Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | ₹38.3 L Quoted ₹39.6 L | L1 | Accepted-AOC L1 being accepted |
| 2 | L2₹39.9 L+₹38,250 (0.97%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹39.9 L+₹38,250 (0.97%) | L2 | Rejected-Finance L1 being accepted |
| 3 | L3₹46.2 L+₹6.6 L (16.7%)Rejected-Finance THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | ₹46.2 L+₹6.6 L (16.7%) | L3 | Rejected-Finance L1 being accepted |
| 4 | L4₹58.7 L+₹19.2 L (48.4%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | ₹58.7 L+₹19.2 L (48.4%) | L4 | Rejected-Finance L1 being accepted |
| 5 | L5₹58.8 L+₹19.2 L (48.5%)Rejected-Finance | ₹58.8 L+₹19.2 L (48.5%) | L5 | Rejected-Finance L1 being accepted |
| Sl No | Description | Qty | Unit | Glacier Cooling Solutions Private Limited L1 | Jack Electrolinks Private Limited L4 | SREEKRUPA ENTERPRISES L2 | Green Ray Enterprises L3 | ELSOL ENGINEERS L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, Testing & Commissioning of VRV/VRF outdoor system of capacity 46 HP by replacement of existing BER declared three outdoor units (18 HP - 02 Nos, 10 HP - 1 No), 3 phase with master-slave technology. The outdoor unit shall include adequate refrigerant gas throughout circuit, oil separator, all safety devices like thermal protector, pressure relief valve, structural/angle/hanging supports, high-low pressure cut out, with ODU vibration isolators complete all as per the technical specifications as existing system, lifting ODUs to terrace at 1st floor including making good to existing RCC support structure and loweing/ shifting unserviceable units to MES store complete all as specified and directed. The VRV/VRF Outdoor system as below. Type : Modular connected VRV/VRF system, master-slave technology. Each outdoor compressors : Hermitically sealed scroll compressors, 2 Nos compressors (standard and inverter). Power supply : 3 phase, 380-415v, 50 Hz. Refrigerant : R 410A. Drive motor for air flow fan : DC, single phase, BLDC type motor, Sound level : not more than 61 dB from each unit at 1 mtr distance, Existing VRV outdoor unit : 18 HP - 02 Nos (RXYO18ARY6), 10 HP - 1 No (RXYQ10ARY6). Notes: 1. The quoted rate inclusive for disconnection of unnserviceable units electrical connections, copper piping and loweing from 1st floor of Aryabhatta building and shifting to MES store. 2. The quoted rate is inclusive of outdoor units, internal cabling/control cabling work and cabling for master-slave technology and making good of existing foundation. 3. The quoted rate is inclusive of to give training to MES staff after installation. | 1 | EACH JOB | 16,99,000 ₹16,99,000 | 23,80,000 ₹23,80,000 | 13,50,000 ₹13,50,000 Lowest | 21,00,000 ₹21,00,000 | 24,00,000 ₹24,00,000 |
| 2.00 | Supply, install, Testing & Commissioning of 8 TR ceiling mounted ductable VRV/VRF indoor units with drain pump, wireless remote controller, drive/ motor, electrical controller, temperature controller with digital display, thermostat, complete with necessary vibration isolators, connection with existing PVC drain pipe and all other safety controls as per OEM including disconnections of existing indoor unit electrical connections/removal of duct, lowering, shifting unserviceable unit to MES store complete all as specified and directed. The details are as under : Type : Ceiling mounted, ductable VRV/VRF indoor unit, Power supply : Single phase, 230V, 50 Hz. Refrigerant control : Electronic expansion valve, controller : Wireless remote controller. | 1 | EACH JOB | 1,15,000 ₹1,15,000 Lowest | 1,95,000 ₹1,95,000 | 1,50,000 ₹1,50,000 | 2,00,000 ₹2,00,000 | 2,40,000 ₹2,40,000 |
| 3.00 | All as per item No. 2 above but of 6.4 TR Capacity complete all as specified and directed. | 5 | EACH JOB | 98,000 ₹4,90,000 Lowest | 1,82,000 ₹9,10,000 | 1,30,000 ₹6,50,000 | 2,00,000 ₹10,00,000 | 2,25,000 ₹11,25,000 |
| 4.00 | All as per item No. 2 but of 4 TR Capacity complete all as specified and directed. | 1 | EACH JOB | 77,000 ₹77,000 Lowest | 1,25,000 ₹1,25,000 | 1,10,000 ₹1,10,000 | 95,000 ₹95,000 | 1,45,000 ₹1,45,000 |
| 5.00 | S&F in replacement of Branch Kit for VRVs Double Out Door Unit System (BHFP22P1356) complete all as specified and directed. | 2 | EACH JOB | 10,500 ₹21,000 Lowest | 14,000 ₹28,000 | 17,000 ₹34,000 | 18,000 ₹36,000 | 25,000 ₹50,000 |
| 6.00 | S&F in replacement of Y-Joint for VRVs in Door Unit including Insulation complete all as specified and as directed. Note for Item No. 1 to 6 : (i) The quoted rate is inclusive of control wiring from VRV outdoor to indoor units. (ii) The contractor has to submit VRV system arrangement (copper piping, communication arrangement, etc) drawing alongwith final bill. (iii) The contractor has to ensure availibility OEM rep during commissioning without extra cost. (iv) Leak test to be carried out after completion of copper piping and installation work before gas charging with approval of Engr-in-charge. Cost of nitrogen gas leak test measured and paid separately. | 6 | Each | 8,500 ₹51,000 | 5,200 ₹31,200 Lowest | 6,500 ₹39,000 | 7,100 ₹42,600 | 7,200 ₹43,200 |
| 7.00 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 34.9mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 100 | RM | 3,000 ₹3,00,000 | 3,000 ₹3,00,000 | 4,500 ₹4,50,000 | 1,200 ₹1,20,000 Lowest | 1,500 ₹1,50,000 |
| 8.00 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 28.6mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 60 | RM | 2,400 ₹1,44,000 | 2,000 ₹1,20,000 | 4,000 ₹2,40,000 | 900 ₹54,000 Lowest | 1,200 ₹72,000 |
| 9.00 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 22.2mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 50 | RM | 1,800 ₹90,000 | 1,500 ₹75,000 | 3,800 ₹1,90,000 | 700 ₹35,000 Lowest | 1,000 ₹50,000 |
| 10.00 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 19.1 mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 100 | RM | 1,700 ₹1,70,000 | 1,300 ₹1,30,000 | 3,000 ₹3,00,000 | 600 ₹60,000 Lowest | 800 ₹80,000 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
20 Aug 2026, 6:00 pmClosed
CWE Ezhimala Indian Naval Academy PO 670310
CWE Ezhimala Indian Naval Academy PO 670310
As per BOQ and tender documents
2026_MES_780510_1
80528
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE Ezhimala Indian Naval Academy PO 670310
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (M) Ezhimala
₹84,000
17 Sept 2026
24 Jul 2026
24 Aug 2026
25 Jul 2026
20 Aug 2026
7 Aug 2026
25 Jul 2026 - 31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Install, Testing & Commissioning of VRV/VRF outdoor system of capacity 46 HP by replacement of existing BER declared three outdoor units (18 HP - 02 Nos, 10 HP - 1 No), 3 phase with master-slave technology. The outdoor unit shall include adequate refrigerant gas throughout circuit, oil separator, all safety devices like thermal protector, pressure relief valve, structural/angle/hanging supports, high-low pressure cut out, with ODU vibration isolators complete all as per the technical specifications as existing system, lifting ODUs to terrace at 1st floor including making good to existing RCC support structure and loweing/ shifting unserviceable units to MES store complete all as specified and directed. The VRV/VRF Outdoor system as below. Type : Modular connected VRV/VRF system, master-slave technology. Each outdoor compressors : Hermitically sealed scroll compressors, 2 Nos compressors (standard and inverter). Power supply : 3 phase, 380-415v, 50 Hz. Refrigerant : R 410A. Drive motor for air flow fan : DC, single phase, BLDC type motor, Sound level : not more than 61 dB from each unit at 1 mtr distance, Existing VRV outdoor unit : 18 HP - 02 Nos (RXYO18ARY6), 10 HP - 1 No (RXYQ10ARY6). Notes: 1. The quoted rate inclusive for disconnection of unnserviceable units electrical connections, copper piping and loweing from 1st floor of Aryabhatta building and shifting to MES store. 2. The quoted rate is inclusive of outdoor units, internal cabling/control cabling work and cabling for master-slave technology and making good of existing foundation. 3. The quoted rate is inclusive of to give training to MES staff after installation. | 1 | EACH JOB | - | - |
| 2 | Supply, install, Testing & Commissioning of 8 TR ceiling mounted ductable VRV/VRF indoor units with drain pump, wireless remote controller, drive/ motor, electrical controller, temperature controller with digital display, thermostat, complete with necessary vibration isolators, connection with existing PVC drain pipe and all other safety controls as per OEM including disconnections of existing indoor unit electrical connections/removal of duct, lowering, shifting unserviceable unit to MES store complete all as specified and directed. The details are as under : Type : Ceiling mounted, ductable VRV/VRF indoor unit, Power supply : Single phase, 230V, 50 Hz. Refrigerant control : Electronic expansion valve, controller : Wireless remote controller. | 1 | EACH JOB | - | - |
| 3 | All as per item No. 2 above but of 6.4 TR Capacity complete all as specified and directed. | 5 | EACH JOB | - | - |
| 4 | All as per item No. 2 but of 4 TR Capacity complete all as specified and directed. | 1 | EACH JOB | - | - |
| 5 | S&F in replacement of Branch Kit for VRVs Double Out Door Unit System (BHFP22P1356) complete all as specified and directed. | 2 | EACH JOB | - | - |
| 6 | S&F in replacement of Y-Joint for VRVs in Door Unit including Insulation complete all as specified and as directed. Note for Item No. 1 to 6 : (i) The quoted rate is inclusive of control wiring from VRV outdoor to indoor units. (ii) The contractor has to submit VRV system arrangement (copper piping, communication arrangement, etc) drawing alongwith final bill. (iii) The contractor has to ensure availibility OEM rep during commissioning without extra cost. (iv) Leak test to be carried out after completion of copper piping and installation work before gas charging with approval of Engr-in-charge. Cost of nitrogen gas leak test measured and paid separately. | 6 | Each | - | - |
| 7 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 34.9mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 100 | RM | - | - |
| 8 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 28.6mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 60 | RM | - | - |
| 9 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 22.2mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 50 | RM | - | - |
| 10 | S&F in replacement of refrigerant piping of hard drawn copper pipe of size 19.1 mm dia duly insulated with 19 mm nitrile rubber pipe sleeves to the insulation and aluminium cladding as required including tees, bends, bracing as required and removal of unserviceable copper piping at site complete all as specified and as directed. | 100 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TD80528.pdf
Tender Documents • 0.44 MB
PS80528.pdf
Tender Documents • 0.14 MB
BOQ_874304.xls
BOQ • 0.31 MB
corigendum1.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .