Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC VILL PO KAMPA NEAR ASHRAM DIST NORTH 24 PGN KOLKATA WB | 24 PARAGANAS NORTH | WEST BENGAL | 743193 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.9 L+₹2.5 L (8.05%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹36.6 L+₹5.3 L (16.8%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹40.6 L+₹9.3 L (29.6%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹42.1 L+₹10.8 L (34.5%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹33.7 L
EMD Value
₹67,400
Closing Date
14 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata 700120
PROVN OF SEPTIC TANK AT REAR SIDE OF BLDG NO NP-12/14A AND SPECIAL REPAIR TO BLDG NO NP-136 AND T-81B AT VARIOUS LOCATION OF KANCHRAPARA UNDER GE BARRACKPORE
2023_MES_580659_1
8744/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹67,400
Yes
30 Mar 2023
13 Feb 2023
16 Mar 2023
13 Feb 2023
14 Mar 2023
28 Feb 2023
Amount
PART-I Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frames (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position for portions not otherwise specifically provided for (Reinforcement cut as required to be facilitate demolition) complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description etc complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards, any thickness including cover fillet complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Surface dressing not exceeding 15 cm deep in soft loose soil complete all as specified and as directed.
Excavation over areas not exceeding 1.5m deep & getting out soft/loose soil complete all as specified and as directed.
Excavation over areas exceeding 1.5m but not exceeding 3.00m deep and getting out soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes, laying of drain pipes, pipe line, cable, foundation for manhole etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
M&L for Moorum/Red Bajri filling in floors or pavings, layers not exceeding 15 Cm thick spread, levelled and rammed including watering complete all as specified and directed.
M&L for anti termite treatment of treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for broken brick hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete for embedding of post complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in coping, bed plates, fixing of hold fast and like etc including necessary form work complete all as specified and directed.
M&L for RCC(nominal mix) (1:1.5:3) type A-1(using 20mm graded crushed stone aggregate) used in beams, cantilivers, lintel over 1.5m span and like etc complete all as specified and as directed.
M&L for RCC (nominal mix) (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for providing precast reinforcement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders(for stone wallin), corbels, brackets etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar(1:4) complete with joints to match complete all as specified and as directed.
M&L for Cutting out concrete blocks, slabs, brickwork (except block or slab) set in cement mortar(1:6) or stone masonry(in alternate course), forming tooth-ings for and bonding new work in mortar into old work, including new materials entering old wall complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks locally available best quality bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
Ditto all as per Item No.27.00 here-in-before but except brick complete all as specified and directed. (Note :- Old bricks obtained from item No. 4.00 here-in-before)
M&L for cutting holes in brick walls built in cement mortar to a depth of embedded portion exceeding half brick but not exceeding one brick for inserting holdfasts and making good dismantled portion in cement concrete (1:2:4) Type B-1 as required complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
Providing form work to sides and soffits of foor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings, shelves and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed.
M &L for 35mm thick plain, second class hard wood, framed, panelled shutters (two panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F of 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section(as per IS-204(Part II) : 1992) and fixed complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F of TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 5mm dia and over cut to and including 10mm dia as in stirrups, spaces and binders binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for rolled mild steel work in tubular trusses and tubular posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F of steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S&F of steel windows with side hung shutters (gauged) including projection type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive wiremesh complete all as specified and directed.
S&F of steel windows with side hung shutters (gauged) including projection type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wiremesh complete all as specified and directed.
S&F of pressed steel frames for door of size 105mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate)including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
S&F of 0.8mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip & straight flashing (legth & girth as fixed) with grade of zinc coating 275 gm per sqm complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in wall/cladding, fixed with self tapping screws complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 6mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in levelling course of floor complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base to footpath, floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & hard standing including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in floor etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for 18-20mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 18-20mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over and including 10mm cement plastering in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S&F of 3mm thick & 38 mm wide glass dividing strip, inserted in position as in floor complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on brick, concrete surfaces in cement mortar (1:4) mixing with WPC @ 200 ml /50 Kg of cement or as per manufacturer's instructions, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for neeru finish to plastering surface complete all as specified and as directed.
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
Material & Labour for applying two coats of 100% Premium acrylic emulsion paint(using AIR-LESS PAINT SPRAYER) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER including preparation/levelling of old surface of wall using manual sand papers(where reqd) of approved grade complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with glazing pins/ gasket suitable for steel frames in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F of 3.0mm thick figured glass pin head type & glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 200mm bore including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
M&L for 200 mm dia reinforced concrete pipes, class NP-2, laid and jointed complete with collars complete all as specified and directed.
M&L for 200 mm dia bends, class NP-2, laid and jointed complete complete all as specified and directed.
S&F of 150mm long aluminium anodised extruded alloy handle fabricated type (as per IS-208: 1996) complete all as specified and directed.
PART-II Taking down unserviceable submain wiring aluminium etc and making good the disturbed surfaces of walls/floor etc matching with the existing surface.
Taking down old unserviceable existing service/UG cable all as specified and directed.
M&L for disconnecting electric supply, taking downfan, sealing cable ends, dismantling blades ceiling fan any size from existing position and depositing to MES yard all as specified and as directed by EIC
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch.
One 3 pin 5/6 amps socket point controlled by one 6 amps switch on same board .
One 3 pin socket outlet 5 Amps on the independent board.
All as per Item No.77.00 here-in-before but point wiring with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm for one 6pin, 6/16Amps socket outlet point controlled by one 16Amp switch on independent board complete all as specified and directed.
S&F of switch piano flush button single pole one way 5/6 Amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole one way 15 Amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F Socket outlet, flush type 2 in 1, 5 pin, 5 Amps, 240 volts all as specified and as directed.
S&F Socket outlet, flush type 2 in 1, 3 pin, 5 and 15 Amps, 240 volts all as specified and as directed.
S&F of ceiling rose, surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of angle lamp holder, PVC/polycarbonate type, ISI marked complete all as specified and directed.
S&F of stepped type (0-4/5 step) electronic fan regulator 120mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 for tubes /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F MCBs SP, 6 to 32A mps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F MCBs SPN 32 Amps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
S&F of MCCB 3pole, 415 V fixed type of copacity 63 Amps, 16 KA, with connecting accessories complete all as specified and as directed.
S&F of vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface including taking down old unserviceable DB(including MCB any type & capacity) complete all as specified and as directed. ( Note- MCCB 3 pole 63 amps as main incomer will be measured and paid separately)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable DB(including MCB any type & capacity) complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 115mm x .75mm laid dry flat complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for 50mm bore GI pipe (Light Grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp including taking down old unserviceable pipe complete all as specified and as directed.
Boaring holes horizontally under road without damaging the surface of road(minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of dia not exceeding 100 mm dia for passing of UG cable all as specified and as directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket complete all as specified and directed.
S&F of 35/36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable including taking down old unserviceable street light fittings complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F and testing ceiling fan complete with all accessories, 230V, 1200mm sweep, BEE5 star rated, 03 blade type, double ball bearing copper wound, 50Hz, AC supply, all as specified and directed by EIC (Make : Crompton Greaves Aura 3 blades/Havells cat No.ES-50 HS/Bajaj Excel 3 blade or equivalent model/cat No as per Appx 'D' mentioned in PS here-in-after) (Note:- Rate quoted includes Fan clamp suitable for 1200mm ceiling fan)
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable GI wire earthing complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M/S. A.B. Consultant
M S SAWASTI ENTERPRISE
INDUSTRIAL CONSTRUCTION
CHATTERJEE ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .