| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.4 LAdmitted-Finance 15 27 GALI NO 15 KH NO 152 WEST GONDA WEST DELHI NEW DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | -45.10% | ₹16.4 L | L1 | Admitted-Finance |
| 2 | L2₹17.0 LAdmitted-Finance C 344 GALI NO 2 BLOCK C WEST KARAWAL NAGAR DELHI 110094 | NORTH EAST | DELHI | 110094 | -43.11% | ₹17.0 L | L2 | Admitted-Finance |
| 3 | L3₹17.3 LAdmitted-Finance | -42.00% | ₹17.3 L | L3 | Admitted-Finance |
| 4 | L4₹17.4 LAdmitted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | -41.71% | ₹17.4 L | L4 | Admitted-Finance |
| 5 | L5₹17.6 LAdmitted-Finance | -41.11% | ₹17.6 L | L5 | Admitted-Finance |
Tender Value
₹29.9 L
EMD Value
₹59,821
Closing Date
27 Jan 2026, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
1) MOEI and fans, compound light and RMO pump sets, DG Set and AC equipments installed at Chief Electrol officer office, Kashmere Gate, Delhi. 2) MOEI and Fans and RMO Drinking Water Supply Pump Sets, Sub-Station and Distribution System DG S
2026_PWD_285169_1
199EEEPWDDHC,NDC2025-26Revised
Open Tender
Electrical Works
30 days
New Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹59,821
2 Feb 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
Servicing and overhauling of LT ACBs make L&T, ABB, GE, Schneider and C&S installed at various location under M-4513 including cleaning the dust & rust in the mechanical moving parts, operating mechanism, spring charging mechanism and Rack IN / OUT mechanism. Removing old stiff lubrication, applying fresh lubrication on the moving parts. Cleaning of the oxidation layer from the main / arching fixed / moving contacts, checking the ON / OFF operation, Rack IN & Out operation, Spring charging operation for smooth functioning of both electrical and mechanical systems, carrying out minor repairs. Finally megger testing and commissioning the ACBs to the entire satisfaction of site engineer. 800 TO 4000A
Servicing and overhauling of HT VCBs make Crompton Greaves, installed at various location under M-4513 including cleaning the dust & rust in the mechanical moving parts, operating mechanism, spring charging mechanism and Rack IN / OUT mechanism. Removing old stiff lubrication, applying fresh lubrication on the moving parts. Checking the ON / OFF operation, Rack IN & Out operation, Spring charging operation for smooth functioning of both electrical and mechanical systems, carrying out minor repairs. Finally megger testing, relay calibration and commissioning the ACBs to the entire satisfaction of site engineer.
Servicing and overhauling of Changeover switch upto 400A- 800A including cleaning the dust and rust, lubricating the latch mechanism for smooth closing and opening operation, cleaning of moving and fixed contact the tightening of nuts and bolts of termination.
Servicing and overhauling of Capacitor bank/ Panel including cleaning and checking of capacitors tightening of connection checking of capacitance of each capacitor of 25 KVAR capacitors. Tightening the nuts and bolts of terminals, including minor repairs and replacement of defective capacitors, also checking the APFC relay for smooth adjustment of power factor for proper functioning. 200 KVAR to 250 KVAR Bank
Servicing of power transformers 200 & 400 KVA, Dry Type 11 KV/433V, including cleaning the rust and dust tightening the nuts and bolts of doors and sheets covers, cable terminations, checking of temperature scanner, voltage adjustment, door limited switches and performing the following test: - i) Measurement of winding resistance ii) Insulation Resistance iii) Voltage Ration Test iv) Polarity Test v) High Voltage Test vi) Short Circuit Test vii) Dielectric Test viii) Magnetizing Test
Servicing of ON AN type Areva make 1000 KVA, 11 KV / 433V oil immersed transformer including checking conservator tank bocholz relay, OTI, WTI and oil level indicator temperature indicator radiaters checking of Two oil samples for BDV, checking and tightening the LT & HT terminations taking the IR value of the HT & LT winding i/c Dehydration of transformer oil of 1000 KVA transformer including taking oils samples and testing for BDV and filling of transformer oil complete as required at site.
Supplying & filling of duly dehydrated transformer oil required for top-up in the existing transformers etc complete as required.
Servicing and overhauling of AMF Panel Supply and Installation of following accessories in the existing LT panel i/c dismantling of old defective accessories i/c connection, testing, Commissioning etc.
Supplying and fixing of indicating light LED-RYB -220 VAC
Supplying and fixing of digital Multifunction Meter- (A, V, PF, KV AH, KV Arh etc.)
Supplying and fixing of press button
Supplying of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc complete as required. 13.01) 3.5 X 25 Sq.mm
13.02) 3.5 X 35 Sq.mm
13.03) 3.5 X 50 Sq.mm
13.04) 3.5 X 95 Sq.mm
13.05) 3.5 X 120 Sq.mm
13.06) 3.5 X 240 Sq.mm
13.07) 3.5 X 400 Sq.mm
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
BOQ_377232.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid