| 1 | L1₹23.3 LAccepted-AOC | ₹23.3 L Quoted ₹24.4 L | L1 | Accepted-AOC Accepted being lowest and reasonable one. |
| 2 | L2₹26.9 L+₹2.4 L (9.98%)Rejected-Finance | ₹26.9 L+₹2.4 L (9.98%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹31.2 L+₹6.8 L (27.6%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | ₹31.2 L+₹6.8 L (27.6%) | L3 | Rejected-Finance Rejected being L3 |
| Sl No | Description | Qty | Unit | R N Enterprises L3 | Goyal Engineers L2 | M/s Seerat Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed by Engr-in-Charge. | 1,422 | PER POINT | 5 ₹7,110 | 2 ₹2,844 Lowest | 5 ₹7,110 |
| 2.00 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20 mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.
NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.
2. All chases will be cut by chase cutter only. | 800 | PER POINT | 260 ₹2,08,000 | 220 ₹1,76,000 | 180 ₹1,44,000 Lowest |
| 3.00 | Description all as per item No 2.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed by Engr-in-Charge. | 125 | PER POINT | 100 ₹12,500 | 70 ₹8,750 Lowest | 70 ₹8,750 Lowest |
| 4.00 | Description all as per item No 2.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed by Engr-in-Charge. | 170 | PER POINT | 260 ₹44,200 | 220 ₹37,400 | 150 ₹25,500 Lowest |
| 5.00 | Description all as per srl item No 2.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed by Engr-in-Charge. | 115 | PER POINT | 300 ₹34,500 | 280 ₹32,200 | 250 ₹28,750 Lowest |
| 6.00 | Supply and fixing modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed by Engr-in-Charge. | 1,065 | EACH | 24 ₹25,560 | 22 ₹23,430 | 20 ₹21,300 Lowest |
| 7.00 | Supply and fixing modular switches, one way, 16/20 Amps, one module, 230 volt , AC supply, complete all as specified and directed by Engr-in-Charge. | 115 | EACH | 45 ₹5,175 | 60 ₹6,900 | 40 ₹4,600 Lowest |
| 8.00 | Supply and fixing modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed by Engr-in-Charge. | 295 | EACH | 40 ₹11,800 | 45 ₹13,275 | 30 ₹8,850 Lowest |
| 9.00 | Supply and fixing modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed by Engr-in-Charge. | 115 | EACH | 55 ₹6,325 Lowest | 80 ₹9,200 | 60 ₹6,900 |
| 10.00 | Supply and fixing fan regulator step type one module / 2 module, 100 W 230 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge. | 90 | EACH | 155 ₹13,950 | 155 ₹13,950 | 150 ₹13,500 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Dec 2025, 6:00 pmClosed
LT COL CHETAN KOTKAR, GE (SOUTH) AMBALA
GE (SOUTH) AMBALA CANTT
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND DAY TO DAY MAINT ASSOCIATED WORKS EARTHING LOAD LINE DISTRIBUTION SYSTEM AND ALLIED ESSENTIAL WORK IN CERTAIN MD ACCN AT SOUTHERN ZONE UNDER GE (SOUTH) AMBALA CANTT
2025_MES_740111_1
GE(SOUTH)/AMB-67/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹98,000
Yes
12 Feb 2026
17 Nov 2025
10 Dec 2025
17 Nov 2025
8 Dec 2025
2 Dec 2025
17 Nov 2025 - 1 Dec 2025
Amount
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed by Engr-in-Charge.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20 mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 2.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed by Engr-in-Charge.
Description all as per item No 2.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed by Engr-in-Charge.
Description all as per srl item No 2.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed by Engr-in-Charge.
Supply and fixing modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed by Engr-in-Charge.
Supply and fixing modular switches, one way, 16/20 Amps, one module, 230 volt , AC supply, complete all as specified and directed by Engr-in-Charge.
Supply and fixing modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed by Engr-in-Charge.
Supply and fixing modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed by Engr-in-Charge.
Supply and fixing fan regulator step type one module / 2 module, 100 W 230 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and fixing modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed by Engr-in-Charge.
Supply and fixing modular blanking plate 1 module complete all as specified and directed by Engr-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through in existing conduit not less than 20 mm dia with FRLSH )accessories, concealed on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.2 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately . 2. All chases will be cut by chase cutter only.
Description all as per item No 13.00 here in before but for socket out let point 5 Amps on same board,complete all as specified and directed by Engr-in-Charge.
Description all as per item No 13.00 here in before but for socket out let point 5 Amps on independent board,complete all as specified and directed by Engr-in-Charge.
Description all as per item No 13.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, , complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply,, complete all as specified and directed by Engr-in-Charge.
Supply and fixing bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply,, complete all as specified and directed by Engr-in-Charge.
Supply and fixing socket outlet 3 pin 6 amps, 230 volt. flush type,, complete all as speciied and directed by Engr-in-Charge.
Supply and fixing socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified by Engr-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal, complete all as specified by Engr-in-Charge.
Supply and fixing fan regulator electronic step type ,230 Volts, AC supply,, suitable for ceiling fan any type/make/sweep, complete all as specified and directed by Engr-in-Charge.
Supply and fixing door bell electric ,ding dong /musical type, single phase 230 volts, complete all as specified by Engr-in-Charge.
Supply and fixing sheet metal enclosure SP with two pin and earth plug and socket including metal clad top with one single pole MCB 20 Amp complete all as specified and directed by Engr-in-Charge.Make : HPL, Cat Part No MDBSPMT20 / Indo Asian, Cat Part No 811955 / Havells, Cat Part No DHPUSN020 or equivalent makes as mentioned in Appendix 'B'.
Supply and fixing of LED light fitting 1x20W , 220V, AC with Aluminium housing with batten type with driver , holder including 20W LED tube light, Cool White/Warm White, duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/watt for connecting up with three core flexible copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed.Make : HPL Cat Part No HLPT51520CW / Orient Taskline AL, Cat Part No LBLN-20-C-SQ-AL,Bajaj LED Batten Cat Part No BCLAB 20W LED P or equivalent makes as mentioned in Appendix 'B'.
Supply and fixing channel for fixing of LED tube rod of CRCA body suitable for 20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge. ( Tube rod shall be measured and paid for separately ).Note: - Channel must be get approved from Engr in charge to check fesibilty i.e. one end contact or both end contact.
Supply and fixing in repair 20W LED tube rod, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed by Engr-in-Charge. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or both end contact for fixing in existing LED fittings .Make : HPL Cat Part No HLPT81420CW, Orient Powerline SP, Cat Part No LTPS-20-C, Halonix LED Batten Cat Part No HLTLD-04-20-CW or equivalent makes as mentioned in Appendix 'B'
Supply and fixing batten type with surface mounted LED tube light fitting with high efficient diffuser mirror light, Aluminium housing in CRCA body suitable and including 10 watt LED energy efficient, AC 220-240 volts,duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/watt 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge.Make : Orient Taskline AL, Cat Part No LBLN-10-C-SQ-AL / HPL Cat Part No HLPT51510CW, Halonix LED Batten Cat Part No HLB-03-10-CW-AL-SQ or equivalnet makes mentioned in Appendix 'B'.
Supply and fixing bulk head light fitting, 10 watt, LED Energy efficient with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and directed by Engr-in-Charge. Make : HPL Cat Part No HLPLEDBH10W(CW) / Orient Cat Part No LIBHP-10-C-V1/Bajaj Cat Part No BIBWP 10W LED or equivalent makes as mentioned in Appendix 'B'
Supply and fixing of LED lamp 9 watt B-22 basecomplete including taking down old existing lamp any type complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair of bracket for security light made up of 25 mm dia suitable for security light, 0.9 metre long GI pipe, light grade, 120 degree bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired, duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/watt and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge.Make : Havells Cat Part No LHETAVU7PA7J030 / Orient Cat Part No LSFT-030-C/Halonix Cat Part No HLSLD-09H-30-CWL-R or equivalent makes as mentioned in Appendix 'B'
Supply and fixing LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired, duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/watt and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge.Make : Havells Cat Part No LHETAVU7PA7J045 / Orient Cat Part No LSFT-045-C/Halonix Cat Part No HLSLD-09H-45-CWL-R or equivalent makes as mentioned in Appendix 'B'
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6.0 sqmm,1100 Volt grade, drawn in and including rigid non metallic PVC medium grade 25mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6.0 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. NOTE: - 3 run of 6.0 sqmm cable with concealed conduct shall be measured as 1 unit.
All as per Item No 35 above but for Material and labour for sub main wiring of 4.00 sqmm. NOTE:- 3 run of 4.0 sqmm cable with concealed conduct shall be measured as 1 unit, complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) Taking out old unserviceable earthing complete all as specified and directed by Engr-in-Charge. NOTE : - (i) The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates. (ii) The earthing shall be tested for desired result, if not found within limits the earthing will be redone without any extra cost.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with suitable size of rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type ,125AMPS ,25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviceable MCCB/DBs including MCBs complete all as specified and directed by Engr-in-Charge. Note: (i). Painting shall be done with Powder Coated Finish. (ii). PU (Polyurethene ) gasket shall be used in DB.Make : HPL, Cat Part MDBVDD04-250TAB / Indo Asian, Cat Part No 812045 / Havells, Cat Part No DHDLVDRWGOFO04 or equivalent makes as mentioned in Appendix 'B'
All as per Item No 38 above but VTPN DB alongwith MCCB 4 pole,100AMPS 16 KA as incomer and MCBs as out going complete all as specified and directed by Engr-in-Charge.Make : HPL, Cat Part MDBVDD04-250TAB / Indo Asian, Cat Part No 812045 / Havells, Cat Part No DHDLVDRWGOFO04 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including suitbale rating of fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets and making good the disturbed surface matching with existing surface including taking down existing unserviceable DBs including MCBs complete all as specified and directed by Engr-in-Charge. Note: (i). Painting shall be done with Powder Coated Finish. (ii). PU (Polyurethene ) gasket shall be used in DB.Make : HPL, Cat Part BEDBDD08 / Indo Asian, Cat Part No 811807 / Havells, Cat Part No DHDNSHODAW08 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair SPN distibution board 4 way, double door, IP 43, as per IS 8623 including suitbale rating of fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets and making good the disturbed surface matching with existing surface including taking down existing unserviceable DBs including MCBs complete all as specified and directed by Engr-in-Charge. Note: (i). Painting shall be done with Powder Coated Finish. (ii). PU (Polyurethene ) gasket shall be used in DB.Make : HPL, Cat Part BEDBDD04 / Indo Asian, Cat Part No 811805 / Havells, Cat Part No DHDNSHODAW04 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI complete all as specified and directed by Engr-in-Charge. Make : HPL, Cat Part NTSPB6-32 / Indo Asian, Cat Part No 811008, 811010, 811012, 811013, 811014, 811015 / Havells, Cat Part No DHMGBSPF006-032 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, complete all as specified and directed by Engr-in-Charge.Make : HPL, Cat Part NTSPB40,NTSPB50-63 / Indo Asian, Cat Part No 811016,811017 / Havells, Cat Part No DHMGBSPF040-63 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series, complete all as specified and directed by Engr-in-Charge.Make : HPL, Cat Part NTSPNB40,NTSPNB50-63 / Indo Asian, Cat Part No 811035,811036, 811037 / Havells, Cat Part No DHMGCSPF040-063 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair MCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal release adjustable type, ICS=ICU=100% complete all as specified and as directed.Make : HPL, Cat Part TAB160CY125AC4P / Indo Asian, Cat Part No 830273 / Havells or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair MCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal release adjustable type, ICS=ICU=100% complete all as specified and as directed.Make : HPL, Cat Part TAB160DX100AC4P / Indo Asian, Cat Part No 830242 / Havells or equivalent makes as mentioned in Appendix 'B'
Supply and fixing 1100 volts grade,ISI marked heavy duty cable PVC insulated,multi stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable circular/flat of size 10 Sqmm, including all incoming and outgoing connection with proper size of thimble complete all as directed and specified.
All as per Item No 47 above but one twin core cable circular/flat of size 06 Sqmm complete all as directed and specified.
Material and labour for taking down existing lighting fiting any type/size/Make/capacity i.e T/L, Surface/ Recess Panel, flame proof, wall light, bulk head, mirror light etc and re-fixing the same after minor repair/cleaning including replacement connection wire with suitable size coper wire twin core 0.75 sqmm for connection from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge.
Material and labour for attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit including no light , earth leakage, short cicuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centre alongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working days for rectification of complaints and resubmit the dockets after completion of each job on the same day. If contractor is failed to submit the docket within 48 hours after issuing of dockets , the contractor will liable to pay the penalty i.e. 20.00 per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates.
Supply only switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply,, complete all as specified and as directed.
Supply only switch, single pole two way 6 Amps, 230 volts AC circuit, complete all as specified and as directed.
Supply only switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, complete all as specified and as directed.
Supply only bell push piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and as directed.
Supply only socket outlet piano 3 pin 6 amps, 230 volt. flush type,, complete all as specified and as directed.
Supply only socket outlet piano 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed.
Supply only ceiling rose surface bakelite 65x50mm, 3 terminal,ISI marked complete all as specified and as directed.
Supply only fan regulator electronic step type ,230 Volts, AC supply,, suitable for ceiling fan any type/make/sweep, complete all as specified and as directed.
Supply only door bell electric ,ding dong /musical| type, single phase 230 volts, complete all as specified and as directed.
Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
Supply only switch modular 6 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type, complete all as specified and as directed.
Supply only switch modular 16 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type, complete all as specified and as directed.
Supply only socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type, complete all as specified and as directed.
Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type, complete all as specified and as directed.
Supply only fan regulator step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete with and including necessary frame and cover i.e. inner and outer plate as per existing make and type, complete all as specified and as directed.
Supply only 6Amp bell push modular with and including necessary frame and cover i.e. inner and outer plate as per existing make and type, complete all as specified and as directed.
Supply only Fan condenser 2.5 mfd complete all as specified and as directed.
Supply only Cable PVC copper conductor flexible twin core 0.75 mm, complete all as specified and directed by Engr-in-Charge.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, complete all as specified and as directed. Make : HPL, Cat Part NTSPB6-32 / Indo Asian, Cat Part No 811008, 811010, 811012, 811013, 811014, 811015 / Havells, Cat Part No DHMGBSPF006-032 or equivalent makes as mentioned in Appendix 'B'
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, complete all as specified and as directed.Make : HPL, Cat Part NTSPB40,NTSPB50-63 / Indo Asian, Cat Part No 811016,811017 / Havells, Cat Part No DHMGBSPF040-63 or equivalent makes as mentioned in Appendix 'B'
Supply only MCB single pole and neutral 240 volts, 32 Amps,10KA, 50 Hz, 'B' Series, complete all as specified and as directed.
Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series,complete all as specified and as directed.Make : HPL, Cat Part NTSPB40,NTSPB50-63 / Indo Asian, Cat Part No 811016,811017 / Havells, Cat Part No DHMGBSPF040-63 or equivalent makes as mentioned in Appendix 'B'
Supply only 3 pin Top plug, 16 Amp , 240 volts AC , complete all as specified and directed by Engr-in-Charge.
Supply only metal clad top plug, AC Plug, 20 Amp, 230 Volt AC complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down old existing wall light fitting of any description and in any position and Supply and fixing aesthetically designed wall bracket light of metal base with glass and B22 holder including 7 watt LED lamp Warm White & clear diffuser including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed by Engr-in-Charge.Make : Havells Cat Part No LHFOAJE1TN1I060 /Wipro Cat Part NoBW02BB/Halonix Cat Part No HLWB-01-B22 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing in repair post top lantern LED 30 W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED 30W and accessories internally pre wired, duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/watt and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed by Engr-in-Charge. Make : HPL Cat Part No HPLLEDPCR30W /Orient ,Cat part LLAS-30-C/Halonix Cat Part No HLPT-S04-30CW or equivalent makes as mentioned in Appendix 'B'
Supply and fixing of LED based Bollard light 10 watt with aluminium pipe housing with glare free PMMA Diffuser, IP 65, dia not less than 65 mm, duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/watt including necessary excavation & PCC work etc complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge.Make : HPL Cat Part No HPLLEDBPR10W /Orient ,Cat part LLSBL-10-W/Halonix Cat Part No HLOB-05-10-CW or equivalent makes as mentioned in Appendix 'B'
Disconnecting and taking down old existing recess/surface mounting ceiling light fitting of any description and in any position and Supply and fixing surface/ recess mounting LED slim square/round down lighter 15 W LED with high efficient LEDs glare free opal diffuser madeup of PDC AL with IP 20 Protection ,PF not less than 0.9,ISI marked including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed by Engr-in-Charge
Supply and fixing LED flood light highly efficient integral type, made of pressure die cast aluminium housing with 10 KV SPD lens & toughened glass IP 66, energy efficient provided with including LED 70 watt LED, duly marked with relevent IS, PF not less than 0.9,lumen efiicacy not less than 100 lumen/wattwith provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair driver for bollard light, recess/ ceiling light of 10 to 20 watt of suitable size and easy installation as per existing make all as specified and as directed.
Supply and fixing in repair driver for post top lantern and security light of of 30 to 45 watt of suitable size and easy installation as per existing make all as specified and as directed.
Supply and laying of LT undergroung cable, XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty), 1100 volts grade, with stranded aluminium conductor of size 6 Sqmm 2 Core with suitable size of PVC Concealed/ surface conduit alondwith necessay fixing accessories (for Gate lights, Garden Lights and Garrage) complete all as specified and directed by Engr-in-Charge.
Supply and fixing for GI protection pipe of 40mm dia light grade,ISI marked for cable protection including all fittings laid in trenches or fixed on pole, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes, laying of cable etc not exceeding 10 Square metre on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
Material and labour for unwashed dry sand cushioning for cable protection ,filling in trenches/ducts, complete all as specified and as directed.
Material and labour for old size bricks sub class 'B' for cable protection laid along length of cable complete all as specified and as directed.
Material and labour for taking down existing light fitting of any type alongwith GI pipe/ pole of any dia / any size and Supply and fixing of MS pipe (Hot dipped Galvanized) decorative pole in two sections i.e Top pipe not less than 75 mm outside dia x 1500 mm long and Bottom pipe not less than 110mm outside dia x 500 mm long, thickness of pipe not less than 3 mm with base plate 250 x 250 x 12mm thick having 14mm dia hole for fixing of foundation 'J' bolts of size 12mm dia x 450 mm "J" including 115 x 200 mm long utility window in pole, fixing of suitable size nuts/bolts and washers including Tripple layer metallic PU paint (Etching, Epoxy & PU) having Embalishment aluminium castiing suitable for and alongwith 35 Watt Warm white LED post top lantern IP 65 environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs clear cover offers bright illumination including all fixing accessoreis including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed by Engr-in-Charge. Note : (i) Quoted rates shall be inclusive of excavation, taking down existing pole, all fixing acessories & PCC 1:3:6 for fixing of pole & post top lantern. (ii) Drawing of pole must get approved before installation.. (iii) MS pipe of pole (Top & Bottom) should be as per latest standard.
Supply, laying and testing cable XLPE Insulated ,armoured, heavy duty electric cable 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core,ISI marked including taking down exising service wire of any size all as specified and directed by Engr-in-Charge.
Supply and fixing ,Air ventilator made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200 copper winding of sweep 250 mm including,making of suitable size hole for fixing where required and taking down existing fan all as specified and directed by Engr-in-Charge.
Supply and fixing of LED based Bollard light not less than 15 Watt with aluminium pipe housing with glare free PMMA Diffuser, IP 65 of height not less than 1000mm and dia not less than 65mm,,PF not less than 0.9,lumen efficacy not less than 100 lumen/watt including necessary excavation & PCC work etc complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge.Make : HPL Cat Part No HPLLEDBPR15WW /Orient ,Cat part LLRBL-15-W-B/Halonix Cat Part No HLOB-05-15-CW -1Mor equivalent makes as mentioned in Appendix 'B'
Supply and fixing MCB DB 4 way TPN double door powder coated complete alongwith suitable size of rated Bus bar, 415 Volts rated bus bar IP 43 protection, suitable for MCB 4 Pole 63 Amp as incommer. Note: Thimble/lugs of rating of MCB TPN should be used with wire for fixing in the MCB. complete all as specified and directed by Engr-in-Charge. Note: (i). Painting shall be done with Powder Coated Finish. (ii). PU (Polyurethene ) gasket shall be used in DB.Make : HPL, Cat Part MDBVDD04-ISO, MDBVDD04-ISO63 / Indo Asian, Cat Part No 811856, 811857 / Havells, Cat Part No DHDPTVODRW04 or equivalent makes as mentioned in Appendix 'B'
Supply and fixing MCB TPN 63 Amps, 440 volt,10 KA 'B' curve, complete all as specified and directed by Engr-in-Charge. Make : HPL, Cat Part NTTPNB63 / Indo Asian, Cat Part No 811220 / Havells, Cat Part No DHMGCTNF063 or equivalent makes as mentioned in Appendix 'B'
Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposit to store for repair all as specified and directed.
Supply and fixing in repair fan condencer 2.5/ 4 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan all as specified and directed.
Supply and fixing in repair ball bearing of suitable size and capacity, for ceiling/ Exhaust fan all as specified and directed.
Supply and fixing in repair shaft of suitable size and capacity for ceiling/ Exhaust fan all as specified and directed.
Supply and fixing in repair hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins, canopy suitable for any type of fans & down rods complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of ceiling fan using synthetic enamel paint in two coat over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler complete all as specified and directed by Engr-in-Charge.
Material and labour for hanging only ceiling fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed.
Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed by Engr-in-Charge. NOTE : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested. (iii) All the fans shall be repaired/rewind at AGE E/M Store yard.
Supply and fixing of GI fan rod 600 mm long , 15 mm dia medium duty with superior quality and nut and bolts with locking arrangement complete with all as specified and directed by Engr-in-Charge.
Supply and fixing of GI fan rod 1.0 meter long , 15 mm dia medium duty with superior quality and nut and bolts with locking arrangement complete with all as specified and directed by Engr-in-Charge.
Material and labour for taking down Exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposit to store for repair all as specified and directed.
Material and labour for rewinding of Exhaust fan/Wall Mounted Fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed by Engr-in-Charge. NOTE : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested. (iii) All the Exhaust fans/ Wall Mounted Fan shall be repaired/rewind at AGE E/M Store yard.
Supply and fixing in repair metal exhaust fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing only exhaust fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc all as specified and directed.
Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed by Engr-in-Charge. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
Description all as per Item No 109 above but for gayser of cap 35/ 50 ltrs capacity, complete all as specified and directed by Engr-in-Charge.
Supply only heating element of capacity 2 KW of geysers of any make complete all as specified and directed by Engr-in-Charge.
Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity,ISI marked complete all as specified and directed by Engr-in-Charge.
Supply only thermostat suitable for the any make of Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed by Engr-in-Charge.
Supply only thermostat suitable for the any make of Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed by Engr-in-Charge.
Supply only temperature resistent SS braided PVC Pipe heavy duty suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete as an directed.
Supply only Non-return valve 15mm / 20mm dia of brass as per requirement complete all as specified and directed by Engr-in-Charge.
Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed by Engr-in-Charge.
Supply only Geyser storage inner tank made out of stainless steel sheet suitable for 25 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Supply only geyser storage inner tank made out of stainless steel sheet suitable for 50 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair copper cable PVC insulated and PVC sheathed flexible size 2.5Sqmm 3 core 1100 Volt Grade, complete all as specified and directed by Engr-in-Charge.(Cable shall be in suitable length as per site requirement).
Supply and fixing in repair PCB unit of suitable size for BLDC Ceiling fan of 1200mm sweep as per make of ceiling fan, single phase, 240 V complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable energy meter and Supply and fixing electronic energy meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, Voltage and KWH complete all as specified and directed by Engr-in-Charge.
NOTE:- Amount of credit of Rs. 1,12,418.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Goyal Engineers (BID ID -3491402)
R N Enterprises (BID ID -3490726)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tenderdocuments67.pdf
Tender Documents • 0.81 MB
BOQ_828734.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .