Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.7 LAccepted-AOC V P O NALPUR P O KHARKHODA DISTT MEERUTH UP | MEERUT | UTTAR PRADESH | 245206 | L-1 | Accepted-AOC Found Lowest One | |
| 2 | L-2₹11.0 L+₹2.3 L (26.0%)Rejected-Finance | L-2 | Rejected-Finance High rate quoted | |
| 3 | L-3₹13.1 L+₹4.4 L (50.6%)Rejected-Finance DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 176001 | L-3 | Rejected-Finance High rate quoted | |
| 4 | Rejected-Technical | - | Rejected-Technical Not fullfil as per NIT conditions | |
| 5 | Rejected-Technical V P O JAWALAMUKHI TEHSIL JAWALAMUKHI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 176001 | - | Rejected-Technical Not fullfil as per NIT conditions |
Tender Value
₹13.5 L
EMD Value
₹26,990
Closing Date
8 Feb 2023, 11:00 amClosed
EXECUTIVE ENGINEER
JAL SHAKTI DIVISION PALAMPUR
Survey, Investigation and preparation of Detailed Project Report
2023_HPIPH_67887_1
HP IPH- 14573-14610 DATED 01.02.2023
Open Tender
Survey
Item Rate
90 days
PALAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
EXECUTIVE ENGINEER
₹26,990
Yes
27 Apr 2024
1 Feb 2023
8 Feb 2023
1 Feb 2023
8 Feb 2023
1 Feb 2023
Amount
Preparation of Detailed Project Report (DPR) for Providing Sewerage System to Dadh and its adjoining area (Dadh and Dadh Jhikla) in Block Bhawarna in Tehsil Palampur, Distt. Kangra (H.P.), with using advanced survey technology including Differential Global Positioning System (DGPS)/ Total Station with precession limit of 0.5 cm for preparation of Site Plan, Marking of Proposal, Preparation of L-section and X-section as required, for site condition in complete form. Sewer network should be designed based on latest software like SewerCad and L-Section of sewer network should be provided along with profile. Reconnaissance survey should be conducted for preparation of contour plan in digital form with contouring interval of 1.00 meter showing features such as houses, HT lines, roads and any other required major benchmarks. There are 1 number of proposed sewage treatment plant of capacity (Approximate) 0.80 MLD and Intermittent pumping stations (if required) at different locations. STP with capacity 0.80 MLD should be designed based on integrated technology (MBBR +Root zone Technology) with latest effluent norms of Biochemical Oxygen Demand less than 10ppm. The detailed project report should contain complete proposal with detailed design of sewer network and STP along with all components. DPR should contain the drawing, details of measurements and abstract of cost of all STP components, including Inlet Chamber, Screen Chamber, Grit Channel, Distribution Box, MBBR, Sludge Drying Beds, Constructed Wetland (Rootzone System) with Kt value not greater than 0.26d-1, gravity based Multi Media Filter, Chlorine Contact Tank, Fencing Panels around the S.T.P Yard, Steel Gate, Interconnecting Path, Railing and Access Ladder, Plant Building/Chowkidhar Room, manhole chamber, inspection chamber, Flushing Tanks, PWD road damage, Panchayat footpath damage, etc. Drawings shall be prepared with AUTOCADD and nicely binded 04 (Four) copies of set of drawings shall be in hard & in soft format; complete in all respect as per directions of Engineer-in-charge.
Reconnaissance Survey, geo-tagging & Geodetic Survey on different scales & preparation of Topographical Maps in requisite scale to supply them both in soft & hard format including cost of Manpower, labour, surveying equipment’s, Camp equipment’s, transportation etc. for Providing Sewerage System to Dadh and its adjoining area (Dadh and Dadh Jhikla) in Block Bhawarna in Tehsil Palampur District Kangra (H.P.) in all kind of Terrain (as defined in scope of work) complete as per directions of Engineer-in Charge.
Preparation of Detailed Project Report for Detailed Project Report (DPR) for Providing Sewerage System to Dadh and its adjoining area (Dadh and Dadh Jhikla) in Block Bhawarna in Tehsil Palampur District Kangra (H.P.) with latest technology as per the wastewater characteristics of medical college, evolving design & drawing of the complete system including civil structures, pumping machinery etc. as per the guidelines, technical planning consideration, design norms and supplying four sets of nicely bind D.P.R (Hard copy & one no. soft copy) (as defined scope of work) complete as per the direction of Engineer -in- Charge.
HimTop Construction
Sanjay Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .