Executive Engineer, panchayat, R & B Division, Surat.
Upgradation of Various Anganwadi in Palsana Taluka (1) Upgradation of Anganvadi building Vanesa-1 at village Vanesa (2) Upgradation of Anganvadi building Taraj-2 at village Taraj(3)Upgradation of Anganvadi building Dhamdod-2 at village Dhamdod(4)Upgradation of Anganvadi building at village Karan (5) Upgradation of Anganvadi building Tundi-1 at village Tundi-1 (6)Upgradation of Anganvadi building Tantithaiya-1 at village Tantithaiya (7)Upgradation of Anganvadi building Amalsadi-2 at village Amalsadi (8) Upgradation of Anganvadi building Chalthan-4 at village Chalthan Ta. Palsana Di. Surat (5TH TIME)
272375
29 OF 2025-26
Open
Civil Works - Others
Works
Surat
5 documents required · 5 mandatory
₹900
Yes
Executive Engineer, panchayat R & B Division, surat
₹13,500
Yes
3 Feb 2026
3 Feb 2026
3 Feb 2026
16 Feb 2026
3 Feb 2026
The materials shall be got tested at Government recognized Laboratory, (R&B) or field Labouratory of GERI (R&B) for which
estimate amount put to Tender shall be recovered from the contractor from the R.A. bills and final bills at the testing charg
to the GERI by the Governement. However, if the charges increase over 1% no excess recovery shall be made from the con
resolution of B & C Department dated 10th May 1985 Vide TNC/1085 (4)s.
SCHEDULE FOR TESTING OF MATERIALS
Sr. No. Brief Description of Materials to Qty. of Prescription of test which Frequency @ which test shall be
be tested Material shall be carried out carried out
1 Coarse Aggregate - Gradation test 1 to 100 Cum – 1 test
(Metal, Kapchi, Gravel etc.) - Impact Value 100 to 500 – 3 tests
- Flakiness Index 500 to 1500 – 5 tests
- Water absorption 1500 to 5000 – 7 tests
- Stripping Value
2 Sand - Gradation One test per 150 Cum or as per
- Fineness Modulus requirement of relevant
- Specific gravity
- Water absorption
- Silt – Content
3 Bricks - Dimension and tolerance 1 Test @ 50,000 Bricks
- Water absorption
- Compressive Strength
4 Cement - Consistency Up to 50 MT 1 Test
- Setting Time 50 – 100 MT 2 Test
- Compressive Strength 100 – 200 MT 3 Test
- Fineness 200 – 300 MT 4 Test
- Chemical analysis 300 – 500 MT 5 Test
- Soundness 500 – 800 MT 6 Test
800 – 1300 Mt 7 Test
and 8 test for larger
5 Steel - Tensile Strength One test/ 40 tonnes/ per each
6 C.C. Cube - Compressive Strength 1 to 5 Cum. 1 Test.
6 to 15 Cum. 2 Test.
16 to 20 Cum. 3 Test.
21 to 50 Cum. 4 Test
51 & Above Cum. 4 + 1 for each
additional 50Cum or part thereof
7 Water - - One Test for each source
The Contractor shall have to pay 1% of the estimate cost put to tender towards all testing of materials and the s
deducted from their bills for the works.The testing of various materials shall be carried out in GERI or Recognis
per rate and result received shall be binding to all i.e. the contractor and Government. Testing charges shall be
Government no refund be made not extra charges over 1% shall be recoverable from the contractor.
Signature of Contractor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
3.Cement Standards -11-05-17 GR 2 Side.pdf
4.Tender Negotiation.pdf
5.Laboratory GR.pdf
6.GST GR.pdf
7.Steel Lap.pdf
11. Other GR.pdf
8.Clause 47 48.pdf
14 Building Booklet civil.pdf
Cement consumption gr.pdf
GST GR 1.pdf
Inspection 1.pdf
Laboratory GR 1.pdf
Steel Lap 1.pdf
5.GR.pdf
4.0 tender booklet.pdf
GR.pdf
Final GR and Special Attention To Tender.pdf
GR For Building Work.pdf
Building Test schedule.pdf
Environment GR_11zon (1).pdf
06-GR.pdf
1.0 DTP -Repairing 8 Anganvadi.pdf
Building-Specification Book.pdf
Standard Clause SBD For Anganwadi Repairing.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .