TWO YEAR RATE CONTRACT FOR CHEMICAL CLEANING AND REPAIRS OF ATUS,HES AND COOLERS FITTED ONBOARD IN SHIPS
2019_NAVY_503444_1
DYT/SYS/19-20/106(A/PL-IN/ IN SHIPS-ATUS/HES/068
Open Tender
Miscellaneous Services
Item Rate
730 days
NAVAL DOCKYARD MUMBAI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2.2 L
Yes
NAVAL DOCKYARD MUMBAI
10 Jan 2020
17 Sept 2019
10 Oct 2019
17 Sept 2019
9 Oct 2019
28 Sept 2019
27 Sept 2019
Amount
Material Cost of - Insitu chemical cleaning of water side of HEs / ATUs/Coolers, renewal of trunking connect to both sides of HEs onboard IN Ships are as follows:- (a) De-lagging and re-lagging of ATUs/HEs/Coolers inlet / outlet pipeline of the chilled water system and dismantle the pipelines. (Removal will be done in the presence of Ship’s Staff after obtaining their necessary approval. Location of the defective HE’s will be indicated by ship staff). (b) Rig up pump motor / tank for circulation of fresh water. The procedure of chemical cleaning would be as follows:- (i) Circulate fresh water for the period of 30 minute.(ii) Circulate chemical INDROX 11 (Equivalent i.e. PROTOSOLVE 29 or ORION 31 ) for the period of 2 hours. (iii) Circulate the fresh water twice for the period of 10 minutes. (iv) Circulate caustic soda for the period of 30 minutes (v) Circulate fresh water thrice for the period of 10 min each. (c) Flush the system with water so as to remove all dirt. The firm is to certify that the system is free of chemicals. The unit reserves the right to test the flushed water for presence of residual chemicals. (d) De-lagging and re-lagging of HEs/ ATUs/ Coolers and requisite trunkings / piping to carryout water jet spray cleaing of air side (shell side). (e) Water jet spray cleaning of fins and outer surface of tubes by water jet (f) Pressure test the ATUs/HEs/Coolers for no leakage. (g) Process of Repair :Post cleaning/ pressure testing of air and water side, any damage observed on tubes are to be blanked or where ever possible renew/replace tubes and undertake brazing repair on tube stack/flanges/pipes of ATUs/HEs/Coolers as decided by contract executing agency i.e SMSYS. U tube bend repair header, straightening of fins, repair/manufacturing of flanges and renewal of zinc protector where ever applicable post clearance from user dept/QC dept. (h) Re-fitting of HEs/ATUs/Coolers with renewal of trunkings connect to both sides of HEs, renewal/repair of piping and prove the system for no leakages. Repair/ Renew/ Refit drain pipes (02 mtrs) for each HEs/ATUs as required and prove the system for no leakages. (j) Painting of the Shell side and HEs/ATUs/Coolers by heat resistant paint (aluminum paint).
Service Cost of - Insitu chemical cleaning of water side of HEs / ATUs/Coolers, renewal of trunking connect to both sides of HEs onboard IN Ships are as follows:- (a) De-lagging and re-lagging of ATUs/HEs/Coolers inlet / outlet pipeline of the chilled water system and dismantle the pipelines. (Removal will be done in the presence of Ship’s Staff after obtaining their necessary approval. Location of the defective HE’s will be indicated by ship staff). (b) Rig up pump motor / tank for circulation of fresh water. The procedure of chemical cleaning would be as follows:- (i) Circulate fresh water for the period of 30 minute.(ii) Circulate chemical INDROX 11 (Equivalent i.e. PROTOSOLVE 29 or ORION 31 ) for the period of 2 hours. (iii) Circulate the fresh water twice for the period of 10 minutes. (iv) Circulate caustic soda for the period of 30 minutes (v) Circulate fresh water thrice for the period of 10 min each. (c) Flush the system with water so as to remove all dirt. The firm is to certify that the system is free of chemicals. The unit reserves the right to test the flushed water for presence of residual chemicals. (d) De-lagging and re-lagging of HEs/ ATUs/ Coolers and requisite trunkings / piping to carryout water jet spray cleaing of air side (shell side). (e) Water jet spray cleaning of fins and outer surface of tubes by water jet (f) Pressure test the ATUs/HEs/Coolers for no leakage. (g) Process of Repair :Post cleaning/ pressure testing of air and water side, any damage observed on tubes are to be blanked or where ever possible renew/replace tubes and undertake brazing repair on tube stack/flanges/pipes of ATUs/HEs/Coolers as decided by contract executing agency i.e SMSYS. U tube bend repair header, straightening of fins, repair/manufacturing of flanges and renewal of zinc protector where ever applicable post clearance from user dept/QC dept. (h) Re-fitting of HEs/ATUs/Coolers with renewal of trunkings connect to both sides of HEs, renewal/repair of piping and prove the system for no leakages. Repair/ Renew/ Refit drain pipes (02 mtrs) for each HEs/ATUs as required and prove the system for no leakages. (j) Painting of the Shell side and HEs/ATUs/Coolers by heat resistant paint (aluminum paint).
Material Cost of - Chemical cleaning and Repair of HEs/ ATUs and Coolers in firm’s work shop. Degutting/Regutting, De-lagging and re-lagging of ATU/HEs/Coolers, inlet / outlet pipeline and requisite trunkings/ piping of ATU/HE/Coolers. Removal and Shifting to firm’s workshop. (Removal will be done in the presence of Ship’s Staff after obtaining their necessary approval. Location of the defective HE’s/ATUs/Coolers will be indicated by Systems reps/Ship’s Staff). (a) The procedure of chemical cleaning would be as follows:- (i) Manual cleaning of ATUs/HEs/Coolers (ii) Water jet washing of ATUs & HEs /Coolers (iii) Prepare emulsion of chemical as per the manufacturer’s manual. (iv) Dip in chemical INDROX 11 (Equivalent i.e. PROTOSOLVE 29 or ORION 31) for the period of 4 hours/ as per the condition of ATUs/HEs/Coolers. (b) Removal of ATUs/ HEs/Coolers from the chemical tank and dipping in caustic soda tank for the period of 1.5 hr. (c) Removal of ATUs/ HEs/Coolers from the caustic soda and dip in fresh water tank (d) Flushing of ATUs/HEs/Coolers by water jet so as to remove all dirt/residual chemicals. The firm is to certify that the system is free of chemicals. The unit reserves the right to test the flushed water for presence of residual chemicals. (e) Pressure test the ATUs/HEs/Coolers for no leakage. Post cleaning/ pressure testing of air and water side, any damage observed are to be repaired by brazing /welding / plugging post clearance from user dept and QC dept. (f) Painting of the shell side plated by heat resistant paint (aluminum paint). (g) Fitment of ATUs/HEs/Coolers in their location by using original material gasket and fastener of standard make on board and prove the system for no leakages. If trials are found satisfactory, connect up/ replace all fittings removed earlier. (h) Repair/Renew/Refit drain pipes as required and prove the system for no leakages.
Service Cost of - Chemical cleaning and Repair of HEs/ ATUs and Coolers in firm’s work shop. Degutting/Regutting, De-lagging and re-lagging of ATU/HEs/Coolers, inlet / outlet pipeline and requisite trunkings/ piping of ATU/HE/Coolers. Removal and Shifting to firm’s workshop. (Removal will be done in the presence of Ship’s Staff after obtaining their necessary approval. Location of the defective HE’s/ATUs/Coolers will be indicated by Systems reps/Ship’s Staff). (a) The procedure of chemical cleaning would be as follows:- (i) Manual cleaning of ATUs/HEs/Coolers (ii) Water jet washing of ATUs & HEs /Coolers (iii) Prepare emulsion of chemical as per the manufacturer’s manual. (iv) Dip in chemical INDROX 11 (Equivalent i.e. PROTOSOLVE 29 or ORION 31) for the period of 4 hours/ as per the condition of ATUs/HEs/Coolers. (b) Removal of ATUs/ HEs/Coolers from the chemical tank and dipping in caustic soda tank for the period of 1.5 hr. (c) Removal of ATUs/ HEs/Coolers from the caustic soda and dip in fresh water tank (d) Flushing of ATUs/HEs/Coolers by water jet so as to remove all dirt/residual chemicals. The firm is to certify that the system is free of chemicals. The unit reserves the right to test the flushed water for presence of residual chemicals. (e) Pressure test the ATUs/HEs/Coolers for no leakage. Post cleaning/ pressure testing of air and water side, any damage observed are to be repaired by brazing /welding / plugging post clearance from user dept and QC dept. (f) Painting of the shell side plated by heat resistant paint (aluminum paint). (g) Fitment of ATUs/HEs/Coolers in their location by using original material gasket and fastener of standard make on board and prove the system for no leakages. If trials are found satisfactory, connect up/ replace all fittings removed earlier. (h) Repair/Renew/Refit drain pipes as required and prove the system for no leakages.
Material Cost of - Removal & Refitment of HEs/ ATUs /Coolers from ship to C-38/Systems department in the yard & back. Degutting/ regutting of all Naval Vessels ATUs/HEs/coolers & requisite gaskets for fitment of ATUs/HEs/Coolers which may include de-lagging/re-lagging, hot work for removal of ATU/HE/Coolers tallying and transportation to work centre (C.No.38)of MSYS, ND (MBi) and reinstallation of ATU/HE/coolers back in the system and proving of the system. Cost to include requisite gaskets. Defective fasteners to be replaced as per Naval Engg Standards for fitment of ATUs/HEs/Coolers
Service Cost of - Removal & Refitment of HEs/ ATUs /Coolers from ship to C-38/Systems department in the yard & back. Degutting/ regutting of all Naval Vessels ATUs/HEs/coolers & requisite gaskets for fitment of ATUs/HEs/Coolers which may include de-lagging/re-lagging, hot work for removal of ATU/HE/Coolers tallying and transportation to work centre (C.No.38)of MSYS, ND (MBi) and reinstallation of ATU/HE/coolers back in the system and proving of the system. Cost to include requisite gaskets. Defective fasteners to be replaced as per Naval Engg Standards for fitment of ATUs/HEs/Coolers
Powermech Services Private Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .