Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.3 LAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L1 | Accepted-AOC AOC | |
| 2 | L2₹72.3 L+₹4.0 L (5.88%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹72.8 L+₹4.5 L (6.66%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹75.9 L+₹7.6 L (11.1%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹76.7 L+₹8.4 L (12.4%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹94 L
EMD Value
₹1.7 L
Closing Date
6 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Ezhimala
CWE Ezhimala Naval Academy Post Kannur 670310
CONVERSION OF LT OVERHEAD LINE TO LT UNDER GROUND CABLE AT WATCH TOWER NOS. 05 TO 08 AT INA EZHIMALA
2024_MES_636702_1
CWE/80479/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ezhimala
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE Maint Ezhimala
₹1.7 L
Yes
17 Feb 2024
10 Jan 2024
8 Feb 2024
10 Jan 2024
6 Feb 2024
31 Jan 2024
10 Jan 2024 - 20 Jan 2024
Amount
Taking down old unserviceable overhead ACSR conductor of any type complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable GI earth wire of any type from distribution span complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable MS channel,cross arm, clamp, and all accessories complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable insulator of any size complete all as specified and directed by Engineer-in-charge.
Material and lablour for excavation in trenches not exceeding 1.5 metre in width and depth and getting out in hard and dense soil all as specified and as directed. Note: (i) Prior approval of station HQ shall be obtained for excavation work to avoid loss of other co existing utility services (ii)The excavation shall done manually only.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and directed by Engineer-in-charge.
Material and lablour for spreading riddled earth for cushioning and covering of the UG cable in trenches ground cable including punning down all as specified and directed. NOTE: Punned thickness shall be measured and paid.
Supply and lay PCC un-reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and directed. Note: Contractor shall produce PCC cable cover test certificate from the manufacturer.
Supply and fix Cable route indicator for LT UG cable made out of cast iron round plate of 100 mm dia and size of cable clearly mentioned with blue colour showing Voltage, cable type and size fixed on MS angle Iron of size 40x40x5mm thick with GI nut,bolt and washer MS angle grouted in PCC block 1:3:6 type C1 using 20mm graded stone aggregate of size 20 x20x30 Cm including excavation and earth work and painting to steel surfaces with two coats synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supplying, laying, testing and commissioning of LT UG cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated heavy duly galvanized steel strip armoured LT 1100 volt grade with aluminium conductors of size 95 sqmm 3.5 core complete all as specified and directed by Engineer in charge. NOTE: Earth work shall be measured and paid separately under relevant itmes.
All as per item No.11 above but of size 50 sqmm, 3.5 core complete all as specified and directed by Engineer in charge.
All as per item No.11 above but of size 16 sqmm, 4 core complete all as specified and directed by Engineer in charge.
All as per item No.11 above but of size 10 sqmm, 4 core complete all as specified and directed by Engineer in charge.
Material and labour for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.3 M and depth 0.6 M all as directed and making good the road/hard using pre mix bituminous mixture materials as required at site to match with the existing surface complete all as specified and directed by Engineer in charge. NOTE: Before using the hand drilling/ breaker machine diamond cutter shall be used all as directed by Engineer in charge.
Supply and fix GI tubing light grade 40 mm nominal dia in trench/ road/ pole for cable protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Copper cable flexible 1.5Sqmm 3 core 230 Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix weather proof street light junction boxes made out of Thermo plastic consisting of 4 nos of connectors of capacity 63 Amp, 415 Volt with proper closing arrangement, elmax connector for neutral link including pole mounting clamp with nut bolts, box shall have two cable entry complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing and commissioning of LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel fabricated out of 3.15 mm thick of size 1.50Mx1.50Mx0.45M (L X H X D ) and internal compartment shall be not less than 2mm thickness CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphate primer powder coated then painted with final coat of epoxy based powder coated, panel shall be having front and rear opening for installation of separate cable alleys with proper locking arrangement with bulbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended bus bar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided. Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items. The panel shall duly supported on angle iron of size 40x40x4mm thick,panel shall with and include following accessories:- (a) Bus bar chamber (4 nos TP&N 100 amp rating ) (Aluminium bus bar) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assy -03 No
(c) complete wiring of panel with suitable gauge multi stranded copper conductor with proper color code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. panel shall have separate chambers and suitable size of aluminium bus bar extensions for connecting cables including following switchgears/accessories:- i) MCCB TPN 63 A as incomer - 01 No , ii) MCCB TPN 32 A -02Nos iii) MCB TPN 16A to 32 A -03Nos(connected to out of contactor) iv) Contactor MNX 22, 4 pole,415 volts, 32 Amps - 01 No iv) Astronomical time switch day/weeks programmed with reserve 30 minutes - 01 No NOTE: (i) Contractor shall submit to Engineer-in-charge the general arrangement technical drawing and single line diagram of feeder pillar box for approval. (ii) Necessary PCC foundation and angle iron work required for fixing of feeder pillar box as directed by Engineer-in-charge shall deemed to be included in the quoted rates. (iii) Separate cable alleys shall be provided on right/left side of feeder pillar box to accommodate cable of sizes 3.5core 95Sqmm, 3.5core 50 Sqmm each 01 No and 4 core 16Sqmm -02 Nos.
Supply, Installation, Testing and commissioning of LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel fabricated out of 3.15 mm thick of size 1.50Mx1.50Mx0.45M (L X H X D ) and internal compartment shall be not less than 2mm thickness CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphate primer powder coated then painted with final coat of epoxy based powder coated, panel shall be having front and rear opening for installation of separate cable alleys with proper locking arrangement with bulbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended bus bar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided. Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items. The panel shall duly supported on angle iron of size 40x40x4mm thick,panel shall with and include following accessories:- (a) Bus bar chamber (4 nos TP&N 63 amp rating ) (Aluminium bus bar) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assy -03 No
(c) complete wiring of panel with suitable gauge multi stranded copper conductor with proper color code (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. Panel shall have separate chambers and suitable size of aluminium bus bar extensions for connecting cables including following switchgears/accessories:- i) MCCB TPN 32 A as incomer - 01 No , ii) MCCB TPN 25 A -01Nos outgoing further Panel iii) MCB TPN 25 A -02Nos one for Watch tower second one is Street light connected through contactor v) Contactor MNX 22, 4 pole,415 volts, 32 Amps - 01 No iv) Astronomical time switch day/weeks programmed with reserve 30 minutes, - 01 No
Earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead strip of size 25mm x 4mm up to 7.5 M distance and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm bore for watering, funnel with wire mesh, PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-30 (design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.03 of SSR Part-I(2009), connecting to earthing test point all as specified and directed including testing on completion. Note : The unit rate shall include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete. (ii) The unit rate includes for protection pipe and earth lead upto 7.50 meter.
Supply and fix in of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. using 25x4mm galvanized steel stripcomplete all as specified and as directed by Engineer-in-charge.
Schedule of Credit (Minus) Rs.89,489.00 NOTE: Bidder shall insert credit amount of Rs. 89,489.00 as rate in Green field under Col-5.
KDR CONSTRUCTION
devan enterprises
K P DIVAKARAN
Gates Infra Construction Co
Rama Electricals
SANDR
JEETH CONSTRUCTION
M/s.Rejoy Constructions
Neptune Engineers and Builders
ELAN ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .