Loading…
Loading…
Tender Value
₹5.2 Cr
EMD Value
₹5.2 L
Closing Date
4 May 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer Medium Irrigation Project Division, Ankleshwar
CONSTRUCTION OF INSPECTION BUNGALOW AT KARJAN COLONY, TA.ANKLESHWAR DIST : BHARUCH.
292624
16 of 2025-26
Open
Civil Works - Buildings
Bharuch
7 documents required · 7 mandatory
₹12,000
Executive Engineer, Medium Irrigation Project Division, Ankleshwar
₹5.2 L
2 Apr 2026
2 Apr 2026
2 Apr 2026
4 May 2026
2 Apr 2026
NAME OF WORK: CONSTRUCTION OF INSPECTION BUNGALOW AT KARJAN COLONY, TA.ANKLESHWAR
DIST : BHARUCH.
BILL OF QUANTITIES
Percentage Rate Tender
Estimate Rate Amount
Item Description Unit
1 Excavation for foundation upto 1.5 m depth including 1038.73 Cum 203.83
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead. for Loose or
2 Excavation for foundation for depth from 1.5 m to 3.0 m 981.73 Cum 282.85
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead for
Dense or Hard soil
3 Providing and laying cement concrete 1:3:6 (1-Cement : 3- 119.55 Cum 2,965.76
coarse sand : 6- hand broken stone aggregates
mmnominal size) and curing complete excluding cost of
formwork in Foundation and Plinth
4 Providing and laying controlled cement concrete M.250 286.81 Cum 4,643.98
and curing complete including the cost of formwork and
reinforcement for reinforced concrete work in
Foundations, footings, Base of columns and Mass
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work in Columns, Pillars posts and struts, For Ground Floor
6 Filling available excavated earth (excluding rock) in 1414.32 Cum 130.39
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each
disposited layer by ramming and watering.
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work for Ground Beam and SOG Beam
8 Brick work using common burnt clay building bricks having 90.14 Cum 4,021.02
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)
(Conventional Brick)
(i) Half brick masonry in common brunt clay building bricks
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional
9 Filling in foundation and plinth with murrum or selected 616.96 Cum 289.06
soil in layers of 20cm. thickness including watering,
ramming and consolidating etc. complete.
10 Providing and laying controlled cement concrete M.150 for 147.97 Cu.m 4,271.29
curing complete including cost of formwork and excluding
cost of reinforcement for reinforced concrete work for
Providing and laying controlled cement concrete M.200
and curing complete including the cost of formwork and
reinforcement for reinforced concrete work in GF Staircase
12 Brick work using common burnt clay building bricks having 212.46 Cum 4,289.33
crushing strength not less than 35 kg./Sq.Cm. for GF
Cement Mortar 1:6 (1- Cement : 6 -fine sand)
(Conventional Brick)
13 (i) Half brick masonry in common brunt clay building bricks 177.25 Sqm 651.67
having crushing strength not less than 35 Kg/Sq.Cm. for GF
in Cement mortar 1:4 (1- Cement : 4 -coarse sand )
(Conventional Brick)
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
reinforcement for reinforced concrete work in SOG Slab
Providing and laying ordinary cement concrete 1:2:4 (1-
Cement 2- coarse sand : 4- graded stone aggregates 20 mm
nominal size) for R.C.C lintel including finishing smooth
with,curing etc. complete including the cost of formwork
but excluding the cost of reinforcement for Ground Floor
Providing and laying cement concrete 1:2:4 (1- Cement : 2-
Coarse sand : 4- graded stone aggregates 20 mm nominal
size) for reinforced concrete Chhajjas not exceeding 10cm.
thickness upto floor two level including finishing the
exposed surfaces with cement mortar 1:3 (1-cement, 3 Fine
sand) to give a smooth and even surface centering and
formwork and curing complete excluding cost of
reinforcement for Ground Floor
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work for RCC Walls in lift, Elevation
17 Providing TMT Bar FE 500D reinforcement for R.C.C. work 83511.86 kg 76.21
including bending, binding and placing in position complete
for Ground Floor
18 Providing and laying controlled cement concrete M.250 35.26 Cum 7,801.95
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work in Columns, Pillars posts and struts For SOG to
19 Providing and laying controlled cement concrete M.250 53.24 Cum 6,565.40
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work for Terrace Beam
20 Providing and laying controlled cement concrete M.200 2.67 Cum 6,801.74
and curing complete including the cost of formwork and
reinforcement for reinforced concrete work in Staircases
excluding landing for First Floor
21 Brick work using common burnt clay building bricks having 198.79 Cum 4,329.82
crushing strength not less than 35 kg./Sq.Cm. in Mortar 1:6
(1- Cement : 6 -fine sand) (Conventional Brick) for First
(i) Half brick masonry in common brunt clay building bricks
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional.First Floor
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
reinforcement for reinforced concrete work in Terrace Slab
Providing and laying ordinary cement concrete 1:2:4 (1-
Cement 2- coarse sand : 4- graded stone aggregates 20 mm
nominal size) for R.C.C lintel including finishing smooth
with,curing etc. complete including the cost of formwork
but excluding the cost of reinforcement.First Floor
25 Providing and laying cement concrete 1:2:4 (1- Cement : 2- 3.01 Cum 6,373.38
Coarse sand : 4- graded stone aggregates 20 mm nominal
size) for reinforced concrete Chhajjas not exceeding 10cm.
thickness including finishing the exposed surfaces with
cement mortar 1:3 (1-cement, 3 Fine sand) to give a
smooth and even surface centering and formwork and
curing complete excluding cost of reinforcement for First
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work for RCC Walls in lift, Elevation for First Floor
26 Providing TMT Bar FE 500D reinforcement for R.C.C. work 31377.51 kg 77.21
including bending, binding and placing in position complete
for First Floor
27 Providing and laying controlled cement concrete M.250 8.94 Cum 7,878.10
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work in Columns, Pillars posts and struts, for Terrace to
Stair cabin Top slab
28 Brick work using common burnt clay building bricks having 37.19 Cum 4,370.31
crushing strength not less than 35 kg./Sq.Cm. in Cement
Mortar 1:6 (1- Cement : 6 -fine sand) (Conventional Brick)
for Stair Cabin
(i) Half brick masonry in common brunt clay building bricks
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional.Stair Cabin Level
Providing and laying ordinary cement concrete 1:2:4 (1-
Cement 2- coarse sand : 4- graded stone aggregates 20 mm
nominal size) for R.C.C lintel including finishing smooth
with,curing etc. complete including the cost of formwork
but excluding the cost of reinforcement for Stair cabin
30 Providing and laying cement concrete 1:2:4 (1- Cement : 2- 0.34 Cum 6,411.46
Coarse sand : 4- graded stone aggregates 20 mm nominal
size) for reinforced concrete Chhajjas not exceeding 10cm.
thickness including finishing the exposed surfaces with
cement mortar 1:3 (1-cement, 3 Fine sand) to give a
smooth and even surface centering and formwork and
curing complete excluding cost of reinforcement. for Stair
31 Providing and laying controlled cement concrete M.250 6.69 Cum 6,603.48
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work in Stair cabin beam
32 Providing and laying controlled cement concrete M.250 69.31 Cu.m 6,142.92
and curing complete including the cost of formwork and
reinforcement for reinforced concrete work in Stair cabin
Providing and laying controlled cement concrete M.250
and curing complete including the cost of formwork and
excluding cost of reinforcement for reinforced concrete
work for RCC Walls, Lift, Parapet, Pardi Stair cabin level
34 Providing TMT Bar FE 500D reinforcement for R.C.C. work 11223.78 kg 78.21
including bending, binding and placing in position complete
for terrace floor and stair cabin
20mm thick sand faced cement plaster on walls upto height
10 metres above ground level consisting of 12mm thick
backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick
finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plastering and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) for Ground Floor
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for
plastering and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) for Ground Floor Ceiling
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plastering and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) for First Floor
39 Providing 15mm thick cement plaster in single coat on 756.81 Sq.m 214.60
Rough (Similar)side of single or half brick walls for
plastering upto floor two level and finished even and
smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) for
First Floor Ceiling
40 Providing 15mm thick cement plaster in single coat on 221.60 Sq.m 212.54
Rough (Similar)side of single or half brick walls for interior
plastering and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) Stair Cabin
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for
plastering and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) Stair Cabin Ceiling
42 Applying 2 coat of Primer Coat of approved brands on 2333.83 Sq.m 50.50
exterior surface with proper cleaning etc. Item to be
approved by engineer incharge or consulting engineer
43 Finishing walls with textured ( Rustic ) pattern on exterior 18.98 Sq.m 303.00
plastered surface pattern to be approved with consulting
engineer or Engineer Incharge
44 Finishing wall with weather proof exterior emulsion paint 2333.83 Sq.m 114.53
on wall surface (two coats) to give an required shape even
shade after thoroughly brushing the surface to remove all
dirt, and remains of loose powdered materials.etc
45 Applying two coats of putty & two coats of primer of 5564.85 Sq.m 40.59
approved brand and manufacture on new wall surface to
give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign
matter and sand papered smooth.
46 Wall painting (two coats) with plastic emulsion paint of 4399.24 Sq.m 78.90
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
Ceiling painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
Extra over item 57 for painting with plastic emulsion paint
of approved brand on ceilings and sloping roofs.
Supply and application of FREEFORM STONECRETE ( Vyara
Tiles or equivalent ) with 8-10 mm thickness with max
aggregate size 3-8 mm with compressive strength>
N/mm2, Flexural Strength > 3 N/mm2, Bulk density -1250
kg/m3, and 17% of total mix by weight ( water ) as directed
engineer incharge or consultant
Providing and fixing powder coated aluminium louvres
made from heavy duty extruded aluminium sections
conforming to IS 733 and IS 1285 or equivalent, comprising
heavy aluminium frame and louvre blades of minimum
mm thickness fixed at suitable angle for ventilation while
preventing entry of rainwater, finished with polyester
powder coating of approved shade with minimum 60–80
microns thickness, including fabrication, cutting, drilling,
fixing with stainless steel screws, anchor fasteners,
brackets, sealant and all necessary accessories, scaffolding,
labour, materials, tools and equipment required for proper
installation at site, complete in all respects and measured
in square metres of finished surface area.
Providing and fixing natural stone cladding for building
elevation using approved quality machine cut stone slabs
of required size and minimum 18–20 mm thickness, fixed
on external walls/elevation over backing surface with
suitable stainless steel cramps, pins or brackets and cement
mortar (1:4) as required to ensure proper anchorage,
including dressing of stone edges, maintaining uniform
joints, filling joints with white/grey cement slurry mixed
with matching pigment, scaffolding, curing and all labour,
materials, tools and accessories complete, conforming to
relevant provisions of IS 1597 (Part 1) and IS
complete in all respects and measured in square metres of
finished surface area.
Providing and laying Machine cut free edges machine
polished telephone black madras Granite stone slab 18mm
(Average ) thick ( Single Piece not more than 150cm) for
stair steps and risers & Door/window frame, top of parapet
as per design including full moulded round front steps &
1cm nosing & necessary groove on trads of steps ;laid on
20mm thick cement mortar 1:6 ( 1 cement : 6 coarse sand )
jointed with gray cement sluury including rubbing and
polsihing etc. complete.
Providing and Fixing door made up of 50 mm thickness (
19mm thick 2 nos Ply+12mm thick 1 Ply)both side
laminated and on both side 1 mm thick premium Laminate
with alll fixtures like aldrop,SS Handle,stopper,tadi,door
magnet, door stopper hinges, etc materials as per drawing
& as directed by engineer incharge.Item to be approved by
engineer incharge or cunsulting engineer
Providing and Fixing flush door both side laminated &
I.T.W. beading all around by using I.T.W. frame 120 mmX
80 mm shutter fabricated from 35 mm thick solid core
malemine faced three layered pre laminated flat pressed
wood based exterior grade bonded BWP/BWR synthetic
resin having stamped IS 12823 grade I type II including
three coats of lacquer polishing to exposed wooden surface
& stainless steel decorative type designs fixtures/ fastening
etc including I.T.W trinagular batten patti of size 30mm X
30mm etc as per architectural detailed drawing & as
directed by engineer incharge.
Providing and Fixing Sliding door with Flush Door Shutter
and 1mm thick laminate sheet along with Accessories like
wheel rail, channel, lock with labour, material and other
cost. Item to be approved by engineer incharge
Providing and fixing window having extruded aluminum
Colour anodized section frame main outer size 127mm x
38.10mm x 1.35mm @wt. 1.384kg/m, horizontal Four track
member size 122.20mm x 31.75mm x 1.10mm@ wt
kg/m, vertical member of size 122.20mm x 31.75mm x
1.50mm @1.398 kg/mt with sliding shutters of horizontal
member size 40mm x 18mm x 1.29mm@ 0.456kg/mt
,vertical member of size 40mm x 18mm x 1.29mm @
kg/mt with 5 mm thick transparent bronze colour tinted
float glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass fixing to frame
in 3 tracks and in one track mosquito net have to be fit as
per details etc complete for window.
Providing and fixing window having extruded aluminum
Colour anodized section frame main outer size 95mm x
24mm x 1.17mm (of Jindal Section no:2459 @ wt.of
Kg/mt), horizontal Three track member size 92mm x
31.75mm x 1.30mm (of Jindal Section no:8688,@ Wt.1.07
Kg/mt), vertical member of size 92mm x 31.75mm x
1.50mm (of Jindal Section no:8933,@ Wt. 1.06 Kg/mt) with
sliding shutters of horizontal member size 40 mmx18mm
x1.29mm (of Jindal Section no:8947@ wt.of 0.456 Kg/mt),
vertical member of size 40mm x 18mm x 1.29 mm (of Jindal
Section no:8949 @ wt.of 0.456Kg/mt/ with 5 mm thick
transparent bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and transparent
silicon sealant glass fixing to frame in two tracks and in one
track mosquito net have to be fixed as per details etc
Providing and fixing standared extruded of alluminium
section of size 63mm x 38.10mm x 1.2mm (Jindal Section
:2434, @ Wt. 0.643 Kg/mt) with colour anodized
alluminium frame for ventilation with 5 mm thick frosted
glass as details etc complete for Ventilation
58 Providing and fixing M.S. grills of required pattern to 6014.79 Kg 105.18
wooden frames/grenite frames of windows etc. with M.S.
flats at required spacings and frame alround, square or
round bars with round headed bolts and nuts or by screws
(A) Plain Grill.
59 Painting two coats (excluding priming coat) on new steel 200.49 Sqm 87.81
and other metal surface with enamel paint, brushing,
interior to give an even shade including cleaning the
surface an even shade including cleanicn the surface of all
dirt, dust and other foreign matter.
60 Providing and fixing frameless glass railing made of 79.52 Sqm 11,766.50
toughen glass ( 12 mm thick ) with rail guide on top at
every 2' C/C made up of 2" SS 304 pipe with all necessory
fixtures ( steel balustrades ), labour, material. Item to be
approved by engineer incharge
P & L 800mm x 1600 mm vitrified 9 mm thick tile flooring
over 20 mm (average) base of cement mortar 1:6 (
cement: 6 coarse sand) on new surface or fixing on existing
flooring by adhesive material including dismentaling of
existing flooring and jointed with color cement slurry
including finised with flush pointing & cleaning the surface
etc. complete for light shade Glossy. Item to be approved
by engineer incharge
62 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm 183.97 Sq.m 1,415.77
(average) base of cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including
finised with flush pointing & cleaning the surface etc.
complete for light shade. Item to be approved by engineer
63 Providing and laying coloured glazed tiles of the size 300 656.65 Sq.m 1,417.36
skirting, risers of steps and dedo on 10 mm. thick cement
plaster 1:3 (1 cement : 3 coarse sand) & jointed with white
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm
(average) base of cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including
finised with flush pointing & cleaning the surface etc.
complete for antiskit
Providing and laying broken chine mosaic flooring
over avg 40 mm C.C 1:2:4 bedding for maintaning slope for
plain and curve surface & 12 mm to 20 mm broken pieces
of glazed tiles to be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar creme out
upto surface using white cement including rounding off
junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
Providing and applying waterproofing treatment to toilet
sunken slabs by cleaning the surface thoroughly and filling
the slab with brick bat coba using broken brick bats laid in
cement mortar (1:4) mixed with approved waterproofing
compound such as Dr. Fixit / Fosroc / Sika or equivalent.
The brick bat layer shall be well compacted and finished to
the required slope towards the outlet. Joints and corners
shall be properly sealed, and a waterproof slurry coat of
cement mixed with waterproofing chemical shall be applied
before and after laying brick bats. The finished surface shall
be cured adequately and checked by ponding test for a
minimum of 48–72 hours to ensure complete
watertightness before laying the final floor finish. The work
shall be carried out complete with all materials, labour,
curing, and testing as per standard specifications.
66 Providing Sandwitch Type Platform Using 25mm thick 27.71 Rmt 3,764.27
Single Polished kotah stone 75 cm Width at Top Width
to 18 mm Thick Premium Black Grenite Stone at Top with
75 mm Width and Face Patta Maximum 3.0 Mtr Long In
Single Piece using Cement Mortar 1:4 ( 1 cement : 4 coarse
sand ) laid by 75 cm width & 75 cm High Resting On 25 mm
Thick One Side Polished kotah stone fixed in wallc Cement
Mortar 1:4 ( 1 cement : 4 sand ) at Bottom Polished Kotah
stone flooring including fixing grenite stone & cutting the
stone for Fixing suitable fixtures/ sanitary etc. if required
with Polished & Including Providing Premium Black
Polished Grenite Stone 16 to 18 mm Thick with round
Border the edge,cost of sink. S S Grating Jali for nahni Trap,
Brass Waste Coupline ,PVC Waste Pipe, Manking Grove in
67 Providing 0.75mt wide plinth protection including 171.84 Rmt 991.26
excavation in hard or dence soil and Laying C.C 1:3:6 (1
cement : 3 coarse sand: 6 brickbats/stone aggregates) in
foundation and on top including Curring fnishng etc.
Anti-Termite System:Providing and laying of permanent
piping technology anti-termite treatment before flooring
work by installing LLDP (Low linear density polyethylene)
tube of 8 mm O.D. & 6.4 mm 1.D. with inbuilt pressure
compensation chip every 30 cm interval in the tube, having
working pressure of 2 Kg/cm2 and release rate of
Itr/hour fixed by P-clips and nails. The LLDP pipe shall be
installed at the entire periphery of the building and at
internal network of building at a depth of 20 to 200 mm
under floor at every 2 to 3 mtr. c/c distance (adjusted as
per building layout ) & Ends of loop pass through a PVC
elbow of minimum 32 mm ID at junction box of wall and
floor level, entering into a steel reinforced grooved flexible
pipe of minimum 22 mm ID leading into junction box and
the loops shall terminate in junction boxes & test every
junction during injecting chemicals for termite control
treatment. The anti termite chemical Imidacloprid 30.5% SC
mix as per IS-6313 (part III) shall be injected by the pressure
pump diluted with water @ 10.5 ml/5 ltr of water at the
rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The contractor shall
submit approved line plan for piping system and junction
boxes dully approved by Engineer-in-Charge with bond of
year warranty.(i)Anti Termite chemical injected area
(Chemical injecting incl. labour cost)
69 Providing cement vata (10cm. x 10 cm. size) quarter round 806.61 Rmt 23.68
in cement mortar 1:1 including neat cement finishing,
watering etc. complete.
Providing and fixing wsh down water closet wall hung
matte finish outside and glossy inside (European type, W.C.
Pan) make cera/hindware/Kohler/Jaquar etc or similar with
integral P or S trap including jointing the trap with soil pipe
in Cement Mortar 1:1 (1-Cement : 1-fine sand) with Seal
and cover of size 510X365X380 mm. Item to be approved
by engineer incharge or consulting engineer
71 Providing and fixing 40mm Dual flush cock/valve make 12.00 Each 3,535.00
cera/hindware/Kohler/Jaquar etc or similar with Square
plate made up of ss 304 to control cock operation of
approved quality including fixing in pipe line etc. complete.
Item to be approved by engineer incharge or consulting
72 Providing and fixing Ultra Thin SS Rain Shower make 9.00 Each 6,060.00
cera/hindware/Kohler/Jaquar etc or similar of 300 mm size
in single flow, Item includes all labour, material,
transportation etc. Item to be approved by engineer
incharge or consulting engineer
73 Providing and fixing high flow single lever concealed 9.00 Each 8,080.00
diverter make cera/hindware/Kohler/Jaquar etc or similar
with diverter handle, Item includes all labour, material,
transportation etc. Item to be approved by engineer
incharge or consulting engineer
74 Providing and fixing 12 mm thick toughen glass with 54.95 Sqm 2,525.00
necessary fittings and item includes all labour, material,
transportation etc. Item to be approved by engineer
incharge or consulting engineer
Providing and fixing thin rim table top washbasin make
cera/hindware/Kohler/Jaquar etc or similar with single hole
for pillar tap with C.I. or M.S. brackets painted white
including sutting holes and making good the same but
excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin
550 mm x 380mm size x 110 mm. (i) In white
colour.a)Providing and fixing C.P. brass waste for washbasin
or sink. (A) 32mmdia. b)Providing and fixing M.I. fisher
union for washbasin or sink. (A) 32mm dia. c)Providing and
fixing pillar tap, capstan head, screw down high pressure
with screws, shanks and back nuts. (i) 15mm
dia.d)Providing and fixing brass screw down stop tap.(A)
15mm dia.e)Providing and fixing Rubber plug for sink or
Providing and fixing Kitchen sink make
cera/hindware/Kohler/Jaquar etc or similar with C.I. or M.S.
brackets, painted white including cutting holes in walls and
making good the same . (C) Vitreous China Sink.(i) 600mm x
450mm x 150mm size.with fittings(ii) Flat Back washbasin
550 mm x v 400mm size. (i) In white colour.a)Providing and
fixing C.P. brass waste for washbasin or sink. (A) 32mmdia.
b)Providing and fixing M.I. fisher union for washbasin or
sink. (A) 32mm dia. c)Providing and fixing pillar tap, capstan
head, screw down high pressure with screws, shanks and
back nuts. (i) 15mm dia.d)Providing and fixing brass screw
down stop tap.(A) 15mm dia.e)Providing and fixing Rubber
plug for sink or wash basin.
Providing and fixing wall-hung vitreous china urinal of
approved make such as Hindware / Jaquar / Parryware or
equivalent, white glazed finish, size approximately 560 mm
× 350 mm × 300 mm (H × W × D), complete with CP brass
spreader, 32 mm dia flush pipe, inlet connection, waste
coupling, and all necessary fittings. Urinal shall be fixed to
wall with suitable brackets/bolts at required height,
including connection to water supply and waste line,
testing for proper functioning, and making good the wall
surface complete as directed by Engineer-in-Charg
78 Providing and fixing Bib Cock ( Bib Tap ) make 4.00 Each 2,020.00
cera/hindware/Kohler/Jaquar etc or similar with wall flange
& aerator. Item includes all labour, material and other cost.
(ii) 15mm dia. Item to be approved by engineer incharge
Providing and fixing 2-way bib cock / angle valve with
health faucet of approved make such as Jaquar / Hindware
/ Parryware or equivalent, made of high quality chrome
plated brass, wall mounted, 15 mm nominal bore, with
dual outlet arrangement for water supply and health faucet
connection. The item shall include ABS/CP health faucet
with 1.0–1.2 m long flexible hose pipe, wall hook, and all
necessary fittings, complete with fixing, testing and making
good the wall surface as required, all complete as directed
by Engineer-in-Charge
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions
total weight of cover with frame to be not less than 38Kg.
(Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation concrete 1:5:10
inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and
bed concrete etc. complete.(i) Inside dimensions 455mmx
610mm and 450mm deep for single pipe line.
Providing and fixing S.W. gully trap with C.I. grating brick
masonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps. (A) 100mm x 100mm size P type.
82 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 31.00 Each 558.36
100 mm diameter with jali of the following nominal
diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making
good the walls.
83 Providing laying and jointing in true line and level 15mm 122.40 Rmt 72.65
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall
be fixed on the wall with the help of clamp at every two
metre C/C or shall be concelled as directed including
necessary fittings etc. including testing of pipe and joints
84 Providing laying and jointing in true line and level 25mm 161.12 Rmt 91.84
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall
be fixed on the wall with the help of clamp at every two
metre C/C or shall be concelled as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
85 Providing laying and jointing in true line and level 40mm 182.07 Rmt 148.12
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall
be fixed on the wall with the help of clamp at every two
metre C/C or shall be concelled as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
Dia. Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including making
good the wall ceiling and floor 75 mm Dia
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
Dia. Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including making
good the wall ceiling and floor 110 mm Dia
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
Dia. Low densidy, complete with special falnge
compression type fittings, wall clipsetc. including making
good the wall ceiling and floor 160 mm Dia
89 Providing and fixing Gun metal check or non-return fullway 15.00 Each 420.63
wheel valve.(C) 25mm dia.
90 Providing and fixing Gun metal check or non-return fullway 4.00 Each 663.43
wheel valve.(E) 40mm dia.
91 Providing and fixing 600mm x 450mm bevelled edge 17.00 Each 833.73
mirrror of superior glass mounted on 6mm thick A.C. sheet
or plywood sheet and fixing to wooden pluge with C.P.
brass screws and washers.
92 Providing and fixing C.P. brass towel rail comlete with C.P. 17.00 Each 603.19
brass brackets fixed to wooden plugs with C.P. brass
scews.(B) 600mm x 20mm size.
93 Providing and fixing C.P. brass shower rose with 15mm or 9.00 Each 282.16
20mm inlet.(A) 100mm dia. Each
Providing and fixing Chicken mesh jali 16X24 (22 gauge) at
the junction of 2 different surfaces of different material
component at the time of plastering to prevent cracking in
plaster surface as and where directed at all floors with all
leads and lifts etc.complete.
95 Providing and fixing Jet spray heavy duty with S.S. Braided 12.00 Nos. 308.99
hose 60 cm long
96 Providing and fixing toilet paper holder.(A) C.P. Brass 12.00 Each 418.68
Providing & Installation of Kitchen furniture of any size
made of 19mm ply ,(BWP Playwood -IS ;710USED) with
outer most Ply having 0.9 mm laminate confirming IS
2046:1995 and inner Ply having regular 0.9 mm thick
laminate confirming IS 2046:1995 with required numbers &
size Handle made of SS etc. at any position in furniture
made up on site as per architects drawing finished without
laminets/veneer ,as per architect's instruction .Rate
includes all joints of ply have to be fixed with S.S screws ,S.S
nails , anti termite treatment ,synthetic resin Adesives
,sticking tapes etc.complete. Items to be approved by
engineer incharge
98 Earthwork for embankment including breaking clods, 6480.00 Cum 337.34
dressing with all lead and lift (including watering ) From
Borrow area within 10.0 Km. lead
Rolling of earthwork in layers with power roller including
filling in depressions which occur during the process.
Providing and fixing pre-cast concrete kerb stone of gray
cement based concrete block 30cm length,30cm height and
15cm thick of M200 grade concret as per approved design
and including excavation for fixing in proper line and
level,filling the joint with C:M 1:3 (1cement:3fine sand) etc
Pro. And fixing single layer water proof gypsum board
mm thick sections using water proof board of size 1220 mm
x 1830 mm x 8.0 mm suspended by GI suspender channel
of size 25 mm x 3 mm with intermediate channel og size
mm x 40 mm x 0.8 mm at 1220 mm center to center ceiling
section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c
and perimeter channel A of size 20 mm x 27 mm x 30 mm x
0.5 mm at edges & drops incl.paper tap sand sofit cleat,
anchor fastener, scoch bolt connecting cleat,joining
compound top coat on ceiling incl.making necy.opening for
light fitting,diffuser etc. comp. as per detail drawing as
102 ROLLER BLINDS 229.68 Sqm 4,545.00
Providing and Fixing Roller blinds as approved shade &
fabric.the blind shall be made out of extruded aluminium
alloy of 48mm outer dia. With a minimum wall thickness of
1.1mm duly anodised for long life. The tube shall be
designed with support ribs to keep it straight and shall
have a pocket for holding the fabric in position. the
operating mechanisium shall consist of a gear with spring
booster. the mechanisium shall be designed using high
strength fibred glass reinforced polyster assembly and
high carbon steel spring to transmit motion from
driving to driven members. the min. spring torque shall be
16kg per cm to ensure ultra smooth operation of blinds of
up to 3m width and 4m drop. the mechanisum shall
operate with the use of an endless beaded chain. the
endless chain shall be made from 2.3mm polyster cord with
7mm beads. the pitch of the chain shall be 13.5 mm.
an optional stopper shall be provided for stoping the blind
at desire position.idler shall be high strength fibreglass
reinforced polyster consisting of an outside sleev and
centre shaft. sleeve shall provide bearing surface for the
roller tube and provide bearing surface for the roller
tube and rotate freely on the centre shaft, providing
smooth, quiet and long wearing operation. brackets shall
be of optmised steel powder coated to give superior
Providing and fixing concealed center point to wall ceiling
& floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete.[A] 15 mm.
Providing and fixing interior wall panelling consisting of
framework made of seasoned hardwood battens /
aluminium / GI framing of suitable size fixed to wall with
approved fasteners, including necessary alignment and
spacing to receive panelling boards. The framework shall be
covered with 12 mm thick plywood / MDF board of make
Greenply / CenturyPly / Action TESA or equivalent, finished
with approved decorative laminate of make Greenlam /
Merino / CenturyLaminates, including adhesive, screws,
edge beading, mouldings, polishing or laminate finishing as
required. The work shall include cutting, jointing, grooves,
preparation of surface, filling of gaps, sanding and finishing
complete, including all labour, materials, tools and
incidentals required to complete the wall panelling work in
all respects as per approved drawings and directions of
Engineer-in-Charge.
Providing and fixing pre-cast Rubber Dye / steel Dye inter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 :
including 35 mm Sand layer for levelling and filling the joint
with sand in proper line and level as per guidlines of IRC :
SP 63-2018 etc. Complete.
Providing & Installation of Cup board of size made of 19mm
ply ,(BWP Playwood -IS ;710USED) with outer most Ply
having 1.0 mm laminate confirming IS 2046:1995 and inner
Ply having regular 1.0 mm thick laminate confirming IS
2046:1995 having required number of drawers of different
sizes & heights with necessary handles and locks of
different in size etc. & having 2 sliding door of aluminium
track on top and bottom with surface mounted door
handle at any position in furniture made up on site as per
architects drawing finished .Rate includes all joints of ply
have to be fixed with S.S screws ,S.S nails , anti termite
treatment ,synthetic resin Adesives ,sticking tapes
etc.complete. Items to be approved by engineer incharge
Providing & Installation of Cup board made of 19mm ply
,(BWP Playwood -IS ;710USED) with outer most Ply having
1.0 laminate confirming IS 2046:1995 and inner Ply having
regular 1.0 mm thick laminate confirming IS 2046:1995
having drawers of different sizes with necessary handles of
different sizes and locks etc. & having required number of
doors with required number of door handle at any position
in furniture made up on site as per architects drawing
finished .Rate includes all joints of ply have to be fixed with
S.S screws ,S.S nails , anti termite treatment ,synthetic resin
Adesives ,sticking tapes etc.complete. Items to be approved
by engineer incharge
Providing & Installation of Kitchen cabinet with 5 kg
hydraulic gas spring soft close made of 19mm ply ,(BWP
Playwood -IS ;710USED) with outer most Ply having 1.0 mm
laminate confirming IS 2046:1995 and inner Ply having
regular 1.0 mm thick laminate confirming IS 2046:1995
having 5 mm thick fluated glass on front with aluminium
shutter profile at any position in furniture made up on site
as per architects drawing finished .Rate includes all joints of
ply have to be fixed with S.S screws ,S.S nails , anti termite
treatment ,synthetic resin Adesives ,sticking tapes
etc.complete. Items to be approved by engineer incharge
Providing & Installation of Kitchen cabinet made of 19mm
ply ,(BWP Playwood -IS ;710USED) with outer most Ply
having 1.0 mm laminate confirming IS 2046:1995 and inner
Ply having regular 1.0 mm thick laminate confirming IS
2046:1995 having 5 mm thick fluated glass on front with
aluminium shutter profile at any position in furniture made
up on site as per architects drawing finished .Rate includes
all joints of ply have to be fixed with S.S screws ,S.S nails
anti termite treatment ,synthetic resin Adesives ,sticking
tapes etc.complete. Items to be approved by engineer
Providing & Installation of TV Unit made of 19mm ply
,(BWP Playwood -IS ;710USED) with outer most Ply having
1.0 mm laminate confirming IS 2046:1995 and inner Ply
having regular 1.0 mm thick laminate confirming IS
2046:1995 with necessary partitions and handles in
required in size etc. at any position in furniture made up on
site as per architects drawing finished .Rate includes all
joints of ply have to be fixed with S.S screws ,S.S nails , anti
termite treatment ,synthetic resin Adesives ,sticking tapes
etc.complete. Items to be approved by engineer incharge
Providing and fixing Mangalore pattern clay tiles of
approved make such as Mangalore Tiles or equivalent, size
approximately 400 mm × 250 mm, for elevation cladding,
fixed over a framework of MS angles / vertical and
horizontal battens (minimum 25 mm × 25 mm or as
required) securely anchored to the wall with suitable
fasteners and holdfasts. The work shall include providing a
waterproof backing layer using polymer modified
waterproof coating / waterproof membrane over the wall
surface prior to fixing the framework to prevent seepage.
Tiles shall be fixed with GI screws/hooks and binding wire
maintaining proper alignment, uniform overlap, and
spacing as per approved pattern. The item shall also
include necessary cutting of tiles, corrosion protection to
MS members with primer and paint, sealing of joints where
required, scaffolding, and all labour and materials,
complete to achieve a neat architectural finish as per
drawings and direction of the Engineer-in-Charge.
112 Providing erecting and fixing double coated ISI water tank 4.00 Sqmtr 3.95
of required capacity each with all necessary fittings and
connection etc. complete on terrace
113 Providing and fixing 1 Hp Pressure booster pump of brand 4.00 Each 30,300.00
equivalent to Kirloskar with automatic water level
controller of brand equivalent to Crompton including all
electric wire and connection material and labor for fixing
with existing pipe connection and tank etc with all lead and
114 Excavation for foundation upto 1.5 m depth including 6.00 Cu.m. 268.28
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter
lead.(B) Dense or Hard soil
115 Excavation for foundation for depth from 1.5 m to 3.0 6.48 Cu.m. 289.92
m including sorting out and stacking of useful
materials and disposing off the excavated stuff upto
50 Meter lead.(B) Dense or Hard soil
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)
(Conventional Brick) For Honey Comb Work
117 Filling in foundation and plinth with brick Bats Chhara 4.18 Cu.m. 615.57
in layers of 20cm. thickness including watering,
remming and consolidating etc. complete. With 5 km
118 Supplying Kapchi of 25mm to 40mm with 5 km lead 1.36 Cu.m. 469.65
119 Suppplying B.T. Kapchi 10mm to 20mm size with 5 2.16 Cu.m. 569.45
120 Suppplying coarse sand with 5 km lead… 6.48 Cu.m. 289.14
121 Drilling bore 175mm dia upto 35mt depth… 35.00 Rmt. 353.50
122 Providing & Installation of UPVC casing pipe of 6" 35.00 Rmt. 1,079.77
123 Labour charges for filling kapchi / Grit brick bat/ sand 1.00 Job 1,010.00
etc in layers as directed…
124 Preparing structural design of RCC Under Ground / 20000.00 Ltr. 5.98
Partially under ground / above high ground level
Reservoir of required capacity as per relevant I.S.
standards and Constructing the same, including
excavation in all types of soil strata (including rock)
including shoring strutting if required, for loose soil /
to protect from collapse, casting 100 mm thick P.C.C.
levelling course in M- 15, Refilling the pit with proper
soil and disposing of the surplus stuff at all lead.
Including cement plaster in CM 1:2 with approved
water proofing compound to all over inside container
(i.e. walls, base, top slab/dome bottom etc. all).
Including all types of labour and material charges of
lowering, laying, erecting / hosting and jointing of
pipe assembly to inlet, outlet overflow, washout and
bye pass arrangement as per hydraulic design.
Providing and fixing accessories, CI Manhole frame
and cover, water level indicator, adequate cowl type
ventilators or lantern type ventilator with stainless
steel jail. RCC chambers for valves. Providing and
applying three coats of cement paint / snowcem to
the out side face of structure. It also includes
satisfactory water tightness test as per relevant I.S.
code and painting name of scheme and capacity on
the tank as per direction of engineer in charge.
List of Indian Standards for Design of GSR / SUMP:-
The structural design of GSR shall be in accordance
with provisions relevant I.S standards (1) I.S.
part I & II 2009 or Its latest revision (1.1) I.S.
part III & IV 1965 or Its latest revision (2) I.S. 456 –
2000 or Its latest revision. (3) I.S. 1893 – 2000 –
or Its latest revision. (4) I.S. 875, Part – 1 to 3, 1987 or
Its latest revision.
General Specifications:- (1) Water depth in container
shall be adopted as per data of tender. Capacity shall
be calculated excluding free board of the reservoir. If
water depth is not specified, the suitable water depth
/ acceptable to field engineer in accordance with
hydraulic requirement (2) Shape of container (in
plan)specified by in data shall be adopted in absence
circular shape shall be adopted (3) Size shall be fixed
as per availability of space (land area) at site /
acceptable engineer in charge. (4) Effect of
overlapping of pressure bulbs on soil due near by
structure and proposed sump should be considered.
(5) Care shall be taken that no damage should occur
to nearby existing structure. Compensation shall be
paid for the same by agency. (6) The minimum
concrete grade for RCC shall be M-30. (7) HYSD Fe
415 / 500 grade reinforcing bars confirming to I.S.
1786 / 1139 shall be considered in design. CRS / TMT
bars shall be provided. In saline atmosphere
corrosion resistance stainless steel / HCR rebar shall
be provided. Any other steel can be used with
approval of C.E./ in situation of non availability in
market without extra cost.
(8) Minimum size (or thickness) of various
components shall be provided as per tender criteria /
specifications in absence as per I.S./ Std. practice of
G.W.S.S.B. Minimum dimensions specified for various
components in tender data / specifications shall be
provided without fail. (9) The safe bearing capacity
(SBC) shall be referred from SBC test report. In
absence of report it shall be referred from data sheet.
If poor soil is found / water table is met with during
excavation SBC shall be scientifically ascertained and
design shall be revise. No extra shall be paid for
increase in quantity. (10) DI pipes and special shall
only be used if type is not specified in tender. (11)
The rate shall include cost of dewatering during
excavation making all arrangement when water table
meets within depth.
(12) The structure shall be designed properly to resist
uplift due to ground water table specified in data or
actual ground water table meets with during
excavation. If GWT / Uplift is mentioned in tender
and during excavation it dose not meet 7.5% rate
shall be reduced. (13) SS pipes railing shall be
provided over sump perifery when sump height is ≥
1.5 meter above ground level. (14.a) RCC
staircase/RCC Steps should be provided from GL to
sump top slab based on the height of the GSR
above/below the ground. (14.b) RCC Staircase with SS
railing to be provided inside reservoir container. BB
Masonry staircabin to be provided to cover the same
with MS safety door having locking arrangement. (15)
Appearance of structure should be aesthetically good
looking acceptable to authority. (16) Any change in
size, shape, depth below GL, height above GL, water
depth, F.B., size of member etc can be permitted in
exceptional case due to site condition or hydraulic
design requirement by C.E. No extra shall be paid for
(17) Any change in data, dimensions, shape, water
depth, reduction in size if permitted by competent
authority and if it reduces quantity then payment
shall be reduced prorate. (18) When capacity of GSR /
Sump is > 20 lakh litres two or suitable compartments
acceptable to executive engineer shall be designed
and provided. (19) Agency shall engage qualified (at
least graduate) consulting engineer for designing the
structure and he / she shall visit the site for guidance
of work. (20) 75% part rate shall be payable for
concrete, reinforcement and plastering items of
container until satisfactory hydraulic testing for water
tightness is performed as per tender condition. Till
the work shall be treated as incomplete. Above
conditions / general specifications Sr. No. 1 to 20 are
part and parcel of tender (contact) and prevail over
other provisions in tender. D) As above rectangular
sump with water table (Sub soil water level above
foundation) 1) 20000 Ltr Capacity Cost of 20000 Ltr
Point wiring for Light / Bell with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to
10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as
directed. (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete Cat.
Point wiring for Fan/Exhaust with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires up to
10 mtr length, in below type of pipe erected with 6A
Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with
earth continuity of following type erected on PVC /
Metallic/ Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
Point wiring for on board Looped Plug with 6A Modular
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected
on / in wall / ceiling with following type accessories Cat. III
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire
from nearby switchboard/mcb db board
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.
[III] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu.
Wire with 2.5 sq.mm ( green) earthing wire from mcb d b
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu.
Wire with 2.5 sq.mm ( green) earthing wire from mcb d b
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Providing following type of Modular Type Accessories
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front
plate , modules erected with necessary connections as per
site situation directed by Engineer In charge. (3) Two Pin/RJ-
11 Telephone Socket [A] For One Gang- Cat. III
132 (4) TV Co-axial Socket outlet [A] For One Gang- Cat. III 14 Each 160.59
133 (11) 6 Amps. Bell Push 9 Each 151.50
134 (20) Modular Buzzer 9 Each 149.48
Providing and erecting Sheet Steel powder coated Vertical
MCB distribution board (VTPN) - flush / surface mounted
double door (IP54) fitted with copper insulated busbar,
isolated neutral bar, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3, suitable for 63/100 AMP TPN
MCCB + RCCB as incomer and three phase outgoing as per
following .(The DBs should be used of same company of
MCB to be used) (B) 6 way outgoing
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for
(B) three phase incoming and single phase horizontal type
outgoing Per phase isolation type (PPI)
(b) sheet steel double door
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing (b) sheet
steel double door (IP-43) (iii) 8 way
138 diito as above but (iii)12 way 4 Each 1,492.78
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 35 KA.
at 415 V. having Normal current rating 200A.with variable
Thermal & magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.housing
Providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component for
following Max. rating erected as directed. (iii) 63 Amps. FP
141 diito as above but (ii) 40 Amps. FP 3 Each 2,637.11
providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic
of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max.
rating erected as directed (ii) 40Amps. DP
143 diito as above but (i) 25Amps. DP 5 Each 1,969.50
144 Providing & erecting 415 V MCB three Pole for Motor & 1 Each 716.09
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following
capacity (c ) 63 Amp.
145 diito as above but (b) 40 Amp. 3 Each 647.41
providing and erecting Miniature circuit breaker single pole
6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat. III
147 Providing & erecting 240 V MCB double pole switch for 4 Each 330.27
motor & inductive load (C Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp.
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 80 mm having 80-200 Micron galvanising, Inner
pipe dia of 40 mm having 200-250 Micron galvanising,
connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with
high charge dissipation suitable for following type of
applications with chamber and heavy duty
cover.(approved make OEM has to submit test certificate
including value of earth resistane of installation. [A] For
electrical installation up to 440 V Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs.
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.9, THD < 15%, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt, LED driver efficiency >
85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Tube
Light with integral driver (iii) 18-20 Watts, Surge - 2KV,IP-
20, conventional 4 feet Cat. III
Supplying and erecting led lamps with following wattage
capacity of 220 to 240 voltage, minimum 15000 burning
hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5 (A) LED Lamps integral type, with PC
diffuser suitable LAMP holder (iii) 10 to 15 watts
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/ CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion
resistance with diffuser housed in aluminium casted body
with company mark/name 160V to 270V,Power Factor
more than 0.9, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency >
85 % (fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Square/
Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV - Cat III
152 (H) Mirror Light 9 Watts, wall mounted minimum 1 feet 8 Each 312.09
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminium
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
< 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
protection. (ii) 15 to 24 Watts
Providing & erecting Approved make Power Saving 50 Watt
Ceiling Fan with double ball bearing ISI mark with
Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete
having 3blades with aluminium blades with , canopy &
cm. down rod erected with earthing.(Make shall be
approved by Engineer in charge)
155 Providing & erecting fresh air fan 250 mm dia with square 13 Each 1,559.44
frame make of ABS body with louvers - Cat. II
156 Supplying & erecting single phase approved make industrial 1 Each 3,339.06
exhaust fan suitable for medium duty ring mounted low
noise operation suitable for medium duty having following
dia size and maximum speed in RPM [D] 450 mm dia
Providing and erecting approved make split air-
conditioning unit consisting of copper condensing unit with
fan motor, hermetically sealed rotary compressor with
accessories etc. duly connected separately erected
evaporating unit and blower motor with its accessories by
means of extra supplied proper insulated copper
tubing,drain PVC pipes suitable for ( cost includes powder
coated Stand, Eco Friendly green gas charging, 15A plug top
& Remote Control) with necessary core cutting. (1) For
ISEER Range (KWH/KWH)(3.1 to 3.99) (b) for 1.5 ton
Supplying and erecting horizontal / vertical mounting type
storage water heater with copper container housed in
M.S./S.S./ABS body insulated with glass wool/puff
complete with heating elements,adjustable thermostats
300C to 850C, indicating lamp, safety valve, fusible plug,
etc.complete erected with coach bolts, nuts. washers &
cementation (A) 10 Ltr. with 3 KW. heating element Cat.III
159 providing and erecting Mains with 1.1 KV grade FRLS PVC 60 RM 200.99
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (A) With medium class Rigid PVC pipe and
accessories (e) 3 wire 6 sq. mm
160 ditto as above but (f) 3 wire 10 sq. mm 100 RM 325.22
(use earth wire of 4 sq.mm )
161 ditto as above but 4 wire 10 sq. mm 60 RM 425.21
(use earth wire of 4 sq.mm )
162 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 20 RM 183.82
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (A) 3 1/2 core 25 Sq. mm (
16 Sq. mm 1/2 core)
163 ditto as above but (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 50 RM 378.75
164 Supplying and erecting insulated pair of soft copper tubing 100 RM 965.56
open or concealed including power and control
cable,necessary PVC drain pipes for Split AC machine up to
Supplying and fixing 55-inch Ultra HD LED Smart Television
with wall mounting bracket, including necessary power and
HDMI connectivity arrangements, complete in all respects.
The TV shall be of reputed make such as Samsung / LG /
Sony or equivalent approved, having minimum 4K Ultra HD
resolution, smart TV features, Wi-Fi connectivity, HDMI and
USB ports, supplied with original remote control and
Supply, installation, testing and commissioning of IP based
CCTV camera (Dome/Bullet type) having minimum 2MP /
4MP resolution, with IR night vision range up to 30 m,
minimum 1/2.8" CMOS sensor, H.265 video compression,
wide dynamic range (WDR), built-in IR LEDs, IP66
weatherproof housing (for outdoor cameras), complete
with mounting accessories, connectors, and required
fittings. Camera shall be of make Hikvision / Dahua / CP
Plus / Honeywell or equivalent approved.
Supply and installation of NVR suitable for minimum 8 /
channel IP cameras, supporting H.265 compression,
HDMI/VGA output, remote viewing capability, USB ports,
LAN connectivity and recording management software,
including all accessories complete. NVR shall be of make
Hikvision / Dahua / CP Plus or equivalent approved.
168 Supply and fixing of surveillance grade hard disk of 1 Each 15,150.00
minimum 4 TB / 6 TB capacity compatible with NVR for
continuous recording, suitable for 24×7 operation. Hard
disk shall be of make Seagate / Western Digital or
equivalent approved.
169 Supply and fixing of LED monitor (minimum 22"/24") with 1 Each 10,100.00
Full HD resolution for live viewing and playback of CCTV
cameras including HDMI cable and accessories. Monitor
shall be of make LG / Samsung / Dell or equivalent
170 Supply and laying of CAT-6 UTP cable for CCTV networking 300 Meter 35.35
including dressing, clamping and termination complete.
Cable shall be of make D-Link / Molex / Finolex / Havells or
equivalent approved.
Supply and installation of 8/16 port PoE network switch for
powering IP cameras and network connectivity including
adaptor and accessories complete. Switch shall be of make
TP-Link / Cisco / D-Link or equivalent approved.
172 Supply and installation of 12V DC power supply unit / SMPS 8 Each 4,545.00
for CCTV cameras including distribution box and wiring
complete. Power supply shall be of make CP Plus / Hikvision
/ Matrix or equivalent approved.
173 [1] GEAR LESS LIFT DRIVE (MRL) comprising of High 1 Each 9,72,076.52
Starting torque Lift 3 phase 440 V A. C. Permanent
Magnet Synchronous motor of proper rating with
high efficiency shall be used.[2] Micro processor
based / PLC, ACVVVF, vector control drive with
encoder feedback closed loop system shall be used
for lift car and door operation which shall be full
collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal relay and
safety controls.
[3] Car with M S platform with bracings of adequate
size and to sustain the impact load cabin + passenger
with safety factor of fire for steel and side panels of
Stainless steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of s/s
chaker plate design sugeested of engineer in charge.
of engineer in charge. Car doors shall be of stainless
steel grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also be S.S.
304 finished with emergency stop device, mechanical
door safety device, facility of auto/ attended mode.
All car panel buttons and all floor switches must be
with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour
shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of
with key holes and infrared curtains with Unlocking
facility from outside
[5] Appropriate battery operated emergency light in
the car along with alarm switch shall be provided.
Also, Emergency Light & Fan should start immediately
without any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual
Rescue Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open
till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic
sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and
safety parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and
submission of calibration certificate submission, door
key holes in the floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should
be provided by the lift agency, along with the other
steel structure works, foundations for the machine
[16] In the hoist way fascia plate shall be provided
without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring with necessary safety devices
like RCCB in all circuit, Over Voltage Under Voltage
protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of
light points, with fixtures, exhaust fan and plug points
shall be provided by the agency. Only 3 phase Power
Supply shall be made available by department in lift
machine room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without
any extra cost. (granite/marble fixing around all
landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all
necessary permission from lift inspector and other
authorities. [20] acrylic transparent
licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after
lift erection and provide report by third party
authorized by concern licensing authority 5.agency
has to provide third party insurance upto completion
of free maintenance period and submit the document
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly
visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should
be provided at appropriate height on the Rear & Side
Wall Panels in Lift Car. [23] With Necessary KVA
rating voltage controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required
for lift is in scope of work which rating is sugested by
CEICED Department (electrical Inspector)
4/5/6 Passengers, Ground plus 1 upper floor with
Rated Speed of 1.0 m/sec,
(B) With General Specification attached herewith.
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having
200-250 Micron galvanising, connection terminal dia
of 14 mm with constant ohmic value surrounded
by highly conductive compound with high charge
dissipation suitable for following type of applications
with chamber and heavy duty cover.(approved make
OEM has to submit test certificate including value of
earth resistane of installation.
[A] For electrical installation up to 440 V Length of
Back filling compound - 1 Nos. of Bag of 15 Kgs.
175 Supply, Installation, Testing & Commissioning of 1 Each 42,455.35
following size of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall
Profile, Front Cover : High Transmission Low-Iron
Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module
Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed
with Bypass diodes, 100% Electroluminescence test
to ensure error free Modules, Thep. temp. co-
efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill
factor 75% to be used. Unit Production:- More than
4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year
Product warranty and 25 year Linear Power Warranty
includes all mechanical and electrical parameters of
the Solar panel. Modules must be complied to the
DCR(Domestic content requirements). The Ration of
AC to DC is 5:6 for the Installation capacity which are
given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V
, Max efficiency: 97.5% - 98.9%, O/p Frequency:
50/60Hz, Operating Altitude (m) ≤4000, O/p Power
Factor: ~1, O/P THDi: <3%, Operating Tempreture
Range: -25~60°C, Integrated protection of Inverter
are Anti-islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground
Integrated, Input Reverse Polarity Protection
Integrated, Insulation Resistor Detection Integrated,
Residual Current Monitoring Unit Integrated, Output
Over Current Protection Integrated, Output Short
Circuit Protection Integrated, Output Over Voltage
Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication:
GPRS / Wi-Fi, Module Mounting Structure: The
mounting (Rectangular pipe / square pipe / circular
pipe) with requisite cross bars, nuts and bolts, etc.
shall be Hot deep galvanized with minimum
80micron coating. The Rectangular / square /circular
hollow pipe section used for the structure should
have a minimum thickness of 2.0 mm. other than
above, the material thickness should be minimum
mm. A certificate of a structural engineer certifying
the strength and stability of the mounting structure
to withstand the weight and wind speed of
km/hour throughout the life span of 25 years of the
system, shall be submitted by the vendors. Hot
Dipped Galvanized steel coils. suitable arrangement
for base plate for foundation , solar panel mounting,
the structure should be suitable for carry the load of
solar panel,wiring, sprinkler system etc. with
necessary foundation work/wall mount, j bolt, anchor
fastner etc. the nut bolt used for installtion of
stucture should be (SS 304) quality.The ground
clearance of the bottom most edge of solar panel
shall not be less than 300 mm to 1200 mm or as per
(C ) Grid Tied Solar Power System: 11 - 25 kW (3 -
176 S.I.T.C of Poly Crystline/Mono Crystline PV Module 47 Per Watt 17,331.60
(ALMM approved) with 72 Cells - 150 Cells or More
Frame Material : Anodized Aluminum alloy Frame
With Twin Wall Profile, Front Cover : High
Transmission Low-Iron Tempered Glass (AR Coated),
High efficency and positive power tolerance Pmax:
0/+5, Module Efficiency should be approx. 18%-21%,
Normal operating temperature 45'C, Junction Box
with Waterproof IP67 & MC4 Compatible and
Enclosed with Bypass diodes 100%
Electroluminescence test to ensure error free
Modules, Thw temp. co-efficient of the PV module
shall equal or better than -0.45%/degree C. Solar PV
modules of minimum fill factor 75% to be used. Unit
Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg)
With 10 year Product warranty and 25 year Linear
Power Warranty.
(E) Moudule o/p Range: 520 - 545 watt, Maximum
Power Voltage Vmpp: 41 - 42 V, Maximum Power
Current Impp: 12.5 - 13 A
177 S.I.T.C of Solar Inverter Gried Tied: MPPT Range: 80- 25000 Per Watt 9.09
1000 V, Max efficiency: 97.5% - 98.9%, O/p
Frequency: 50/60Hz, Operating Altitude (m) ≤4000,
O/p Power Factor: ~1, O/P THDi: <3%, Operating
Tempreture Range: -25~60°C, Anti-islanding
Protection: Integrated, Input Reverse Polarity
Protection Integrated, Insulation Resistor Detection
Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection
Integrated, Output Short Circuit Protection
Integrated, Output Over Voltage Protection
Integrated, Protection Degree: IP65, User Interface
LCD & APP,Datalogger & Communication: GPRS / Wi-
(D) Solar Inverter: 15 kW to 25 kW: Max. input
Current: 27 A, Max DC i/p Power: 22100-32500W &
Nominal o/p Power: 15000-25000W, Nomimal O/p
Voltage: 400 V 3-Phase,Nominal O/p Current: 25-37A.
178 Supplying and Erecting Seamless Box Pipe of suitable 1500 Per kG 131.30
size for rooftop solar installations with good stability
agaist wind, Thickness 2 mm and 80 micron, Hot
Dipped Galvanized steel coils. suitable arrangement
for base plate for foundation , solar panel mounting,
the structure should be suitable for carry the load of
solar panel,wiring, sprinkler system etc. with
necessary foundation work/wall mount, j bolt, anchor
fastner etc. the nut bolt used for installtion of
stucture should be (SS 304) quality.
box. pipe ref. size (A) 40 x 40 x 2mm, (B) 50 × 50 ×
DC Cable: Electron beam cross linked compound,UV,
Ozone, Temperature & Hydrolysis resistant Flame
Retardant, Low Smoke Excellent Encapsulation
Very long / Service life >
Standards / Material Properties:
Fire performance : IEC 60332-1-2
Smoke emission : IEC 61034/ EN 50268-2
Halogen Free: EN 50267-2-1/-2, IEC 60754-2
Toxicity: EN 50305, ITC – Index <3
Ozone Resistant : EN50396
Weathering UV: HD 605/A1 or DIN
Approvals : EN 50618; H1Z2Z2-k
with suitable sized of PVC pipe(ISI Mark) and
Clamps,Shadels,Lugs.
178.1 (A) 1 core 4 sqmm copper DC cable Colour Red 250 RM 76.76
178.2 (B) 1 core 4 sqmm copper DC cable Colour Red 250 RM 76.76
180 S.I.T.C of Distribution board from AC Side ,ACDB 3- 1 Each 18,146.67
Phase - 21 kW - 50 kW: AC1 DUTY CONTRACTOR-80A
100A MCCB 4P(Cat III), 3 PHASE SPD, VOLTAGE
MONITORING RELAY,
ELR WITH CBCT, PHASE INDICATING LAMP, POWER
OTHER ACCESSORIES, All switchgears and connection
are enclosed with IP66 Enclosure and operate the
S.I.T.C of Distributiob System DC Side, DCDB - 20 kW -
25 kW (5in:5out) : Input Mcb - 1000 V, 16 Amp,
1000 V DC SPD TYPE 2, TERMINAL/END,PLATE/END
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
182 Supplying & Errecting MC4 Connector Male - Female 47 Each 52.52
Set for Solar DC Cable which is installed in Solar PV-
module/Inverter/DCDB etc.
183 Supplying and erecting, commissioning and testing of 1 Each 6,75,844.53
Diesel Generating set confirming to IS: 4722:1968 &
BS:5514 having continuous rating, 3 phase, 415 volts,
50 cycles A.C. supply comprising of a totally enclosed
air/water cooled diesel engine with multi-cylinders
developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for one
hour in 24 hours with standard accessories like fly
wheel, lubricating oil cooler, "A" class governor,
heavy duty fuel wheel and lubricating oil filter, oil
bath air filler, lubricating oil pressure gauge, end
exhaust manifold, standard set of tools with
adjustable spanners, screw drivers, cylinder head to
cover, joint cylinder head to exhaust, element lube oil
filter, 12 / 24 volts electric starting equipment
complete with standard heavy duty battery, dynamo,
cut-outs, ammeter, necessary wiring, pressure gauge,
starter etc and heavy duty Residential type exhaust
silencer (With DEF System) and vertical hot air duct
logged with asbestos rope, save oil trays, exhaust
piping of required length, standard wall/floor
mounted fuel with level indicator and piping and drip
proof alternator, self excited, self regulated, screen
protected, with excitation system, capable of
delivering the rated system output at 415 volts,
phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM,
conforming to IS-4722- 1968 with voltage regulation
+/- 5% of rated voltage from no load to full load. Both
the engine and alternator fitted on a common
fabricated steel base plate with antivibration
mounting engine and alternator both connected to
each other by flexible flange coupling and with
floor/wall mounted control panel box comprising of
voltmeter ammeter, selector switches, ACB / MCCB
/ MCB of adequate capacity,
indicator lamps duly wired with HRC fuses. The
alternator & control panel shall be connected with
provided suitable capacity armoured cable and
complete with Acoustic enclosure (canopy) made out
of 16 SWG CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick conforming
to IS:8183 / PU Foam of 40 Density - at least 40 mm.
The resin bonded rockwool covered from inside the
canopy by perforated sheet with 3/4 mm holes,
sound level not more than 75 dB at a distance of
mtr, as per PVCT norms.DG set should have in built
fuel tank capacity of minimum 8 hrs of continous
running capacity on full load . Erection,
commissioning and satisfactory testing as per
requirement with first filling of fuel (minimum up to
the 80% of fuel tank capacity), oil, etc. with
guarantee / Warrantee of complete system for Two
years. & with obtaining all necessary certificate from
Electrical Inspector. The Capacity and Ratings of DG
sets are as below. (As per new CPCB4+ Emission
norms Engine With - Turbo Charger, EGR (Exhaust
Gas Recirculation), CRS (Common Rail Fuel System),
DOC (Diesel Oxidation Catalyst), SCR (Selective
Catalytic Reduction), Integrated wiring harness
connected to ECU .)
(I) Continuous Rating of 62.5 KVA ,BHP not less than
184 Providing & erecting approved make AMF control 1 Each 97,320.57
panel suitable for following size of 3 phase, 415 V.,
50 cycles, A.C. diesel generating set complete of
scope as detailed below:
1) Power module: A pair of electromechanically
interlocked contactors (for mains & generator)
Overload relay for generator contactor Neutral
contactor for mains and generator Power socket for
2) Control and metering module: Line voltage
monitor. Generator voltage monitor Ammeter
items attempt start facility. Air circuit
breakers/MCB/MCCB of suitable rating for
auto/manual operation. Auto/manual switch.
Emergency stop push buttons. Manual start push
button. frequency meter. Engine hour meter. Two
earthing studs.
3) Protection module: The engine shutdown in the
unlikely event of Low lube oil pressure High cylinder
head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start .
Emergency stop battery charger.
The AMF Panel of following capacity
(A) AMF Control Panel for 50/62.5 KVA 3 phase DG
185 Providing & erecting approved make ATS panel 1 Each 57,347.80
suitable for following size of 3 phase, 415 V.,
cycles, A.C. diesel generating set complete of scope
as detailed below:
1) Power module: Motorised Changeover switch
with ATS controller, Auxiliary contactor with NO & NC
contacts with Automatic Battery Charger, indicating
lamps for Generator ON, Mains ON, Load and suitable
control terminals and power terminals with neutral
earthing studs.
(C) ATS Panel for 50 / 62.5 KVA 3 phase DG Set
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having
200-250 Micron galvanising, connection terminal dia
of 14 mm with constant ohmic value surrounded
by highly conductive compound with high charge
dissipation suitable for following type of applications
with chamber and heavy duty cover.(approved make
OEM has to submit test certificate including value of
earth resistane of installation.
[A] For electrical installation up to 440 V Length of
Back filling compound - 1 Nos. of Bag of 15 Kgs.
Providing & erecting, programming, testing of
chairman unit microphone with flexible stem of
mm in length and light ring built in loud speaker ,two
head phone socket ,attractive design ,priority button
for chairman microphone,built in volume control for
head phones,chime tone facility to precede chairman
priority calls,microphone on/off button,red indicates
for microphone is active,frequency response -400Hz
to 10kHz,nominal acoustic input -85 dB SPL
[[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
188 Providing & erecting, programming, testing of 19 Each 5,565.10
Delegate unit microphone with flexible stem of
mm in length and light ring built in loud speaker ,two
head phone socket ,attractive design ,built in volume
control for head phones,chime tone facility to
precede chairman priority calls,microphone on/off
button,red indicates for microphone is
active,frequency response -400Hz to 10kHz,nominal
acoustic input -85 dB SPL [[Approved by Competent
Authority i.e. not Below the rank of Executive
Supplying & erecting dual channel amplifier ,power
handling capacity of 180 watt ,four micro phone
inputs with independent level control ,built in FM
tuner,with preset memories,USB drive & SD card for
MP3 playback ,100v /telephone input with priority
and VOX,frequency response-80 Hz to 18k Hz Philips
/ /distortion less than 1% @ rated power up to
units [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
190 Supplying and erecting ceiling speaker with rated 4 Each 2,569.44
power of 30 watt/power tapping 30/15/7.5 watt
available,opening angle 180 degree H * 77 degree V
,sound pressure level 88 dB ,frequency response of
70Hz to 20KHz [[Approved by Competent Authority
i.e. not Below the rank of Executive Engineer ]
SITC of 3LCD Lamp based projector having wxga
(1280x800) or better resolution with minimum white
brightness of 3800 lumens and color brightness of
3800 lumens. The projector should have minimum
1HDMI,1VGA input. Having contrast ratio of 15000:1
or more. the projector should have auto vertical key
stone correction of +/- 30 degree and Manual
Horizontal of +/-30 degree. the projector should have
optical lens, throw ratio 1.30-1.56:1. Zoom Factor of
1.2. Lens focus Manual having focal length 16.9mm to
20.28mm. projector should have features like AV
mute slide, quick corner and split function and should
support wireless functionality with inbuilt wifi or wifi
dongle. [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
192 SITC of universal Projector mounting kit, with 1 Each 6,848.81
necessary grouting, fasteners etc. with adjustable
height and suitable for all types of projectors.
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
193 SITC of 120 inch Self Lock MW (8 x 6) Instalock Slow 1 Each 5,334.82
Retraction Screen, Aspect Ratio-4:3 [Approved by
Competent Authority i.e. not Below the rank of
Executive Engineer ]
194 SITC of O. F.Cable 06F Outdoor - Armoured Unitube 20 Each 50.50
SM - HDPE Sheath [Approved by Competent
Authority i.e. not Below the rank of Executive
195 SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM 1 Each 6,901.33
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
196 SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m 20 Each 779.72
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
197 SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m 20 Each 1,901.83
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
198 SITC of CAT6 UTP 23AWG Solid: Per Meter [Approved 20 Each 43.43
by Competent Authority i.e. not Below the rank of
Executive Engineer ]
199 SITC of Face Plate - Single (Keystone Jack,square) 10 Each 90.90
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
200 SITC of Face Plate - Dual (Keystone Jack,square) 10 Each 101.00
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
201 SITC of Jack Cat 6 Keystone UTP [Approved by 20 Each 161.60
Competent Authority i.e. not Below the rank of
Executive Engineer ]
202 SITC of Patch Panel UTP Keystone- 24 Port- Unloaded 1 Each 1,499.85
(Cat 5e,Cat 6 & Cat 6 A ) [Approved by Competent
Authority i.e. not Below the rank of Executive
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-
Fully Loaded [Approved by Competent Authority i.e.
not Below the rank of Executive Engineer ]
204 SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' 20 Each 156.55
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
205 SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' 20 Each 200.99
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
SITC of 8 x 10/100/1000BASE-T PoE ports 2 x Gigabit
Advanced L2 switching and security features L2+
Static Routing Optional “standard mode” or
“surveillance mode” management user interface 65W
PoE budget [Approved by Competent Authority i.e.
not Below the rank of Executive Engineer ]
207 SITC of 24 x 10/100/1000BASE-T ports 4 x Gigabit 1 Each 15,399.47
RJ45/SFP Combo ports
Advanced L2 switching and security features L2+
Static Routing Optional “standard mode” or
“surveillance mode” management user interface
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
208 SITC of 24 x 10/100/1000BASE-T PoE ports 4 x Gigabit 1 Each 31,996.80
RJ45/SFP Combo ports Advanced L2 switching and
security features L2+ Static Routing
Optional “standard mode” or “surveillance mode”
management user interface 193 W PoE budget
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
209 SITC of 48 x 10/100/1000BASE-T ports 4 x Gigabit 1 Each 30,398.98
GbE/SFP combo ports
Advanced L2 switching and security features L2+
Optional “standard mode” or “surveillance mode”
management user interface
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
210 SITC of Maximum distance of up to 10 km Hot- 2 Each 4,801.54
pluggable Single-mode fiber 1000BASE-LX (IEEE
802.3z standard) Duplex LC connector MSA, RoHS-
compliant [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
211 Supply, Installation Testing & Commissioning 5 Mtr. 2 Each 828.20
HDMI Interface Cable as per the detailed
Specifications supports transmission of 4K Signals as
per the detailed Specifications
212 Supply, Installation Testing & Commissioning 10 Mtr. 2 Each 1,323.10
HDMI Interface Cable as per the detailed
Specifications supports transmission of 4K Signals as
per the detailed Specifications
213 Supply, Installation Testing & Commissioning 15 Mtr. 2 Each 1,777.60
HDMI Interface Cable as per the detailed
Specifications supports transmission of 4K Signals as
per the detailed Specifications
214 Supply, Installation, Testing and Comissioning of USB 1 Each 16,688.23
Full HD 1080p @ 30fps Webcamera, 1/3 " 2mp
Sensor, 90 degree Wide FOV, built in Mic, MJPEG
compression format, Manual Focus, Auto white
balance & other image processing algorithms, USB
2.0, BIS, CE,FCC, RoHS certified.
[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
215 Supply, installation, testing and commissioning of FM 1 Each 62,493.75
approved or UL listed microprocessor- based single
loop, true peer-to-peer networkable, addressable Fire
Alarm Control Panel (FACP) with its own
microcontroller memory, communication module,
fire device loop interface cards for intelligent
initiating and indicating devices and peer-to-peer
networkable with other addressable fire alarm
panels. conforming to UL 2572 mass notification
systems & NFPA 72, complete with accessories all as
specified and directed by engineer-in-charge. (one for
216 Supply, installation, testing and commissioning of FM 1 Each 3,471.88
approved or UL listed addressable control module to
provide FACP a circuit for notification appliances (e.g.
Horns, Strobes, Horn Strobes, etc.) having built-in
type identification, integral LED indicators, high noise
immunity, SMES screws with clamping plates for
wiring ease, direct-dial entry of address, etc.
complete with accessories as specified and directed
by engineer-in-charge.
217 Supply, installation, testing and commissioning of FM 2 Each 3,055.25
approved or UL listed surface / semi- flush mounted
Dual Action Manual Pull Station "Push In & Pull
Down" including an addressable interface for the
intelligent FACP having built-in bicolour LED which is
visible, flashing in normal operation and latching
steady red in alarm condition, captive screw
terminals wire-ready for easy connection to SLC loop
complete all as specified and directed by engineer-in-
218 Supply, installation, testing and commissioning of UL 2 Each 6,249.38
listed of Horn Strobe, wired as a primary notification
appliance, flashing 75 cd at 1 Hz over the strobe's
entire operating voltage range, xenon flash tube and
associated lens / reflector system, built-in
synchronization feature keeping strobes in sync for
up to 30 minutes, horn producing audible
annunciation of 75 dBA at 3 m distance complete all
as specified and directed by engineer-in-charge.
219 Supply, installation, testing and commissioning of FM 1 Each 48,606.25
approved or UL listed remote power supply
conforming to UL 864 & 1481 and NFPA 72 with
integral battery charger capable of charging up to
Ah batteries to provide regulated and filtered 24 VDC
power to notification appliance circuits, having power-
supervision relay, fully regulated and filtered power
output, AC trouble report selectable for immediate 2-
hour delay, selectable earth fault detection, etc.
complete all as specified and directed by engineer-in-
220 M & L for low smoke zero halogen (LS0H) flame 30 Rm 111.10
retardant fire alarm cable, conforming to BS 7629-1,
BS 6387 & BS EN 50200 and rated for 500 V, having
plain annealed stranded copper conductor with
primary insulation of glass mica fire resistant tape
and secondary insulation of high performance
silicone rubber, earth/drain wire of annealed tinned
copper, electrostatic screen of aluminium fire barrier
and type LTS3 outer sheath conforming to BS
suitable for operating temperature range -30 ˚C to
+70 ˚C and minimum bending radius being 6 times
the overall cable diameter, RED in colour, including
laying, termination and ferruling complete all as
specified and directed by engineer-in-charge. 2 core,
221 Supply, installation, testing and commissioning of 1 Each 66,660.00
electric driven Booster Pump at the terrace tank level
to deliver 900 LPM flowrate at 30 MWC head and
suitable for automatic operation and consisting of
following, complete with accessories as specified and
directed by engineer-in-charge.
222 M & L for ISI marked MS ERW pipes conforming to IS: 20 RM 486.06
1239 (Part 1 & 2) with all accessories like all fittings
including tees, elbows, reducers, union, flanges,
rubber gaskets, GI nuts bolts, washer, including
supporting/fixing the pipe on floor / wall / ceiling
with clamps, hangers, angles, channels (using anchor
fasteners) with painting of one coat primer and 2 or
more coats of synthetic enamel paint complete as
specified and directed by the engineer-in-charge.
223 S & F PN 1.6 rated CI 100 mm NB sluice valve, 1 Each 9,026.88
conforming to IS 14846: 2000, having CI body, wedge,
bonnet, stuffing box, gland, handwheel, thrust plate,
GM body ring, wedge ring, wedge nut, CS bolts &
nuts, SS stem, flange drilling standard end connection
conforming to IS 1538: 1993, etc. along with
necessary accessories complete all as specified and
directed by the engineer-in-charge.
M & L for PN 1.6 rated 100 mm NB Cast iron (CI) non
return valve, conforming to IS 14846: 2000 with cast
iron body & bonnet, SS spindle & stem conforming to
IS 6603: 2001, cast iron stuffing box, carbon steel
stud / bolt / nut & washer, Hand wheel operated and
flange end connection conforming to IS 1538:
with necessary accessories complete all as specified
and directed by the engineer-in-charge.
S & F of PN 1.6 rated 25 mm NB full bore, two piece
design, quarter turn, lever operated brass ball valve
having nickel-plated forged brass body & end
connector, brass chrome plated ball, PTFE body seat
ring & packing, H.T. brass stem, nut & gland, rubber
'O' ring, powder coated MS lever and screwed female
ends, etc. with accessories complete as specified and
directed by the engineer-in-charge.
226 S & F indoor type lockable wall-mounted hose 2 Each 3,888.50
cabinet made of 18 gauge MS sheet of size 800 mm X
600 mm X 250 mm having double door with 3 mm
thick glass and door frame made of 16 gauge MS
sheet painted two coats of fire red outside and
brilliant white inside over a coat of primer suitable to
house two sets of hose RRL hose (15 m length) and
gunmetal branch pipe complete as specified and
directed by the engineer-in-charge.
S & F gunmetal fire hydrant single landing valve with
80 mm NB flanged inlet, brass spindle controlled
mm NB female instantaneous outlet type gunmetal
coupling, blank cap, chain, twist release type lug & all
accessories conforming to IS 5290: 1993 including
fixing and flanged tapping complete as specified and
directed by the engineer-in-charge.
228 S & F non-percolating rubber reinforced lined RRL 4 Each 5,832.75
hose type- A 15 m long fire hose of 63 mm NB size,
conforming to IS 636: 1988, rated for bursting
pressure of 35.7 kg/cm² complete with gunmetal
male & female coupling conforming to IS: 903-
bound and rivetted to the hose pipe with copper
rivets and 1.5 mm² copper wire complete as specified
and directed by the engineer-in-charge.
S & F branch pipe, conforming to IS 903: 1993, having
63 mm NB instantaneous gunmetal inlet, made
threaded outlet, 15 mm NB long nozzle, suitable for
inter connection to hose pipe coupling complete as
specified and directed by the engineer-in-charge.
230 S & F swinging type 36 m long First Aid Hose Reel, 2 Each 9,026.88
conforming to IS:884-1969, having 19 mm NB
thermoplastic reinforced hose reel tubing,
conforming to IS: 12585- 1988, 25 mm NB ball valve,
stop cock, terminating with gunmetal coupling &
nozzle of 6 mm NB outlet with shut-off valve,
conforming to IS: 8090- 1976 complete with MS
socket for tap-off, red colour drum, brackets
(including painting) for fixing on wall with anchor
fastener, bolts, nuts, etc. complete as specified and
directed by the engineer-in-charge.
231 Supplying, installing ,testing and commissioning of 1 Each 25,691.88
MS air cushion tank on top of each riser, conforming
to IS: 4736-1968, fabricated from 6 mm thick MS
plate, 200 mm in diameter and 1.2 m in height with
dished ends fabricated from 8 mm thick MS plate
having flanged inlet connection and drain
arrangement with 25 mm NB valve, pressure gauge &
gun metal stop cock complete as specified and
directed by the engineer-in-charge.
232 Supply, installation, testing and commissioning of 4- 1 Each 10,415.63
way fire brigade inlet connection, conforming to IS:
5290- 1993, with four 63 mm NB inbuilt gunmetal
non-return valves, four 63 mm NB instantaneous
couplings arranged on 150 mm NB pipe manifold and
connected to fire hydrant ring main and fire hydrant
wet riser pipe complete as specified and directed by
the engineer-in-charge.
233 Providing and erecting ISI mark Medium class RIGID 50 RM 33.33
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed (b) 25 mm
234 Supplying and erecting push button operated fully Each 1.00 9,758.62
automatic Star-Delta starter with 3 Nos. of 15A.rating
contactors and directly operated thermal overload
relay having 10-21A range and erected in sheet
steel enclosure for 3 phase 415V. 50 c/s. A.C. motors
from 7.5 to 15H.P. complete erected on
235 Providing and erecting XLPE (IS:7098)(I)-88 ISI 30 Mtr. 140.39
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (C)
236 Supplying & erecting carbon dioxide (CO2) fire 10 Each 8,671.86
extinguisher user of following capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete. [B] For 5.5 / 6.5 KG
237 Supplying & erecting ABC powder type 'Ceasefire' 10 Each 848.40
type Fire extinguisher as per IS 13849 or 1 Kg capacity
with necessary clamp for erection on wall
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and
words) of the estimated rate mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.:
PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C.
items where there is a change as per actual mix design the cost of difference of cement consumption
have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Dy. Executive Engineer Divisional Accountant
Irri. Project. Sub-Dn. No.17 Medium Irrigation Project Division
Ankleshwar Ankleshwar
Executive Engineer
Medium Irrigation Project Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. SBD INSPECTION BUNGALOW final.pdf
2. BOQ.pdf
3. General Specs.pdf
4. Electrical specs.pdf
5. TECH SPECS.pdf
6.1 All Dwgs.pdf
Download all tender documents and submit your bid