Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC Being Lowest Vendor | |
| 2 | L2₹30.1 L+₹7,103.36 (0.24%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹32.4 L+₹2.4 L (7.98%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹32.4 L+₹2.4 L (7.99%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹33.1 L+₹3.1 L (10.3%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | SAI SREENIVASA ENGINEERING L5 | R AND A ASSOCIATES ENGINEERS CONTRACTORS L8 | GVR ENGINEERING WORKS L10 | Power Dynamics L9 | SIRI CONSTRUCTION L6 | MSN ENGINEERING WORKS L7 | aswitha engineering works L2 | B.Veerabhadra Rao L3 | B SRINIVAS L1 | LND Enterprises L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair/maintinance of multiple section of LT Panel board at indoor substation comprising minimum up to 10 Nos ACBs/ MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray chamber after opening front/top/side/back cover by using forced air pressure and brushes, cleaning of all dust/durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar/switchgear, repair/replacement to defective metering wiring from ACB/MCCB/CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of all aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/door knob and hinges all as specified and directed for
Note:- (i) Panel Meter, indicator lamp, MCB,busbar and CT will be measured and paid seperately as supply only. (ii) required aluminium cable lugs, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing/maintinance of ACBs measured seperatelly. (iv) cable connection disconnection included inclusive of quoted rate. | 8 | Each Job | 2,500 ₹20,000 | 1,200 ₹9,600 Lowest | 4,000 ₹32,000 | 7,500 ₹60,000 | 2,800 ₹22,400 | 5,000 ₹40,000 | 2,675.83 ₹21,406.62 | 1,899 ₹15,192 | 2,000 ₹16,000 | 3,225 ₹25,800 |
| 2.00 | All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 15 Nos | 15 | Each Job | 3,200 ₹48,000 | 1,200 ₹18,000 Lowest | 4,300 ₹64,500 | 8,500 ₹1,27,500 | 3,070 ₹46,050 | 5,500 ₹82,500 | 3,669.47 ₹55,042.05 | 2,799 ₹41,985 | 4,500 ₹67,500 | 4,125 ₹61,875 |
| 3.00 | All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 21 Nos | 10 | Each Job | 4,598 ₹45,980 | 1,200 ₹12,000 Lowest | 4,600 ₹46,000 | 10,000 ₹1,00,000 | 6,400 ₹64,000 | 7,000 ₹70,000 | 7,545.68 ₹75,456.79 | 3,699 ₹36,990 | 7,000 ₹70,000 | 8,100 ₹81,000 |
| 4.00 | Repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and directed.
Note: (a) Required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) All cleaning agents are included in the quoted rate. (c) Cable connection and disconnection are included in the quoted rate. | 30 | Each Job | 1,150 ₹34,500 | 800 ₹24,000 Lowest | 4,600 ₹1,38,000 | 5,000 ₹1,50,000 | 1,810 ₹54,300 | 3,500 ₹1,05,000 | 3,391.5 ₹1,01,745 | 1,899 ₹56,970 | 2,300 ₹69,000 | 2,450 ₹73,500 |
| 5.00 | Supply only fixed contract of ACB 630A to 3200A all as specified and directed. | 6 | Each | 1,535 ₹9,210 | 2,800 ₹16,800 | 5,500 ₹33,000 | 5,000 ₹30,000 | 1,360 ₹8,160 | 3,500 ₹21,000 | 1,418.35 ₹8,510.1 | 900 ₹5,400 Lowest | 1,683 ₹10,098 | 1,493 ₹8,958 |
| 6.00 | Supply only Moving contract of ACB 630A to 3200A all as specified and directed. | 6 | Each | 2,000 ₹12,000 | 2,100 ₹12,600 | 3,500 ₹21,000 | 5,000 ₹30,000 | 2,170 ₹13,020 | 3,000 ₹18,000 | 1,720.47 ₹10,322.81 Lowest | 1,800 ₹10,800 | 3,717 ₹22,302 | 2,700 ₹16,200 |
| 7.00 | Supply only Electronic protection unit of ACB 630A to 3200A all as specified and directed. | 6 | Each | 9,900 ₹59,400 | 4,000 ₹24,000 | 63,000 ₹3,78,000 | 15,000 ₹90,000 | 5,500 ₹33,000 | 2,800 ₹16,800 Lowest | 5,275.08 ₹31,650.5 | 8,000 ₹48,000 | 9,000 ₹54,000 | 7,650 ₹45,900 |
| 8.00 | Supply only shunt trip coil of ACB 630A to 3200A all as specified and directed. | 2 | Each | 4,500 ₹9,000 | 4,000 ₹8,000 | 3,500 ₹7,000 | 2,350 ₹4,700 Lowest | 3,070 ₹6,140 | 3,200 ₹6,400 | 7,034.75 ₹14,069.5 | 4,500 ₹9,000 | 6,676 ₹13,352 | 6,050 ₹12,100 |
| 9.00 | Supply only closing coil ACB 630A to 3200A all as specified and directed. | 2 | Each | 4,600 ₹9,200 | 4,000 ₹8,000 | 4,800 ₹9,600 | 2,350 ₹4,700 Lowest | 3,070 ₹6,140 | 3,000 ₹6,000 | 7,034.75 ₹14,069.5 | 4,500 ₹9,000 | 6,676 ₹13,352 | 6,050 ₹12,100 |
| 10.00 | Supply only digital electronic Ammeter (0-3200 amps range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed.
Make :- Cat Part No:-30002385 (DM3110) of Schneider or Conserve/L&T/HPL | 10 | Each | 1,600 ₹16,000 | 1,400 ₹14,000 | 1,350 ₹13,500 | 1,300 ₹13,000 | 703 ₹7,030 Lowest | 1,700 ₹17,000 | 1,482.95 ₹14,829.5 | 900 ₹9,000 | 1,430.16 ₹14,301.6 | 1,300 ₹13,000 |
Tender Value
₹47.0 L
EMD Value
₹94,020
Closing Date
16 Mar 2026, 6:30 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR MAINTENANCE OF LT ELECTRICAL PANEL BOARDS AND ALL ACCESSORIES INCLUDING REPLACEMENT OF UNSV ITEMS GALLERY EARTHINGS EARTHING STRIPS AND ALLIED WORKS AT NEW DOCKYARD JETTY SUBSTATIONS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAP
2026_MES_753812_1
8465/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹94,020
Yes
9 Jun 2026
23 Feb 2026
18 Mar 2026
23 Feb 2026
16 Mar 2026
9 Mar 2026
24 Feb 2026 - 7 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair/maintinance of multiple section of LT Panel board at indoor substation comprising minimum up to 10 Nos ACBs/ MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray chamber after opening front/top/side/back cover by using forced air pressure and brushes, cleaning of all dust/durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar/switchgear, repair/replacement to defective metering wiring from ACB/MCCB/CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of all aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/door knob and hinges all as specified and directed for
Note:- (i) Panel Meter, indicator lamp, MCB,busbar and CT will be measured and paid seperately as supply only. (ii) required aluminium cable lugs, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing/maintinance of ACBs measured seperatelly. (iv) cable connection disconnection included inclusive of quoted rate. | 8 | Each Job | - | - |
| 2 | All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 15 Nos | 15 | Each Job | - | - |
| 3 | All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 21 Nos | 10 | Each Job | - | - |
| 4 | Repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and directed.
Note: (a) Required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) All cleaning agents are included in the quoted rate. (c) Cable connection and disconnection are included in the quoted rate. | 30 | Each Job | - | - |
| 5 | Supply only fixed contract of ACB 630A to 3200A all as specified and directed. | 6 | Each | - | - |
| 6 | Supply only Moving contract of ACB 630A to 3200A all as specified and directed. | 6 | Each | - | - |
| 7 | Supply only Electronic protection unit of ACB 630A to 3200A all as specified and directed. | 6 | Each | - | - |
| 8 | Supply only shunt trip coil of ACB 630A to 3200A all as specified and directed. | 2 | Each | - | - |
| 9 | Supply only closing coil ACB 630A to 3200A all as specified and directed. | 2 | Each | - | - |
| 10 | Supply only digital electronic Ammeter (0-3200 amps range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed.
Make :- Cat Part No:-30002385 (DM3110) of Schneider or Conserve/L&T/HPL | 10 | Each | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
8465Tender.pdf
Tender Documents • 1.15 MB
BOQ_844312.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .