Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.4 L+₹44,086.55 (1.92%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹21.2 L
EMD Value
₹50,000
Closing Date
15 Mar 2024, 3:00 pmClosed
EXECUTIVE ENGINEER KWA WS DIVISION KANNUR
EXECUTIVE ENGINEER KWA WS DIVISION KANNUR
DEPOSIT-KRFB Dismantling and relaying of 700 mm DI pipe for gradient cutting work along Maruthayi Irikkur PWD road at various chainages KIIFB road work of PWD for a length of 260 mPipeline Work.
2024_KWA_668120_1
WRD/KWA-CE(NR)/TR/24681/2023_
Open Tender
Civil Works - Water Works
Item Rate
60 days
IRIKKUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
Yes
₹50,000
10 Jun 2024
7 Mar 2024
16 Mar 2024
7 Mar 2024
15 Mar 2024
7 Mar 2024
Amount
1 - Relaying 700 mm DI summer pumping line
OD289196/2023-2024:Conveying 700mm dia DI K9 pipes from Division store at Kannur to the work site including all cost of loading, unloading and carriage charges etc.complete
15.53.1:Dismantling of C. I sluice valve including stacking of useful materials within a lead of 50 metres.Upto 150 mm diameter
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
OD289197/2023-2024:Dismantling 700mm diameter Ductile Iron Class K-9 Pipes including specials (half the rate for laying).
OD289198/2023-2024:Dismantling push - on-joints to 700 mm dia pipes Centrifugally (Spun) Ductile Iron Pipes and specials
OD289199/2023-2024:Dismantling flanged joints to double flanged CI/DI pipes and specials for 700mm Diameter DI Pipe.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
100.14.11:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 700mm diameter Ductile Iron Class K-9 Pipes.
18.68.2:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Above 600 mm dia
18.69.2:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Above 600 mm dia
100.22.1:Labour for cutting C.I. pipe with steel saw: 700mm diameter C.I. pipe.
18.70.12:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:700 mm dia pipes
100.35.11:Testing 700mm DI/CI pipeline with potable water to the required test pressure. 700 mm dia Observed Data derived from item no.1030 of PHED DATA
100.41.40:Supply, stacking, spreading and consolidating of Red earth in the trench of pipe line for cushion including carriage, loading, unloading & stacking up to any lead.
100.19.1:Providing flanged joints to double flanged CI/DI pipes and specials, including testing of joints: 700mm Diameter Pipe.
100.32.6:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 150mm Double Acting Air Valve.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
OD289200/2023-2024:Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
SATHYANATHAN E
Bidder Name
SATHYANATHAN E
THEJAS E
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1038654.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .