Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 CrRejected-AOC | ₹1.8 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹1.8 CrRejected-AOC | ₹1.8 Cr | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | A.K.VARUN L1 | Velayudhan M L2 | LIPIN M V L3 |
|---|---|---|---|---|---|---|
| 1.00Hospital building | ||||||
| 1.00 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 509.06 | cum | 300 ₹1.5 L | 256 ₹1.3 L | 258 ₹1.3 L |
| 1.00 | 2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 137.81 | cum | 130 ₹17,915.30 | 130 ₹17,915.30 | 132 ₹18,190.92 |
| 1.00 | 50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete | 208 | hour | 350 ₹72,800 | 340 ₹70,720 | 346 ₹71,968 |
| 1.00 | 2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m | 320.82 | sqm | 300 ₹96,246 | 165 ₹52,935.30 | 167 ₹53,576.94 |
| 1.00 | 2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m | 47.44 | sqm | 200 ₹9,488.80 | 180 ₹8,539.92 | 183 ₹8,682.25 |
| 1.01 | OD182106/2025-2026:
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.Including chipping of extra depth of pile ete all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 800 mm dia piles (Note:Excess/less of extra cement used by the contractor is not payable/not recoverable separately as per circular No CE/BL/GL/6541/2015 dated 30/8/2017) | 188 | metre | 5,710 ₹10.7 L | 4,800 ₹9.0 L | 4,850 ₹9.1 L |
| 1.01 | OD182105/2025-2026:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. Including chipping of extra depth of pile ete . all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).1000 mm dia piles (Note:Excess/less of extra cement used by the contractor is not payable/not recoverable separately as per circular No CE/BL/GL/6541/2015 dated 30/8/2017) | 342 | metre | 8,039 ₹27.5 L | 6,650 ₹22.7 L | 6,660 ₹22.8 L |
| 1.01 | 20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity) | 2 | per test | 45,000 ₹90,000 | 38,200 ₹76,400 | 38,253 ₹76,506 |
| 1.01 | 20.6.2.1:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Single pile above 50 tonne and upto 100 tonne capacityInitial test (Test Load 2.5 times the Safe capacity) | 2 | per test | 45,000 ₹90,000 | 72,000 ₹1.4 L | 72,145 ₹1.4 L |
Tender Value
₹1.8 Cr
EMD Value
₹50,000
Closing Date
29 Oct 2025, 11:30 amClosed
Superintending Engineer
O/o Superintending Engineer, PWD Buildings Central Circle thrissur
GENERAL-Annual plan 2023-24- Thrissur District- Construction of new building for Govt. Ayurveda hospital,Guruvayur - Phase 1-Work- General Civil Work-1
2025_PWD_811462_1
PWD/BLDG/TR/19252/2025_5_1_1/1
Open Tender
Civil Works - Buildings
240 days
Guruvayur
Please refer Tender documents.
12 documents required · 12 mandatory
₹6,508
Yes
₹50,000
Yes
20 Jan 2026
18 Oct 2025
31 Oct 2025
18 Oct 2025
29 Oct 2025
18 Oct 2025
Amount
Hospital building
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m
OD182106/2025-2026: Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.Including chipping of extra depth of pile ete all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 800 mm dia piles (Note:Excess/less of extra cement used by the contractor is not payable/not recoverable separately as per circular No CE/BL/GL/6541/2015 dated 30/8/2017)
OD182105/2025-2026:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. Including chipping of extra depth of pile ete . all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).1000 mm dia piles (Note:Excess/less of extra cement used by the contractor is not payable/not recoverable separately as per circular No CE/BL/GL/6541/2015 dated 30/8/2017)
20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity)
20.6.2.1:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityInitial test (Test Load 2.5 times the Safe capacity)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
OD182104/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- The cement content obtained as per mix design shall be used by the contractor at site .All work up to plinth level. Note: Cement content considered in this item is @340 kg/cum. Excess/less of extra cement used by the contractor is not payable/not recoverable separately as per circular No CE/BL/GL/6541/2015 dated 30/8/2017)
OD182102/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- The cement content obtained as per mix design shall be used by the contractor at site .All work above plinth level up to floor V level . Note: Cement content considered in this item is @340 kg/cum. Excess/less of extra cement used by the contractor is not payable/not recoverable separately as per circular No CE/BL/GL/6541/2015 dated 30/8/2017)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
22.3:Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
OD182103/2025-2026:Supplying and fixing black granite stone of thickness 20mm including engraving letters,all kind of labour and material charges etc
Velayudhan M (BID ID -2415290)
LIPIN M V (BID ID -2415330)
Bidder Name
A.K.VARUN
Velayudhan M
LIPIN M V
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.06 MB
gst.pdf
Other Document • 0.40 MB
afdvt.pdf
Tender Documents • 0.03 MB
epayment.pdf
Tender Documents • 0.06 MB
GOS.pdf
Tender Documents • 0.20 MB
viewnit.pdf
Tender Documents • 0.04 MB
viewsbd.pdf
Tender Documents • 5.96 MB
pgt.pdf
Tender Documents • 0.34 MB
form.pdf
Tender Documents • 0.38 MB
integrity.pdf
Tender Documents • 0.01 MB
BOQ_1355032.xls
BOQ • 0.32 MB
itbx.pdf
Other Document • 0.17 MB
Download all tender documents and submit your bid