Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.5 L+₹55,266.63 (3.96%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.2 L+₹1.3 L (9.11%)Rejected-Finance HIMACHAL PRADESH HP | MANDI | HIMACHAL PRADESH | 175047 | L3 | Rejected-Finance L3 | |
| 4 | L4₹15.4 L+₹1.4 L (10.2%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹15.9 L+₹1.9 L (13.9%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹13.3 L
EMD Value
₹26,600
Closing Date
6 Jan 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer HPPWD Division Paonta Sahib District Sirmour (H.P.)
Construction of additional accommodation in GSSS (Girls) at Pipliwala in tehsil Paonta Sahib, District Sirmour (HP) (SH Construction of Two Nos. additional class rooms)
2019_PWD_33318_1
Tender/2019-20-5638-87 dated 11.12.2019
Open Tender
Civil Works - Buildings
Item Rate
270 days
Paonta Sahib
Please refer tender document.
11 documents required · 11 mandatory
₹500
Yes
EE Paonta Sahib
₹26,600
Yes
8 Jul 2020
12 Dec 2019
7 Jan 2020
12 Dec 2019
6 Jan 2020
12 Dec 2019
Amount
Excavation in foundation,trenches in earth work in all heights and depths in all all kinds of soil including saturated soil comprising of pick work,jumper work,blasting work ( both soft & hard rock ) & shall be excavated with chiselling & wedging out rock ( where blasting is prohibited) and their intermediate classification of soil including dewatering wherever required setting out to required lines, levels as shown on the drawing and as directed by the Engineer-in-Charge at site, according to the HPPWD spacifiction of 1990 voume-I and sorting out useful & unuseful materials and stacking the same in all leads and lifts and transportaion of the unuseful materials for disposing at dumping sites (to be arranged by the contractor) through all modes of transportaion incding head load, animal load or mechanical means along with its levelling fine dressing and all labour machineries materials, tools equipements and safety measures and incidentals necessary to complete the work by mechanized means and labour (if required) .All usefull materials, such as stones shingles, aggregate and slates shall be sorted along road side to the maximum possible extent in all leads and lifts through all modes of transportaion and used and removed as per the direction of Engineer-in-Charge. Any loss to the public and private property during the course of execution and disposal of servicable and unserviceable materials shall be the aboulute responsiblity of the contractor and shall have to be duly compensated by him in all respects, including all incidental charges.
Filling in plinth with sand under floors including watering,ramming consolidating & dressing complete as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing form work with steel plates 3.15mm ( Three point one five milimeter )thick welded with angle iron in frames 30x30x5mm( Thirty into thirty into five milimeter ),so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4.00 meters ( four meters ) & removal of the same for in-situ reinforced concrete and plain concrete work as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge in:
Foundation,footings,basis of columns etc. & mass concrete .
Flat surfaces such as soffits of suspended floors, roofs, landing and the like floors etc. upto 200mm (two hundred milimetres) in thickness.
Columns, pillars, posts & struts, square, rectangular or polygonal in plan .
Beams, cantilevers, girders and lintels, sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1.00 metres ( one meter ) in depth in all heights from floor level.
Stair cases with slopping or stepped soffits excluding landing.
Edges of slabs & breaks in floors & walls under 20cm ( twenty centimeter ) wide in all floor level .
Providing & laying cement concrete 1:6:12 (One cement : six approved sand : twelve graded crushed stone aggregate 40mm ( forty milimeter ) nominal size )& curing complete excluding cost of form work in foundation & plinth as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing & laying cement concrete 1:4:8 (One cement : four approved sand : eight graded crushed stone aggregate 40mm ( forty milimeter ) nominal size )& curing complete excluding cost of form work in foundation & plinth as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete work mechnically mixed & vibrated 1 : 1.5 : 3 ( One cement : one & half approved sand : three graded crushed stone aggregate 20mm ( twenty milimeter ) nominal size ) & curing complete excluding cost of form work and reinforcement for reinforced concrete work as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge in:-
Foundation, footings, basis of columns etc. & mass concrete including carriage of materials within all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Suspended floors, roofs,landings & shelves & their supports,balconies,beams,girders,bressumers & cantilevers upto all floor level including carriage of materials within all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge. as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Columns,pillars, posts & strutts upto all floor level includingcarriage of materials within all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge. as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Stair cases ( except spiral stair case ) excluding landings but including preparing of the surface & finishing of nosing upto all floor level including carriage of materials within all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge. as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing & laying upto all levels reinforced cement concrete 1:2 :4 ( One cement : Two approved sand : Four graded crushed stone aggregate 20mm ( twenty milimeter )nominal size to give a smooth & even surface including centring & shuttering etc. but excluding cost of reinforcement as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge in:-
String courses,copings,bed plates,anchor blocks, plain windows sill & the like .
Providing tor steel reinforcement for reinforced cement concrete work including bending,binding & placing in position including cost of binding wire complete upto all floor level as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Brick work second class using common burnt clay building bricks in foundation and plinth in cement mortar 1:6 ( One cement : Six approved sand ) as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Brick work second class using common burnt clay building bricks in Super-structure above plinth upto all floor level in cement mortar 1:6 ( One cement : Six approved sand ) as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Half brick masonry using second common burnt clay building bricks in cement mortar 1:4 ( One cement : four approved sand ) as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Stone soling properly hand packed tightly under floor as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
P/F 12 mm thick prelaminated board both side bwp phenol bonded exterior/interior grade panalled shutters with frame of first class deodar wood for doors including bright finished/black enamelled iron butt hinges with necessary screws 40 mm thick frame as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing 19mm thick Commercial Board water proof shutters for cup boards i/c fixing with nickel plated piano hinges with screws etc complete as per HPPWD specification 1990 voume-I including carriage of all labour equipments and materials to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing anodized aluminium sliding door bolt anodized colour and shade with bolts and nuts screws etc. complete. as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing aluminium tower bolts (berrel type) anodized trans parent or dyed to required shade and colour with screws etc. complete as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing aluminium handles anodized transparent or dyed to required colour & shade with necessary screws etc. complete as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing & fixing mild steel plain grill of required pattern in windows etc. with M.S. flats 20*5 mm (twenty into five milimeters) and 8*8 mm (eight into 8 milimeters) square bars with screws etc. as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
40mm ( Forty milimeter )cement concrete flooring 1:2:4 (One cement : two sand : four graded stone aggregate 20mm ( Twenty milimeter ) nominal size ) laid in one layer finished with a floating coat of neat cement as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing & fixing glass strips 40mm wide & 4mm (Forty milimeter wide & four milimeter ) thick in joints of any type of floors as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
15mm ( Fifteen milimeter )thick cement plaster skirting ( Upto 30cm ( thirty centimeters ) height ) with cement mortar 1:3 ( One cement : three sand ) finished coat of neat cement including rounding of junction with floor as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing on wall face high pressure PVC spigot and socket, rain water pipes 110 mm (One hundred ten millimetres) dia ISI marked including filling with approved adhesive etc. complete .as per drawing and HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing on wall faces PVC accessorieds i.e. PVC Plain bend 110 mm (One hundred ten millimetres) for rain water pipes including filling the joints with approved adhesive complete .as per drawing and HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing m.s.holder bat clamps of approved design to C.I. or S.C.I pipes embeded in and including cement concrete blocks 10 x10x10 cm of 1:2:4:mix (1 cement :2 sand: 4 stone graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the wall etc., 100 mm diametre for C.I. pipe as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing angle iron door,window,clerestory window frame manufactured from steel iron section of 40X40X6 mm,thickness including hinges jamb,lock jamb,beed and if required angle thrashold of mild steel angle 50X25 mm welded or rigidly fixed by mechanical means,lugs with split end tails to each jamb including steel butt hinges 2.5 mm thick with provision for locking arrangement and shock absorber as specified and applying a coat of approved steel primer after preteatment of the surface as directed by Engineer-in- Charge as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing steel glazed doors,windows and ventilators of standerd rolled steel sections,joints mitred and welded with 16x3.15 mm lugs 10 cm.long embedded in cement concrete blocks 15 cmx10cmx10cm size of 1:3:6(1 cement:3 sand:6 graded stone aggregate 20mm nominal size)or with wooden plugs and screws or rawl plug and screws or with fixing clips or with bolts and nuts as required and iron fittings,including providing and fixing of glass panes with glazing clips and special metal sesh putty of approved make complete including applying a priming coat of red lead paint. Fixed steel windows as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Fixed steel windows
Side Hung Windows
Top Hung ventilators
Providing and fixing M.S. channels in doors, windows frames, manufactured from M.S. channels section of size (75 x 40 mm), M.S. flat, 75x4 mm combination as per design drawing including hinges, jambs, beed and if required, angle thrashold of mild steel angles, lugs with split end tails to each jamb including steel nut hinges 2.5 mm thick with provision for locking arrangement and shock observer and specified and applying a coat of approved steel primer after pretreatment of the surface as directed by Engineer-in- Charge as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing and fixing angle iron cupboard frames manufactured from M.S.Angle iron section 25X25X5mm thickness including hinges jamb,lock jamb,beed and if required angle thrashold of mild steel angle 25X25 mm welded or rigidly fixed by mechanical means,lugs with split end tails to each jamb including steel butt hinges 2.5 mm thick with provision for locking arrangement and shock absorber as specified and applying a coat of approved steel primer after preteatment of the surface as directed by Engineer-in- Charge as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Steel work welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position & applying a priming coat of red lead paint in gratings framed guard bars, ladders, railing, brackets & similar works as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
In gratings framed guards bars, ladders, railing, brackets and similar works.
Providing & fixing moulded hand rail of mild steel hollow pipe 50mm ( fifty milimeter )dia welded in straight length over mild steel flat at top of vertical balusters including one coat of red oxide priming coat complete (mild steel flat & balusters of railings shall be measured & paid separately )as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Painting two coats ( excluding priming coat) on new steel & other metal surfaces with enamel paint brushing to give an even shade including cleaning the surface of all dirt, dust & other foreign matters, Enamel paint other than white as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Applying priming coat over new wood & wood based surfaces after & including preparing the surface by thoroughly cleaning oil, grease, dirt & other foreign matter, sand papering & knotting, Ready mixed paint brushing wood primer pink as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Painting two coats(excluding priming coat) on new wood and wood based surface with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter,sand papering & stoping with enamel paint other than white as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
15mm cement plaster in single coat on the rough side of brick/ concrete/ stone walls for interior plastering upto floor all level including arrises, internal rounded angles,chamfers and/or rounded angles not exceeding 80 mm in girth & finished even & smooth in cement mortar 1:6 ( One cement : six sand ) as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
15mm cement plaster in single coat on fair side of brick/ concrete/ stone walls for interior/extererior plastering upto floor all level including arrises, internal rounded angles,chamfers and/ or rounded angles not exceeding 80mm in grith & finished even & smooth in cement mortar 1:6 (One cement :six sand ) as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
White washing with lime on undecorated surfaces of ceiling and/or sloping roofs, two coats to give an even shade including thoroughly brooming the surface to reomve all dirt, dust, mortar dirt and other foreign matter as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Distempering ( two coats ) with oil bound Nerolac or its equivalent washable distemper of approved brand & manufacture & of required shade on un-decorated wall surfaces to give an even shade over & including a priming coat with distemper primer of approved brand & manufacture after thoroughly brushing the surface free from mortar droppings & other foreign matter & also including preparing the surface even & sand papered smooth. Priming coat with distemper primer as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on decorated wall surfaces (one coat) to give an even shade after thoroughly brushing the surface to remove all dirt, loose or softened paint as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6 ( One cement : three sand : six graded stone aggregate 20mm (twenty milimetres) nominal size ) as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Providing under layer for plinth protection of 75mm (seventy five milimetres) thick ( unconsolidated )bed of dry brick/ stone aggregate 40mm (forty milimetres) nominal size with rammed & consilidated & grouted with fine sand including preparation of ground as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
Constructing course rubble hammer dressed " U" shape open surface drain with side wall 15 x 22 cm (fifteen into twenty two centimetres) in cement mortar 1:6 (One cement : six sand ) & inside plastering with cement plaster 1:3 ( One cement : three sand ) including earth work & laying 10cm (ten centimetres) cement concrete in 1:5:10 (One cement : five sand :ten graded stone aggregate 40mm (forty milimetres) nominal size ) & 7.5 cm (seven point five centimetres) cement concrete 1:2:4 ( One cement : two sand : four graded stone aggregate of 20mm (twenty milimetres) nominal size ) & finished with a floating coat of neat cement complete as per standard design as per HPPWD specification 1990 voume-I including carriage of all labour equipement and material to various location through all leads,lifts & other incidental charges complete as per entire satisfaction of the Engineer-in-Charge.
hement
SATISH KUMAR
Nikhil
Gurmeet Singh
SANCHIT GOEL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .