Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹37.7 L+₹64,900 (1.75%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹38.3 L+₹1.2 L (3.25%)Rejected-Finance 3 358 PALLICKAL KRISHNALAYAM PAKALKURI PO VARKALA THIRUVANANTHAPURAM KERALA 695604 | VARKALA | THIRUVANANTHAPURAM | KERALA | 695604 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹42.0 L+₹4.9 L (13.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹44.1 L+₹7.0 L (19.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
9 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004
PROVISION OF AIR CONDITION FOR MH 60R CELL AND AIR TECHNICAL DEPARTMENT INS GARUDA
2022_MES_524526_1
8818/E8
Open Tender
Civil Works
Item Rate
150 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹91,000
Yes
2 Jul 2022
17 May 2022
11 Jun 2022
17 May 2022
9 Jun 2022
27 May 2022
17 May 2022 - 26 May 2022
60 days
Amount
Supply, install, testing and commissioning of split type tower air conditioning unit 3.8/4.0 TR capacity complete with cordless remote control, eco friendly refrigerant gas, 11400/12000 K Cal/ Hr 50Hz, 440 volts air cooled condenser with all accessories varied speed including fixing the outdoor unit with suitable factory fabricated steel frame stand as per suitable site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection including copper refrigerant piping with nitrile rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 metres , power cabling to unit, first charging of refrigerant gas including cordless remote, drain piping of suitable size including connecting drain lines from unit to nearest drain points complete all as specified.
Supply, install, testing and commissioning of split air conditioning unit 2 TR capacity Inverter type, HD Filter, complete with cordless remote control, 3 star labeled latest model eco friendly refrigerant gas, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand as site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipes with refrigerant including with nitrile rubber insulation and control cable from indoor to outdoor as required at site, Power cabling from Isolator/ Enclosure to unit, first charging of refrigerant gas, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply & Fix Voltage stabilizer suitable for Inverter Split air conditioner for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140V to 280V with output voltage stabilized at 230 with accuracy ± 2.5% and of capacity suitable for 2.0 TR Inverter AC complete all as specified and directed.
Supply and lay XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade cross sectional area 4 core 25 Sqmm clamped on walls/floors complete all as specified and directed by Engineer in charge.
Supply and lay XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade cross sectional area 4 core 95 Sqmm clamped on walls/floors complete all as specified and directed by Engineer in charge.
Material & Labour for sub main wiring with 2 runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 4 Sqmm PVC insulated FRLS cable as earth continuity wire all as specified and as directed. Note: Three runs of 4 Sqmm, and one run of PVC conduit shall be measured as one length.
Material & Labour for sub main wiring with 4 runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 2.5 Sqmm PVC insulated FRLS cable as earth continuity wire all as specified and as directed. Note: Four runs of 4 Sqmm, one run of 2.5 sqmm and one run of PVC conduit shall be measured as one length.
Supply and fix sheet metal enclosures suitable for 8 Way TPN metal double door suitable for 415 volts, Vertical DB with MCCB as incomer complete all as specified and directed by Engineer in charge.
supply and fix sheet metal enclosures suitable for 4way TPN metal double door suitable for 415 volts, Horizontal DB with FP MCB/isolator as incomer and SP MCBs as outgoing complete all as specified and directed by Engineer in charge.
Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed by Engineer in charge.
Supply and fix 4 Pole MCCB 160 Amp with enclosure, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed by Engineer in charge.
Supply and fix 4 Pole MCCB 120 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed by Engineer in charge.
Supply and fix 4 Pole MCCB 120 Amp with enclosure, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed by Engineer in charge.
Supply & Fix MCB TP 63 Amps at 415 volts, 10KA complete all as specified and directed by Engineer in charge.
Supply & Fix MCB TPN 40 Amps at 415 volts, 10KA complete all as specified and directed by Engineer in charge.
Supply & Fix MCB SP, 0 to 32 Amp C curve, 240 Volt, 10 KA complete all as specified and directed
Supply & Fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp at 240 volts 10 KA, C curve and plug to with male ended portion complete all as specified and directed by Engineer in charge
Supply & Fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB of 32 Amp, 415 volts complete all as specified and directed by Engineer in charge.
Supply & Fix DLP UPVC 3 compartment trunking suitable size to pass indoor to outdoor suction, discharge, drain and wiring of capacity 4.0 ton tower AC with all connected accessories finishing complete with it necessary cutting etc complete all as specified and directed by Engineer in charge.
Supply & Fix 20 mm dia CPVC pipes, SDR-13.5 & plain CPVC SDR 11 fittings, fixed on wall/ceiling with all necessary fittings, solvents complete all as specified and directed.
Supply and fixing copper refrigerant piping of both sizes for suction line 5/8" and 1/4" for discharge including thermal insulation class 'O' nitrile rubber insulation density 45- 55 kg/m³, for suction/ discharge line, beyond standard length provided with original units by the manufacturer complete all as specified and directed by Engineer in charge. Notes: 1) This item shall be measured for the quantity used at site for item No. 1&2 for beyond the length provided by OEM, along with unit. 2) One run of both 5/8" & 1/4" pipes along with insulation shall be measured as one length.
Material & Labour for dismantling Split AC of capacity 1.5/2 TR from existing location including indoor/outdoor unit along with its connected items and making good the surface to match with the existing complete all as directed by Engineer in Charge.
Material & Labour for Earthing complete with galvanised iron earth plate electrode 60cmx60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised 25x4 mm as earth lead dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Material & Labour for Earth continuity conductor or main earthing lead 25x4 mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required
Material &Labour for point wiring with 1.5 Sqmm PVC insulated unsheathed FRLS multistanded single core copper conductor cable in PVC casing capping with all accessories including 1.5 Sqmm PVC insulated copper conductor cable as earth continuity wire and suitable size of PVC switch boxes for enclosing modular switches and sockets for One 5 pin 5 Amps socket point controlled by one switch on same board complete all as specified and directed
Ditto All as per Item No 24, but for One 5 pin 5 Amps socket point controlled by one switch on independent board.
Ditto All as per Item No 24, but with 2.5 Sqmm copper conductor cable including 2.5 sqmm copper cable as earth wire for one 6 pin 16 Amps socket outlet on independent board.
Supply & Fix modular switch One way 6 Amps one module complete all as specified and as directed
Supply & Fix socket modular 6 Amps and 2/3 pin combined two module complete all as specified
Supply & Fix Modular socket 6/16 Amps 2/3 pin combined two module complete all as specified and as directed
Supply & Fix switch 15 A one way SP modular type complete all as specified and as directed
Supply & Fix in existing MCB DBs, MCB "B" curve 40 Amp SPN, 240 volts all as specified and directed.
Supply & Fix in existing MCB DBs, MCB "B" curve SP 6 to 32 Amps, 240 volts all as specified and directed.
Glacier Cooling Solutions Private Limited
M/s VJ ENTERPRISES
V V BHARATH ENTERPRISES
AISWARYA ENTERPRISES
ELSOL ENGINEERS
K.V.GEORGE AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .