GARRISON ENGINEER AIR FORCE THANJAVUR
GARRISON ENGINEER (AIR FORCE), AIR FORCE STATION, PUDUKKOTTAI ROAD THANJAVUR
COMPREHENSIVE MAINT REPAIR TO LIFT AND FIRE ALARM SERVICES WITH CONNECTED WORKS AT AFS THANJAVUR
2020_MES_329798_1
8767/E8
Open Tender
Electrical Maintenance Service
Item Rate
330 days
THANJAVUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIR FORCE THANJAVUR
₹30,000
Yes
8 Apr 2020
28 Feb 2020
30 Mar 2020
28 Feb 2020
27 Mar 2020
13 Mar 2020
Amount
Supply and fixing existing lift 8-10 passenger battery 12 Volts, 7 AH complete including taking down of unserviceable item all as specified and directed.
Supply and fixing existing lift 8-10 passenger cabin light 18 watt 230 volts complete including taking down of unserviceable item all as specified and directed.
Supply and fixing run relay 24 volt DC complete including taking down of unserviceable item all as specified and directed.
Supply and fixing MCB Tripper safety 430 Volts complete including taking down of unserviceable item all as specified and directed.
Supply and fixing Safety relay 110 volts DC supply complete including taking down of unserviceable itemall as specified and directed.
Supply and fixing open close relay 110 volts DC 12 Volt complete including taking down of unserviceable itemall as specified and directed.
Supply and fixing siren 12 volts complete including taking down of unserviceable item all as specified and directed.
Supply and fixing Main limit switch 110 volts DC complete including taking down of unserviceable item all as specified and directed.
Supply and fixing switching mode power supply Board 230 volts input 24 volt output complete including taking down of unserviceable item all as specified and directed.
Supply and fixing switching mode power supply board 230 volts input 12 volts output complete including taking down of unserviceable item all as specified and directed.
Supply and fixing Tripper M1 to M9 (safety device relay) complete including taking down of unserviceable item all as specified and directed.
Supply and fixing door close limit card 12 volts complete including taking down of unserviceable item all as specified and directed.
Supply and fixing Lift rope complete including taking down of unserviceable item all as specified and directed.
Supply and fixing motor contact 110 volts DC complete including taking down of unserviceable itemall as specified and directed.
Supply and fixing final slowing relay Contact 110 volts DC complete including taking down of unserviceable itemall as specified and directed.
Comphrensive maintenance and repairs including attending break down complaints for the following electric fire smoke alarm system, electrically operated with 8 to 10 zone micro processor based fire alarm panel with LCD Display zone, short, open indication all as specified and directed. Note :- (i) The rate quted by the contractor shall include the rate for replacement of any electrical and electronic parts like PCB, battery charger, integrated circuits, diods, capacitors transformer, LED indicators, open / short circuit LEDs, relays etc. (ii) The rate quoted by the contractor shall include the rate for removing of short circuit / open circuit / earth faults for individual fire alarm panel. (iii) For testing by through authorised service engineer/dealers. (iv) The duration of the test is once in every month througout currency of contract. (v) Periodical test report to be submitted through authorised service engineer/dealers for every month (vi) Report of monthly inspection maintenance carried out by the contractor to be submitted on every inspection / maintenance and after rectification of any breakdown. (vi) Contractor is lailable for conducting inspection/maintenance/repair on call basis if required other than normal monthly inspection. On call contractor is required to attend the complaint within 24 hrs. If not attended the complaint within 24 hrs contractor is liable to pay a penality Rs 1500/- per day. (vii) Replacement of major spare parts as given in item here-in-after will be measured and paid separetely.
SRE tech building
SRE Adm building
Signal complex/AF Net
Station armory
UAV hanger bldg
Supply and fixing existing fire smoke alaram system battery 12V 7 AH dry type including taking down of unserviceable item. Make : Ravel
Supply, Installation of PVC armored copper conductor with double sitting FRLS cable size 4 sq. mm x 2 core with required all accessories including taking down.
Supply, Installation of PVC armored copper conductorwith double sitting FRLS cable size 1.5 x 2 core withrequired all accessories including taking down.
Material and labour for sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. Make:- Plaza / Havells / Polycab / FINOLEX.
Material and labour for sub main wiring with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 1.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. Make:- Plaza / Havells / Polycab / FINOLEX.
Material and labour Fire detectors complying with and type certified to EN - 45 addressible type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence as per IS:11360 including taking out old complete all as specified and as directed.
Material and labour 6 watt wall mounted CD speaker including taking out old complete all as specified and as directed.
Material and labour 10 watt wall mounted CD speaker including taking out old complete all as specified and as directed.
Supply and fix in replacement pluggable catridge type surge protection divice (SPD) TP+N high discharge current Imax 50 KA (L-N) 70 KA (N-E) voltage protection level 1.5 KV complete all as specified and as directed. Make : Havells cat part No - DHSAARBC50320 or equivalent in L&T/Havells complete all as specified and as directed.
Supply and fix in replacement pluggable catridge type surge protection divice (SPD) SP+N high discharge current Imax 50 KA (L-N) 70 KA (N-E) voltage protection level 1.5 KV complete all as specified and as directed. Make : Havells cat part No - DHSAARBC50320 or equivalent in L&T/Havells complete all as specified and as directed.
Supply and fixing Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators after and including taking down old DB with MCB complete all as specified and directed. Make : Legrand cat No 607710 or equivalent & approved model of SIEMENS/ MERLIN GERIN.
Supply and fixing Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators after and including taking down old DB with MCB complete all as specified and as directed. Make : Legrand cat No 607711 or equivalent & approved model of SIEMENS/ MERLIN GERIN.
Supply and fixing MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed. Make : Legrand Cat No 408609 to 408617 or equivalent & approved model of SIEMENS/ MERLIN GERIN.
Supply and fixing MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified and as directed. Make : Legrand Cat No 408683 or equivalent & approved model of SIEMENS/ MERLIN GERIN.
SHAPEMAKER
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .