Assistant Executive Engineer Minor Irrigation Sub
Office of the Assistant Executive Engineer Minor Irrigation Sub Division Kannur (PO) Civil station Kannur 670002
LAC-ADS-GENERAL-MLA ADS 2023-24 Renovation of Payyattam Kulam at Irinave in Kalliasseri Panchayath in Kalliasseri Constituency- Electrical Work-Electrical works-General Electrical Work
2026_Irrig_850833_1
PWD/BLDG/EST/1340/2026_6_1_1
Open Tender
Electrical Works
Item Rate
Kalliassery panchayath
Please refer Tender documents.
15 documents required · 15 mandatory
₹555
Yes
₹3,811
Yes
14 May 2026
14 May 2026
25 May 2026
14 May 2026
22 May 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical Maintenance Work | |||||
| 1.001 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | - | each | - | - |
| 1.002 | OD285212/2025-2026:Supply and fixing Time switch 240V AC DIN/BASE mounting(L&T J648B1-Analog version) in the existing enclosure and giving connection as required. | - | each | - | - |
| 1.003 | OD285182/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum dimension 315mm width and 545mm height, BIS certified with a body and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on tothe optical unit , separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP 66 optical & IP 65 control gear compartments . Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 100lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor > 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV . ( / KESSLEC RILA 50W WW/ or equivalent K lite fittings | - | each | - | - |
| 1.004 | OD304573/2025-2026: 30W RGBW, BIS certified with a flat toughened glass protector (IK8), body of high pressure die cast aluminium, separate optical & control gear compartments (IP67). Several optical options for symmetric light distribution with beam angles narrow, medium, wide, elliptical. This RGBW Flood is an excellent choice for outdoor architectural lighting applications. Bracket suitable for a wall, ground or high mast mounting and pre-cabled as required. Overall luminous efficiency of 50lm/W at correlated colour temperature (CCT) of RGBW colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 KV. CAT REF: KESSLEC PIROT 30W RGBW/ eqvnt | - | each | - | - |
| 1.005 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm | - | metre | - | - |
| 1.006 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.2 X 6 sq. mm (19mm) | - | set | - | - |
| 1.007 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | - | metre | - | - |
| 1.008 | OD285249/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height above the ground level made out of GI, tubular pole having two section section, bottom section of minimum 900/1000mm with base dia of 114mm and upper section of minimum 2300/2000mm with minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shall have base plate of dimension 200x200x12mm/round minimum 200mm including minimum16mm diameter 4 numbers foundation bolts of 450mm bolt length, 200mm pitch circle diameter manufactured from special steel along with nuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The control gear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 way terminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and provision for earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph. Pole should hot dip galvanized to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given marine coating. The complete system should be hot dipped Galvanised. (Crompton Deco/K lite COLOMBIA/Kesslec ECO). | - | each | - | - |
| 1.009 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | - | cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BDele.pdf
Tender Documents • 2.54 MB
BOQ_1437624.xls
BOQ • 0.31 MB
MOMele.pdf
Additional Documents • 0.20 MB
SPECIFICCONDITIONele.pdf
Additional Documents • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .