Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC ATRIA APARTMENTS 6TH FLOOR A 6 OPPOSITE GURUDWARA PERUMANOOR POST KOCHI 682015 | KOCHI | ERNAKULAM | KERALA | 682015 | ₹45.3 L Quoted ₹46.3 L | L1 | Accepted-AOC BEING LOWEST AND REASONABLE |
| 2 | L2₹48.8 L+₹2.5 L (5.44%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | ₹48.8 L+₹2.5 L (5.44%) | L2 | Rejected-Finance Rejected due to not being L1 |
| 3 | L3₹50.9 L+₹4.6 L (9.88%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | ₹50.9 L+₹4.6 L (9.88%) | L3 | Rejected-Finance Rejected due to not being L1 |
| 4 | L4₹51.6 L+₹5.2 L (11.3%)Rejected-Finance 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | ₹51.6 L+₹5.2 L (11.3%) | L4 | Rejected-Finance Rejected due to not being L1 |
| 5 | L5₹53.6 L+₹7.2 L (15.6%)Rejected-Finance | ₹53.6 L+₹7.2 L (15.6%) | L5 | Rejected-Finance Rejected due to not being L1 |
| Sl No | Description | Qty | Unit | Anaswara Constructions L4 | MS BUILDERS L2 | M/s T.P SHAJI L1 | Suprisons L6 | ANIE JOHN CONTRACTORS L3 | JKM CONSTRUCTIONS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Notes for item Nos 1 to 9 (a) safaiwala as per requirement will be present on all working days including sunday 0900 hrs to 1700 hrs and report to complaint cell for collecting the complaints and all complaints to be attend (except major complaints) within 8 hours, if not attended on same day an amount of Rs 250/- per complaints will be deducted from the contractor's payment for not attending complaints. | |||||||||
| 1.01 | Opening the man holes of septic tanks, removing night soil, other sediments, solid waste, and liquid waste in any condition by pumping or any other mechanical means, using sewage sucking truck, cleaning internal surfaces of the tank with clean water and refix the man hole cover on completion of work, complete all as specified and as directed by Engineer In Charge.
Notes:- (a) The night soil, other sediments, solid waste, and liquid waste in any condition removed from septic tank shall be taken away from respective vicinities and NB(K) Premises on closed containers/conveyance and disposed off out of defence land
(b) Disposal of the same shall be the responsibility of the contractor with out any extra expenditure to government. Disposal of waste shall be made in accordance with the regulations of authorities concerned.
c) The unit rate quoted shall be deemed to be inclusive of cleaning the nearby MH & sewage line from that MH to septic tank. | 75 | Per Cum | 375 ₹28,125 | 350 ₹26,250 | 320 ₹24,000 Lowest | 380 ₹28,500 | 400 ₹30,000 | 360 ₹27,000 |
| 2.00 | All as per item No-1 here-in-before but for manhole of area not exc 1 Sqm in plan and depth not exc 1 m complete all as specified and as directed | 100 | Each | 60 ₹6,000 | 60 ₹6,000 | 50 ₹5,000 Lowest | 50 ₹5,000 Lowest | 70 ₹7,000 | 75 ₹7,500 |
| 3.00 | All as per item No-1 here-in-before but for manhole of area not exc 1 Sqm in plan and depth exc 1 m to n exc 1.5m complete all as specified and as directed | 75 | Each | 50 ₹3,750 | 30 ₹2,250 Lowest | 50 ₹3,750 | 40 ₹3,000 | 30 ₹2,250 Lowest | 55 ₹4,125 |
| 4.00 | All as per item No-1 here-in-before but for manhole of area not exc 1 Sqm in plan and depth exc 1.5 m to n exc 2m complete all as specified and as directed | 25 | Each | 60 ₹1,500 | 60 ₹1,500 | 55 ₹1,375 Lowest | 75 ₹1,875 | 70 ₹1,750 | 80 ₹2,000 |
| 5.00 | All as item No-1 here-in-before but for cleaning of sewage line/effluent drains 100mm dia below/above GL complete all as specified and as directed. | 250 | Per RM | 35 ₹8,750 Lowest | 35 ₹8,750 Lowest | 50 ₹12,500 | 65 ₹16,250 | 50 ₹12,500 | 60 ₹15,000 |
| 6.00 | All as item No-1here-in-before but for cleaning of sewage line/effluent drains 150mm dia below/above GL complete all as specified and as directed. | 150 | Per RM | 50 ₹7,500 | 40 ₹6,000 Lowest | 60 ₹9,000 | 70 ₹10,500 | 40 ₹6,000 Lowest | 50 ₹7,500 |
| 7.00 | Cleaning of culvert and covered drains of any size incl removal of RCC cover slab and refixing in same position after the cleaning incl necessary minor repairs to wide wall of brick masonry/concrete incl setting and joining the cover slab in cement mortar 1:6 and removing the silt and dirt to a distance exc 200 and n,exc 250 m from starting point and disposed off (span of culvert upto 1m) complete all as specified and as directed. | 75 | Per RM | 35 ₹2,625 | 30 ₹2,250 Lowest | 40 ₹3,000 | 50 ₹3,750 | 30 ₹2,250 Lowest | 45 ₹3,375 |
| 8.00 | Removing the chokes of WC/bathroom/kitchen traps/drains up to Ist manholes including cleaning of gully traps in single storied/ground floor of multistoried bldgs complete all as specified and as directed. | 100 | Per choke | 50 ₹5,000 Lowest | 50 ₹5,000 Lowest | 55 ₹5,500 | 75 ₹7,500 | 65 ₹6,500 | 55 ₹5,500 |
| 9.00 | All as per item No.8 above but multistorey buildings except ground floor complete all as specified and as directed. | 150 | Per choke | 60 ₹9,000 Lowest | 60 ₹9,000 Lowest | 65 ₹9,750 | 75 ₹11,250 | 60 ₹9,000 Lowest | 75 ₹11,250 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
6 Aug 2025, 6:00 pmClosed
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2025_MES_718872_1
8473_GE_NW
Open Tender
Civil Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,800
10 Oct 2025
7 Jul 2025
9 Aug 2025
7 Jul 2025
6 Aug 2025
23 Jul 2025
7 Jul 2025 - 23 Jul 2025
Amount
Notes for item Nos 1 to 9 (a) safaiwala as per requirement will be present on all working days including sunday 0900 hrs to 1700 hrs and report to complaint cell for collecting the complaints and all complaints to be attend (except major complaints) within 8 hours, if not attended on same day an amount of Rs 250/- per complaints will be deducted from the contractor's payment for not attending complaints.
Opening the man holes of septic tanks, removing night soil, other sediments, solid waste, and liquid waste in any condition by pumping or any other mechanical means, using sewage sucking truck, cleaning internal surfaces of the tank with clean water and refix the man hole cover on completion of work, complete all as specified and as directed by Engineer In Charge. Notes:- (a) The night soil, other sediments, solid waste, and liquid waste in any condition removed from septic tank shall be taken away from respective vicinities and NB(K) Premises on closed containers/conveyance and disposed off out of defence land (b) Disposal of the same shall be the responsibility of the contractor with out any extra expenditure to government. Disposal of waste shall be made in accordance with the regulations of authorities concerned. c) The unit rate quoted shall be deemed to be inclusive of cleaning the nearby MH & sewage line from that MH to septic tank.
All as per item No-1 here-in-before but for manhole of area not exc 1 Sqm in plan and depth not exc 1 m complete all as specified and as directed
All as per item No-1 here-in-before but for manhole of area not exc 1 Sqm in plan and depth exc 1 m to n exc 1.5m complete all as specified and as directed
All as per item No-1 here-in-before but for manhole of area not exc 1 Sqm in plan and depth exc 1.5 m to n exc 2m complete all as specified and as directed
All as item No-1 here-in-before but for cleaning of sewage line/effluent drains 100mm dia below/above GL complete all as specified and as directed.
All as item No-1here-in-before but for cleaning of sewage line/effluent drains 150mm dia below/above GL complete all as specified and as directed.
Cleaning of culvert and covered drains of any size incl removal of RCC cover slab and refixing in same position after the cleaning incl necessary minor repairs to wide wall of brick masonry/concrete incl setting and joining the cover slab in cement mortar 1:6 and removing the silt and dirt to a distance exc 200 and n,exc 250 m from starting point and disposed off (span of culvert upto 1m) complete all as specified and as directed.
Removing the chokes of WC/bathroom/kitchen traps/drains up to Ist manholes including cleaning of gully traps in single storied/ground floor of multistoried bldgs complete all as specified and as directed.
All as per item No.8 above but multistorey buildings except ground floor complete all as specified and as directed.
S&F in repair for removal of old PVC/cast iron floor trap including wall crossing pipe and fixed with new outlet 75mm pvc (swr) floor trap with stainless steel grating and new wall crossing and filling with PCC 1:2:4 with water proofing compound including matching with existed tile and joining with outer pipe line with solvent complete all as specified and as directed.
S&F in repair for removal of old PVC/cast iron floor trap including wall crossing pipe and fixed with new outlet 110mm pvc (swr) floor trap with stainless steel grating and new wall crossing and filling with pcc 1:2:4 with water proofing compound including matchng with existed tile and joining with outer pipe line with solvent complete all as specified and as directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth for foundation, man holes etc and getting out in soft/loose soil complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, 100mm pipe complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, 150mm pipe complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, 200mm pipe complete all as specified and as directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, etc as required complete all as specified and as directed.
S&F 150mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, etc as required complete all as specified and as directed.
M&L for Reinforced concrete pipes class NP2 of 200 mm dia laid and jointed with collars complete all as specified and as directed.
M&L for cement concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:3:6 type C2 with 40mm graded stone aggregate, dia of pipe 100mm complete all as specified and as directed.
M&L for cement concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:3:6 type C2 with 40mm graded stone aggregate, dia of pipe 150mm complete all as specified and as directed.
M&L for cement concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:3:6 type C2 with 40mm graded stone aggregate, dia of pipe 200mm complete all as specified and as directed.
M&L for cutting into the manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm bore pipe complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25cm thick (Soft/loose soil) complete all as specified and as directed.
Removing excavated material exc. 250m but n.exc 500m and depositing where directed complete all as specified and as directed.
Demolition of reinforced cement concrete in any description and in any position not otherwise specifically provided for (reinforcement cut to facilitate demolition) complete all as specified and as directed.
M&L for providing precast cement concrete in cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces, Type B1 1:2:4 (20mm graded stone aggregate) set in cement mortar 1:6 complete all as specified and as directed.
S&F in repair CI manhole covers of size area exc 0.12Sqm but n. exc 0.38 Sqm along with frame complete all as specified and as directed.
S&F in repair FRP manhole covers of size area exc 0.12 Sqm but n exc 0.38 Sqm along with frame complete all as specified and as directed.
M&L fro mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not lessthan 0.9mm dia or securing with clips complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) or any type of pipe, including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal from site (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors , 75mm bore pipe complete all as specified and as directed.
S&F cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, 75mm bore pipe complete all as specified and as directed.
S&F repair cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors , 100mm bore pipe complete all as specified and as directed.
S&F repair cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, 100mm bore pipe complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls , 75mm bore pipe complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls , 110mm bore pipe complete all as specified and as directed.
S&F cast iron vent cowl slotted, 75mm complete all as specified and as directed.
S&F in repair cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with access door, 100mm bore complete all as specified and as directed.
S&F in repair cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with access door, 80mm bore complete all as specified and as directed.
S&F in repair cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), 100mm bore complete all as specified and as directed.
S&F in repair cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) , 80mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches , 100mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches , 75mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 100mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches , 75mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with access door, 100mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with access door, 80mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with access door, 100mm bore complete all as specified and as directed.
S&F in repair cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with access door, 75mm bore complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius with access door, 75mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius with access door, 110mm bore complete all as specified and as directed.
S&F PVC (SWR) floor trap 75mm bore plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) gully traps 125/100mm setting and jointed in cement solvent complete all as specified and as directed.
S&F 75mm stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
S&F 100mm stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
Destruction of growth of weed plants with roots from on the roof top of bldgs and the walls of bldg, at any position and height, by completely removing the growth and applying 2.40 'D' oil mixed with Veedol chemical solution and sprayed on and around roots and at places of possible growth of weeds and making good damaged surfaces in cement mortar 1:4 of PCC 1:1 1/2:3 as required and directed
M&L for hume pipe septic tank 25 users capacity incl AC vent pipe, earth work excavation in soft/loose soil, erecting hume pipe septic tank in position, PCC 1:3:6 and all other accessories required such as vent cowl etc and making good the disturbed surface and removing surplus soil and old u/s septic tank, complete incl connecting to the sewer line etc complete incl demolition of old septic tank and disconnect the connection and provide new connections to the new septic tank complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Demolition of cement concrete in any description and in any position not otherwise specifically provided complete all as specified and as directed.
M&L for cement concrete in foundations, filling and mass-concrete type B2, 1:2:4, 40mm graded stone aggregate complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling fencing wire mesh, any type complete all as specified and as directed.
S&F MS galvanised chain link fencing of grid size 80x80mm, 4mm dia wire (weight not less than 3.25 Kg/Sqm) including line wires, mesh of any size and type, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290-0 Gde E 165 complete all as specified and directed.
M&L for mild steel screw bolts 5 to 10 dia of neck in mm(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed.
M&L framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F rolled sections as in main pillars and cross beams, hip and jack rafters, purlins where connected to common rafters and fixed with angle cleats or other connecting plates of Fe 410-W Gde E-250 quality A complete all as specified and as directed.
M&L for preparing new surfaces of steel, any description, over 10cm in width or girth, not otherwise described and applying two coat of anti corrosive paint over a coat of epoxy primer complete all as specified and as directed.
M&L for preparing old treated steel surfaces of any description exc 10 cm width or girth and applying one coat of Anti corrosive paint complete all as specified and as directed.
M&L for preparing old treated steel surfaces of any description any width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Demolition of precast PCC block masonry / brick work or stone / boulder masonry including all quions, arches, pillars, etc built in cement mortar or cement lime mortar complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 with 20mm graded aggregate as in coping complete all as specified and as directed.
M&L for plain cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in foundation complete all as specified and as directed.
M&L fro Pre-cast cement concrete block masonry in PCC 1;3;6 type C1(20MM graded aggregate) with solid block, exc. 10 cm in width and setting in cement mortar,1:6 complete all as specified and as directed.
M&L for providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed), type C1 1:3:6 (20mm graded aggreagate) setting in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster, in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material, complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 with WPC on fair face of brick/concrete work, surface finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick/concrete wall surfaces finishing surfaces even and smooth with out using extra cement complete all as specified and as directed.
M&L for preparing surfaces of new plastered surfaces, applying two coat of cement base paint over a coat of alkali resistant primer as per manufacturer's instructions complete all as specified and as directed.
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two top coats of exterior anti fungal acrylic emulsion paint over a coat of exterior water base coat and exterior putty wherever required all as specified and prescribed by manufacture of point and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of materials (like putty, base coat/topcoat of exterior paint), labour & T&P wherever required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture. Guarantee certificate should provide from the authorised applicator of manufacturer and shall be got approved from GE. (iii). after carrying out preparation of surface the same shall be got approved before application of exterior emulsion for each building. (iv) The cost of Scaffolding and safety measures wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and treating oil and greasy spots etc and applying one coat of white washing on wall complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and treating oil and greasy spotsetc and applying one coat of colour wash complete all as specified and directed.
M&L for preparing old treated surface of existing treatment on external surfaces of wall and applying one coat cement based paint including filling cementious exterior grade wall care putty on disturbed portion of wall as required complete all as specified and as directed.
M&L for preparation of newly plastered surface of exterior wall and applying two top coats of exterior anti fungal acrylic emulsion paint over a coat of exterior water base coat and 1-1.5mm thick exterior putty wherever required all as specified and prescribed by the manufacture complete all as specified and as directed.
M&L for preparation of old treated surface of existing treatment on external surfaces of wall and applying one coat cement based paint including filling cementious exterior grade wall care putty on disturbed portion of wall as required complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for cement concrete of type C2 1:3:6 (40mm graded stone aggregate) in surface channels and drains complete all as specified and as directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above GL) complete all as specified and as directed.
M&L for PCC1:3:6 type C2 (using 40mm graded stone aggregate) 75mm thick in plinth protection/ hard standing surface to be finished even and fair complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63mm broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for 75mm thick PCC 1:4:8 Type D-2 using 40 mm graded stone aggregate as in sub base of flooring complete all as specified and as directed.
M&L for coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm under floors or in foundations spreading and levelling in layers n exc. 25 cm thick well ramming including watering as required complete all as specified and as directed.
Demolition of stone slabs/tiles of any description or thickness laid and bedded in any mortar complete all as specified and as directed.
Dismantling of stone slabs/tiles of any description or thickness laid and bedded in any mortar complete all as specified and as directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete complete all as specified and as directed.
Laying only machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 60mm thickness, with grey cement and pigment complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 60mm thickness, with grey cement and pigment complete all as specified and as directed.
Laying only machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 80mm thickness, with grey cement and pigment complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 80mm thickness, with grey cement and pigment complete all as specified and as directed.
Dismantling floor tiling including cement mortar bedding removing serviceable bles to store and rubbish off the premises complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement with grey cement and no pigments in floors incl screed bed or bedding layer of mortar 20 mm thick screed bed in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7-8mm thick (square/rectangular), area of each tile not exc 0.11 Sqm, over and including 10mm thick screed bed in CM (1:4) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed.
M&L for heavy duty outdoor vitrified tiles 8-10mm thick (square/rectangular) grade-4, area of each tile exc 0.06 Sqm but not exc 0.11 Sqm over and including 15mm thick screed bed in Cement mortar (1:4) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed.
S&F in repair vitreous china squatting pan ‘Orissa pattern’ size 580x440mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white including fixing with trap including PVC matching seat cover complete all as specified and as directed.
S&F in repair vitreous china WHB white with flat back of size 550x400mm with bracket including waste coupling complete all as specified and as directed.
MS BUILDERS (BID ID -3377101)
ANIE JOHN CONTRACTORS (BID ID -3377620)
Anaswara Constructions (BID ID -3376953)
JKM CONSTRUCTIONS (BID ID -3377377)
Suprisons (BID ID -3377300)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .