| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ok | |
| 2 | L2₹26.6 L+₹87,340.86 (3.39%)Rejected-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L2 | Rejected-AOC ok | |
| 3 | L3₹27.0 L+₹1.3 L (4.93%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹27.2 L+₹1.4 L (5.59%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC ok | |
| 5 | L5₹28.9 L+₹3.1 L (12.0%)Rejected-AOC | L5 | Rejected-AOC ok |
Tender Value
₹32.8 L
EMD Value
₹65,600
Closing Date
5 Feb 2022, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
SPL REPAIR,RENOVATION TO BLDG NO T-22 (OLD RICE SHED) AND T-11 (NECESSARY GP STORES) OF 447 COY ASC (SUP) AT DEHRADUN
2022_MES_500130_1
9663/DDN/E8
Open Tender
Civil Works
Item Rate
120 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹65,600
Yes
10 Mar 2022
7 Jan 2022
7 Feb 2022
7 Jan 2022
5 Feb 2022
22 Jan 2022
Amount
Demolition brick or stone masonry built in cement mortar including all quoins arches pillars etc but excluding ashlars facing dressed stone work and precast concrete block, complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6 ) complete all as specified and directed.
All as per item No. 03 above but except bricks.
M&L for brick work with sub class 'B' brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
Taking down cement plaster of any description from brick/stone/concrete surface of wall of any description including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in lime or cement mortar; not previously plastered; and scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and directed.
M&L for complete removal of existing treatment from wall up to brick work or plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper complete all as specified and directed.
M&L for preparation of old plastered surface of wall and applying two coats of cement base paint over a coat of primer on external wall surfaces complete all as specified and directed.
M&L for preparation of old surface of wall and applying three coats of white wash on internal wall surfaces complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying three coat of white wash complete all as specified and directed.
Taking down chowkhats or frames with shutters n. exc 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed.
All as per item No 15.00 here in above but exc.1.5 Sqm and not exceeding 4 Sqm each.
S&F factory made 100 % solid wood plastic composite (WPC) door frame 125x65 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed.
S&F 35 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door shall be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and directed.
S&F mild steel framed work for such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling hole complete all as specified and directed.
S& F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc. complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F factory made steel window with side-hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc. complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F powder coated aluminium ventilator fixed type half glazed and half gauged with and including hardware fittings, glazing, wire gauge, rubber packing, aluminium beading etc. as specified below including taking down old window/ventilator and making good of wall surface to match with existing surface complete all as specified and directed of followint sizes (i) Frame : 44.5 x 44.5 mm x 1.80 mm thick (ii) Middle rail : 44.5 x 44.5 mm x 1.80 mm thick. (iii) Glazing: 5 mm thick frosted glass fixed with rubber gasket and aluminium beading. (iv) Wire gauge: stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium beading.
S&F powder coated aluminium grill with frame fixed to by means stainless steel screws complete all as specified and directed.
S&F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F stainless steel barrel tower bolts 200 mm long one piece and fixed complete all as specified and directed.
S&F stainless steel butt hinges, medium weight 150 mm long one piece and fixed with screws/welded to frame complete all as specified and directed.
S&F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame complete all as specified and directed.
S&F 300 mm long stainless steel sliding door bolt, bolt not less than 12 mm dia with hasp & staple and fixing clips of SS sheet, and SS fixing bolts and fixed complete all as specified and directed.
M & L floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and directed.
Taking down/ dismantling steel (corrugated, semi corrugated, etc.) sheets in roof coverings of any gauge, thickness complete all as specified and directed.
Taking down/ dismantling asbestos (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
S&F for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on old painted steel surfaces of any description including preparation of steel surfaces complete all as specified and directed.
M&L for preparation of old painted surfaces of wood & wood based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for 25 mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floor complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including 20 mm thick cement mortar 1:6 screed bed, laid, jointed and painted with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
M&L for machine cut kota stone slab flooring as in skirting 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed.
M&L for cutting holes in brick wall built in cement mortar exc half brick but n exc one brick for inserting or cement concrete (1:2:4) as in hold fast etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
M&L for 75 MM thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work and demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick in ground floor and paving below or above ground level complete all as specified and directed.
Excavation in trenches not exceeding 1.50 meter wide and not exceeding 1.50 meter depth for foundation, manhole etc not exc 10 Sqm on plan and not exc 1.5 meter in depth including getting out in soft/loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor etc complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in surface channel and drain including necessary use and waste of form work complete all as specified and directed.
Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25 centimeter in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil/material not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Taking up or down 200 mm dia steel tubing and connection complete all as specified and directed.
S & F 200 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenches complete all as specified and directed.
S&F plain, 1.00 mm thick galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 , fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed.
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) any type including unscrewing from board, fitting and fixture such as switches, ceiling roses, holders, regulators sockets ,light fittings etc removing materials from site and making good disturbed with the existing surfaces complete all as specified and directed.
M&L for point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multi stranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls, floors etc complete all as specified and directed for following.
One light point controlled by one way switch.
One three pin 5 Amp socket on same board with other switches
One three pin 5 Amp socket on independent board
All as per Item No 57 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S & F switch piano flush type single pole one way 230 Volts 6 Amp complete all as specified and directed.
S&F socket outlet 3 pin , 230 Volts 5/6 Amps flush type multipurpose 5 pin complete all as specified and directed.
S&F socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified and directed.
S&F switch piano; flush type, single pole, one way, 230 Volts 15/16 Amps complete all as specified and directed.
S&F in repairs for Ceiling rose, three terminal ISI marked surface Bakelite suitable for batten fitting complete all as specified and directed.
S&F in replacement of energy saving ,surface mounted, LED 10 watt Bulk head luminaire with decorative oval diffuser comprising of high brightness LEDs complete all as specified and directed.
S&F industrial lighting ,70 Watt with Eco well glass in PDC housing with a luminaire efficiency of 110 Lm/W, Superior tampered fin design with exceptional thermal management, ingress protection of IP66 complete all as specified and directed. Make :- Crompton greaves model no Supra neo -II(T), Cat Pt No TIP-311-70-57-SL-CP-NSG OR Equivalent in Philips/Havel’s
S&F in replacement for distribution board SPN 8 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process complete all as specified and directed.
S&F in replacement for distribution board SPN 4 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process complete all as specified and directed.
S&F in repair MCB single pole, 240 volt, 10 KA, 5-32 Amp, 'C' series complete all as specified and directed.
S&F in repair MCB SPN, 240 Volt 10 KA 25 to 40 Amp 'C' series complete all as specified and directed.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multi stranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium duty PVC concealed conduit/flexible conduit where required and conduit accessories and fittings. Including one single core green colour PVC insulated unsheathed cable copper conductor multi stranded of size 4 Sqmm as earth wire up to common earth and connected to earth dolly complete including taking out old unserviceable sub main wiring complete all as specified and directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed including demolition to existing earthing complete all as specified and directed.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade, nominal cross sectional area 10 Sqmm 2 core including lugs and heat shrinkable PVC Sleeves on exposed surfaces & Teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed.
Supply & laying sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness all complete all as specified and directed. Note :- Only punned down sand thickness 18CM shall be measured and paid.
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and directed.
Supply & Laying in replacement of GI Steel tubing light grade 40 mm(2") dia including all fitting laying in trenches across road or grouting /fixing on wall for protection of cable complete all as specified and directed.
M/s RP AGRAWAL
M/S JAI PRAKASH GOEL
M/s Pradeep Kumar
m/s yogesh kumr ontractor
M.K Engineers
M/S RAJESH KUMAR GOYAL
M/S DHYANI CONSTRUCTION CO.
AYUSH CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .