| Sl No | Description | Qty | Unit | General Engineering and Constructions L5 | AISWARYA ENTERPRISES L1 | AR Traders L3 | M/s.Rejoy Constructions L4 | Green Ray Enterprises L6 | S. M. Enterprises L2 | ELSOL ENGINEERS L7 | ELAN ENGINEERS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and Labour for monthly comprehensive maintenance , repair and servicing of 'Best Water Doctor' water cooler with normal, hot and cold water dispending system of 85/90/125 ltr capacity of make:- Cross field. Including covering all spares/parts if found un serviceable during the period. Replacement of activated carbon and other consumable once after every six month like air driver bottle, DS caddle. which ever be required to provide smooth function of the machine , all are specified and directed by Enginer-in- Charge.
Note :- (1) The comprehensive maintenance shall be done through OEM or authorised agency of OEM, MOU between OEM authorised agency and contractor to be submitted before commencement of work
(2) The parts shall be genuine and from original equipment manufacturer (OEM) and approved by GE. | 4,095 | Each Job | 950 ₹38.9 L | 875 ₹35.8 L | 920 ₹37.7 L | 960 ₹39.3 L | 895 ₹36.7 L | 919 ₹37.6 L | 965 ₹39.5 L | 1,100 ₹45.0 L |
| 1.01(3) The contractor is responsible to carried out services once in every quarter(3 months) through OEM during the contract period or as per users requirement to ensure the serviceability of the machine. (4) All body parts and other accessories shall be thoroughly cleaned to remove strains etc with suitable solution, during the service time. (5) Any break down / complaints shall be attend and with in the same day and rectification shall be intimated. (6) The rates quoted for above items shall be included for replacement of any spares becoming unserviceable during the period and no extra claim shall be allowed. (7) A penalty of Rs. 1000/- per day will be levied in case breakdown of machine more than 24 hrs from the time of complaint registration due to non attending. (8) The contractor has to submit no due cirtificate from the the OEM before claming RAR. (9) The contractor has to provide sufficient numbers of all the required spare parts during the contract peroid so that all the complaints to be rectified on the same day. | |||||||||||
| 2.00 | Material and labour for attending day to day complaints pertains to various water cooler of make Voltas/Usha/Blue Star and water filter of any make and capacity as and when required by Skilled Mechanic and helper with necessary tools and plants for checking the water cooler at existing location, find out the faults, complete and rectification of the defected water cooler and making it serviceable in all respect all as directed by the Engineer -In Charge.
Note:- Minor parts costing up to Rs 100 where required, deems to be inclusive of the rate quoted. Other major parts will be paid under relevent items. | 1,500 | Each Job | 170 ₹2.5 L | 200 ₹3 L | 250 ₹3.8 L | 159 ₹2.4 L | 250 ₹3.8 L | 150 ₹2.3 L | 225 ₹3.4 L | 205 ₹3.1 L |
| 3.00 | Materal and labourfor General servicing of Water Cooler of capacity 40/40, 40/80 or 60/120 Litres after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any including refixing the Water Cooler in same/ other location and connecting, commissioning complete all as specified and directed. | 80 | Each Job | 380 ₹30,400 | 300 ₹24,000 | 300 ₹24,000 | 409 ₹32,720 | 450 ₹36,000 | 395 ₹31,600 | 325 ₹26,000 | 427 ₹34,160 |
| 4.00 | Materal and labourfor General servicing of Water Cooler of capacity 40/40, 40/80 or 60/120 Litres after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, leak testing at same location, replace the unserviceable parts if any including refixing the Water Cooler in same/ other location and connecting, commissioning complete all as specified and directed.
Note:- Charging of refrigerant gas will be measured and paid under relevant schedule item complete all as specified and directed | 300 | Each Job | 380 ₹1.1 L | 200 ₹60,000 | 150 ₹45,000 | 399 ₹1.2 L | 500 ₹1.5 L | 395 ₹1.2 L | 380 ₹1.1 L | 374 ₹1.1 L |
| 5.00 | Supply and fixin replacement, hermetically sealed compressor unit suitable for water cooler of capacity 40/40, 40/80 Litres capacity of the existing unserviceable sealed compressor unit including gas charging and connecting up complete all as specified and directed | 10 | Each Job | 4,800 ₹48,000 | 3,500 ₹35,000 | 5,500 ₹55,000 | 5,250 ₹52,500 | 4,800 ₹48,000 | 5,000 ₹50,000 | 4,200 ₹42,000 | 6,000 ₹60,000 |
| 6.00 | All as per item No 5 here in above but suitable for Water Cooler of capacity 60/120 Litres complete all as specified and directed. | 5 | Each Job | 6,200 ₹31,000 | 4,200 ₹21,000 | 6,000 ₹30,000 | 5,000 ₹25,000 | 5,200 ₹26,000 | 5,100 ₹25,500 | 4,500 ₹22,500 | 5,700 ₹28,500 |
| 7.00 | Supply and fix in repair fan motor 240 Volt with leaf suitable for water cooler of capacity 40/80/120 Litres complete all as specified and as directed. | 32 | Each | 2,100 ₹67,200 | 800 ₹25,600 | 800 ₹25,600 | 2,500 ₹80,000 | 2,250 ₹72,000 | 2,250 ₹72,000 | 2,000 ₹64,000 | 2,400 ₹76,800 |
| 8.00 | Supply and fix in repair PVC float valve assembly 15mm bore suitable for water cooler complete all as specified and as directed | 60 | Each | 250 ₹15,000 | 300 ₹18,000 | 300 ₹18,000 | 309 ₹18,540 | 400 ₹24,000 | 290 ₹17,400 | 325 ₹19,500 | 325 ₹19,500 |
| 9.00 | Supply and fix in repair 15 mm bore lift cock tap suitable for water cooler complete all as specified and as directed. | 90 | Each | 290 ₹26,100 | 450 ₹40,500 | 450 ₹40,500 | 229 ₹20,610 | 350 ₹31,500 | 225 ₹20,250 | 425 ₹38,250 | 275 ₹24,750 |
Tender Value
Refer Docs
EMD Value
₹92,020
Closing Date
16 Jun 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR/COMPREHENSIVE MAINT OF HOT AND COLD WATER COOLER WITH INBUILT WATER PURIFIER AND COLD WATER COOLERS AND CONNECTED WORKS AT VARIOUS LOCATIONS NAVAL BASE KOCHI
2025_MES_708815_1
8502/E8
Open Tender
Electrical and Maintenance Works
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹92,020
Yes
12 Feb 2026
17 May 2025
18 Jun 2025
17 May 2025
16 Jun 2025
2 Jun 2025
17 May 2025 - 18 May 2025
Amount
Material and Labour for monthly comprehensive maintenance , repair and servicing of 'Best Water Doctor' water cooler with normal, hot and cold water dispending system of 85/90/125 ltr capacity of make:- Cross field. Including covering all spares/parts if found un serviceable during the period. Replacement of activated carbon and other consumable once after every six month like air driver bottle, DS caddle. which ever be required to provide smooth function of the machine , all are specified and directed by Enginer-in- Charge. Note :- (1) The comprehensive maintenance shall be done through OEM or authorised agency of OEM, MOU between OEM authorised agency and contractor to be submitted before commencement of work (2) The parts shall be genuine and from original equipment manufacturer (OEM) and approved by GE.
(3) The contractor is responsible to carried out services once in every quarter(3 months) through OEM during the contract period or as per users requirement to ensure the serviceability of the machine. (4) All body parts and other accessories shall be thoroughly cleaned to remove strains etc with suitable solution, during the service time. (5) Any break down / complaints shall be attend and with in the same day and rectification shall be intimated. (6) The rates quoted for above items shall be included for replacement of any spares becoming unserviceable during the period and no extra claim shall be allowed. (7) A penalty of Rs. 1000/- per day will be levied in case breakdown of machine more than 24 hrs from the time of complaint registration due to non attending. (8) The contractor has to submit no due cirtificate from the the OEM before claming RAR. (9) The contractor has to provide sufficient numbers of all the required spare parts during the contract peroid so that all the complaints to be rectified on the same day.
Material and labour for attending day to day complaints pertains to various water cooler of make Voltas/Usha/Blue Star and water filter of any make and capacity as and when required by Skilled Mechanic and helper with necessary tools and plants for checking the water cooler at existing location, find out the faults, complete and rectification of the defected water cooler and making it serviceable in all respect all as directed by the Engineer -In Charge. Note:- Minor parts costing up to Rs 100 where required, deems to be inclusive of the rate quoted. Other major parts will be paid under relevent items.
Materal and labourfor General servicing of Water Cooler of capacity 40/40, 40/80 or 60/120 Litres after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any including refixing the Water Cooler in same/ other location and connecting, commissioning complete all as specified and directed.
Materal and labourfor General servicing of Water Cooler of capacity 40/40, 40/80 or 60/120 Litres after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, leak testing at same location, replace the unserviceable parts if any including refixing the Water Cooler in same/ other location and connecting, commissioning complete all as specified and directed. Note:- Charging of refrigerant gas will be measured and paid under relevant schedule item complete all as specified and directed
Supply and fixin replacement, hermetically sealed compressor unit suitable for water cooler of capacity 40/40, 40/80 Litres capacity of the existing unserviceable sealed compressor unit including gas charging and connecting up complete all as specified and directed
All as per item No 5 here in above but suitable for Water Cooler of capacity 60/120 Litres complete all as specified and directed.
Supply and fix in repair fan motor 240 Volt with leaf suitable for water cooler of capacity 40/80/120 Litres complete all as specified and as directed.
Supply and fix in repair PVC float valve assembly 15mm bore suitable for water cooler complete all as specified and as directed
Supply and fix in repair 15 mm bore lift cock tap suitable for water cooler complete all as specified and as directed.
Supply and fix in repair 15 mm PVC connection 1 meter long suitable for water cooler complete all as specified and as directed
Supply and fix in repair 1 1/4" flexible hose suitable for water cooler drain complete all as specified and as directed.
Materal and labourfor spray painting single coat anti corrosive enamel paint to water cooler of any capacity complete all as specified and as directed
Supply and fix in repair Solonoid valve suitable for water filter of any make and model all as specified and directed by Eing -in-Charge
Supply and fix in repair printed circuit board suitable for water filter of any make and model all as specified and directed by Eing -in-Charge
Supply and fix in repair UV lamp suitable for water filter of any make and model all as specified and directed by Eing -in-Charge
Supply and fix in repair flexible hose pipe along with connectorssuitable for water filter of any make and model all as specified and directed by Eing -in-Charge
Materal and labourfor repair of existing water cooler platform including Supply and fixof tiles, masonry brick work and proper sloping to ensure water flow to drain pipe with proper finish complete all as specified and as directed by Engineer in charge.
Material and Labour for servicing of UV water filter including changing of pre fileter and carbon fileter once in every six months. Note :- Rates quoted deems to be inclusive of carbon and pre filter complete all as specified and as directed .
Supply and fill refrigerent Gas R-22 complete all as specified and as directed .
Supply and fill refrigerent Gas R-134a complete all as specified and as directed .
Note :- 1. Complaints/service schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis. 2. A penalty of Rs. 1000/- per day will be levied in case breakdown of equipment is more than 24 working hours from the time of complaint registration due to non rectifing the defects
S. M. Enterprises (BID ID -3315691)
AR Traders (BID ID -3317476)
M/s.Rejoy Constructions (BID ID -3319837)
General Engineering and Constructions (BID ID -3317250)
Green Ray Enterprises (BID ID -3323213)
ELSOL ENGINEERS (BID ID -3316918)
ELAN ENGINEERS (BID ID -3317682)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf