Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC lowest Bid | |
| 2 | L2₹23.7 L+₹3.2 L (15.6%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹24.9 L+₹4.4 L (21.3%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L3 | Rejected-Finance HIGHER BID | |
| 4 | L4₹27.4 L+₹6.9 L (33.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER BID |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011 Rajasthan
REPAIR MAINT OF MISC E AND M ASSETS AT AF STN JODHPUR
2023_MES_599715_1
86027/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF JODHPUR
As Per NIT
8 documents required · 8 mandatory
₹500
GE AF JODHPUR
₹60,000
Yes
30 Jun 2023
31 May 2023
30 Jun 2023
31 May 2023
28 Jun 2023
14 Jun 2023
Amount
Supply and fixing in repair LED flood light 150 watt 230 V AC outdoor type made of pressure die cast aluminium housing , high power LEDs with potted drivers including fixing arrangement suitable size nuts and bolts ,including PCC foundation 600 x600x 600 mm complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair brass Nozzels 1/8 inch dia adjustable type for high pressure on fountain pipe line complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair LED Aviation light-twin 8/6 watt with polycarbonate diffuser & cast aluminium housing IP 65 complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair LED Aviation light-single 8/6 watt with polycarbonate diffuser & cast aluminium housing IP 65 complete all as specified and directed by Engineer-in-Charge
labour for disconnecting , takng out monoblock submersiable pump set , 3 ph,415 V, AC of capacity 10 HP for repair and refixing after repair complete all as specified and directed by Engineer-in-Charge. Note :- The spare parts shall be measured and paid saparately in respective items of schedule.
Supply and fix in repair impeller CI suitable for 10 H.P.
Supply and fix in repair MS shaft with key suitable for monoblock submersible pump 10 H.P.
supply and fix in repair Pump body with terminal plates for monoblock submersible pump 10 H.P.
Material and labour for rewinding of monoblock pump set 10 H.P.
labour for disconnecting , takng out monoblock submersiable pump set , 3 ph,415 V, AC of capacity 7.5 HP for repair and refixing after repair complete all as specified and directed by Engineer-in-Charge. Note :- The spare parts shall be measured and paid saparately in respective items of schedule.
Supply and fix in repair impeller CI suitable for 7.5 H.P.
Supply and fix in repair MS shaft with key suitable for monoblock submersible pump 7.5 H.P.
supply and fix in repair Pump body with terminal plates for monoblock submersible pump 7.5 H.P.
Material and labour for rewinding of monoblock pump set 7.5 H.P.
Supply,install,testing and commissioning in repair submersiable pump set , Single phase 240 V, AC of capacity 1.0 HP complete all as specified and directed by Engineer-in-Charge
Supply,install,testing and commissioning in repair LED Post Top gate light,25 W, weatherproof with aluminium housing, clear acrylic diffuser, aluminium pole-cap complete with all accessories, suitable for OD of 50 mm pipe including fixing arrangement such as pipe nuts and bolts complete all as specified and directed by Engineer-in-Charge
Supply,install,testing and commissioning in repair LED Bollard stainless steel,9 W/10 watt, weatherproof circular stainless bollard with acrylic diffuser complete with all accessories complete all as specified and directed by Engineer-in-Charge
Supply,install,testing and commissioning in repair LED fountain light, SS body (dia 5") 27 W,Red, Green blue complete all as specified and directed by Engineer-in-Charge
Supply,install,testing and commissioning in repair DOL starter, single phase for 1 HP complete all as specified and directed by Engineer-in-Charge
Supply,install,testing and commissioning in repair DOL submersible pummp controller(Standard)-3 phase for 10 HP complete all as specified and directed by Engineer-in-Charge
Earthing complete with copper plate electrode 60×60cm.× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip 20X3 mm by means of bolts, nuts, check nuts and ashers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge
Galvanised iron strip 32 x 6mm buried in ground complete all as specified and directed by Engineer-in-Charge
Material and labour in repair Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32X6mm as earth lead dia by means of bolts, nuts, check nuts and ashers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge
Supply,fix and testing in repairs 3 core multistranded copper flat cables for submersible pump motor of size 6 Sqmm complete all as specified and directed by Engineer-in-Charge
S & F LT feeder pillar (kiosk) of suitable made out of 3 mm thick CRCA sheet duly powder coated outdoor type double door with openable front door including locking arrangement with AL busbar 4P , 200 Amps rating with MCCB 63 Amps 4 pole 16 KA thermal magnetic adjustable type for incoming and space for fixing star delta starter fixed on angle iron frame and PCC plinth complete as directed.
S & F LT feeder pillar (kiosk) of suitable made out of 3 mm thick CRCA sheet duly powder coated outdoor type double door with openable front door including locking arrangement with AL busbar 2P 200 Amps rating with MCB 63 Amps 2pole for incoming and space for fixing DOL starter fixed on angle iron frame and PCC plinth complete as directed.
Material & labour in replacement for sub main wiring with multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia)along with fittings and accessories all on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor complete including taking down existing sub main wiring all as specified and directed by Engineer in charge. (2 runs of main cable one run of earth wire one run of PVC pipe will be measured as an one run) (a) 2 Run of 4.0 Sqmm cable and one run of 4.0 sqmm cable for earth wire.
Supply and fix in repair central nozzel mashroom up to one inch dia for high pressure on fountain pipe line complete all as specified and directed by Engineer-in-Charge
Supply fix in replacement Facade light I/PV 88-264 Volt , PF not less than 0.95 RGBWW 40/36 Watt watt LED type made up of die cast aluminium housing with driver with control protocol DMX512 ,colour RGBWW,protection type constant current limiting, recovers automatically aftewr fault condition is removed that shut down O/P voltage , repower ON to recover including PCC for fixing light with suitable fixing arrangement.
Supply fix in replacement LED street light celesta antiquely designed aesthetically appealing landscape cum street light, made from aluminium housing, clear polymer diffuser to provide uniform and pleasant light output IP 65, 60 W all as specified and directed by Engineer-in-Charge
Supply fix in replacement pole for LED street light celesta antiquely designed aesthetically appealing landscape cum street light, made from aluminium housing, clear polymer diffuser to provide uniform and pleasant light output IP 65, 60 W all as specified and directed by Engineer-in-Charge
Excavating in trenches,in soft/loose soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material & labour for Tibba sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Material & labour for stone slab 40mm to 50mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50cms in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
Material & labour for PCC concrete block masonry with block, exc 10 cm in width and setting in mortar type B1, 1:2:4 ( 20 mm graded stone aggregate) complete all as specified and directed by the Engineer-in-Charge.
Shri Electrical Enterprises
Nvimal Engineers and Contractor
Siddharth Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .