| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.9 L+₹4.1 L (15.5%)Rejected-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹33.0 L+₹6.3 L (23.5%)Rejected-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹33.7 L+₹6.9 L (26.0%)Rejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹34.9 L+₹8.2 L (30.6%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-AOC Not lowest |
Tender Value
₹35.8 L
EMD Value
₹71,600
Closing Date
14 Mar 2020, 6:00 pmClosed
CWE Ambala
Headquarter Commander Works Engineer Ambala Mansfield Road Ambala Cantt
Special repairs to main distribution box DB and connected items of JCOs ORs Married accommodation of CW ASC AND harding lines under GE NORTH Ambala Cantt
2020_MES_317346_2
CWE/AMB/NORTH/T-49 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AMBALA CANTT
All as per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AMBALA CANTT
₹71,600
Yes
30 Mar 2020
25 Feb 2020
16 Mar 2020
25 Feb 2020
14 Mar 2020
2 Mar 2020
26 Feb 2020 - 2 Mar 2020
Amount
Supply and laying of sub main wiring with two runs of 6 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS-H, 1100 Volts grade cable with one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS-H, 1100 volts grade cable as earth conductor, drawn through and including PVC concealed conduit, in ceiling or wall, heavy duty grade, ISI marked, not less than 25 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories and taking down and removing from site existing old unserviceable burnt sub main wiring of any size and in any condition complete all as specified and directed. Note: (i) All runs of cable and one run of conduit shall be measured and paid as one metre length of unit. (ii) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Make of wire:-Finolex/Polycab/Havells Make of PVC Conduit:-Finolex/Polycab/Kalinga Premium
Supply and fixing of MCB SP, 6 to 32 Amps, 240 volt, 10 KA, 'C' curve, ISI marked, including taking down and removing from site existing old unserviceable MCB of any capacity and condition complete all as specified and directed. Make:Siemens/Schenider Acti 9/Hager Navello Plus/Legrand DX3.
Supply and fixing of RCBO, 40 Amps, 2 Module, 300 ma (HI immunity) sensitivity, 230 volts, 50 Hz, ISI marked, including taking down and removing from site existing old unserviceable RCBO or any other items complete all as specified and directed. Make: Siemens/Schenider Acti9 /Hager Nevello Plus./Legrand DX3.
Supply and fixing in repair, low voltage and over voltage release, 230 V, single phase, in one module, suitable for single phjase and neutral complete all as specified and directed. Make: Legrand / Schneider Acti 9/Hager Cat Pt No MZ215
Supply and fixing of sheet metal MCB DBs, 8 way with 200 Amps rated bus bar, single pole and neutral, with acrylic double door, IP-43, fixed on wall, duly grouted in solid block wall or on wooden board with and including copper lugs/thimbles duly crimped for connection, including taking down and removing from site existing old unserviceable MCB DB complete all as specified and directed. Make: Siemens/Schenider Acti 9/ Hager Nevello Plus/Legerand DX3.
Supply and fixing of MCCB DB, vertical type, 4 way, double door, load line, powder coated complete alongwith 200 Amps rated bus bar, three pole and neutral, with acrylic door, fixed on wall duly grouted in solid block wall or on wooden board with and including copper lugs/thimbles duly crimped for connection, including taking down and removing from site old unserviceable DB complete all as specified and directed. MCCB, 63 Amps, 4 pole, thermal and magnetic release as incomer, by the Engineer-in-Charge. Make for DB/MCCB: Siemens Beta Guard/Schenider (Acti 9)/Hager Nevallo Plus./Legrand konex3
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty), 1100 Volts grade, with stranded aluminium conductor, of cross sectional area 25 Sq mm 3.5 core, suitable for 1100 Volts earthed system and laying in trenches/walls/ducts/passing through pipe etc.and testing after laying including disconnecting and taking down and removing from site existing old unserviceable cable complete all as specified and directed. Make Of Cable: Gloster/Finolex/Havells/Polycab
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil for laying of under ground cable/ erection of poles or stays etc. complete all as specified and as directed.
Returning filling in, in soil, including spreading leveling watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
Removing excavated spoil/materials to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 above the starting point complete all as specified and as directed.
Material and labour for fine and dry sand, cushioning for underground cable, by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including stretching the cable and punning sand cushioning complete all as specified and directed. Note - Punned thickness of sand layer shall only be measured and paid to contractor.
Supply and laying of un-reinforced, precast concrete cable cover, class LV, type 1, with peak, size 250 mm x150 mm x40 mm complete all as specified and as directed.
Supply and fixing light grade, GI tubing, of size 50mm dia, with all fittings and fixtures, for cable protection and fixed with clamp to pole and wall with nuts and bolts or laid in trenches/road crossing etc. including taking down and removing from site existing old unserviceable GI pipe of any description, dia and type complete all as specified and directed. Make: Tata/Jindal/Prakash
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc protected by GI pipe 15mm bore(medium grade) and connected to test point and earth dolly or to main switch board or main control board as directed and as specified and all shown in electrical plate No.3 of SSR Part-I 2009 including excavation and earth work in any type of soil, PCC (1:3:6) type C1 in chamber, pre cast RCC slab 400 x 400 x 50mm thick in cement concrete (1:2:4) type B1, reinforced with with 8mm dia TMT bars @ 15cm C/C both ways with one handle for lifting made out of 8mm dia bar with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, charcoal or coke and salt in alternate layers, lugs, test point etc and earth testing on completion complete all as specified and as directed.
Note:- Amount of credit of Rs. 2,12,812.00 for retrieved materials is mentioned in Schedule of Credit on Page No. 52 of tender documents in pdf form which will be deducted offline while acceptance of tender.
R N Enterprises
M/S Sonu Traders
Raman Electric Trading Co
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .