO conforming to IEC 61009-1, IS 12640-2 shall be provided with 100mA
sensitivity and electrically connected rated current capacity MCB for short circuit
and over load protection as required
c) All incoming & outgoing feeders of DB shall be terminated on terminal blocks in the
upper compartment including Internal wiring by manufacturer.
d) Class-B SPDs shall be provided in all DB incomers as per IEC 61643-12 or latest.
e) Consider "B" curve for lighting," C" curve for power and "D" curve for UPS circuit
f) Common area DBs and Street Light DBs shall be controlled by
Timer+Contactor.Provision of Auxiliary contactors , push buttons and indicating
lamps for 50% ,75% and 100% selection. Local Remote selector switch for auto local
operation and lighting control from controlled desk BMS located at SCR.
GMRC Page 90 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
g) Variable control through BMS to be adopted to save energy for lighting system for
2.1 Distribution Boards(Type-1) as per specification and Drawing as per following No.
details. LPDB-1, and VD-DB-1,2,3,4 35.00
A Distribution board unit for lighting combined with Small Power consisting of one
compartments and upper compartment for terminal block with respective
incoming 4P MCBs having indications for incoming feeder status as per
specifications and as shown on Drawing and as under:
a) 1 no. 10/ 32 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 3 no. 32A DP RCBO for phase segregation.
d) 12 Nos 10/20 Amp SP MCB with feeder on indication Lamp
2.2 Distribution Boards(Type-2) as per specification and Drawing as per following No.
details.( LPDB-2,3,5,6) 35.00
A Distribution board unit for lighting combined with Small Power consisting of one
compartments and upper compartment for terminal block with respective
incoming 4P MCBs having indications for incoming feeder status as per
specifications and as shown on Drawing and as under:
a) 1 no. 10/ 32 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 3 no. 32A DP RCBO for phase segregation.
d) 18 Nos 10A/16A/20A/32A SP MCB with feeder on indication Lamp
2.3 Distribution Boards(Type-3) as per specification and Drawing as per following No.
details. ELDB-1,2,3,4,5,6, & UPS-1,2,3,4 63.00
GMRC Page 91 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
A Distribution board unit for lighting with respective incoming DP MCBs having
indications for incoming feeder status as per specifications and as shown on
Drawing and as under:
a) 1 no. 20/40 A, 10kA, DP, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 2 no. 32A DP RCCB .
d) 12 nos. 10A/16A/20A/32A SP MCB with feeder on indication Lamp
2.4 Lighting Distribution Boards (LDB) as per specification and Drawing as per following No.
details.(Advertisement) 21.00
A Distribution board unit for incoming 4P MCCBs having indications for incoming
feeder status as per specifications and as shown on Drawing and as under:
a) 1 no. 63 A, 16kA, 4P, MCCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
a) 9 Nos. of 20A/32A SP MCB arranged in sets of 3 nos. per phase with feeder on
indication Lamp
2.5 AC Distribution Board (ACDB) as per specification & Drawing & as per following No.
A Distribution board unit for incoming 4 pole MCBs having indications for incoming
feeder status as per specifications and as shown on Drawing and as under:
a) 1 no. 20/63 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
Contractor shall provide an earmarked potential free terminals for SCADA signals as
per specification & requirements.
GMRC Page 92 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
OUTGOINGS with feeder.
c) 3 no. 40A DP RCBO for phase segregation.
d) 24 nos. 16A, DP MCB C-Curve each having indication lamps to give status.
2.6 Distribution Boards as per specification and Drawing as per following No.
details.(Signage DB) 7.00
A Distribution board unit for lighting with respective incoming TPN MCBs having
indications for incoming feeder status as per specifications and as shown on
Drawing and as under:
a) 1 no. 20/40 A, 10kA, 4P, MCB
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 3 no. 32A DP RCBO for phase segregation.
d) 10 nos. 10A/16A/20A/32A TPN MCB with feeder on indication Lamp
2.7 Distribution Boards as per specification and Drawing as per following No.
details.(OUTDOOR VRV DB) 7.00
A Distribution board unit for lighting with respective incoming Four pole MCCBs
having indications for incoming feeder status as per specifications and as shown on
Drawing and as under:
a) 1 no. 160 A, 25kA, 4P, MCCB with microprocessor based release having continously
adjustable current setting in the range of 0.4 to 1.0 and 2-10 times of short circuit
protection as per Technical specification enclosed. Shall be suitable for total
discrimination.
b) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps.
OUTGOINGS with feeder.
c) 4 nos. 100A TPN MCCB with FEEDER ON indication Lamp
2.8 ENCLOSURE/ISOLATOR BOX
GMRC Page 93 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
A Design, Supply, Installation, Testing and Commissioning of Enclosure/Isolator Box
fabricated using CRCA Sheet Steel of 2mm. thick and powder coated (65 Micron
Minimum) surface/recess mountable unit having IP 54 with suitable current rated
TPN MCCB inbuilt with 100mA Earth fault release, spreaders & shrouds at all
terminals, gland plate for incoming & outgoing cables and with suitably rated MCB
controlled multiple LED lamps (Red, Yellow, Blue) for Phase indication and (Red,
Green, Amber) for ON, OFF & Trip status with all required accessories suitable for
230 VAC operation complete as required and approved.
a) 63A, TPN MCCB inbuilt with 100mA Earth fault release, complete as required. No.
b) 125A, TPN MCCB inbuilt with 100mA Earth fault release, complete as required. No.
TOTAL OF DISTRIBUTION BOARDS
3 MV CABLING & CABLE TRAYS
3.1 Power Cables
Supply, laying, testing and commissioning of 1100 V grade, XLPE insulated, PVC
extruded, armoured, FRLSH, Conductor cables as per Technical specification on
existing trays/ walls/ columns /indoor /trenches including the cost of supports with
suitable clamps, saddles, hooks, Anchor fasteners, bolts etc. including proper
dressing of cables, Route markers, providing identification tags, earthing of glands
armouring etc. complete as per specifications and as required. The cost of cable
trays excavation and back filling of trenches will be measured separate. The cost shall
include Heat Shrinkable cable jointing kits for joining cables wherever joints are
unavoidable due to unavailability of required length of cable in standard drum
a) 3.5 core 240 sq. mm Al Conductor RM
b) 3.5 core 150 sq. mm Al Conductor RM
c) 3.5 core 120 sq. mm Al Conductor RM
GMRC Page 94 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
d) 3.5 core 70 sq. mm Al Conductor RM
e) 3.5 core 50 sq. mm Al Conductor RM
f) 3.5 core 35 sq. mm Al Conductor RM
g) 4 core 16 sq. mm Cu Conductor RM
h) 4 core 10 sq. mm Cu Conductor RM
i) 3 core 16 sq. mm Cu Conductor RM
j) 3 core 10 sq. mm Cu Conductor RM
k) 3 core 6 sq. mm Cu Conductor RM
l) 3 core 4 sq. mm Cu Conductor RM
m) 4 core 2.5 sq. mm Cu Conductor RM
n) 1 core 16 sq. mm Cu Conductor RM
o) 1 core 95 sq. mm Cu Conductor RM
p) 3.5 core 95 sq. mm Al Conductor RM
GMRC Page 95 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
3.2 Cable end termination of cables detailed in item 3.1.1 above - including cost of
supplying and fixing of tinned copper Crimping type lugs, double compression brass
glands including earthing, insulation tape etc. Gland should be earthed individually
with gland ring copper strip and copper wire, complete as per specifications and as
a) 3.5 core 240 sq. mm Al Conductor No.
b) 3.5 core 150 sq. mm Al Conductor No.
c) 3.5 core 120 sq. mm Al Conductor No.
d) 3.5 core 70 sq. mm Al Conductor No.
e) 3.5 core 50 sq. mm Al Conductor No.
f) 3.5 core 35 sq. mm Al Conductor No.
g) 4 core 16 sq. mm Cu Conductor No.
h) 4 core 10 sq. mm Cu Conductor No.
l) 3 core 16 sq. mm Cu Conductor No.
j) 3 core 10 sq. mm Cu Conductor No.
k) 3 core 6 sq. mm Cu Conductor No.
l) 3 core 4 sq. mm Cu Conductor No.
m) 4 core 2.5 sq. mm Cu Conductor No.
n) 1 core 16 sq. mm Cu Conductor No.
GMRC Page 96 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
o) 1 core 95 sq. mm Cu Conductor No.
p) 12 C x 1.5 sq. mm Cu Conductor No.
q) 3.5 core 95 sq. mm Al Conductor No.
3.3 Supply, laying, testing and commissioning of Control cables of following size cables as
per List of approved makes including the cost of jointing & termination with required
a) 2 C x 1.5 sq. mm Cu Conductor RM
b) 12 C x 1.5 sq. mm Cu Conductor RM
c) 19 C x 1.5 sq. mm Cu Conductor RM
3.4 Cable Trays
3.4.1 Supply, installation of factory fabricated, perforated, hot dip galvanized (Minimum
Thickness shall be 85 microns), double bended cable trays from 2 mm thick sheet
steel continuously connected including inward, outward, horizontal & vertical bends,
reducers, tees, flexible earth connector and other accessories. All the cable tray
accessories shall be factory pre-fabricated, until otherwise specific approval is
obtained to fabricate at site.
a) 300 mm wide x 50 mm depth RM
b) 150 mm wide x 50mm depth RM
c) 100 mm wide x 50mm depth RM
d) 50 mm wide x 50mm depth RM
GMRC Page 97 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
3.4.2 Supply, installation of factory fabricated Ladder type hot dip (welded) galvanized
cable trays (Minimum Thickness shall be 85 microns) from 2.5 mm thick sheet steel
continuously connected including inward, outward, horizontal & vertical bends,
reducers, tees, flexible earth connector and other accessories. All the cable tray
accessories shall be factory pre-fabricated, until otherwise specific approval is
obtained to fabricate at site. Runner size shall be 75mm x 20mm x 2.5 mm and Rung
size 30mm x 20mm x 2.5mm with centre to centre distance of 250mm, as required.
a) 600 mm wide X 75 mm height RM
b) 300 mm wide X 75 mm height RM
3.4.3 Supply & erection of support brackets made out of Hot dip galvanised factory
fabricated cantilever support /channels in conformance to IEC 61537 to the required
size and shape.
a) Supply and installation as required for Factory Fabricated Hot dip galvanized (65 Kgs
micron thick) cantilever bracket support / fabricated member for fixing to wall/ 1,16,647.30
ceiling/beam and for use with cable tray systems or cable ladder system in terms of
IEC 61537 or Pendent with Mid support Bracket with high level of workmanship and
design approprietly sized as required in terms of the IEC 61537 for uniform
distibution and design appropiately sized as required in terms of the IEC 61537 for
uniform distribution of Load.
Note: Trays shall be supported adequately using galvanized structural members. This
support should be capable of withstanding the weight of the equivalent weight of 3m
length of cables laid over it. Rigid ISA / ISMC / ISMB / flats/ Vertical Rods support
shall be provided at every 1m length and also at diversions, crossings, bends and
multi layered locations.At turns the support has to be double and at both ends of the
3.5 Supply and fixing of Raceway junction box made out of 2.0mm thick sheet steel with
hot dip galvanizing finishing including polished 3/5mm Thick SS 304 top cover, fixed
with SS Counter Sunk screw of sufficient length.
GMRC Page 98 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
a) 250 x 250 x 75 deep box with polished 5mm SS sheet top cover No.
b) 150 x 150 x 75 deep box with polished 3mm SS sheet top cover No.
c) 100 x 100 x 75 deep box with polished 3mm SS sheet top cover No.
3.6 Supply and laying of raceway made of 2mm thick GI sheet with top cover race way
trunking of different size along with (covered in the followed item) as required. Note:
The rate is inclusive of all fixing arrangement, steel parts, welding work etc. as
required Contractor shall get the drawing / design of raceway approved from the
Engineer before bulk fabrication.
a) 200 x 50 x 2mm thick RM
b) 150 x 50 x 2mm thick RM
c) 100 x 50 x 2mm thick RM
TOTAL OF MV CABLE, CABLE TRAYS and RACEWAYS
4 WIRING SYSTEM
4.1 Supply & laying of conduit and wiring for the following light / Ceiling Fan/ Signage
with 3 x 2.5 sq. mm, 1100 Volt grade PVC insulated FRLSH copper condutor wires in
heavy gauge 25mm dia GI conduit (16 SWG) surface run with GI saddles, or
concealed or in GI raceway including chases and complete with GI junction boxes,
pull boxes, inspection boxes,bends & other accessories etc. including insulated
Protective Earth (PE) Conductor and earthing of switch boxes excluding the cost of
switches/sockets and switch boxes.as specified and as under:
First point controlled by one Swichboard (6A switch)/10A MCB No.
GMRC Page 99 of
TENDER NO. GMRC/CONS/STNS+VDCT-2/2026 BOQ
4.2 Secondary or looping points wiring as specified in 4.1 above using 3x2.5 copper No.
(P+N+PE) wires in 25 dia GI conduit (16 SWG) for lights, fans, socket outletsincluding 1,848.00
providing terminal block, ceiling rose & other accessories etc as required (exlcuding
the cost of switches, sockets & switch boxes) as per specifications and drawings as
4.3 Supply & laying of wiring for the following light point with 3 core x 2.5 sq. mm,
Volt grade PVC insulated FRLSH copper condutor flexible cabe in existing raceway or
existing heavy gauge GI conduit (16 SWG) surface run with GI saddles, or concealed
or in GI raceway including chases and complete with GI junction boxes, pull boxes,
inspection boxes,bends & other accessories etc. including insulated Protective Earth
(PE) Conductor and earthing excluding the cost of MCB as specified and as under:
One point controlled by 10A MCB. No.
4.4 Secondary or looping points wiring as specified in 4.3 above using 3 core x 2.5 sq. mm No.
insulated copper (P+N+PE) flexible cable in existing GI raceway for lights on Platform 1,680.00
outlets including providing terminal block, ceiling rose & other accessories etc as
required (exlcuding the cost of switches, sockets & switch boxes) as per
specifications and drawings as required
4.5 Supply & laying of conduit and wiring for the following 16A / 32A socket outlet point
with 3 x 6 sq. mm, 1100 Volt grade PVC insulated FRLSH copper condutor wires in
heavy gauge GI conduit (16 SWG) surface run with GI saddles.
a) One no. 16A /32A socket outlet point controlled by one 16A switch / 32A MCB. No.
4.6 Secondary or looping 16A socket outlet points wiring as specified in 4.5 above using 3 No.
x 4 sq. mm copper (P+N+PE) wires in 25 dia GI conduit (16 SWG) for socket 560.00
outletsincluding providing terminal block, ceiling rose & other accessories etc as
required (exlcuding the cost of switches, sockets & switch boxes) as per
specifications and drawings as required
With regard to Item Nos.4.1 to 4.6, for further clarifications, the sample
measurement system to be followed is given below :-
GMRC Page 100 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Volume - 1 NIT STNS - VDCT - 2.pdf
2. Volume - 1 ITT STNS - VDCT - 2.pdf
3. Volume - 1 FoT STNS - VDCT - 2.pdf
4. Volume - 2 GCC STNS - VDCT - 2.pdf
5. Volume - 2 SCC STNS - VDCT - 2.pdf
6. Volume - 2 SHE STNS - VDCT - 2.pdf
8.1 Volume - 3 Technical Specification_Civil STNS - VDCT - 2_1.pdf
8.1 Volume - 3 Technical Specification_Civil STNS - VDCT - 2_2.pdf
8.2 Volume - 4 Technical Specifications - EM STNS - VDCT - 2_1.pdf
8.2 Volume - 4 Technical Specifications - EM STNS - VDCT - 2_2.pdf
8.2 Volume - 4 Technical Specifications - EM STNS - VDCT - 2_3.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_1.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_2.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_3.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_4.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_5.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_6.pdf
7. Volume - 3 Employers Requirement STNS - VDCT - 2_7.pdf
9. Volume - 5 Tender Drawings STNS - VDCT - 2.pdf
10. Volume - 6 BOQ STNS - VDCT - 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .