| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Accepted-AOC Agreement executed by SURESH T on 20.07.2022 | |
| 2 | L2₹6.9 L+₹30,441 (4.63%)Rejected-AOC ERNAKULAM | KERALA | 680667 | L2 | Rejected-AOC Agreement executed by SURESH T on 20.07.2022, hence 2nd lowest EMD may be released | |
| 3 | Rejected-Technical BETHAL THIRUMALA TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | - | Rejected-Technical L3 |
Tender Value
₹7.8 L
EMD Value
₹19,400
Closing Date
2 Jun 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Thiruvananthapuram Corporation 695033 Superintending Engineer
Providing electrification to the proposed Park at Pallithura under City Corporation Thiruvananthapuram.
2022_LSGD_492103_2
DB/62983/2022-23 (18)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,600
Yes
₹19,400
Yes
14 Nov 2023
26 May 2022
4 Jun 2022
26 May 2022
2 Jun 2022
26 May 2022
60 days
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC ivory Conduit of minimum size 20mm conforming to IS 9537 Part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade including providing switch board main and continuous earthing with 1.5 sqmm green coloured FR wire required quantity of copper earth socket, brass bolt and nuit crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.(ROHS Complaint modular accessories)
Single control light point with 6A, 3 plate ceiling rose.
90.2.1.3 Single control light point without ceiling rose
90.2.1.4 Single controll ceiling fan point with 6A.3 plate ceiling rose and with socket typepped electronic regulator
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
Independent plug
Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep (category B) 5 star rated.
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).
3 core 16 sq mm
MR 875 3 core 1.50 sq mm
MR 876 4 core 1.50 sq mm
MR 888 3 core 2.50 sq mm
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
MR 1199 305 mm sweep 900 RPM heavy duty exhaust fan working on 230V A/C.
MR 1195 200 mm sweep light duty exhaust fan in plastic body with self opening lowers working on 230V A/C.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. Module (125 x 125mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 Amp socket outlet.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 Amp switch.
LMR supply and fixing wall flood light using 30W LED Halogen warm/ green colour lamp for suitable fabricated bracket in the concrete base and giving connection.
od 355042/2018-2019 supply and installation of fixtures & 1 r.br & gt Bollard
LMR supply and fixing wall flood light using 30W LED Halogen warm/ green colour lamp for suitable fabricated bracket in the concrete base and giving connection.
LED TV 138.78 cm 55 inch
14.10 Foundation concrete
od 105603/2019-20 Tore steel (Re-inforce)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and providing the following sizes of casr iron gully trap with covering at the top of the inspection chamber of earth pit as required. 300 x 300x6 mm cast iron gully trap with covering.
Supply and providing test point for the earthing system using 2 nos of the following sizes of strps including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2x25x3 mm GI strip.
Supply and providing earth lead from the test joint to the earth electrode using following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 x 3 mm GI strip
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required.
2.00 mm copper conductor (6 SWG)
3.15 mm copper conductor (14 SWG)
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc as required (in ordinary soil)
3.15.00mm copper conductor (6 SWG)
(90.6.4.12) Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
1.50 sq mm 2 run
1.50 sq mm 3 run
2.50 sq mm 3 run
6.00 sq mm 4 run
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required. 12 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
RCCB 300 mA 63A
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral.
100A, 415V, 50 Hz, AC 23 A duty, 4 pole switch disconnector unit.
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment knock out for cable entry and exit
S & F switch disconnector unit (isolator) complete with handle assmebly, door inter lock and padlocking arrangement of the following ratings
or supply and fixing the following accessories in the eisting meter board and giving connections etc. 63A 415V DIN type fuse base
63A 415V Backelite fuse fittings
63A 415V 2 way neutral link mounted on DMC/SMC base
Amount remitted to KSEB for obtaining Power supply (actual amount will be reimpersed on prodution of original receipts)
B SASIKUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_706647.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .