Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹22.7 L+₹1.5 L (7.09%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹24.8 L+₹3.6 L (17.1%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DC Sharma IDSE CWE (NW) KOCHI
CWE (NW) KOCHI
REPAIR/PREVENTIVE MAINT OF SCREW CHILLAR 3x120 TR CAPACITY, 240 TR COOLING LOWER INSTALLED IN NAY (K) AND CONNECTED ITEMS AT NAVAL BASE KOCHI
2022_MES_561360_1
CWE (NW) KOCHI/81314
Open Tender
Civil Works
Item Rate
330 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (NS) KOCHI
₹50,000
Yes
29 Dec 2022
4 Nov 2022
5 Dec 2022
4 Nov 2022
2 Dec 2022
18 Nov 2022
Amount
Preventive maintenance and check up of Dunhambush chiller unit complete accessories,controlls comprising of rotory screw compressors with standared fittings electric motor with double delta starter of suitable capacity for rotory screw compressor hermatically sealed water cooled 2X120 TR=240 TR in operation suitable for operation on R-22 , DX evaporator ,Shell and tube condenser , suitable expansion device , chilled water pump 15 HP -3 Nos,condenser water pump 20 HP-3 Nos The entire system to be checked for every month interval up to contract duration and made serviceable in case of any defects observed during the routine check up for system installed at Pegasus Bldg, NAY(K). Note :- (i) Programming/ Software updatation of display panels shall be included in quoted rates (ii) Labour cost of item No. 4&5 here in after shall be deemed to be included in the quoted rate.
Supply and replacement of Transducer of VOLTAS in Dhunhambush chiller of 120TR complete all as specified and directed.
Supply and Replacement of microprocessor display of model PGD1 Carel Make Dhunhambush Chiller controll panel with necessary programming, soft ware installation & panel modification in chiller capacity of (1 x 120 TR ) complete all as specified and as directed .
Supply only of Oil level sensor complte all as specified and directed
Supply only of suction filter complete all as specified and directed
M & L for Cleaning of shell and tube type Chiller shell with capacity of 120 TR by isolating the condenser shell, disconnecting water inlet/outlet completely remove the exisiting water from chiller tubes attach necessary hoses to chiller tube to circulate chemical solution( maic / hydride descaling compound) by using pump for 6-8 hrs and remove the system and after opening both sides of chiller brushing with nylon rod and flushing with fresh water including replacement of gaskets complete leak test and vacuum test and gas charging ,testing as directed. Note:- (i) Works shall be carried out once in 6 months (ii) Nitrogen gas and refrigerent for leak test shall be measured and paid seperately
Material & labour for Monthly servicing of cooling tower of cap 240 TR capacity AC Plant including removing of top Metal grill cover and cleaning the PVC Fills , alignment in proper way, replacement of rusted nuts, bolts with washers etc and clearing bottom tank to remove mud and dust complete all as specified and directed .
Supply and replacement of Fan blade of 2400 mm length, 6 leaf , aluminium alloy, dynamically balanced fanTie rod assembly for 240 TR capacity cooling tower including branch pipes,circular HUB,Flaps,Fittings MS clamps etc complete all as specified and directed.
Supply and fixing in replacement of PVC fills size not less than 600x200x150 mm for existing 300 TR cooling tower complete as specified and directed.
M& L for painting of central AC plant cooling tower with two coats of synthetic enamel spray paint of existing colour paint after preparation of existing surface 240TR capacity all as specified and as directed
M& L for painting of central AC plant 3 x 120 TR for Three chilling units i.e including of compressors,condensers, pumps and motors frames,panel board complete including chiller and condensing water pipe lines(appx length-75 mtr) with two coats of synthetic enamel spray paint of existing colour after preparation of existing surface of each unit and marking set numbers ,SM/MES numbers all as specified and directed.
material and labour for checking of existing condition of air ducts making the arrangement of visualization and the process for disinfection for indoor air quality of AC ducts of inside , connection in between plenum and branches and main plenum withmechanical/Manualprocedures with using air compressor, various type of air nozzles for maintain standard indoor air quality complete all as specified and as directed
M & L Sanitization of ducts by using fogging machine, Bio-cides so as to avoid fungal/Bacterial formation inside the ducts of AHU units/AHU rooms by using with permissable chemicals with suitable equipments complete all as specified and as directed.
M & L for servicing of existing chiller/condenser pump of capacity 20 HP after disconnecting electric connection from motor, removing defective bearing, re-metalling the bearing housing shaft, replacing with new bearings, gland bush, gaskets, gland packing, nut and bolt, air release valve, cooling fan cover and reassemble, refitting and recommissioning including refixing of all electrical connections, testing, painting, base foundation work alongwith channels/accessories, incl transportation to local workshop and back after repair, testing complete all as specified and directed.
Material and labour for leak testing of central AC plant of capacity upto 120 TR including flushing out old moisturised gas and oil and pressuring with nitrogen gas and kept for 24 hrs as per OEM specifications, vaccumising nitrogen and refilling of refrigent gas complete all as specified and as directed. Note :- 1.Nitrogen and refrigent gas will be measured and paid seperately
Supply and charging of Refrigerant Gas R 22 in sealed cylinder complete all as specified and as directed.
Supply and charging of Refrigerant Gas R 410A in sealed cylinder complete all as specified and as directed.
Supply and charging of Refrigerant Gas R 407C in sealed cylinder complete all as specified and as directed.
Supply and charging of Refrigerant Gas R 134 A in sealed cylinder complete all as specified and as directed.
Supply and charging of Nitrogen gas in sealed cylinder all as specified and directed. Note for item no 16 to 20 :1.Empty cylinder will returned to contractor after usage 2.Testing pressure gauges,gas charging PVC leads,technicians and transporting facility ro carring( Maximim capacity cylinders upto appx 1 ton weight) to various AC Plants shall be own arrenged by contractor .
Supply and charging, testing of compressor oil superior quality in sealed barrel all as specified and directed . Make:IOC/HPCL/BPCL
Supply and fix in repair Pre filter box type of efficiency not less than 90% for particles of size down to 20 micron in GI casing of thickness 45/50mm including necessary repairs to AHU filter frames to arrest the air leakage of the following size complete all as specified and as directed :- (a) 610mm x 610mm
(b) 480mm x 455mm
(c) 540mm x 425mm
(d) 455mm x 450mm
(e) 500mm x 500mm
(f) 600mm x 600mm
(g) 600mm x 500mm
(h) 555mm x 535mm
(i) 555mm x 460mm
(j) 600mm x 300mm
(k) 530mm x 420mm
(l) 620mm x 500mm
(m) 590mm x 520mm
(n) 560mm x 480mm
(o) 560mm x 560mm
(p) 610mm x 305mm
Supply and replace MCCB 250 Amps, 415V, 36 KA, 4 pole adjustable type with spreader terminals, including taking down unserviceable MCCB all as specified and directed. Make L&T or equivalent.
M&L for Servicing/repairing of pump starter panel of capacity of 20 HP Star delta type of chiller/condensor pump/CT motor/compressor motor in AC plants, including decarbonizing, tightning of control cable terminations,cable glands, and end termination crimping by attending with skilled Electricians and helper , with neccessary T&P for checking and make functional at Various locations in Naval base Kochi. Note: Any major work identified while attending the above job shall be measured and paid seperatly under relevant item below.
M&L for Servicing/repairing of electric panel of AC Plant, including cleaning of the electric panel by blower, tightning of control cable terminations,cable glands, and end termination crimping by skilled Electricians and helper, with neccessary T&P for checking and make functional at Various locations in Naval base Kochi. Note: Any major work identified while attending the above job shall be measured and paid separately under relevant item below .
Supply and replace digital Voltmeter of range 0-600V, 3 phase all as specified and directed. Make : L&T or equivalent
Supply and replace digital Ammeter of range 0-300A, 3 phase Class 1 all as specified and directed. Make : L&T or equivalent
Supply aand fixing in replacement of temperature gauges for existing pipe lines of central AC plants as per suitable size and model complete all as specified and directed
Supply and fixing in replacement of analouge pressure gauge for existing pipe lines and plants as per suitable (dia) size and model including MS bend pipe upto gauge where required at site complete all as specified and directed.
M & L Steel structural fabrication works fabricated from structural steel sections including nuts,cable trays,clamps bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primary coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fixing of Hard PVC Piping 40 mm up to drain disposal area withsuitable size nitrile rubber insulation suitable for chilled water drain pipe complete all as specified and directed.
Taking down AHU puff panel, cooling coil, filters, cooling coil pan and necessary repair to panels to arrest air leak, packing, refixing/replacing of door hinges, handles, gasket includng repairs to cooling coil pan to arrest leak complete all as specified and as directed.
Supply and fixing in repairs ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe and fixed of size 25mm (Minimum weight 25mm - 455 gms) complete all as specified and as directed.
M & L for servicing of existing AHU motor of capacity upto 15 HP including fan after disconnecting electric connection from motor terminal and opening the motor cover, re-metalling the bearing housing shaft, replacing with new bearings of existing size, cleaning , re assembling including transportation from existing location to workshop and back, refixing of electrical connections, testing after repair , refixing of blower belt, alignment with blower with motor structural frame work and complete painting, recommissioning all as specified and directed.
M & L for taking down AHU blower from the site, replacement of bearings and bearing supports, cleaning the surface and aligning the blades for smooth functioning and refixing after repair, refixing of belt, alignment with motor, recommissioning all as specified and directed .
Material and labour for leak testing of existing cooling coil of capcaity upto 150TR, arresting the leaks of cooling coil by forced pressuring water, brazing works, aligning fins complete all as specified and as directed.
M&L for FRP lining two layer coating with adhesive cohesive chemical solution (min two coat) of required quantity to make it leak proof after preparation of damaged surface area in pipe lines/cooling tower/any other surfaces to make leak proof complete all as specified and as directed.
Supply and fix electric shock proof floor mat near electric panel in AC plant of suitable size 2m x 1m of min thickness 10mm complete all as specified and as directed .
Supply and fix in repairs poly vinyl chloride floor mat in AC plant after filling the pits in floor (if required) and fixing the mat as per existing surface of suitable size with thickness of 3mm, colour light blue complete fixing materials all as specified and as directed .
Taking down any type of false ceiling for AC duct repair work and refix after repair/arresting of water leaking including all requied accessories and make it good complete all as specified and as directed. Note : (i) Any damages made to false ceiling during execution of the above, the same may be repaired/replaced by the contractor without any additional cost. (ii) Cost of additional materials required for making it good as per existing surface deemed to include in the quoted rate.
Repair to thermal insulation of duct complete with skilled labour and necessary equipments complete all as specified and as directed. Note :- (i) The cost for replacement fo nitrile rubber upto 1 sqm to be included in the above item. (ii) Any addl nitrile rubber required beyond 1 sqm for the repair work, the item will be measured and paid separately. (iii) The quoted rate should be included for necessary T&P and Labour.
Supply & fixing of replacement of 13 mm thickness Thermal Insulation of exposed area of ducting covering on ducts using Class O Nitrile Rubber outer sideof exisitng pipelines using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete as per Specifications complete all as specified and as directed. . Make:superlone/aerocell/ K flex/Aeoroflex
AISWARYA ENTERPRISES
National Creations
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .