Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.8 L+₹2.7 L (7.58%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.8 L+₹2.8 L (7.75%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹41.4 L+₹5.3 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹41.7 L+₹5.7 L (15.8%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
8 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Tezpur
GE (North) Tezpur, c/o 99 APO
SPL REPAIR TO BLDG NO T-09 AND OTHER REV/ MINOR WORKS AT AGE CHARDUAR UNDER GE (NORTH) TEZPUR
2023_MES_608612_1
GE(N)/TEZ/2023-2024/8738
Open Tender
Civil Works
Item Rate
180 days
GE (North) Tezpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE (North) Tezpur
₹95,000
19 Sept 2023
11 Jul 2023
15 Aug 2023
11 Jul 2023
8 Aug 2023
25 Jul 2023
Amount
Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting agle iron, roof top MS sheets, railings etc omplete all as spcified and directed
S & F MS steel work in /rectangular trusses/angle and posts/purlin including special shaped washers etc., complete using but welded tubes confirming to IS 1161- 1979 graded St 240 with one shop coat of zinc chromate primer paint as in gates post purlin etc complete all as specified and directed.
Supply and fixing mild steel plates, plain or chequered, 5 mm thick or over in thickness in available sizes of grade E 250 quality C conforming to IS 2062: 2011
S & F mild steel screw bolts (machine made), diameter of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.18sqm but not exceeding 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed.
M&L coloured glazed ceramic tiles in vertical surfaces (size recommended by Engineer-in-charge), skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Dismantling ceiling boards (Fibre/Pulp/Plywood) any thickness including cover fillets complete all as specified and directed.
M & L for anodised GI snap (Size of grid 605mm x 605mm ) frame work for false ceiling including GI wire 4mm thick as a suspender for GI snap grid framing all complete all as specified and as directed.
M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified as directed by the Engineer-in-Charge.
Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position complete all as specified and as directed.
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area exceeding 13 sqcm but not exceeding 25 sqcm including taking down complete all as specified and as directed.
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area exceeding 6 sqcm but not exceeding 13 sqcm complete all as specified and as directed.
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular, triangular in section, bull nosed, splayed, chamfered or rounded on one edge or face, clean sawn, secured with screws, cross sectional area exceeding 3 sqcm but not exceeding 6 sqcm complete all as specified & as directed.
S&F wire netting of stainless steel wire 1.40 mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified and directed.
S & F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed.
Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed.
S&F Boarding, 40mm thick for 2nd class hard wood in scantling planed on both sides timber framed and fixed in ceiling complete all as specified and directed.
M&L for 40mm thick hard wood planed at both sides boarding as in rafters,truess and members complete all as specified and directed
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M & L rendering 5 mm thick in cement plaster in cement mortar (1:4) mixed with integral water proofing compound @3%by wt of cement over 10 mm thick backing coat in cm (1:4) on fair faces of brick work or concrete surface complete all as specified and directed. Note : water proofing compound shall be measured and paid separately).
Supply only liquid water proofing compound complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed.
S & F GI wire netting 0.90 mm dia and 13 mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
Material and labour for plastering 10 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
Material and labour for plastering 10 mm thick on the other side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection/paving finish all as specified and as directed.
M & L for forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound Grade "A" after priming the contact surfaces using suitable primer complete all as specified and as directed.
M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 -25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
M&L PCC in surface channels and drains type B1 (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
S&F 2nd class Hard wood scanttlings, wrought in any position for framed work jointing wirh nails, screws, nut bolt etc. including necessary supports to existing truss including Dismantling of timber scanttlings 40 Sqcm & over in section, in any position for framed workcomplete all as specified and directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down wooden door shutter area not exceeding 1.00 sqm each complete all as specified and as directed
Taking down and refixing in same opening wooden door shutter area not exceeding 1.00 sqm each complete all as specified and as directed.
Taking down and refixing in same opening wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
M & L for plain, solid, straight chowkhats and frames made out of 2nd class timber species of group I and durability class II as per IS 12896: 1990 and first grade as per IS 4021: 1995, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F 2nd class softwood 35mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats
S&F 2nd class softwood 30 mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (b); to chowkats
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M & L for 12 mm thick (7 ply) plywood, boiling water resistance(BWR) Grade and Type BB as per IS 303: 1989 and IS 848: 2006; fixed with screws to timber frame work complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F in repairs brass chromium/aluminium plated brackets complete all as specified and directed by Engr in charge.
S & F 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. Make Jaquar, cat aprt No AEC 1111, Make Hindware Cat part No F450024
S & F vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed by Engineer-in-Charge.
M & L for PVC connections 15 mm size with PTMT nuts of length 300/450 mm complete all as specified and as directed.
S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed.
S & F PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed.
S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed.
S & F UPVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed.
S & F UPVC (SWR) bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F UPVC (SWR) bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
S & F PVC (SWR) vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and as directed.
S & F PVC (SWR) Tee(87.5⁰) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
M & L for concrete bed to drain pipes of internal diameter 110 mm, in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
M&L for preparation of new plastered or undecorated surfaces of wall using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for preparation of old surfaces of wall by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of cement base paint complete all as specified and as directed.
M&L for preparation of old decorated surfaces including washing, rubbing down and stopping of white wash surfaces of walls (Plastered or un-plastered) including cormices pilasters etc and using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller including one coat of alkali resistant priming paint before distempering complete all as specified and directed.
M&L for preparation of new surface of plastered wall using wall care putty to fill the voids and applying two coats of oil bound distemper and finished another one coat with spunge roller over including one coat of alkali resistant priming paint before distempering complete all as specified and directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
M & L for rendering 15mm thick cement plaster in cm 1:4 on fair faces brick or concrete surfaces using water proofing compound of wall (WPC added only 5 mm thick plaster) including finished even and smooth without using extra cement complete all as specified and as directed.(WPC Shall be paid and meassured separately)
Supply only integral water proofing compound complete all as specified and as directed.
M & L for preparation of new plaster surface of wall and applying two coats of cement base paint complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed.
M&L for 20-25mm thick machine cut kota stone slab flooring over 15mm thick screed bed or bedding layers laying in CM (1:6) for floor finishes to receive kota stone laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding and polishing complete all as specified and directed by Engr-in-Charge.
M&L for 20-25mm thick machine cut kota stone as in skirting/dado over 10mm thick screed bed or bedding layers laying in CM (1:4) for floor finishes to receive kota stone laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding and polishing complete all as specified and directed by Engr-in-Charge.
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
S & F mild steel screw bolts (machine made), diameter of neck 16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 15 cm but not exceeding 22.5 cm long complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long complete all as specified and as directed.
M&L for plinth protection or in foot path of 75 mm thick of cement concrete using type C-1, 1:3:6 (using 20 mm nominal size crushed and graded stone aggregate) in alternate penals and finished fair and even complete in all respect as specified and directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
S & F 1.00 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.11sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
M&L coloured glazed ceramic tiles 200x 300x7 mm thick, in vertical surfaces, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating over areas exceeding 1.5 m but not exceeding 3 m deep and getting out in soft/ loose soil complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair using extra cement complete all as specified and directed.
M & L for 20 mm thick damp proof course in cement mortar (1:2) mixed with integral water proofing compound to horizontal or vertical surfaces including necessary formworks complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.06sqm but not exceeding 0.11 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed.
S&F rolled section as in framing for door/vent/CB/chowkhats, wind tie and the like using angle, tee, hollow tubes etc., cleat and connecting plates complete (Butt hinges shall be measured and paid for separately) using Fe 410-W (Gde-E-250) quality "A" complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, nickel-chromium plated finished complete all as specified and as directed.
S & F 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed.
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete complete all as specified and as directed.
S & F in repair wash hand basins, vitreous China of size 550 x400mm (flat back or angle back type), including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32mm dia bore waste fitings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement, PVC waste pipe including 15mm bore dia fancy type CP finish Pillar tap, cast copper alloy with capstan heads, screwed down high presuure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipes complete all as specified and directed.
S&F 32mm spring type PVC waste pipe fixed to WHB urinal etc complete all as specified and directed. (Note : minimum length of each pipe should not be less than 0.70 RM)
S & F 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed.
S & F for 15mm size PVC connection pipe with PTMT nut of length 450mm complete all as specified and directed.
S & F vitreous china urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engineer in charge.
S & F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60 gms) complete all as specified and as directed.
S&F in repair EWC vitrous china colour/white , P or S trap,incliding connection to drain or out going pipe and to flushing pipe with plastic water closet seat white pattern , flat bottom and cover including MS CP hinges complete all as specified and directed.
S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with brass chromium plated bracket guard and railing 60 cm long complete in all respect as specified and directed.
M & L for precast cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L point wiring for light point/fan/bell point controlled by one, one way switch/bell push using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated sheathed FRLS cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed recessed boxes confirming to IS-14772-20000 for mounting of switches/sockets/regulators/bell push etc and1.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc. complete.
M&L wiring for one 3/5 pin socket outlet 5 amps on independent board using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated sheathed FRLS cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed recessed boxes confirming to IS-14772-20000 for mounting of switches/sockets etc and1.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc. complete all as specified.
All as per item 152 above but for One 3 pin socket outlet 5 Amps on same board complete all as specified and as directed.
All as per item No.152 above but with 2.5 sqmm single core multistranded copper conductor FRLSH cable for 3/5 pin 15 Amp socket outlet on independent board complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. (Cat No. AHESXXW061 of make Havells REO or equivalent in Anchor/Legrand)
S & F in replacement of switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S&F in replacement switch socket combination 2 in one, 5 pin 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
Supply and fix in replacement wall mounted LED tubelight fitting batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver lamp type 20 watt 6000K 4 feet.Make: Havells/surya/philips or equivalent make
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S&F S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.Make: Havells/surya/philips or equivalent make
S&F in replacement of 10 watt LED new adore 10WB22 cool day light ball lamp complete all as specified and directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 5-32 amps SP and current carrying capacity in the MCB DB complete with connection testing and commissioning. Note: MCB SP amps rating should be design on the base of load of the fitting/fixture used no overload current permissible or damage to wiring cable or as directed by Engr in Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 16-32 amps SPN and current carrying capacity in the MCB DB complete with connection testing and commissioning. Note: MCB SPN amps rating should be design on the base of load of the fitting/fixture used no overload current permissible or damage to wiring cable or as directed by Engr in Charge.
S & F sheet metal enclosure double door for DBs SPN 4 way 240 V complete double door, flush mounted all as specified and as directed
S&F in replacement sheet metal enclosure MCB DB double door 8 ways with 200 Amps rated bus bar SPN complete all as specified and as directed.
M & L for submain wiring with two runs of PVC insulated multistranded, copper coductor of size 4 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 4 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 4sqmm cable+ 1 run of 4sqmm earthed cable+ 1 run of casing capping shall be measured as one unit.
Material & Labour for one twin core cable flat or circular, 1100 volts grade heavy duty cable, PVC insulated, with stranded aluminium conductor, size 10 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating in service hangers not more than 1 metre apart, and including taking down of unserviceable service connection complete all as specified and directed.
Material and labour for house service bracket (hook type) complete with 3 mtrs long GI pipe 40mm dia, medium grade, 2 Nos 90 degree MS hook and stay or gay on the wall by grouting cement mortar and make good on all disturbed surfaces complete.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common saft filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron light grade pipe 15mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in Electrical Plate No 3 of SSR 2009( Part-I).
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
All as per item No. 172 here-in- before but for 3 pin 15 Amps switch socket combination on independent board with 2.5 sq mm copper cable
S & F in replacement of socket out let, 5 pin 5 Amps flush type complete all as specified and directed.
M&L for switch socket combination 2 in one, 5 pin, 5 Amps 240 volts flush type complete all as specified and directed.
S & F for switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed.
S & F in replacement of step type electronic fan regulator 120 watt single pole 240 Volts complete all as specified
S & F suitable size fan hook made of mild steel including suitable size of clamp for mounting ceiling fan to be attached with RCC roof, truss roof etc including aking down old unserviceable fan hook complete all as specified and directed.
Supply & fixing ceiling fans energy efficient 1200mm sweep complete including provision of PVC insulated copper multi starnded three core flexible cable for making necessary electrical connections from ceiling rose to connector all as required at site.MAKE- USHA 1200MM ENERGIA 32 (BLDC) 5 STAR or equivalent.
Material & Labour for one twin core cable flat or circular, 1100 volts grade heavy duty cable, PVC insulated, with stranded aluminium conductor, size 16 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating in service hangers not more than 1 metre apart including 4mm GI suspension wire, and including taking down of unserviceable service connection complete.
All as per item 172 above but for One 3 pin socket outlet 5 Amps on indpendent board complete all as specified and as directed.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 2 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.
S&F wall mounted fan of AC 230 V 50 Hz of 300mm including hanging to wall at defined loaction with screw,nut bots & washer after fininshing make good surface any patches to be remove after completion of work complete all as specified and as directed.
Supply & Fix Heavy duty Exhaust Fan 300mm sweep, 1400RPM ,with metal blade and louver complete fixed in wall with fastener and including making hole in wall of suitable size and plastering finishing of surfaces complete all as specified and directed. Make: Usha / havells/ bajaj
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 amps complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper/steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate NRV, connection piece complete all as specified and directed.
S&F cock, bib, brass chromium plated, screwed down for size 15 mm (1/2') dia complete all as specified and directed.
M & L for submain wiring with two runs of PVC insulated multistranded, copper coductor of size 2.5 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 2.5 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 2.5sqmm cable+ 1 run of 2.5sqmm earthed cable+ 1 run of casing capping shall be measured as one unit.
S&F of refrigrator single/double door of minimum capacity of 260 Lts or near by capacity frost free 230 v Ac 50 Hz freestanding energy efficient 5 star rating all as specified as directed by Engr In charge complete all as specified and as directed.
Supply & fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130V to 280V with output voltage stabilizer at 230 with accuracy ± 2.5% and capacity 1.0 KVA complete all as specified and as directed.
S&F in replacement switch socket combination 2 in One , 5/6 pin,5/6/16 Amps flush type complete all as specified and directed.
M/S JALALUDDIN AHMED
DRISTEE ASSOCIATES
M/S Bishwanath Mahato
Ms N D Enterpise
M/S SAMJHANA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .