Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.9 L+₹85,461 (4.74%)Rejected-Finance 451 NEAR RADHA KRISHAN MANDIR VPO MAMUN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹19.1 L+₹1.1 L (6.08%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹23.1 L+₹5.1 L (28.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹19.8 L
EMD Value
₹39,600
Closing Date
5 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
REPAIR REPLACEMENT IMPROVEMENT TO LT NETWORK AND ALLIED CONNECTED WORKS AT MIL STN SAMBA
2022_MES_543500_1
GE/SMB/T-29/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Samba
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹39,600
Yes
3 Nov 2022
8 Aug 2022
7 Sept 2022
8 Aug 2022
5 Sept 2022
23 Aug 2022
8 Aug 2022 - 11 Aug 2022
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables, poles & stay or other items and getting out soil in any type soil complete all as specifed.
Excavation in trenches not exceeding 1.5 mtr wide and exc. 1.5 m but not exceeding 3.0 mtr in depth for poles or other items and getting out soil in any type soil complete all as specifed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified
Sand cushioning to under ground electric cable a layer of 8 cm thick before laying the cable and stretching the cable and punned down to form a bed of 18 cm and second layer of 15 cm thick after laying the cable complete all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be of good quality as specifed and punned thickness shall be measured and paid.
Well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including use of necessary form works for rough finished surface complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping to poles including use of necessary form works for rough finished surface complete all as specified and directed.
Supply & errection steel tubular swaged poles type 410 SP-31 (9 meter long) with 300mmx300mmx6mm MS base plate continuously welded to pole, finial taper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30 cm high with super enamel paint (black and white/yellow) from ground level/coping upto 1.5 m painting with two coats of aluminium paint for the remaining height complete all as specified and as directed. (Note : Excavation & earth work, GI Pipe shall be measured and paid for separately under respective items of BOQ).
Cross arms bracing supports clamps, back plates fabricated from steel section including nuts, bolts and washers welding, drilling hole, complete with two coats of aluminium paint over one coat of primer, complete all as specified and directed.
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 70 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 50 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 35 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 25 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 16 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 16 sqmm, 2.0 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 10 sqmm, 2.0 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
GI pipe in replacement ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including suitable size clamps complete of size 40 mm bore , complete all as specified and directed
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick not less than 6.0 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, connected to galvanised steel strip 32x6 mm by means of nuts, bolts, washers, check nuts of GI steel all as shown in electric plate no. 3 all as specified and indicated complete and including charcoal dust and salt etc and GI protection pipe, medium grade 40mm and GI watering pipe 20mm, medium grade with funnel and wire mesh, 15 mm thick Pre-cast RCC M-15 (Nominal mix) cover reinforced with XPM weight not less than 4 kg/sqm with suitable handle of 6 mm dia MS bar and angle iron 40x40x3 mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil, returning, filling in and removal of surplus soil and connected work, complete all as specified and directed.
Cutting, trimming of hanging/ extended branches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinity & around poles /conductor & will be measured as one span. Necessary prior permission shall be obtained from concerned AGE/ JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility.
Restringing/ restretching aluminium conductor on existing over head lines including necessary binding with binding wire with insulator , connections of incoming and out going cables at various areas under, complete all as specified and directed.
Taking down existing unserviceable /retrived old ACSR conductor from over head lines, complete all as specified and directed.
Aluminum conductor steel reinforced (ACSR) for LT lines on steel tubular poles/PCC poles, streching without kinks and bends including aluminum binding wires of suitable size of conductor as per load, complete all as spd and directed .
Taking down unserviceable/dismantling insulators any type and size complete all as specified and directed.
Replacement shackle type, procelain, vitreous, white, brown or green insulator including one galvanised iron steel straps, washer and insulator bolt dia 12 mm , washers, nuts one galvanised iron nut 75 mm height, 90 mm dia for 1100 volts grade including dismantling old unserviceable insulator, complete all as specified and directed.
Stay assembly complete with accessories as shown in electrical plate No. 1 of 16 mm dia complete all as specified and directed.
Replacement loop type insulator, vitreous porcelain, white brown or green with overall dimensions 65x90 mm clearance of hole 16 mm including dismantling old unserviceable insulator, complete all as specified and directed.
Galvanized stranded stay wire of size 7/4.00 mm including necessary binding with insulator, clamp and stay clamp, complete all as specified and directed.
Junction box suitable for LT PCC/Steel poles for street light 3 phase, 415 volts made out of 3.15 mm thick CRCA sheet with front openable doors including 04 nos aluminium busbar of 63 Amps current carrying capacity and one MCB SP 6 Amp mounted on din rail insulator, complete all as specified and directed.
Replacement of LT busbar chamber box of minimum size 90 cm (height) x 70 cm (width) x 45 cm (depth), outdoor type double door type, front / rear opening type suitable for 415 volts, 3 phase, 4 wire (100% neutral), 50Hz supply system, Box made out of 3.15mm (outer) & 2mm (inner compartment door) CRCA sheet factory made weather proof, dust proof and vermin proof duly powder coated with 04 nos , Make- Hindalco, aluminium busbar 300 Amps, 50 cm each (each busbar having 04 nos of nuts, bolts, washers) horizontally place in insulator suitable for lackable door arrangment complete with inter connections with aluminium solid strips, busbar chamber having 4 nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC of ratio 1:2:4 and 30 cm clear space from, complete all as specified and directed. Note : Panel shall be of front / rear opening with cable entry from the bottom.
Painting of LT Steel pole of any size including cross arms and street light bracket ligt upto 1.5 metre height from bottom with two coat of synthetic aluminium enamel paint including 5 Nos 30cm wide strip of black and yellow paint with two coats of synthetic enamel paint alongwith writing word "LT", and pole No complete all as specified and directed by the Engineer in charge. (Note- T&P & ladder for painting will be deemed included in quoted rate)
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
RD Engineers
dinesh enterprises
Bharat Builder
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .