| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹18,400
Closing Date
1 Sept 2021, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEEANDMWSCN
EEEANDMWSCN NEAR KANHIYA NAGAR METRO STATION DELHI-35
Electrification/Renovation of ZRO office (Central)-I , B Building Varunalaya Ph-I and other allied work at Varuanalaya HQ
2021_DJB_207620_8
NIT NO. 09 (2021-2022)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹18,400
Yes
7 Sept 2021
26 Aug 2021
1 Sept 2021
26 Aug 2021
1 Sept 2021
26 Aug 2021
120 days
Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (DSR No. 1.10.3 Group C)
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 in 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR No. 1.32)
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR No. 1.31)
Supply and fixing two module stepped type eletronic fan regulator on the existing modular plate switch box including connecctions but excluding modular plate etc. ass required. (DSR No. 1.25)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x1.5 sq. mm +1x1.5 sq. mm earth wire. ( DSR No. 1.14.1)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( DSR No. 1.14.2)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x4 sq. mm +1x4 sq. mm earth wire .(DSR No.1.14.3)
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. (DSR No. 1.14.10)
Supply and fixing 6 way(4+18), Double door, horizontal type three pole and nutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnetions , powder painted including earthing etc. as required. (DSR No. 2.4.2)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole -(DSR No. 2.10.1)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N - (DSR No. 2.1.2)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required 200 A TP&N - (DSR No. 2.1.6)
Installation , testing and commissioning of pre-wired, florescent fitting/ compact florescent fitting of all types, complete with all accessories and tube/ lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (DSR No. 1.41)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required (DSR No. 1.44)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (DSR No. 1.50.1)
Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required.(DSR No.1.38)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp.). (DSR No. 7.7.2)
Supply of Ceiling fan high speed 240 volt 1200mm sweep size (Market rate)make:- Orient/Havells/Cromton
Supply of heavy duty exhaust fan 300mm sweep size, 1400rpm make-Orient/Havells/Cromton
Supply of LED Batten 36-40 Watt. Make: Crompton/Havells/Orient.
Supply of LED Recessed 2x2 Tiles,Slim, Glare free uniform illumination, 36-42 watt. Make- Crompton/Havells/orient
Supply of C series MCB 63 Amp. TPN 10KA, C- curve 240/415 V, 50Hz. (make- Havells/C&S/L&T).
Supply of 16 sq. mm 4 core Aluminium Armoured wire make-Havells/Ploycab/RR Kabel
Providing of 1.5 ton 5 star rating inverter split air conditioner, make- Lloyd/Panasonic/Hitachi
Providing of 1.5 ton 5 star rating window air conditioner, make- Lloyd/Panasonic/Hitachi
Providing of voltage stabilizer suitable for 1.5 ton air conditioner. Make:-V-Guard/Microtek.
Providing of heavy duty Iron stand for split air conditioner.
Installation charges of split AC
Installation charges of window AC
Dismantling charge of Split AC
Dismantling charge of window AC
HARI ELECTRICAL CO.
HYDROCON ENGINEERS
Cantilever Engineers
A.V ENGINEERING
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .