| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | ₹29.2 L Quoted ₹29.9 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹30.9 L+₹1.0 L (3.41%)Rejected-Finance | ₹30.9 L+₹1.0 L (3.41%) | L2 | Rejected-Finance Not being lowest tenderer |
| 3 | L3₹34.5 L+₹4.6 L (15.3%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | ₹34.5 L+₹4.6 L (15.3%) | L3 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Aug 2022, 6:00 pmClosed
GE RANIKHET
GE MES RANIKHET
PETTY REPAIRS INCLUDING DAY TO DAY MAINT WORKS TO BR AND EM FITTINGS AND FIXTURES IN MD AND OTM ACCN AND REPAIR REPLACEMENT OF STREET LIGHT FITTINGS MCCB LT OVER HEAD UNDER GROUND LINE INCLUDING EXTERNAL WATER SUPPLY FITTIGNS AND PIPE LINE AT HALDWAN
2022_MES_536806_1
GE/RKT/39 OF 2022-23
Open Tender
Civil Works
Works
240 days
Haldwani, Ranibagh, KamolaandKathgodam under GE Rkt
As per NIT
6 documents required · 6 mandatory
₹500
GE RANIKHET
₹70,000
15 Sept 2022
9 Jul 2022
15 Aug 2022
9 Jul 2022
13 Aug 2022
25 Jul 2022
Amount
BOQ ( Sch 'A') B/R & E/M items Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of Haldwani, Kamola and Ranibagh area under GE Ranikhet of water supply nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES onward main pipe line to OH PVC tank and OH PVC tank to internal bib tap including socket, nipple, elbow, tee etc complete repairs to the extent by removing connections from the system, removing faults in pipe line, tap including providing of petty stores such as insulation taflon tap and connected items of appropriate size and length as required to rectify the fault with regard to the compliant lodged and refixing of fittings, fixtures to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users complete all as sepcified and directed. Note : (i) Complaint register will be produced on daily basis to concerned JE and Engr-in-charge. (ii) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’/BOQ. (iii) All the complaint(s) received will be lodged & rectified by the contractor's rep and will have to maintain a proper record as directed in complaint register and in complaint slip. (iv) Complaint slip and complaint register will be provided by the contractor without any extra cost to department. (v) If contractor fails to attend the complaints in 48 hours, a recovery of Rs 300/- per complaint shall be recovered from the contractor. (vi) Any misc items required viz M Seal, screws, washers, nails etc in the work shall deemed to be included in the respective item of repair and nothing extra shall be paid on this account.
Taking up or down existing GI steel water tubing of any grade 25mm bore including all fittings and accessories from open surfaces, re-threading the old threds, cutting, welding work, etc as requried and re-fixign the same after necessary repair works, etc as required, with and including new GI fittings (such as bends, elbows, tees, connections, short pieces, bolts, nuts, unions, caps & plugs etc.) and accessories as reqd in new or old position including necessary excavation and earth works in any type of soil complete all as spceified and directed.
All as per item No 2 above but bore of pipe 20mm.
All as per item No 2 above but bore of pipe 15mm.
S&F in repairs and laying GI steel water tubing 15mm dia (bore), medium grade with and including all GI fittings, fixed to walls, ceiling or laid in floors or in any other situtation complete all as specified and directed.
All as per item No 5 above but 20mm dia (bore)
All as per item No 5 above but 25mm dia (bore)
S&F in repairs 15mm dia (bore) GI socket medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI socket medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI elbow medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI elbow medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI union medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI union medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI Tee medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI Tee medium grade complete all as specified and directed.
S&F in repairs 15x20mm dia (bore) GI socket reducer medium grade complete all as specified and directed.
S&F in repairs 20x25mm dia (bore) GI socket reducer medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI nipple and 25mm long medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI nipple and 50mm long medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI nipple and 75mm long medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI nipple and 100mm long medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI nipple and 25mm long medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI nipple and 50mm long medium grade complete all as specified and directed.
S&F in repairs 15mm dia (bore) GI tank nipple medium grade complete all as specified and directed.
S&F in repairs 20mm dia (bore) GI tank nipple medium grade complete all as specified and directed.
S&F in repairs 25mm dia (bore) GI tank nipple medium grade complete all as specified and directed.
S&F in repair 15mm dia ball valve high presure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe & fixed (minimum weight 15mm dia - 142gm) complete all as specified and directed.
S&F in repair 20mm dia ball valve high presure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe & fixed (minimum weight 20mm dia - 210gm) complete all as specified and directed.
S&F in repair 25mm dia ball valve high presure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe & fixed (minimum weight 25mm dia - 455gm) complete all as specified and directed.
S&F in repairs 15mm dia bib tap standard of PTMT, any colour, high presure, screwed for iron pipe & fixed (minimum weight 15mm dia - 90gm) complete all as specified and directed.
S&F in repairs PVC water tank top cover suitable for 500/1000 litres capacity including necessary locking devices complete fix to existing water tank complete all as specified and directed.
S&F 50mm dia CP waste fitting brass chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end based in red lead cement complete all specified and directed.
S&F in repairs 32mm dia PVC waste pipe of cup with overall length of pipe 900mm complete all as specifed and directed.
S&F in repairs 40mm dia PVC waste pipe of cup with overall length of pipe 900mm complete all as specifed and directed.
S&F in repairs 50mm dia PVC waste pipe of cup with overall length of pipe 900mm complete all as specifed and directed.
S&F in repairs 15mm dia PVC connections, 450mm long with PTMT nuts complete all as specified and directed.
S&F in repairs 15mm dia PVC connections, 600mm long with PTMT nuts complete all as specified and directed.
S&F in repairs aluminium grip (hot & cold) connection pipe for basin mixer/geyser/hot & cold connections hose pipe of length 600mm complete all as specified and directed.
Supply & fixing PVC Flushing Cistern 10 litre capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of MS Brackets,CP flush bend including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed.
S&F in repairs plastic seat cover coloured suitable water closet pedestal pan, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges devices complete all as specified and as directed
S&F in repairs stainless steel grating 100mm dia complete all as specified and as directed
S&F in repairs stainless steel grating 125mm dia complete all as specified and as directed
S&F in repairs glass shelf of size 450x125mm and 6mm thick with ABS bracket chromium plated, bracket guard and stainless steel railing complete all as specified and as directed
S&F in repairs corner glass shelf of size 300x600mm and 6mm thick with ABS bracket chromium plated, bracket guard and stainless steel railing complete all as specified and as directed
S&F in repairs soap dish chromium plated brass complete all as specified and directed.
S&F in repairs peg set of six complete all as specified and directed.
S&F in repairs Brass chromium plated shower rose 100mm size with shower arm, including fixing to steel pipe or union complete all as specified and directed.
Supply& Fixing tubular towel Rail CP Brass, chromium plated D type with CP Brackets, 600 mm long between flanges complete all as specified and directed.
Supply & fix Hand Shower (health faucet) CP Brass 15 mm bore with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back Flow Preventer) as approved by the GE. Make- Jaquar or its equivalent approved make complete all as specified and directed.
S&F in repairs 15mm dia bib taps CP Brass with Capstan head, screwed down, screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F in repairs 15mm dia bib taps, fancy type long body chromium plated cast copper alloy with crutch or butterfly handle complete all as specified and directed.
S&F in repair Angle Cock, 15mm fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair Fancy type Pillar Tap 15mm dia cast copper alloy with capstan head chromium plated fancy type, screwed down high pressure, with or without letters ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair brass Chromium plated Basin Mixer valve hot and cold screwed down for iron pipe complete all as specified and directed. .
S&F in repair Brass CP Wall mixer for mixing hot & cold water (3 in 1) screwed down for iron pipe and fixed bore of pipe 15mm complete all as specified and directed.
S&F Ball Valves Brass, 15mm dia, quarter turn, femaled threaded, screwed both ends for iron pipe for unions, complete all as specified and directed.
S&F Ball Valves Brass, 20mm dia, quarter turn, femaled threaded, screwed both ends for iron pipe for unions, complete all as specified and directed.
S&F Ball Valves Brass, 25mm dia, quarter turn, femaled threaded, screwed both ends for iron pipe for unions, complete all as specified and directed.
S & F in repair Aluminium handle, cast type anodized 100mm size complete all as specified and directed.
S & F in repair Aluminium handle, cast type anodized 150mm size complete all as specified and directed.
S & F in repair 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repair Butt Hinges medium weight cold rolled mild steel of 100mm size complete all as specified and directed.
S&F in repair Stainless Steel butt hinges medium weight of 100mm size complete all as specified and directed.
S&F in repair Butt Hinges medium weight cold rolled mild steel of 75mm size complete all as specified and directed.
S&F in repair MS mortice lock vertical type, 4 lever of size 100mm complete all as specified and directed.
S&F in repair door closer aluminium extruded section hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed.
S&F in repair Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F in repair 150 mm overall length floor stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed
S&F in repair Aluminium alloy, anodised, sliding door bolt with haps, staple (bolt type) and fixing clips with sheet, cast and extruded section and fixing bolt and sliding bolt of extruded sections or cast aluminium alloy and fixed 250 mm long complete all as specified and as directed.
Supply & Fixing in repair 4.8 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square exc. 0.5 sqm in each pane complete all as specified and directed.
Supply & Fixing in repair 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
Supply & Fixing in repair 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
Taking down of existing aluminium door of any description including renewal of unserviceable parts and refixing in the same opening complete all as specified and directed. Note :- Wire mesh and glass will be measured and paid separately.
Taking down of existing aluminium windows of any description including renewal of unserviceable parts ( rubber beeding, handle, wheel etc) and refixing in the same opening complete all as directed. Note :- Wire mesh and glass will be measured and paid separately.
S&F in repair aluminium sheet powder coated of thickness not less than 5mm thick to be in sealed as panel in aluminium door including fixing complete all as specified and directed.
S&F in repair decorative stainless steel tubular curtain rail of 25mm dia including six nos curtain ring per running mtr and one number of brackets on each end and one no of globe on each end of the rod per opening of door / window complete all as specified and directed.
S&F in repair brass spindle suitable for 15mm dia CP tap, CP stop cock short body/ long body and CP pillar cocks & Brass bib tap complete all as specified and directed.
S&F in repair Push to open Magnetic Catches for kitchen cabinet doors complete all as specified Make Hettich or its equivalent approved make complete all as specified and directed.
S&F in repair rotational moulded polythene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
S&F in repair rotational moulded polythene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
Surface dressing n.exc 15 cm deep including in any type soil including taking out all sapling shrubs, bushwood, undergrowth, roots, and trees n. exc 30 cm girth and removing to a distance n.exc 100 m from starting point complete all as specified and directed. (The area is to be carried out in and around,structches viz transformes, HT and electric poles over head reservoirs, around power house and pump house and other E/M installation at Haldwani & Ranibagh.
Excavation in trenches not exc, 1.5m wide and not exc 1.5m deep and getting out complete in hard/dense soil for taking out and laying of CI/GI pipe and forming bottom surfaces of trenches to reqd slope/ gradient complete all as specified and directed.
Returning, fillingin, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated surplus materials (soils) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Taking up or down 50mm dia steel tubing of any grade including all GI fitting laid in trenches or on open surface and connections for relaying or removal complete all as specified and directed.
All as per item No 87 above but 40mm dia.
All as per item No 87 above but 32mm dia.
All as per item No 87 above but 25mm dia.
All as per item No 87 above but 20mm dia.
All as per item No 87 above but 15mm dia.
Re-fixing of 50mm dia bore old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from item 87 will be reused.
All as per item No 93 above but 40mm dia Note :- Serviceable GI tubing retreived from item 88 will be reused.
All as per item No 93 above but 32mm dia Note :- Serviceable GI tubing retreived from item 89 will be reused.
All as per item No 93 above but 25mm dia Note :- Serviceable GI tubing retreived from item 90 will be reused.
All as per item No 93 above but 20mm dia Note :- Serviceable GI tubing retreived from item 91 will be reused.
All as per item No 93 above but 15mm dia Note :- Serviceable GI tubing retreived from item 92 will be reused.
Supply and laying 80mm dia GI water tubing medium grade with and including all GI fittings (such as bend, elbow, tees, connectons, short pieces, bolts, nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed
All as per item No 99 but 50mm dia
All as per item No 99 but 40mm dia
All as per item No 99 but 32mm dia
All as per item No 99 but 25mm dia
All as per item No 99 but 20mm dia
All as per item No 99 but 15mm dia
M&L for making good the leaking of upto 150 mm bore GI/CI pipe lines by welding all around the pipe, thickness of metal to be welded exc 9 mm but n exc 20 mm respectively including all necessary excavation and earth work in any soil including removal of old joints etc complete all as specified and directed. Loc : Pump House, Haldwani, Ranibagh & Kamola.
Taking out sluice valve suitable for 150 mm bore pipe from valve pit for re-facing & re-grinding and re-fixing, including all jointing material such as nut, bolts, washers, rubber gasket/packing 6 mm thick, including glan packing etc and as required at site complete all as specified and directed. Loc : Pump House, Haldwani, Ranibagh & Kamola
All as per item No 107 above but for 100mm bore
All as per item No 107 above but for 80mm bore
Taking out old unserviceable sluice valve from valve pit or vertical line of overhead tank valve and supply, Install, commissioning and testing of 150 mm size sluice valve of cast iron body flanged & drilled conforming to IS-14846, PN-1.00 with stainless steel spindle including all accessories such as nuts, bolts, washers & fibre/rubber gasket as required at site complete all as specified and directed.
All as per item No 110 above but 100mm size sluice valve
All as per item No 110 above but 80mm size sluice valve
Removing water meters, any pattern from 20 mm bore of pipes by unscrewing union, fitting, unions with screw plugs, or inserting short length or tubing screwed both ends so as to maintain supply all as specified and directed.
M&L for de-watering of 100000 gallons capacity under ground water sump including removing fungus, scales, slurry etc from the inside wall of the sump, taking out sludge, mud, clay deposited at the bottom of the sump and removing the same to a distance not exc. 50 mtr, washing the walls of the sump with water and chemical salt as bleaching powder etc and applying two coats of lime washing on all the internal surfaces of the tank and two coat of cement base paint on external surfaces of approved make and shade on all the outside surfaces of the tank and one coat of synthetic enamel paint over the iron/steel surfaces. The entire job is to be carried out all as specified and directed at Loc : Haldwani Note :- (i) The contractor shall write the date on which the tank is cleaned with white synthetic enamel paint in bold letter and back ground shall be painted with black synthetic enamel paint on wall of UG Tank. (ii) Rate quoted by the contractor shall deemed to be included the same and no extra payment shall be made on this account.
All as per item No 114 above but for 50000 gallons capacity, loc at Haldwani
M&L for cleaning of RCC overhead tank of capacity 10000 gallons on 15 Mtr staging from inside, extraction of dust/sand/mud/algee deposits, making it free from algee growth by scrapping and washing with water and cleaning outside surfaces and area surrounding of the tank including drains etc. and applying two coats of lime washing on all the internal surfaces of the tank and two coat of cement base paint on external surface including staging of tank of approved make and applying one coat of synthetic enamel paint over iron and steel surfaces. The entire job is to carried out all as specified and directed at loc : Ranibagh/Kamola Note :- (i) The contractor shall write the date on which the tank is cleaned with white synthetic enamel paint in bold letter and back ground shall be painted with black synthetic enamel paint on wall of overhead Tank. (ii) Rate quoted by the contractor shall deemed to be included the same and no extra payment shall be made on this account.
All as per item No 116 above but 25000 gallons capacity, loc at Haldwani
All as per item No 116 above but 50000 gallons capacity, loc at R & O area Haldwani
Taking out old unserviceable cast iron non return valve of any type and size for replacement with and including supplying, fixing, testing and commissioning non return valve suitable for 100 mm bore pipe (suction line) both ends flanged including nuts, bolts, gasket and washer for Sump and Pump house bldg complete all as specified and directed. Loc : Pump House Haldwani, Ranibagh & Kamola
Material & Labour for repair and overhauling of elect motor 30 HP capacity installed with Pump set at pump house, Haldwani comprising of the following works :- (a) Dismantling of 30 HP electric motor 3 phase, 440 volts from foundation and taking away local workshop and transporting back the same after repairs. (b) Opening of motor winding, cutting of burnt coils and cleaning of slots complete all as specified and directed. (c) Applying one coat of red oxide primer, fixing of packing with Pnumax paper and green sheet of glass cloth, rewinding with suitable gauge of super enamelled insulated wire (Appx qty- 25 Kg) (d) Making suitable Star/Delta connections for three phase wiring with 6 Sqmm x 6 run (Appx 24 RM) of FRLS wire incl PVC pipe and pin type lugs complete all as specified and directed. (e) Varnishing with doctor bake varnish, during backtrol and heating properly complete all as specified and directed. (f) Replacement of unserviceable rubber star coupling and providing new pin bush coupling complete all as specified and directed. - 01 No (g) Repair of main shaft of pump. (h) Replacement of Pump bearing of suitable sizes and fillup greesh for lubrication complete all as specified and directed. - 02 Nos (j) Repalcement of imppellers suitable size. - 02 Nos (k) Replacement of pump bushes of suitable size. (l) Replacement and repair of Gland packing, greasing to bearigns. Notes :- Standby electric motor of 30 HP should be provided by contractor at the site without any extra cost.
All as per item No 120 above electric motor of capacity 10 HP installed at MES pump house Haldwani complete all as specified and directed.
All as per item No 120 above electric motor of capacity 7.5 HP installed at Ranibagh complete all as specified and directed.
Material & Labour for servicing of silent DG set capacity 250 KVA (Three phase diesel engine driven Generator set) at Tech Area, 301 Avn complete all as specified and directed, comprising of the following works :- (a) Overhauling of Self starter assembly including required defective part. (b) Replacement of engine oil filters - 02 Nos (c) Replacement of diesel filters - 02 Nos (d) Replacement of Air filter - 01 No. (e) Replacement of engine oil of required cap with specified grade - 25 Ltr (Approx) (f) Replacement of alternator carbon bushes. (g) Fan belt as per sample - 03 Nos (h) Replacement of alternator bearing of required size - 02 Nos (j) Replacement slipering assembly - 01 No (k) Replacement of coolant of required cap - 05 Ltr (Approx) (i) Replacement of Battery 12 V, 150 Ah - 02 Nos (m) Replacement of proximate coolant sensor complete with wiring connection - 01 No (n) Replacement of LOP (Low oil pressure) indicator sensor - 01 No (o) Replacement of door lock - 04 Nos (p) Replacement of fuel tank cap with lock - 01 No (q) Replacement of ABR card/circuit board/plate - 01 No
Material & Labour for servicing of 160 KVA ,(Three phase diesel engine driven Generator set) installed at MES Pump House Haldwani complete all as specified and directed, comprising of the following works :- (i) Overhauling of Self starter assembly including required defective part (ii) Replacement of engine oil filters - 02 Nos (iii) Replacement of diesel filters - 02 Nos (iv) Replacement of Air filter - 01 No (v) Replacement of engine oil of required cap with specified grade - 25 Ltrs (Approx and as reqd on site) (vi) Replacement of alternator carbon bushes (vii) Fan belt as per sample - 03 Nos (viii) Replacement of alternator bearing of required size - 02 Nos (ix) Replacement slipering assembly - 01 No (x) Replacement of coolant of required cap - 05 Ltr Approx (As qty required on site). (xi) Replacement of unserviceable battery 12 V, upto 150 Ah - 02 Nos
All as per item No 124 above but 30 KVA at Ranibagh complete all as specified and directed.
All as per item No 124 above but 25 KVA at Kamola complete all as specified and directed.
All as per item No 124 above but 7.5 KVA at Signal Centre Haldwani complete all as specified and directed.
Supply only Calcium Hypo Chlorite 65%-70% Chlorine content in granular and tablet form disinfectant for water treatment in 45 Kg Drums as mentioned in latest approved list of E-in-C Br New Delhi and Chief Engineer Central Command complete all as specified and directed.
M&L in repairs of adjustable high pressure dosing single phase pump 0-100 PSI power : 230 VV, 50 Hz, RPM -44 horse power : 1/30 with and including the following repair of accessories at Pump House Haldwani :- (a) Replacement of Lead tubing. (b) Replacement of Connection Nuts (c) Replacement of Injection check valve. (d) Replacement of Clay weight. (e) Replacement of ferrul end of dosing pump. (f) Repair of mixer motor 0.5 HP. (g) Repair of injector pump.
M&L in repairs for opening of CI sluice valve of 150 mm size any type for replacement of defective spindle with stem and providing new spindle with stem made of stainless steel duly machine threaded, heat treated and shaped including cast iron hand wheel and making good the stuffing box with suitable size of gland packing and greasing at Haldwani & Ranibagh complete all as specified and directed.
All as per item No 130 above but 100mm size sluice valve
All as per item No 130 above but 80mm size sluice valve
Excavation in trenches by manually or mechanical method n.exc. 10 Sqm on plan or exc. 1.5m in width, depth of trench upto 3.0m in deep for foundation etc. in any type of soil including taking out old filler material from the mild steel pipe joint including cleaning of joints and making the joints completely water tight and air tight by means of lead joint & filler material to the entire satisfaction of Engineer in charge including retuning, fillingin in any type soil, to be done after joints are sealed complete all as specified and directed. Note :- The rate quoted by the contractor shall deemed to be included all T & P and material and nothing extra shall be paid on this account.
M & L in repairs for complete dismantling of unserviceeable water level indicator of UG Sump & RCC OH tank with and including M&L for replacing the same indicator made out of angle iron frame 25x4mm, MS sheet 1.6mm steel. rope of suitable gauge/size 4mm, MS indicator of suitable size, copper float valve of 230mm dia, MS pully for smooth operation of steel rope including painting with on coat ofsynthetic enamel paint the complete frame and marking the scale suitable for the 0.5/1.0 lakh gallons capacity at Haldwani & Ranibagh
M & L for repair and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 30 HP at Pump house Haldwani complete all as specified and directed.
M & L for repair and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 10 HP at Pump house Haldwani complete all as specified and directed.
Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of Haldwani, Kamola and Ranibagh area under GE Ranikhet of electrification nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES onward KWH meter in respect of main distribution board having switch fuses, MCB distribution board in sheet metal enclosure, point wiring, fixture for light/ Fan/bell/light or power sockets complete repairs to the extent by removing connections from the system, removing faults in wires, batten, conduit, sunk boxes, junction boxes, main switches, MCBs/DBs utility light fittings, FTL light fitting any wattage lamp, holders, AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty materials such as insulation wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as specified and directed.at site. Note : (i) All the complaint(s) received will be lodged & rectified by the contractor's rep and will have to maintain a proper record as directed in complaint register and in complaint slip. (ii) Complaint slip and complaint register will be provided by the contractor without any extra charge. (iii) Complaint register will be produced on daily basis to concerned JE and Engr-in-charge. (iv) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’/BOQ. (v) If contractor fails to attend the complaint in reasonable time. a recovery of Rs 300 per compaint shall be recovered from RAR/Final Bill. (vi) Contractor shall employee having ITI or equivalent certificate from Govt. Institution with 4 year experience in the said field.
Supply & Fixing in repairs lamp holder (dome type) PVC insulated body with back plate for angle/battern fitting complete all as specified and directed.
Suppy & Fixing in repairs switch piano flush type single pole, one way 5 Amp complete all as specified and directed.
Supply & Fixing in repairs switch piano, flush type single pole 15 Amp complete all as specified and directed.
Suppy & Fixing in repairs switch piano flush type single pole, two way 5 Amp complete all as specified and directed.
Supply & Fixing in repairs socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed.
Supply & Fixing in repairs socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
Supply & Fixing in repairs Modular switch socket outlet , 3 Pin, 15 Amp flush type universal complete all as specified and directed.
Supply & Fixing in repairs modular switch socket outlet 3 pin 5 Amp flush type complete all as specified and directed.
Supply & Fixing in repair modular switch socket combination 2 in 1,3 Pin, 6 and 16 Amp flush type universal complete all as specified and directed.
Supply & Fixing in repairs switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
Supply & Fixing in repairs Bell push, flush type , 5 Amp complete all as specified and directed.
Supply & Fixing in repairs steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
Supply & fixing in repairs Bell (Ding dong type) AC 230 volts, 50 Hz single pole complete all as specified and directed.
Supply & Fixing in repairs ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed.
Supply and fixing in repairs of 6 Amp one way switch, 1 Module rating of modular type ,white polycarbonate, switches, sockets, fan regulator suitable for 250V, AC, 50Hz.Electrical supply complete all as specified and directed.
All as per item No 152 above but 6 Amp two way switch, 1 module
All as per item No 152 above but 6 Amp 2/3 pin combined socket shuttered, 2 module
All as per item No 152 above but Modular Switch 1 way 16 Amp, 1 Module
All as per item No 152 above but Modular socket 6A/16Amp, 2/3 pin combined, 2 Module
All as per item No 152 above but 6 Amp bell push switch modular type
All as per item No 152 above but steped type electronic fan regulator modular, 120W-2 module
M&L in repairs for PVC/Polycarbonate rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100 mm and 50 mm deep including fixed with screws and cup washers and taking down unserviceable switch board of any make and type including teakwood board etc complete and making good the disturbed surfaces with and including applying one coat of colour wash complete all as specified and directed.
All as per item No 159 above but 175 x 100 x 50 mm deep
All as per item No 159 above but 200 x 150 x 50 mm deep
All as per item No 159 above but 250 x 200 x 50 mm deep
Supply & Fixing in repairs 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Supply & Fixing in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Supply and fixing in repair LED T-5 lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.complete all as specified and directed. Make Havells cat pat LUMILINEBS20WLED865SPCWH or equivalent of phillips/wippro/Bajaj/Surya complete Note:- The Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing in repairs LED T-5 light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V, AC with driver holder and LED lamp including connecting up with three core flexible opper conductor cable of suitable size complete all as per specified and directed.
S & F in repairs LED light fitting 1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in make phillips/wippro/Bajaj & C&S . Note:- The Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing in repairs condenser oil filled/dry 2.5 mfd. complete all as specified and directed. Make- Usha/Asian/Elcap.
Supply and fixing in repairs condenser oil filled/dry 3.15 mfd. complete all as specified and directed. Make- Usha/Asian/Elcap.
Supply and fixing in repairs heating element upto 2000 watt tringular type/cap type (as required on site) for water heater/gyser all as specified and directed.
Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of Haldwani, Kamola and Ranibagh area under GE Ranikhet of water supply nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES for main/distribution pipe line to Over Head (OH) PVC tank like leakage of water/pipe line, valve, union, no water in tank, line blockage etc complete repairs to the extent by removing connections and refixing as existing from the main/distribution pipe line, removing faults in pipe line including providing of petty materials such as insulation taflon tape and connected item of appropriate size and length as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site. Note:- (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complaint register and in complain slip. (ii) Complaint slip and complaint register will be provided by the contractor without any extra charge. (iii) Complaint register will be produced on daily basis to JE and Engr-in-charge (iv) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’/BOQ. (v) If contractor fails to attend the complaints in reasonable time, a recovery of Rs 300 per complaint shall be recovered from RAR/Final bill.
M&L for mild steel work Fe-410-S grade channel or angle section etc in cross arms, bracing, supports,clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed with and including applying two coats of aluminium paint over a coat of red oxide primer including dismantling cross arms of mild steel channel or angle section etc complete all as specified and directed.
Supply and fixing pin type, porelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
Supply and fixing shakle type, porelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts in repair insulators suitable for working pressure in 1100 volts of height 75 mm and max dia 90mm alongwith galvanised steel fittings, section of straps in 31X3 mm and dia of bolts 12mm complete all as specified and directed.
M&L for MCCB 4 pole, 415 V adjustable typ,e 160 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L for MCCB 4 pole, 415 V adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L for MCCB 4 pole, 415 V adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L for MCCB 4 pole, 415 V adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L for MCCB 4 pole, 415 V adjustable type, 630 Amps with breaking capacity 50 KA complete all as specified and directed.
M&L for stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamp 50x6mm size, bolts, nuts, washers, galvanized steel stay rod 16mm dia and 1800 mm long , stay bow 400 x 14 mm galvanised steel plate 230 x 230 x 6 mm two numbers, thimbles, loop insulator of size 90 x 140 mm clearance hole 16 mm dia with and including necessary excavation and earth work in any type of soil, PCC 1:3:6 type C-2 as in foundation of stay assembly, disposal of surplus soil to a distance not exc. 50m with and including applying two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work including dismantling existing stay assembly etc complete all as specified and shown in electric plate No 1 and directed.
M&L for stringing, stretching and stengthening of over head conductor (ACSR) Weasel (6/1x2.59 aluminium and 1x2.59 steel) on existing LT steel tubular pole or RS joist LT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc complete all as specified and directed. Note:-If any break or damage of insulator occurs the same shall be replaced by the contractor at his own cost and no extra payment for the same shall be paid by the Government and unit rate quoted by contractor shall be deemed to included the same.
M&L for stringing, drawing of GI wire 4 mm dia on LT electric lines including binding, jointing and for guarding cradle made to shape hexagonal/rectangular or any shape fabricated etc complete all as specified and directed.
M&L for in replacement of anti climbing device spikes type fabricated out of MS bar (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole etc complete all as specified and directed.
M&L for in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15 cm size etc complete all as specified and directed.
Supply and fixing or passing through pipe, stranded conductor 6 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular etc all as specified and directed.
All as per item No 185 above but 10 Sqmm size
All as per item No 185 above but 16 Sqmm size
Supply , laying , connecting, testing and commissioning of 300 Sqmm 3.5 core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe and including making good the disturbed surfaces of road with using PCC 1:2:4 type B-1, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Note:-(Excavation, earthwork, sand cushioning and cable protection shall be measured and paid for separately.)
All as per item No 188 above but 150 Sqmm 3.5 core
All as per item No 188 above but 70 Sqmm 3.5 core
All as per item No 188 above but 50 Sqmm 3.5 core
All as per item No 188 above but 35 Sqmm 3.5 core
All as per item No 188 above but 16 Sqmm 2 core
Supply and fixing LED street light fittings 60 watt, 230 V, AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, average life of street light not less than 50000 hours, inluding clamps, nut, bots, bracket made of GI pipe light grade, 32mm dia, length not less than 1.5m, bent to shape for LED fitting for fixing of LED light on electric LT pole including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre and testing complete all as specified and directed. Make :- Havells cat pat no ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent cat part in make Philips, Wippro & Bajaj . Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing LED flood light 70 watt, 230 V, AC out door type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light not less than 50000 hours, including clamps, nut, bolts, bracket made of GI pipe light grade, 32mm dia, length not less than 1.5m, bent to shape for LED light fitting for fixing of LED light on electric LT pole including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre and testing complete all as specified and directed. Make :- Havells, Philips, Wippro, Bajaj .
M&L for Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 with and including excavation and earth work in any type soil, GI pipe light grade 32 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanized Iron/steel of size 75x75x 25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded crushed stone aggregate, reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost to Govt by the contractor.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, fillingin including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement).
Supply and laying unreinforced precast concrete cable cover class LV type I , flat, size 250x150x40mm complete all as specified and directed.
M&L for GI tubing light grade 80 mm bore for cable protection laid in trenches/fixed to wall, poles including MS flat iron, clamps,nuts, bolts, etc complete all as specified and directed.
Supplying, commissioning & testing of Time light distribution board/street light timer switch with anolog time switch with battery backup, 3P module, 24 hours program, programmabel 15 min, backup of 100 hrs, current capacity 16 Amp, with 1 changeover (1 CO) 40 Amp 3 pole/230V Analog time switch with enclosure system in mounting arrangement and tripping mechanism alongwith suitable capacity of control MCBs as per INDOASIAN Cat Part No. TL040ABO or its equivalent approved make of L&T, C&S & Havells complete all as specified and directed. Note : Contractor shall submit 1 year warranty of distribution board from manufacturer alongwith purchase voucher.
Supplying, commissioning & testing of Time light distribution board/street light timer switch with anolog time switch with battery backup, 1P module, 24 hours program, programmabel 15 min, backup of 100 hrs, current capacity 16 Amp, with 1 changeover (1 CO) 40 Amp 1 pole/230V Analog time switch with enclosure system in mounting arrangement and tripping mechanism alongwith suitable capacity of control MCBs as per INDOASIAN Cat Part No. TL040ABO or its equivalent approved make of L&T, C&S & Havells complete all as specified and directed. Note : Contractor shall submit 1 year warranty of distribution board from manufacturer alongwith purchase voucher.
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed.
All as per item No 205 above but cable of size 120 Sqmm to 150 Sqmm
All as per item No 205 above but cable of size 120 Sqmm to 150 Sqmm
M&L for preparation of old painted steel and iron surfaces of any description and applying painting to steel tubular LT poles with two coats of synthetic enamel paint upto 1.5 m height above from ground level/plinth block (in yellow, Red and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles including painting with synthetic enamel paint on cross arms, bracing, clamps etc and writing pole Nos with thick black synthetic enamel paint complete all as specified and directed.
M&L for stringing, stretching and stengthening of over head conductor (ACSR) Weasel (6/1x2.59 aluminium and 1x2.59 steel) on existing LT steel tubular pole or RS joist LT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc complete all as specified and directed. Note ;- (i) Cutting/trimming of tree branches all around the LT over head conductor of any span upto 1.5m away including removing the same shall deemed to be included in unit rate quoted by the contractor. (ii) If any barrage or damage to insulator occurs, the same shall be replaced by the contractor at his own cost without any extra payment to Govt.
All as per item No 209 above but Squirel (6/1x2.11 aluminium and 1x2.11 steel)
Supplying, installation, testing & commissioning of sub distribution board 4 way vertical TPN DB's suitable upto 100 Amp FP MCCB and single / three phase outgoing MCBs IP-54 protection double metal door factory fabricated from minimum 1.6 mm thick CRCA sheet wall mounting type in surface / recess powder coated 415V/250 Amps copper bus bar, earth and neutral bar with outgoing feeder complete in all respect, DB's shall be original factory fabricated of approval make complete all as specified and directed. The rates shall deemed to be included all incommer and outgoing circuit breaker as under : - Incommer : - MCCB of capacity 100 Amps FP 415 Volts 50 Hz having rapturing cap 35 KA. Outgoing : MCB DP-10-40 Amp -06 Nos Bus bar - Copper busbar of capacity 200 Amps. Make : L&T cat pat No DBVTL00454 and its equivalent cat part in make : Havells, INDOASIAN, C&S
Supplying and installing, commissioning of cubical factory made LT Panel made out of angle iron 65mmx65mmx6mm on all side welded to 3.0 mm thick CRCA steel sheet with openable shutters on both sides (Front and rear) having locking arrangement totally enclosed weather proof, outdoor type, Powder coated suitable for 440 volts, 3 phase, 4 wire, 50 cycles, Aluminum bus bar of capacity 400 Amps, AC supply, electrically connected as per norms,CPRI approved of Make : Havells, INDOASIAN, L&T, C&S.and fitted with following :- (a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (01 No for Incoming) Make : Havells, C&S, L&T, and INDOASIAN. (b) 3 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 Nos (Outgoing). Make : Havells, C&S, L&T, and INDOASIAN. (c) MCCB, 4 pole, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA -02 Nos. (Outgoing) Make : Havells, C&S, L&T, and INDOASIAN. (c) MCB, TPN- 25 Amps , 50 Hz, 415 V with rupturing capacity 16 KA -02 Nos. (Outgoing) Make : Havells, C&S, L&T, and INDOASIAN. (d) Digital voltmeter-01, Ammeter-01. Make : Havells, C&S, L&T, and INDOASIAN. (e) LED indicator lamp –01 No (set of three) Note : (i) The height of panel should be 0.60 mtr from ground level with PCC 1:3:6 type C-2 foundation and spare space in bus bar for fittings one MCCB in future purpose. (ii) Each MCCB's having seperate enclosures.
Supply and Fixing pole mounting box / junction box made out of 1.6mm thick MS CRCA sheet / fiber sheet of size 230 x170 x 105 mm complete suitable for three phase connection with clamps of flat iron/GI of size 25 x 4 mm including suitable size nut, bolts, washers etc to fix on pole and provide with hinged door and locking system and all painted with two coats of synthetic enamel paints over one coat red oxide paint and comprising of the following :- (i) Aluminium bus bar 150mm long size 20 x 50 mm fixed on four Nos porcelain insulator each busbar provided with four Nos of Nuts, bolts, washer for incoming and out going cable. (ii) MCB SP 230V 5 to 32A, 10 KA – 1 No.
Supply and Fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm 2 Core from junction box to street light pole to street light complete all as specified and directed.
Supply and Fixing 20mm bore PVC pipe having for cable protection in pole from junction box to street light fittings complete all as specified and directed.
M&L for in repairs for LT under ground cable fault locating instrument suitable to locate and pin point fault in LT cables and make the cable in operational condition including provision of jointing material which is required on site such as cable joint kit, excavation and earth work in trenches in any type soil upto depth of cable, returning filling and removing the extra material on site after completion of work complete all as specified and directed.
Trimming of trees all as along the LT line in such a way that there is clear distance of 3.00 mtr between tree and electric line. The work will be executed to the entire satisfaction of Engineer-in-charge irrespective of the size of the tree branches etc complete all as specified and directed. Note :- (1). Tree branches will be left as it is, the wood belong to cantt board/DO. They will be responsible for the wood. (2) The Contractor will be employ sufficient labour to complete the full one job with in above 15 days (3) Contractor shall take all safety measures and will be responsible for any type of accident while trimming the trees. (4) The Contractor's superviser will take proper shut down for MES Installation before starting the work and clear it before resuming power supply, however full assistant will be provided by MES staff.
M & L for Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
M & L for Test terminal block made of gun metal or phosphorus bronz size 75 x 75 x 25 mm drilled and screwed including 3 nos 8 mm dia 25mm long hexagonal head screw complete all as specified and directed.
S&F Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground level complete all as specified and directed.
kumar automobiles
JAGAT POWER ELCTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .