Loading…
Loading…
Tender Value
₹78.2 L
EMD Value
₹78,187
Closing Date
29 Apr 2026, 5:00 pmClosed
Chief Officer NA,GIDC, Ankleshwar
Replacement of old HPSV Type street light with new LED Street light from Fechom to Kanoriya and Shree Sulfuric to Panama Chokdi in industrial area at NA GIDC Ankleshwar
292851
10 of 2025-2026. Tender Sr. No. 04.
Open
Civil Works - Others
Works
Bharuch
17 documents required · 17 mandatory
₹2,832
Chief Officer, Notified Area, Ankleshwar
₹78,187
1 Apr 2026
1 Apr 2026
1 Apr 2026
29 Apr 2026
1 Apr 2026
Name of Work: Replacement of old HPSV Type street light with new
LED Street light from Fechom to Kanoriya and Shree
Sulfuric to Panama Chokdi in industrial area at NA,
GIDC, Ankleshwar.
Item Description Qty. Unit Amount
Supplying and erecting approved make 10 mtr
Octagonal pole made from HR sheet steel. The pole
should be made as per IS. and shall be coated with hot
dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box
consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mmX7.5mm Din-Rail for MCB
1 Mounting, stud type terminal and arrangement for cable 130 19772.77 No
termination to be erected on foundation as per details
given by manufacturer considering site requirement.
(A) 10 Mtr. Long 70 mm Top X 175 mm bottom
dia, 4 mm thickness with 275 mm X 275mm X 16 mm
Base plate, 4-M24 bolts and 750 mm long J- Bolt.
Approx Weight 145 KG
Providing and erecting Street Light pole bracket
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class GI sleeve
tubing of approx. 45cms.length and suitable for
mm /80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
2 1.5.mtr. length with 110 deg.with vertical plane & 82 626.20 No
suitable welded stays, reducer and with check nuts
complete painted with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint with
following nos of arms.(A) Decorative Single Arm
Bracket 1.5 meter
(B) Decorative Single Arm Bracket 2 meter 48 795.88 No
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrossion free High Pressure
die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminum with diffuser
and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficienacy >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS lumilds/NICHIA/SEOUL/Bridge
lux (USA) make LED used for luminaire. ( fittings
required LM-79 & LM-80 certificates) (Note: below
description have show room ranges of wattage capacity
of LED fittings. The Enginneer in charge may select any
Wattage capacity between the ranges shown.) Street
Light (IP-66), Surge protection - 4KV integral and 10KV
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
non integral, light must have 440VAC line supply
protection. It should with stand 48 hours for 440VAC
line supply. Over Voltage Shut down for mains voltage
> 320 V with auto- recovery feature. Toughned glass
with > 4mm thickness for better impact resistance.
(warranty Period 5 Year) For 120 WLED
Providing and erecting XLPE (IS:7098)(I)-88 ISI marked
armoured cable multistrand Aluminium conductor for
4 1.1 KV. to be laid on wall with necessary clamps or in 3700 153.52 No
existing cable trench / pipe at road crossing or floor of
following size of cables --A) 4 core 16 Sq-mm
B) 4 core 25 Sq-mm 350 190.89 No
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
5 unarmoured copper cable 1.1 KV grade to be erected 1600 137.36 No
as directed of following size. 3 Core 2.5 Sqmm
Making trench in soft soil of suitable width of 90 cms
deep for laying cable or locating the fault all over the
6 run and backfilling the same and making the surface as 3700 55.55 No
normal ground. Up to 25 mm2 Cable
Making trench in hard murrum/Tar Road of suitable
width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back
7 filling the same and making the surface as normal 140 432.28 No
ground. If Additional machinery like hammer driller or
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply by
8 making upto 150mm dia. size of holes at both ends 100 616.10 No
Providing & laying. Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at
required depth for laying of cable. below ground / road
surface for enclosing cable and back filling the same to
make ground as per original. 50 mm dia.
Painting & numbering of street light pole with bracket
10 complete with two coats of Alluminium paint for 130 357.54 No
following size of pole. [c] upto 9 mtr
Construction of RCC Foundation for Octogonal/GRP
11 Pole with Anchor Bolts, as Per Drawings and 130 6666.11 No
Providing and casting in situ CC in grade M-20
(Proportions as per table 9 of IS456 2000 in masses by
weigh batching) using granite, quartze trap metal of size
6 mm to 20 mm for RCC work, including scaffolding
ccentering, formwork, needle vibrated consolidation,
curring complete up to 6 meter depth of height
(excluding cost of reinforcement and heat finishing) with
centering and shuttering/deshttering etc complete for
structure other than water retaiing (below G.L) Footing
(with out form work)
Supplying cutting, bending, binding and placing in
position steel as per plan and design and as per ISS
2502 including cost of steel and binding wire for
13 reservoirs/structures oly including lift up to 5 meter 1 69603.14 MT
height of depth below G.L. for all diameters. High yeild
strength deformed(HYSD)bars/cold twisted deformed
(CTD) bars confirming to IS1786(latest)FE-415
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Providing and erecting 240 V MCB double pole switch
for motor & inductive load (C curve) having 10KA
14 breaking capacity & confirms to IS: 8828 in existing box 130 278.76 No
having following capacity. A) 6 to 32 Amp. (Cat-III)
Solder less crimping type Aluminum lugs conforming to
IS Suitable for Cable of following size evenly crimped
15 with high pressure tools & connected to switchgear 1228 15.15 No
terminals with brass/cadmium plated nut bolts in an
approved manner. 16/25 Sq.mm.
Pipe type earthing having 150 cms.long and 2.5 cms.
dia. galvanised iron pipe with coupling and buch buried
in specially prepared earth pit complete with necessary
8 SWG earth wire.
Dismentalling/ Cutting of Existing Street Light pole up to
17 9 meter height with bracket and fitting with hydra. 171 452.48 No
18 Hiring of tractor with Trolley, driver, diesel etc only for 5 1806.45 No
minimum 8 hr working per day.
Providing & erecting GI MCB channel (Size: 1 Meter (L)
19 X 35 mm (W) DIN RAIL. Complete fitting with GI nut 150 58.00 Nos
Supply and Installation of 60A 4 way Backelite
20 connector strip for Termination. 500 67.00 Nos
Supply and Installation of MS Cover Box for Octagonal
pole Terminal with Nut Bolt and connecting Chain
21 having size: A) 310 mm(L) X 130mm (W) X 3 mm 250 850.00 Nos
B) 360mm (L) X 130 mm (W) X 3 mm thick. 250 850.00 Nos
Approved make Four Pole LT Heavy Duty Switch
Disconnector Fuse Unit Cubical type for panel mounting
complete with operating mechanism suitable to operate
on 415V A.C. With HRC fuses of suitable load
confirming to IS. 13947 (Part I & III). of following
capacities. Cat-III 125 Amp
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Supply and fabrication of Street light three phase Iot
GSM/GPRS Central Control & Monitoring System
(CCMS) Control Panel with all switch gear, bus-bar,
nos LCD Display, Energy Saving Feature and Spare
Relay facility having 10 years of reserve battery for RTC
with 50 programmable schedule, month-wise offset
settable facility, astronomic sunrise/sunset time
programing inbuilt for yearlong schedule. Operating
voltage @440 V ac with over voltage & short circuit
protection. 2 hours battery backup for street light
controller. Panel to have 1 nos of 3 phase- class
Energy Meter for Energy & fault monitoring on CCMS
web dashboard. power and control wiring etc complete
as per specification given, panel Enclosure fabricated in
MS 14 Gauge sheet & Enclosure size is 1000 mm x
1000 mm x 500 mm with 500 mm height mounting
stand with double door type. All incoming and outgoing
cable termination should be suitable for ring type lugs
termination, Panel suitable for 4 Nos out going circuits
for 4 C x 16 Sq.mm cable and 1 Nos incoming cable of
size 4C x 50 Sq.mm with following switch gear
complete connection. Panel suitable for outside open
area installation and whether proof with canopy, Panel
should be design with Double door with two separate
compartments with two inner door for cable termination
and switch gear. Panel Having IP65 Rating. Local
communication facility via mobile application in case of
GPRS connectivity frailer.
63 Amp Four Pole MCCB 36KA with thermal magnetic
Release -- 01 No
R-Y-B Indication Lamp 230 V AC
1 Nos 4 Pole ELCB
Door Switch for unauthorized access & tamper
Detection & Accelerometer for panel movement
detection &tamper alert
3 Nos of 3 Pole Contactor (ML-2 32A AC3 X 3 Nos)
CCMS Controller with timer -
2 Pole 2way Selector switch - 01 No
6A Control SP MCB, 10KA -01 No
O/G 32 A SP MCB, 10 KA - 16 No
Power terminal CBT /KBT type - 20 No's
Power Wiring 16 SQ.mm,25 Sq.mm, and 50 Sq.mm
copper flexible cable
1 Nos 4g / 5G Sim with slot with necessary data pack
5 Year Cloud Server Subscription
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Supplying & erecting funnel type earthing having earth
plate of 600 mm x 600 mm x 3.15 mm thk. Copper
earth plate burried in specifically prepared earth pit
mtr. below ground with 40 Kg. Charcoal and 40 Kg. salt
with alternate layers of charcoal & salt, 38 mm dia
Medium Class G. I. Pipe with funnel with a wire mesh
for watering & bricks massanary block, C. I. cover
complete as per para 7.3 of IS : 3043 with necessary
length of double 8 SWG copper earth wire - bolted to
the plate and covered in 38 mm dia. G. I. pipe - 2.5 mtr.
long complete connected to the nearest switch gears
with end socket as per direction & duly tested by earth
tester confirming to ISS & as per drawing - (1 Job per
Distribution Box)
Total of Part-1
(Part-2) Buy Back of Scrap Material
1 MS Scrap 8000 32.00 Kg
2 OLD HPSV Fitting 180 350.00 Nos
Total of Part-2
(Part-1 - Part-2) Rs.
I / We hereby agree carry out the work at I / We hereby agree carry out the work
the rate given in Schedule B @ _______ % at the rate given in Schedule B @ ______ %
Net Amount Rs. _______ Net Amount Rs. _______
Important Note:
1. The rates offered shall be inclusive of all applicable taxes (1% LWC, ESIC, PF,
packing, forwarding, insurance, loading, unloading, shifting & transportation at
store/ site of work at Ankleshwar Notified Area.)
The rates offered by Bidder shall be Exclusive of GST.
2. I/We have read the conditions mentioned in this tender & agree to abide by the
3. Please note that the agency in whose favor the tender is finalized by the
competent authority shall have to submit the document like insurance of the staff
engaged RPFC No. Labour license etc. and documents for vehicle.
4. The successful bidder in whose favor the tender is finalize by the competent
authority has to enter in to an agreement with Notified Area office in B-1
agreement form, the conditions & clauses of the agreement shall be binding to the
agency. If the bidder desires to study the same, the same is available in the office
of the Notified Area Officer, GIDC, and Ankleshwar during office hours of the
5. 1% labour welfare cess on the bill amount will be deducted from the each RA bill
as per Govt. norms.
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Sr. No 4 Panama.pdf
BOQ 4 .pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .