Tender Value
₹2.6 Cr
EMD Value
₹5.3 L
Closing Date
8 Oct 2026, 3:30 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTE/RJT
16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:Three similar works each costing not less than the amount equal to 30% of advertised value of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of tender. NOTE: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered atleast 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities,bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Similar Nature: -Any signaling work involving outdoor work and/or addition and/or alteration in existing indoor signaling system OR any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving Indoor and /or Outdoor work. Similar work to include indoor if the tendered work involves addition and/or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work OR any such work involving activities as given in the name of tendered work.
EI alteration is required at SUNR, LPR, HM, ALB & MTKD station in Different (Mention in Special Condtion) make EI system in connection of Creation of TMC siding facilities work. All the items pertains to EI alteration i.e, Logic, FAT, SAT, TOC, Change in VDU diagram, documentations etc. whether it is mentioned or not in Schedule item (Sch-B1 item no.1 &2, Sch-B2 item no.1), Everything pertains to EI alteration is covered in this particular schedule item.
Undertaking by the tenderer that the equipment of EI shall be procuredfrom RDSO approved sources and modification, alteration, installation and testing of EI shall also be got done from the same source/OEM including after sales support required during warranty period should be submitted. ( Click here to download Format)
18 conditions · 3 needing a document upload
1.EMD/Bid security is deposited as per Clause 5 of Part I "regulations for tenders and contract " of tender document. 2.EMD need to be deposited online on www.ireps.gov.in. 3. For the tenders costing upto 50 Lakhs: - No technical and financial credentials required but firm's documents and any other mandatory documents which are demanded in tender are require to be submit at the time of bidding. 4. tender having value more than 50 Lakhs: - Financial and technical credentials required as per GCC applicable and firm's documents and any other mandatory documents which are demanded in tender are require to be submit at the time of bidding.
1. If Tenderer is sole proprietor: Affidavit on Stamp paper of appropriate value declaring that his/her concern is a Proprietary concern or any other documents such as GST Certificate, PAN Card of firm Name etc. is to be submitted. 2. If Tenderer is partnership firm: Notarized partner ship deed Original / Notarized power of attorney. 3. If Tenderer is JV/Limited Company: Copy of Memorandum and Articles of Association of the company. Power of Attorney (duly registered/notarized as per prevailing law) by the company authorizing the person to do/act on behalf of the company. 4. If Tenderer is Company: Copies of MOA (Memorandum of Association) & AOA (Articles of Association) of the company. Power of attorney duly registered/notarized by the company in favour of the individual signing the tender on behalf of the company. Resolution of Board of directors in regards of approving Power of attorney issued. 5. If Tenderer is Society: Attested copy of the certificate of registration. Deed of formation. Power of attorney in favour of the tender signatory. 6. Copy of PAN number and TIN number.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rajkot- Division :- Creation of TMC siding facilities at (i) 05 stations (LPR, SUNR, WKR, RJT & DAC)and allied facilities at LTR (ii) 08 Station (PDH, HM, ALB, LKBL, MTKD, KMBL, BHTA, DWK).
DRM-RJT-26-27-SnT-E-19~WR
DRM-RJT-26-27-SnT-E-19
Open
Works - General
12 Months
Rajkot, Gujarat
₹0
₹5.3 L
9 Sept 2026
9 Sept 2026
24 Sept 2026
311 items across 6 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 35,48,438.55 | ||
| — | 2.00 | — | — | ||
| Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards. Station | — | — | — | 1,27,396 | |
| — | 6.00 | — | — | ||
| Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | — | — | — | 27,180.42 | |
| — | 6.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 21,139.62 | |
| — | 12.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments. | — | — | — | 25,554.36 | |
| — | 18.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged). | — | — | — | 39,848.58 | |
| — | 6.00 | — | — | ||
| Supply of DC Track Circuit Accessories as follows :- Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 5,870.76 | |
| — | 5.00 | — | — | ||
| Hydrometer, Exide make or similar for measuring the specific gravity of Battery Graded acid with mounting stand in location Boxes. | — | — | — | 1,412.3 | |
| — | 20.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F-8B/12F-4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23. | — | — | — | 85,689.6 | |
| — | 20.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 1,11,520.8 | |
| — | 20.00 | — | — | ||
| Relay, AC Immune, Plug-in-type, style "QNA1K" ACI DC Neutral line, 24V DC 1000 Ohms 6F.6B contacts, front contacts metal to carbon and back contacts metal to carbon. Complete with plug board, retaining clip and connectors confirming to IRS: S34, IRS: S23, BRS931A. As per RDSO Specification No. STS/E/Relays/UEA (PI) Dt.30/05/97. Annexure II. The interlocking pin code CDEKY. | — | — | — | 1,10,506.2 | |
| — | 15.00 | — | — | ||
| Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable). | — | — | — | 84,196.5 | |
| — | 15.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23. | — | — | — | 1,10,856.6 | |
| — | 6.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60-78. | — | — | — | 32,528.4 | |
| — | 15.00 | — | — | ||
| Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78. | — | — | — | 1,10,905.2 | |
| — | 4.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | — | — | — | 38,975.88 | |
| — | 4.00 | — | — | ||
| Supply and fixing of CH/KLCR boxes appropriate size in field / in location boxes / in SM office / at LC gate as per site condition. It should be made of Hylam /wooden (teak wood) of high quality as per requirement. Item includes supply of any minor bracket nuts, bolts and hole drilling MS angle, MS plate etc. It also includes fixing of KLCR relays in the boxes. Prior approval to be taken from Engg. In charge before supply of box. | — | — | — | 6,145.96 | |
| — | 2.00 | — | — | ||
| Supplying & fixing of key box made of MS sheet/ wood with a glass front and padlocking and sealing arrangements per std practice. Pad lock to be supplied by the contractor. All material i.e. wood, handle, hinges, glass sheet of 3 mm thick to be supplied by the contractor. Box to be powder coated/polished and description/size to be as per instructions of Engineer in - charge. | — | — | — | 2,785.66 | |
| — | 2.00 | — | — | ||
| Supply of self supported aluminum flat step ladder (conforming to ISI) 5 ft. height. Ladder should be self-supported and it should be made up of rust proof Aluminum of Min 16 SWG. No plastic hinges/Step support should be used. | — | — | — | 6,179.8 | |
| — | 1.00 | — | — | ||
| Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.) | — | — | — | 26,249.42 | |
| — | 1.00 | — | — | ||
| Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | — | — | — | 24,008.12 | |
| — | 360.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Disconnect Terminal Block, Screw less type, 4- wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 21,070.8 | |
| — | 60.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 664.2 | |
| — | 60.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 651.6 | |
| — | 10.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 1,138.8 | |
| — | 12.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 33,587.88 | |
| — | 4.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. | — | — | — | 41,612.32 | |
| — | 600.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 45,000 | |
| — | 4.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 2,07,992.24 | |
| — | 4.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 2,39,423.92 | |
| — | 3.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 16,645.62 | |
| — | 0.40 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 13,346.48 | |
| — | 0.40 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 54,425.42 | |
| — | 0.40 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 53,002.05 | |
| — | 800.00 | — | — | ||
| Supply Polyolefin cable channel of size width 240/340 mm, height 155/230 internal/external, length 1meter produced of polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. | — | — | — | 17,42,496 | |
| — | 30.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 57,366 | |
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | 18.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC APRIL 2022
ATTACHMENT
ACS12andAllmerged.pdf
ATTACHMENT
Special Condition of Contract
ATTACHMENT
DRM-RJT-26-27-SnT-E-19-GCCAPRIL2022.pdf
ATTACHMENT
SpecialconditionofcontractE-19.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .