Loading…
Loading…
Tender Value
₹10.3 L
EMD Value
₹10,500
Closing Date
9 Oct 2026, 4:00 pm
Executive Engineer, Electric (R&B) Division, Rajkot
A&A to Submersible Motor , Indoor and Outdoor Light Fittings and AC Machine in ITI Gondal , Taluka: Gondal , Dist: Rajkot.
348755
08 of 2026-27
Open
Electrical Works
Works
Rajkot
7 documents required · 7 mandatory
₹900
Executive Engineer, Electric (R&B) Division, Rajkot.
₹10,500
24 Sept 2026
24 Sept 2026
24 Sept 2026
9 Oct 2026
24 Sept 2026
Name of work: A&A to Submersible Motor , Indoor and Outdoor Light Fittings and AC Machine in ITI Gondal , Taluka:
Gondal , Dist: Rajkot.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
S.I.T.C. submersible pump set suitable for bore of 150 mm dia
or more having 3 phase motor capacity not less than 10 HP
1 1 Ea with following capacity. Lifting and Lowering taken extra. [C] 54063.28
25 stage 160 to 100 LPM discharge at 185 to 220 mtr head for
50 mm dia delivery pipe Cat.III
S.I.T.C. submersible pump set suitable for bore of 150 mm. dia.
or more having three phase motor capacity not more than
H.P. with following capacity . Lifting and Lowering taken
extra.(A) (12 stage) 280 to 240 LPM discharge at 90 to
mtrs. head respectively suitable for 50mm dia. delivery pipe
Lowering of submersible motor pump set at the depth of
following ,complete with required. Nos. and size of casing
pipes erected by means of proper chain pulley block & pipe
3 2 Per Job 2996.67
wrenches after checking of threads of each pipe with coupling
to take the load of the pump set and pipe assembly filled up
with water (C)Above 120 mtr.
Providing and erecting ISI marked PVC insulated PVC
4 600 Mtr. Sheathed Flat flexible Submersible copper cable approved 172.71
make of following Size. (D) 3 Core x 6 Sq. mm.
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity
(b)40 Amp. Cat.III
Supplying & erecting approved make 3 phase motor control
cubical panel ( Star - Delta) made from16 G. CRCA sheet duly
painted with epoxy powder painted inside and outside with
hinged doors and locking arrangement, consisting of suitable
size of ON- OFF isolator (AC - 3/23 duty) main fuses, single
phasing preventer cum water level. Guard (Complete unit),
Toggle switch to by pass Single phase preventer cum WLG,
indicating lamps for R- Y- B phases, over load relay,
6 1 Ea Automatic water level controller, Ammeter & Voltmeter each 13605.71
with two way selector switch incoming wires duly socket
Crimped, Panel to be erected on angle iron frame grouted on
wall as directed. Star Delta & main contactor, overload relay,
thermal / Electronic Star delta cutoff timer, start - stop push
buttons. The isolator overload relay & contactors of L& T,
Siemens or Cuttler Hamer make only. Panel to be erected on
angle iron frame ground on wall. (B) S/D up to 10 H.P.
Supplying & erecting approved make motor control cubical
panel (Direct - on - line) made from 16 G. CRCA sheet duly
epoxy powder painted inside and outside with hinged doors
and locking, arrangement consisting of suitable size of ON-
OFF isolator (AC - 3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y - B phases, overload relay,
7 1 Ea Automatic water level controller, Ammeter, Voltmeter each 8710.24
with two way selector switch incoming, wires duly socket
crimped, main contactor & overload relay, start - stop push
buttons, to be erected on angle iron frame grouted on wall as
directed. The isolator, overload relay & contactors will be of L
& T, Siemens or BCH make only. (B) DOL for 7.5 H.P.
Supply of following size of TOP & BOTTOM accessories i.e.
Adaptor set (CI) long, pump guard set, starter pipe Rubber ring
8 2 Ea for submersible pump & UPVC column pipe as directed by 1489.75
Engineer - in - charge with necessary plumbing as desired. [D]
Providing & laying approved make ISI marked HDPE 6Kg /
cm2 (Class-3) as per IS:4984:1995 PE-80 to be erected at
9 400 Mtr. road crossing on or floor as directed for laying of cable. The 163.62
pipes as following size of dia & weight per 6 mtr.(B) 50 mm
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Replacing Old & u/s by Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name
10 160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount
46 Ea Downlight with provision for spring loaded mounting clips 589.84
complete.IP20 (iii) 16-20 watts, Surge-2 KV Cat-lll
(A) Square/ Circular shaped Surface/Recessed Mount
30 Ea Downlight with provision for spring loaded mounting clips 758.51
complete.IP20 (iv) 22-24 watts, Surge-2 KV Cat-lll
Replacing Old & u/s by Supplying and erecting LED street
light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
11 company mark/name engraved or embossed 160 to 270
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required
LM-79 & LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between
the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and
25 Ea ,Light must have 440VAC line supply with over-voltage 6177.16
protection. (iv) 90 - 119 watts Cat-lll
Providing & erecting Switch board for Computer or electric
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white
front plate,modules erected with necessary connections as
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected concealed in /flushed on
13 110 Mtr. wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC 78.78
insulated stranded wire of green colour for earth continuity of
following size (A) With medium class Rigid PVC pipe and
accessories (a) 2 wire 1.5 sq. mm
(A) With medium class Rigid PVC pipe and accessories (b)
wire 2.5 sq. mm
Providing following type of Modular Type Accessories
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
modules erected with necessary connections as per site
situation directed by Engineer In charge.(8) Computer RJ-45
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall or
15 100 Mtr. ceiling erected with necessary PVC fittings & Junction boxes 33.33
fixed with adhesive solution & Clamps with following dia of
pipes, in approved manner as directed (b) 25 mm
Supplying & erecting approved make LAN cable of following
size in existing pipe as per direction [C] CAT -
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
cable multistrand / Solid Aluminium conductor for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (B) 4 core 6 Sq. mm
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Replacing Old & u/s by Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size
of cables (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core)
Making trench in soft soil of suitable width of 90 cm deep for
laying cable or locating the fault all over the run and back
filling the same and making the surface as normal ground.
Making trench in Hard Murrum / Tar Road of suitable width of
90 cm or required depth for laying any size of cable or locating
20 125.0 Mtr. the fault all over the run and back filling the same and making 432.28
the surface as normal ground.(B) If additional machinery like
hammer driller or JCB use [Add]
Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia
providing and erecting Mains with ISI marked, 1.5KV grade
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
22 8 Mtr. erected in existing pipe of following size (Specifically for 115.14
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required.(f) One wire 10.00 sq. mm
Providing and erecting Inverter based approved make split air-
conditioning unit consisting of condensing unit with variable
speed fan motor, inverter type hermetically sealed rotary
compressor with accessories etc. duly connected separately
erected evaporating unit and blower motor with its accessories
23 3 Ea by means of extra supplied proper insulated copper 56833.71
tubing,drain PVC pipes suitable for ( cost includes Eco
Friendly green gas charging and 15A plug top & Remote
Control & MS Stand) with necessary core cutting.(1)For
ISEER Range (KWH/KWH)(3.1 to 3.99) (C) for 1.7 to 2 ton
Supplying and erecting insulated pair of soft copper tubing
open or concealed including power and control cable,necessary
PVC drain pipes for Split AC machine up to 4 TR capacity
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch
& 5 pin Plug erected on PVC / Metallic/Wooden box covered
with appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of
accessories.[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board.(a) with medium class
Rigid PVC pipe and accessories erected flushed on wall/ceiling
complete (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Supplying and erecting Flexible PVC insulated multi strand
multi core 1.1 kV grade ISI marked copper wires of following
size to be erected as directed.(c) 1.00 Sq.mm 2 core round/ flat
Providing & erecting 240 V MCB double pole switch for
lighting Load (B Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity
(A) 6 to 32 Amp. Cat.III
Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
complete with proper insulation without leakage and earthing.
Supplying and erecting wall mount speaker with rated power of
30 watt/power tapping 30/15/7.5 watt available,opening angle
180 degree H * 77 degree V ,sound pressure level 88 dB
,frequency response of 70Hz to 20KHz [[Approved by
Competent Authority i.e. not Below the rank of Executive
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Providing and erecting cordless microphone with UHF
Diversity handheld wireless microphone/caller wireless
complete with receiver and transmitter unit,Cardiod ,polar
pattern,dynamic microphone,LCD display for battery and
frequency status and information ,32 preset channels,with
30 3 Ea compatible groups of 8 channels,14 hrs.battery life,frequency 6163.02
response 80Hz to 18KHz.,RF sensitivity <1.0 Uv,image
rejection > 55 dB,dynamic range >95 dB and receiver having
32 channels,S/N ratio>100 dBA,Dynamic range>95
dB,distortion<1% [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Supplying & erecting Amplifier having following specification:
Power Output :100 W (RMS):(130 W Max.)
inputs :5 Mics & 2 Aux.
frequency Response :50-15000 Hz+3db
Tone Controls :Cut & Boost type
Speaker Matching :4-8-ohms 70- 100 V line
31 2 Ea LED Meter :5 LED Array. 7500.26
The amplifier suitable to operate 240V A.C.& 24 volt D.C.
(Battery) with automatic changeover from AC to Battery
operation, duly protected by wrong Battery Polarity
connection. [[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
Supplying & erecting approved make Digital time switch
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts
32 2 Ea Minimum switching setup time 1 minimum & LCD display. 3168.37
Also comprised permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary
connection erected as directed.
Supplying & erecting power contactor ,AC3 duty for time
33 2 Ea switch complete erected as per direction Cat III (D) 4 pole 2782.55
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
SITC of EXTENSION CABLE ASSEMBLY - 2MTRS
34 3 Ea [Approved by Competent Authority i.e. not Below the rank of 1059.49
Executive Engineer ]
Note:- The Credit of dismentalled materials for Rs.4523.00 shall be recovered from the First R.A. bill payable to the contrator and
there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount of
my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation
regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other
tender documents of this work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of
Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote
the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-in-
Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the
agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) DBD.pdf
SCH-B (1).pdf
ANNEXURE-A (1) (1).pdf
DM.pdf
SCH-A (1).pdf
MAKE FOR ELECTRICAL ITEM(upadatemake list).pdf
SBD.docx
DOCX
EMD GR.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .