| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.9 LAccepted-AOC | L1 | Accepted-AOC Bidder is L1 |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
8 Nov 2023, 6:00 pmClosed
Superintending Engineer IIT Mandi
Superintending Engineer IIT Mandi HP
Day to day repair and maintenance works for buildings at South and North campuses of IIT Mandi for the period of Nov. 2023 to March, 2024
2023_IITMD_778970_1
IIT Mandi (CW)/SE-1458/2023-24/145-147 dt.01-11-23
Open Tender
Civil Works
Item Rate
150 days
North and South Campus of IIT Mandi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹2.1 L
25 Jan 2024
2 Nov 2023
10 Nov 2023
2 Nov 2023
8 Nov 2023
2 Nov 2023
2 Nov 2023 - 7 Nov 2023
Amount
Plaster repair to damaged plaster surface after making necessary chipping, cleaning the surface and plastering with CM 1:4 (1 Cement : 4 Coarse sand ) of 20mm thick at all level. The surface will be painted after necessary repair works to match the existing finish such as OBD /Plastic emulsion/ Water proof cement paint (As per existing surface) after suitable surface preparation using putty, primer etc complete. The necessary scaffolding, curing etc shall be arranged by the contractor. No additional payment will be made for scaffolding, curing etc complete. Upto 1 Sq.m
Arresting seepage of water from wall surface, from the junction of chujjas, weather shade, cantilever ends, corbels and wall at sill level of windows, jambs of windows etc complete including necessary Grouting, grooving, applying sealant to the openings near Door/window frames plastering, painting etc complete including charges for necessary water proofing sealant 10mm to 20mm depth in concrete slab by power cutter and fixing the SBS membrane in the groove by using sona elastic sealant or thioflex 600 gun grade as per the direction of the Engineer in charge.
Renewing glass panes in wooden, steel and aluminum windows/ doors/ ventilators with necessary PVC Neo prine gaskets or wooden fillets / beading or fixing putty for steel windows or matching with existing joineries - Glass panes weighing 13.75 Kg / Sqm (5.5 mm thick) - Area 0.1 Sqm to 0.5 Sqm.
Renewing glass panes in wooden, steel and aluminum windows/ doors/ ventilators with necessary PVC Neo prine gaskets or wooden fillets / beading or fixing putty for steel windows or matching with existing joineries - Glass panes weighing 13.75 Kg / Sqm (5.5 mm thick) - Area 0.5 Sqm to 1.5 Sqm.
Easing of windows / doors for smooth operation including removal and refixing if required after planning the edges etc, necessary painting of the planned surface with matching paint over a coat of primer, necessary hinges, screws etc complete. (rate for one shutter)
Removal and replacing SS / Aluminum powder coated door fittings such as damaged tower bolts (upto a size of 300x10mm), handle (75mm to 125 mm), Hinges (Upto a 125x75x 4mm ) hook and eye, catch, cupboard locks upto 75mm etc., complete of various sizes and material using necessary screws. The material like tower bolt, necessary screws have to be arranged by the contractor (the sizes indicated for fittings are maximum). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Removal and replacing SS / Aluminum powder coated door fittings such as damaged sliding door bolts (Aldrop) upto a size of (300 x 16mm) etc complete of various sizes and material using necessary screws. The material like sliding door bolts, necessary screw have to be arranged by the contractor (the sizes indicated for fittings are maximum). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Repairing the aluminum/glazzed doors, windows and ventilators including charges for replacing damaged sections, pivots, hinges, tower bolts, door stopper, handles, rubber beading, aluminum clips, PVC/ Neoprene felts hooks and eyes, CP brass / SS screws, aluminum snap beading for glazing/ paneling etc complete including charges for lubricating the same after repairs works. (No material will be issued by IITM) Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the Floor spring: Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings. Replacing the damaged / unserviceable floor spring with new including charges for labour for fixing in Aluminum/Glass Door and all other material required etc complete.
Repairs to Vertical Blinds: Repairs to vertical blinds with 100 / 89 mm wide imported superior polyester base fabric vanes with Scotch guard application including replacement of damaged blind. Repairs to head rail of extrude anodized high strength aluminum alloy of size 25mmx 50mm high or equivalent with wall thickness of 1.2mm. This item includes repair / replacement of end control units consist of reduction gearbox having the reduction ratio of 3.5:1 for a very smooth operation of the blind if needed. This repairs work includes repairs to planetary gear in the outer housing, four small transmission gears fitted in the middle assembly and a end receiving gear attached to central sprocket Unit, Tilter chain is made of 4.5mm plastic beads moulded on 2.2mm thick polyester card if needed, pitch of the beads is 6mm , end control unit has the facility to rotate the louver by 180 degrees, Tilt rod is made of extruded aluminum having 3 keyways and the average dia shall be 5.8 mm carrier (Runner) is made of moulded plastic. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing of damaged Novopan Boards of all types: Replacing the damaged / decayed novopan / Ply wood of thickness up to 18mm for doors and partitions, furniture’s including cost of material such as fevicol, nails, screws etc complete. For the ply wood work surface shall be made to match with existing surface finish such as mica of 1mm thick or enamel paint - upto 1.5 Sq.m. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing of damaged Novopan Boards of all types: Replacing the damaged / decayed novopan / Ply wood of thickness up to 18mm for doors and partitions, furniture’s including cost of material such as fevicol, nails, screws etc complete. For the ply wood work surface shall be made to match with existing surface finish such as mica of 1mm thick or enamel paint - Upto 1.5 to 2.5 Sq.m Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing CP towel rail of size 20x600mm long Jauqar, Cera, Hindware Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing special quality bright finished brass cupboards locks. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing wood work in frames of doors, windows, clerestory windows for second class teak wood.
Providing and Fixing 19mm thick waterproof decorative type board for cupboard shutters door and in modular kitched with necessary teak wood beading, screws, nails etc as per direction of Engineer in charge. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing Aluminum Tower bolt ISI marked anodised (anodic coating not less than Grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc., complete: 200x10mm. (JAL / CLASSIC / CROWN). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing Aluminum Handles ISI marked anodised (anodic coating not less than Grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc., complete: 125mm. (JAL / CLASSIC / CROWN). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing Aluminum Handles ISI marked anodised (anodic coating not less than Grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc., complete: 150mm. (JAL / CLASSIC / CROWN). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing door bottom with pauddak / kongu country wood frame of size: 25x40mm. Up to 1.05m length for Threshold etc
Providing and Fixing Aluminum sliding door bolts ISI marked anodised (anodic coating not less than Grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc., complete: 250x16mm. (JAL / CLASSIC / CROWN) Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing of 4 levers mortice lock of (Godrej) including removing the existing lock and etc. complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Labour charge for repairing the existing wooden door / window frame shutters including repairs to the existing frames / shutters after removing from the original position and refixing the same after repairing. . The rate inclusive of cost of wooden pieces, screws etc but excluding cost of fittings. The rate shall be applicable to area of opening up to 3.00sqm. The Payment will be made for each shutter of door / window.
Providing and Fixing nickel plated S.S. pipe curtain rods with nickel plated brackets:25mm dia (heavy type).
Providing and Fixing Stainless steel butt hinges with stainless steel screws etc., complete as per IS:12817 : 150x65x1.90mm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing stainless steel butt hinges with stainless steel screws etc., complete as per IS:12817: 100x58x1.90mm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing bright finished brass tower bolts(barrel type) with necessary screws etc., complete: 100x10mm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing bright finished brass hanging type floor door stopper with necessary screws etc., complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing ISI marked flush door shutters conforming to IS:2202(Part I) decorative type,core of block board construction with frame of Ist class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Extra for Providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters- 30mm to 40mm thick (over all area of door shutter to be measured)
Extra for Providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded ) ( over all area of door shutter to be measured): Rectangular or square
Providing and Fixing wooden moulded beading to door and window frames with iron screws,plugs and priming coat on unexposed surface etc.,complete: 2nd class teak wood- 50x12mm.
Providing and Fixing SS Casement stays (straight peg type) with necessary screws etc., complete: 300mm weighing not less than 200gms. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and Fixing SS Casement stays (straight peg type) with necessary screws etc., complete: 200mm weighing not less than 120gms. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade one or more coats (Asian/Dulux) - upto 2.5 Sqm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade one or more coats (Asian/Dulux) - More than 2.5 Sqm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Varnishing on wood work of approved brand and manufacture of required to give an even shade one or more coats (Asian/Dulux). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing fly proof galvanized SS wire mesh to windows, ventilators and doors using galvanized MS wire gauge with average width of aperture 0.67mm in both directions including country wood beading of size 30x12mm., painting etc., complete as per the direction of Engineer in-charge.
Repairs to false ceiling mineral false ceiling/calcium silicate/ Gypsum/matel false ceilling. The rate inclusive of labour and material for painting gypsum false ceiling, changing grids in mineral false ceiling/calcium silicate/ Gypsum/matel false ceilling etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing drawers Telescopic chennel with new one, the rate inclusive of labour and material. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of Pivots (Top & Bottom) to Aluminum/glazzed doors by removing the door including fixing with necessary screws etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of "U" rubber for aluminum doors including necessary screws and fittings etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of Aluminum beading in glazed portion in aluminum doors including removing the existing beading with necessary screws and fittings etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of glass beading in glazed portion in Aluminum doors including removing the existing beading with necessary screws & fittings etc complete
Removing and refixing of Aluminum windows including servicing the damaged fixing and re-fixing the same etc complete.
Supplying and fixing of Aluminum door closers, necessary screws etc complete Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of Floor spring Hardwyn or equaling make ( Heavy duty) including fixing to Aluminum doors and glass door etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of PVC gasket including fixing to sliding Aluminum windows etc complete.
Supplying and fixing of tougned glass 5/8mm thick for glazed portion in upvc doors and windows including removing the damaged section with necessary fittings etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Alteration for Aluminum doors including removing of damaged channels, Supplying and fixing of Aluminum doors including the existing damaged with necessary screws & fittings etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing glazing in aluminum door, windows, ventilator shutters and partitions etc,. With PVC/Neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (cost of aluminum snap beading shall be paid in basic item) with glass panes of 5.5mm thickness (Weight not less than 13.75Kg/Smq) (MODIFLOAT) Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing 12mm thick Particle board of both side Ivory Novapan make for aluminum door including necessary screws and lobour etc,. all complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Hiring of JCB/Excavator for all types of excavation,levelling,dressing work etc. complete as per entire satisfaction and direction of engineer in charger.
Hiring of Tipper/dumper for removal/shifting of constructuion material,waste disposal etc. complete as per entire satisfaction and direction of engineer in charger.
Hiring of Tractor for removal/shifting of constructuion material,waste disposal etc. complete as per entire satisfaction and direction of engineer in charger.
Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Old work (One or more coat applied @ 0.90 ltr/10 sqm) (Asian/Dulux) Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Finishing walls with Acrylic Smooth exterior paint of required shade:Old work (One or more coat applied @ 0.90 ltr/10 sqm).(Asian/Dulux) Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns
Centering and shuttering including strutting, propping etc. and removal of form work for :Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Drain Block: Charges for Removal of blockage in gully trap, floor trap, WC using appliances like rubber plunger, steel rods etc complete without any damage to the fittings, including flushing the trap etc after cleaning and removal and disposal of cleaned material at suitable place out side the campus or place pointed out by Engineer incharge. Kitchen & Bath room Nahini trap / floor sump / bottle trap.
Drain Block: Charges for Removal of blockage gully trap, floor trap, WC using appliances like rubber plunger, steel rods etc complete without any damage to the fittings, including flushing the trap etc after cleaning and removal and disposal of cleaned material at suitable place out side the campus or place pointed out by Engineer incharge. IWC / EWC Blockage.
Drain Block: Charges for Removal of blockage gully trap, floor trap, WC using appliances like rubber plunger, steel rods etc complete without any damage to the fittings, including flushing the trap etc after cleaning and removal and disposal of cleaned material at suitable place out side the campus or place pointed out by Engineer incharge. Out side gully.
Drain Block: Charges for Removal of blockage gully trap, floor trap, WC using appliances like rubber plunger, steel rods etc complete without any damage to the fittings, including flushing the trap etc after cleaning and removal and disposal of cleaned material at suitable place out side the campus or place pointed out by Engineer incharge. Inspection chamber.
Providing and fixing Square-mouth S.W gully trap "A" complete with C.I grating brick masonry champer with water tight C.I cover with frame of 300 x 300mm size (inside) the weight of cover ta be not less than 2.70 kg as per standard design: 150 x 100mm size P type - with fly ash concrete bricks class 100 conforming to IS: 4885. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing Square-mouth S.W gully trap "A" complete with C.I grating brick masonry champer with water tight C.I cover with frame of 300 x 300mm size (inside) the weight of cover ta be not less than 2.70 kg as per standard design: 200x100mm size P type - with fly ash concrete bricks class 100 conforming to IS: 4885. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Constructing masonry champer 90x90x100 Cm, inside with 100 class designation brick work with in cement mortar 1:4 (1 cement : 4 coarse sand ) SFRC Cover excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand )12mm thick finished with a floating coat of neat cement complete as per standard design with fly ash concrete bricks. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Constructing masonry champer 60 x 60x50 Cm, inside with 100 class designation brick work with in cement mortar 1:4 (1 cement : 4 coarse sand ) SFRC Cover excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand )12mm thick finished with a floating coat of neat cement complete as per standard design with fly ash concrete bricks.
No water: charges for removal of blockages in water supply line (including release of air lock) by removing and refixing the pipe line to the required length, cleaning the pipes using the steel wire brush etc complete and ensuring free flow of water-over roof, in bath room, WC, wall surface, kitchen etc, (Any pipe pieces, fittings etc required shall be paid for separately). This item shall be operated only when the work requires removal of the existing pipe and re-fixing the same. Non availability of water due to other cause like empty tank will not be paid under this. To be operated whenever replacement of parts are required. Pipe removal of pipe up to 6m. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Flush not working: charges for Restoring the flushing cistern in toilets to working condition including removal, cleaning and re-fixing the internal parts/units etc complete. (Fittings for replacement of required will not be paid separately). The rate is including replacement of internal fittings. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the existing flushing cistern new PVC/CI cistern (concealed and open type) of capacity 3/6,10 liters in toilets including cost of material, fixing of brackets etc wherever needed complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Tap fault: charges for stopping leakage in stop cocks (concealed and open type), bib cocks, brass tap, angle valve, pillar tap, mixers etc including replacement of washers etc complete. The rate shall include the cost of washer. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing with new CP brass stop cocks (Concealed) / stop cock open type including the cost of material, thread, white metal putty etc complete. (15/20mm dia) Stop cock (Concealed / open). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing with new wall mixer with CP brass materials including cost of thread, white metal putty etc complete. (15 / 20mm dia). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing with new CP brass bib cocks, angle valve, pillar tap including cost of material, thread, white metal putty etc complete. (15/20mm dia) Bib Cock / Pillar tap/ Angle Valve. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing with new CP brass swan neck pillar cock, including cost of material, thread, white metal putty etc complete. (15/20mm dia). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Pipe leakage: charges for stopping the leakage in the water supply pipe lines of all dia provided internal work (Exposed pipe line) including removal, rethreading and refixing of the pipe line (Pipes, elbows, unions, reducers, nipple etc required shall be procured by contractor) including necessary scaffolding: pipe dia 15mm to 50mm (Leaking of water should be arrested at the same day of complaint). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Pipe leakage: charges for stopping the leakages in the water supply pipe lines of GI/Aluminium composite /PVC pipes of all dia (15mm to 25mm ) internal work. (concealed in walls) including removal, rethreading and refixing of the pipe line (PVC /GI/Aluminum composite pipe) to required length complete (Pipes, elbows, unions, reducers, nipple etc., required shall be procured by contractor). This work includes chipping the wall tiles or plastering in wall and restoring the wall surface to the original condition by refilling the chases with CC of 1:2 :4 using 6mm nominal size aggregate required pipe, fittings and matching wall tiles or matching with existing surface, cement sand coarse aggregate including necessary labour for masonry tile work etc shall be arranged by the contractor (Leaking of water should be arrested at the same day of complaint). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Change of W.C Seat cover: Providing and fixing seat cover for European type water closets including removal of existing seat cover etc complete (materials shall be procured by the contractor) white / Black. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Basin waste pipe broken: charges for replacing waste coupling / waste pipe in wash basin, kitchen sink , laboratory sink including removal of existing damaged waste coupling/ waste pipe, material like white lead, thread etc including cost of waste coupling and waste pipe etc complete. (32 or 40mm) waste coupling (32/40mm) waste pipes / Spring horse waste pipe (Rigid / Flexible). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete - Flexible pipe - 32mm dia. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Change of WC: charges for replacing the broken/defelctive water closet including necessary removal of flooring, removal of fill material cleaning the surface fixing the W/C and restoring the flooring to original condition along with necessary filling etc complete(Materials like WC pan, Trap, cement sand aggregate, flooring materials, flooring tile, applying water proofing compound etc should be arranged by te contractor. (white colour) Indian type WC (Orisa pattern) / Indian type including concrete and water proofing. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Change of WC: charges for replacing the broken/defelctive water closet including necessary removal of flooring, removal of fill material cleaning the surface, fixing the W/C and restoring the flooring to original condition along with necessary filling etc complete. (Materials like WC pan, Trap, Cement , sand aggregate, flooring material, flooring tile, applying water proofing compound etc should be arranged by the contractor) White colour) European type WC pan. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Change of urinal basin: charges for replacing the broken/defective urinals including necessary removal, fixing and restoring the fittings to original condition along with necessary fittings etc complete. (Materials like coupling, connection pipe etc should be arranged by the contractor) - White colour. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Leakage in Drain pipe: Dismantling C.I or asbestos or PVC rain water/ drain pipe upto 75mm dia with fittings and clamps including stacking the materials within 50m and replacing the same with PVC pipe of 4 kg Sqm 50 mm to 75mm dia pipe as per the direction of Engineer incharge. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Leakage in Drain pipe: Dismantling C.I or asbestos or PVC rain water/ drain pipe upto 110mm dia with fittings and clamps including stacking the materials within 50m and replacing the same with PVC pipe of 4 kg per Sqcm - 110 mm dia pipe. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Leakage in Drain pipe: Dismantling C.I or asbestos or PVC rain water/ drain pipe of dia above 110mm and upto 160mm dia with fittings and clamps including stacking the materials within 50m and replacing the same with PVC pipe of 4 kg per Sqcm - 160 mm dia pipe. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
PVC pipe- replacing the defective / broken fittings with wall face unplasticised -Rigid PVC rain water pipe fittings. 75mm bend with door / shoe/ cowl. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
PVC pipe replacing the defective / broken fittings with wall face unplasticised -Rigid PVC rain water pipe fittings. 110mm bend with door. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
PVC Pipe-Replacing the defective / broken fittings with wall face unplasticised - Rigid PVC rain water / drain pipe fittings.110mm Plain Elbow/Plain Tee. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing of CP brass wall mixer with necessary flange and etc complete as per direction of Engineer in Charge 20mm dia. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the faulty shower arm with new fittings. Charges including all material, labour etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the faulty shower rose with new fittings. Charges including all material, labour etc complete., Shower arm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Wall tiles repair / replacements of tiles provdided for dado / floor work in WC / bath room, kitchen etc using matching tiles of same quality, colour and shade with necessary removal of damged tiles etc complete. The tile may be pasted using cerabond or as per the direction of the engineer in chrage. Glazed tile - colour / white ceramic tiles - up to 1.5 sqm area. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Flooring repair: Repair to existing flooring after removal of damaged flooring, cutting the flooring to a regular shape, restoring the surface to original level, colour and shade using appropriate material. The work should be done strictly as per the CPWD specification of work for flooring. Cement concrete flooring of all thickness as per the specification. C.C flooring - Area up to 1.00 to 2.00. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Flooring repair: Repair to existing flooring after removal of damaged flooring, cutting the flooring to a regular shape, restoring the surface to original level, colour and shade using appropriate material. The work should be done strictly as per the CPWD specification of work for flooring. Cement concrete flooring of all thickness as per the specification. C.C flooring -Area above 2.00 to 3.00 sqm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the damaged floor trap with PVC Nahini floor trap of approved make and up to 150mm dia after necessary cutting the floor. Repairing the same etc complete including cost of all material complete. (The floors shall be restored to original finish). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the damaged floor trap with PVCMulti floor trap of approved make and up to 150mm dia after necessary cutting the floor. Repairing the same etc complete including cost of all material complete. (The floors shall be restored to original finish). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing wash basin (Oval type) with making good the walls etc complete. White Vitrous china oval wash basin 550mm excluding cost of fittings. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing damaged cudappa sink 20mm thickness - bowl of size 600x600x300mm and with necessary fittings , necessary waste / waste pipe, Brackets etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing mirror of required thickness and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing Reactangular shape 450mmx600mm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing brass gate valve With CI wheel of approved quality (Screw ended) leader or Harrison 15mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing gun metal gate valve with CI wheel of approved quality (Screw ended) - 20mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing gun metal gate valve with CI wheel of approved quality (Screw ended) - 25mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing gun metal gate valve with CI wheel of approved quality (Screw ended) - 32mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing gun metal gate valve with CI wheel of approved quality (Screw ended) - 40mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing gun metal gate valve with CI wheel of approved quality (Screw ended) - 50mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing C.P/PVC grating Prayag or equivalent (100 to 150mm). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Repairing the health faucet including the replacing of washer and compele defective fitting etc. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing of metro / equivalent health faucet of approved quality and make - 15mm dia. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing unplasticised PVC connection pipe with brass unions: 45cm length - 15mm nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing GI pipes complete with GI fittings and clamps including trenches and refilling etc, (External work) 32mm dia nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing GI pipes complete with GI fittings and clamps including trenches and refilling etc, (External work) 40mm dia nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing GI pipes complete with GI fittings and clamps including trenches and refilling etc, (External work) 50mm dia nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing GI pipes complete with GI fittings and clamps including trenches and refilling etc, (External work) 75mm dia nominal bore. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing, laying and joint welding of CPVC pipes 20mm dia (class 6kg/ Sqm) heavy duty with necessary fittings like reducer, bend, T-joints etc complete as per the directions of Engineer-in-charge.. The clamps to be fixed in the regular interval as required in the site condition. The rate inclusive of required labour, tools and tackles etc. complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing, laying and joint welding of CPVC pipes 25mm dia (class 6kg/ Sqm) heavy duty with necessary fittings like reducer, bend, T-joints etc complete as per the directions of Engineer-in-charge. The clamps to be fixed in the regular interval as required in the site condition. The rate inclusive of required labour, tools and tackles etc. complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing, laying and joint welding of CPVC pipes 32mm dia (class 6kg/ Sqm) heavy duty with necessary fittings like reducer, bend, T-joints etc complete as per the directions of Engineer-in-charge. The clamps to be fixed in the regular interval as required in the site condition. The rate inclusive of required labour, tools and tackles etc. complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing, laying and joint welding of CPVC pipes 40mm dia (class 6kg/ Sqm) heavy duty with necessary fittings like reducer, bend, T-joints etc complete as per the directions of Engineer-in-charge. The clamps to be fixed in the regular interval as required in the site condition. The rate inclusive of required labour, tools and tackles etc . complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing, laying and joint welding of CPVC pipes 50mm dia (class 6kg/ Sqm) heavy duty with necessary fittings like reducer, bend, T-joints etc complete as per the directions of Engineer-in-charge. The clamps to be fixed in the regular interval as required in the site condition. The rate inclusive of required labour, tools and tackles etc. complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing, laying and joint welding of CPVC pipes 75mm dia (class 6kg/ Sqm) heavy duty with necessary fittings like reducer, bend, T-joints etc complete as per the directions of Engineer-in-charge. The clamps to be fixed in the regular interval as required in the site condition. The rate inclusive of required labour, tools and tackles etc . complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing of CP Head for pillar cock, Bib cock and angle cock, etc complete., Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing spindles with washer to the pillar cock, Bib cock and long body tap, etc complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing of 20mm dia extension nipple with a length of 50 to 75mm with necessary fittings etc., complete as per direction of engineer in charge. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providng and fixing of CP Brass soap dish with CP Brass screws and etc, complete as per direction of Engineer in charge. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing CP spreader as per standard size and weight - urinal spreader. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Preparing surface and applying Brush Bond coatings mixed with cement and water proofing compound at the ratio of 0.5 Ltr / kg in each layers and applying for two different stages and etc complete as per direction of Engineer in charge. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40mm dia. M.S. tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc., and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. The lavational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. (This item will operated with the approval of the Executive Engineer and wherever absolute requirement for the safety of the work).
Labour charges for fixing of Geyser / lab equipment’s / washing machine connection including providing necessary clamps and screws, nails by using drilling machine for making holes and wooden plugs etc complete as the direction of Engineer In Charge.
Replacing damaged Kitchen sink with White Vitreous China laboratory / kitchen sink upto a size of 650x450x200mm with CI brackets, CP brass, chain with rubber plug, 40mm CP brass waste and 40mm CP brass trap with necessary CP brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Painting G.I Pipes and fitting with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for New work-50mm dia naminal bore
Providing and fixing PTMT 15mm dia Urinal Spreader size 95x69x100mm with 1/2" BSB thread and shapes, weinghing not less than 60grms etc. complete. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Exposed parts for MFV 1093 Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Spring for 1093 – DOCOL. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Adjusting lock plastic (P.No-13) MFV. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Special nut for body of metropole F valve. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the rate inclusive of labour, materials etc complete. Only plastic piston of Metropoloe FV OWN. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Extension piece for MFV 1093 spindle. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Circllip of piston for MFV 1093. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Spindle of piston of MFV 1093 DOCOL. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Stopper bush MFV. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Gland nut plastic Metro F.V. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Piston Housing Plastic for MFV. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. EXTN set MFV sleeve, spindle & spring. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Seal washer MFV. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. 1.5" long spindle with brass brush 1093. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Silicon grease 1/2 kg. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. 1.5" long sleeve for MFV 1093. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Flange for MFV 1093/1095. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. Plastic cap for spring of MFV. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. O ring MFV Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Replacing the fittings, the rate inclusive of labour, materials etc complete. O ring MFV. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing wall mounting flush tank parryware or equivalent with all fittings simon set. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing wall mounting closet of white colour ceramic with all fittings. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing toilet paper holder (CP). Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing CP towel ring. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing CP towel rod. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing CP bottle trap. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Supplying and fixing 75 & 110 mm Special clamp
Supplying and fixing 160 mm Special clamp
Supplying and fixing U clamp with horizontal support , bolt nut etc complete 300 to 400mm width support clamp
Supplying and fixing U clamp with horizontal support , bolt nut etc complete 600 mm width
Supplying and fixing water free urinal- manufactured. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe.
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
P/L for base preparation of cleaning, brushing and removal of any loose/flacky materials,in case of pot holes/cracks, the same shall be repaired with Polymer modified cement mortar using Latex. Grinding of tiles is a necessary to make the surface more abrasive and goodfor adhesion. Covings shall be made at all junctions75mmX75mm.Geotextile of 120 GSM shall be applied on all covings and smart care ultron shall be applied over it. (ii) Providing and applying smart care Ultron liquid applied hybrid Polyurethane polyuurea based, two component, llow VOC, elastomeric, seamless, waterproof coating bearing the following properties: Mixing ratio by weight 11 Kg :9 Kg [Base:Hardener] Elongation at break at 1.2 mm in 500 ± 50% ASTM D 2370 Tensile Strength at 1.2 mm Min 9 MPa ASTM D 2370Puncture resistance at 1.2 mm250±20 N ASTM E 154 Hardness (Shore D scale) Min 35 units ASTM D 2240 Pull Of Adhesion (Concrete surface failure) Min 1.5 MPa ASTM D 4541.Pot Life at 25 Deg C and 50% Relative Humidity 30 minutes Solid content>85% ASTM D 1644Water impermeability on coated concrete at 10 bar for 72 hours No Leakage BS EN 12390-8 (Resistance to Hydrostatic head > 100m) Application Temperature 10 - 40 deg C Overcoating interval time 12-16 Hrs Light Pedestrian traffic time 24 Hrs, however final curing time conditions 30 deg C, 55% RH 14 days Crack bridging Min 4 mm ASNZ 4548 (iii) Applying a 5 to 10 mm coat of microconcrete on theUltron surface so that it can be prevented from high load. (CICA/Dr. Fixit/FOSROC).
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm. Note: Fitting & fixtures should be compatible with those already installed in the Institute buildings.
Part - B: Deduction Items: Deduct for removed old bib cock, pillar cock, stop cock, etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed.
Deduct for removed of old wall mixture etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed.
Deduct for removed old rusted GI pipes of the following dia etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed. 32mm dia.
Deduct for removed old rusted GI pipes of the following dia etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed. 40mm dia.
Deduct for removed old rusted GI pipes of the following dia etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed. 50mm dia.
Deduct for removed old rusted GI pipes of the following dia etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed. 75 mm dia.
Deduct for removed old flush tanks. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed.
Deduct for removed old seat cover. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed.
Deduct for removed old Gate valve etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed. 20mm / 15mm dia.
Deduct for removed old Gate valve etc. Taken away from IIT campus as directed by Engineer in charge. (These item to be deducted for the replacement of new items and obtaining gate pass from the Engineer in charge as directed. 25mm / 32mm dia.
Deduction items Deduct the cost of damaged flush door shutter removed will be permitted to taken by the contractor by making payment to the Institute as directed. The items will consists of with or without frame including furniture fittings available in the door shutter. this items will be permitted to taken by the contractor as per the direction by the engineer in charge area up to 3.00 sqm
Deduct the cost of damaged paneled or Glazed door / window shutter is removed while replacement .The paneled shutter will be permitted to taken by the contractor with / without frame inclusive of furniture fittings as per the directed by the Engineer in Charge by making payment to the Institute for an area up to 3.00 sqm
Deduct cost of old aluminum section
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .