Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC HYDERABAD TELANGANA 500076 INDIA UDYAM TS 02 0009467 | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹15.1 L+₹61,886.06 (4.29%)Rejected-Finance | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹16.6 L+₹2.1 L (14.8%)Rejected-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L3 | Rejected-Finance Being not L1. | |
| 4 | L4₹20.0 L+₹5.5 L (38.3%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L4 | Rejected-Finance Being not L1. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Mar 2023, 6:00 pmClosed
GE (AF) MC CHANDIGARH
GE (AF) MC CHANDIGARH
REPAIR/MAINT TO DG SETS WITH OIL, PANELS IN CERTAIN AREA IN 3BRD AF STATION CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2023_MES_579939_1
GE (AF) MC /CHD-75/2022-2023
Open Tender
Civil Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹50,000
Yes
25 Mar 2023
9 Feb 2023
10 Mar 2023
9 Feb 2023
8 Mar 2023
23 Feb 2023
Amount
M&L for opening tappet cover of engine any make of following capacities and carrying out work as under:- (i) Checking and adjusting of tappet clearance. (ii) Cleaning cylinder and piston head by removing carbon deposits (iii) Checking general condition of the engine (iv) Checking and adjustment of operating parameters (v) Checking and adjustment of fuel timing (vi) Checking and adjustment of fault warning system (vii) Checking and adjustment of fasteners (viii) Replacement of the damaged gasket and re-assembling of tappet cover and testing complete all as specified and directed.
DG set capacity 10KVA to 50KVA
DG set capacity 62.5KVA to 82.5KVA
DG set capacity 100KVA to 125KVA
DG set capacity 160KVA
DG set capacity 200KVA
DG set capacity 250KVA
DG set capacity 320KVA
DG set capacity 400KVA to 625KVA
Material and labour for servicing to DG sets 10 KVA to 50 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. ( a) Fuel Filter (Primary & Secondary) - 01 Set, ( b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 62.5 KVA to 82.5 KVA capacity by replacing following spare parts. The servicing should be carriedout by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, ( c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 100 KVA to 125 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No ( d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 160 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 200 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 250 KVA capacity by replacing following spare parts. The servicing should be carried out by representative of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. ( a) Fuel Filter (Primary & Secondaroy) - 01 Set, ( b) Oil Filter - 01 Set, ( c) Air filter - 01 No ( d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 320 KVA to 400KVA capacity by replacing following spare parts. The servicing should be carried out by representative's of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. ( a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for servicing to DG sets 500 KVA to 625 KVA capacity by replacing following spare parts. The servicing should be carried out by representative's of Original Equipment Manufacturer to the entire satisfaction of Engr-in-charge. (a) Fuel Filter (Primary & Secondaroy) - 01 Set, (b) Oil Filter - 01 Set, (c) Air filter - 01 No (d) Engine Oil and Coolant - As per capcity of DG Set. Note : Rate of the Spare parts and Engine oil deemed to be included in quoted rate.
Material and labour for top up lubrication oil Viscosity No SAE 15W/40 for DG sets of capacity 10 KVA to 625 KVA at different locations for top up of the Engine tank complete all as specified and directed. MAKE : Servo /Castrol/Veedol
Supply and fixing in replacement of battery 12 volts 150 AH with 25 Nos plates complete all as directed. Make; Exide - (Little Champ) FLCO-EXLC150R , TATA GREEN - 150G51CV, LUMINOUS - IG 1500
Supply and fixing in replacement of battery 12 volts 180 AH plates comple all as directed. Make; Exide - (Little Champ) FLCO-EXLC180R , TATA GREEN - 180H52CV, LUMINOUS - IL22000
Supply and fixing in replacement of Auto Voltage Regulator suitable for 50 KVA to 160 KVA , 415 V AC as per existing make and pattern complete all as specified and directed. Make: Kirloskar/Stamford/Ashok Lyland
Supply and fixing in repalacement of Auto Voltage Regulator suitable for 200 KVA to 625 KVA , 415 V AC as per existing make and pattern complete all as specified and directed. Make: Kirloskar/Stamford/Ashok Lyland
Material and labour in repair of self starter 12 volts duly rewinding of armature and replacement of unservicable spare parts etc DG Sets capacity from 10KVA to 100KVA DG set including testing complete all as specified and directed.
Material and labour in repair of self starter 24 volts duly rewinding of armature and replacement of unservicable spare parts etc DG Sets capacity from 125KVA to 625KVA DG set ncluding testing complete all as specified and directed.
Material and labour in repair of battery charger including rewinding of transformer and replacement of rectifier,toggle switches,voltmeter, ammeter & MCB etc of capacity 12 volts complete all as specified and directed.
Material and labour in repair of battery charger including rewinding of transformer and replacement of rectifier,toggle switches,voltmeter, ammeter & MCB etc of capacity 24 volts complete all as specified and directed.
Supply and fixing in repair of battery charger including copper wound transformer, rectifier, toggle switches, voltmeter, AM meter & MCB etc of capacity 12 volts complete all as specified and directed.
Supply and fixing in repair of battery charger including copper wound transformer, rectifier, toggle switches, voltmeter, AM meter & MCB etc of capacity 24 volts complete all as specified and directed.
Supply and fixing in replacement of battery lead copper of 50 sqmm as per sample ( Red and Black colour ) battery lead all as specified and directed.
Supply and fixing in replacement of heavy duty battery terminal positive marking /negetaive marking of brass of existing size battery terminal complete all as specified and directed.
Material and labour for top up coolent for DG sets complete all as specified and directed. Make: CASTROL - RADICOOL HEAVY DUTY COOLANT or Equivalent of SERVO , VEEDOL
Supply and fixing in replacement of MCCB 4 pole 160 Amps with adjustable type 36 KA breaking capacity complete all as specified and directed. Make Schneider Cat Part No LV430780 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of MCCB 4 pole 250 Amps with adjustable type 36 KA breaking capacity MCCB all as specified and directed. Make Schneider Cat Part No LV431780 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of MCCB 4 pole 400 Amps with adjustable type, 36 KA breaking capacity complete all as specified and directed. Make Schneider Cat Part No LV432677 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of MCCB 4 pole 630 Amps with adjustable type,50 KA breaking capacity complete all as specified and directed. Make Schneider Cat Part No LV432677 or equivalent make of Hager/ABB/Legrand/Havells
Supply and fixing in replacement of off load Change over switch 4 pole of capacity 400 Amps, AC, 50 Hz, 415 volts with sheet steel enclosure out door type all as directed. Make:Cat No IHCFFE0400 of HAVELLS or equivalent C & S ,Legrand
Supply and fixing in replacement of off load Change over switch 4 pole of capacity 630 Amps, AC, 50 Hz, 415 volts with sheet steel enclosure out door type all as directed. Make: Cat No IHCFFE0630 of HAVELLS or equivalent C & S,Legrand
Supply and fixing in replacement of Dynamo Assy from 10KVA to 50 KVA DG Set to its original position complete all as directed.
Supply and fixing in replacement of Dynamo Assy from 62.5 KVA to 82.5KVA DG Set to its original position complete all as directed.
Supply and fixing in replacement of Dynamo Assy from 125 KVA to 500KVA DG Set to its original position complete all as directed.
M&L for dismantling of radiator assembly from engine, cleaning of the same with suitable cleaning reagent to remove rust & scaling, plugging of any water leakage by brazing and refixing including replacement of rubber hose pipe complete with Jupiter clamps for any capacity of DG sets, complete all as specified and directed.
Supply and fixing in replacement of radiator from the 62.5KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes complete all as specified and directed.
Supply and fixing in replacement of radiator from the 200/250KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes complete all as specified and directed.
Supply and fixing in replacement of radiator from the 320KVA to 500KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes complete all as specified and directed.
Supply and Fixing in replacement of self starter 12 Volts complete all as directed. Make : Audolek or Equivalent
Supply and Fixing in replacement of self starter 24 Volts complete all as directed. Make : Audolek or Equivalent
Supply and fixing in repalacement of Three Phase Ems 926 Controller suitable for 10 KVA to 63 KVA as per existing make and pattern complete all as directed. Make: Kirloskar or as approved by GE.
Supply and fixing in repalacement of Ems 907 Controller suitable for 125 KVA to 500 KVA as per existing make and pattern complete all as directed. Make: Kirloskar or equivalent as approved by GE.
Supply and fixing in repalacement of Under Voltage Relay 415V AC for control Panel as per existing make and pattern complete all as directed. Make: Teknika or equivalent as approved by GE.
Supply and fixing in repalacement of Tripping coil ACB 240 V AC complete all as directed. Make: Siemens or equivalent as approved by GE.
Supply and fixing in repalacement of Contactor 4 Pole 400 Amp 440 volt complete all as directed. Make: Schneider or equivalent as approved by GE.
Supply and fixing in repalacement of Contactor 4 Pole 250 Amp 440 volt complete all as directed. Make: Schneider or equivalent as approved by GE.
Supply and fixing in repalacement of Contactor 4 Pole 95 Amp 440 volt complete all as directed. Make: Schneider or equivalent as approved by GE.
Supply and fixing in repalacement of ACB Closing coil 200 V to 250 V complete all as directed. Make: Schneider or equivalent as approved by GE.
Supply and fixing in repalacement of under voltage release type mv coil 220 V and 415 V complete all as specified and directed. Make: L&T
Supply and fixing in repalacement of Brass oil pressure sensor complete all as directed. Make: Cummins or equivalent as approved by GE.
Supply and fixing in repalacement of Three Phase Kg 934 V2 controller complete all as directed. Make: Kirloskar or equivalent as approved by GE.
Supply and fixing in repalacement of Panel mounting Timer on-delay, 5Amp complete all as directed. Make: Mistura or equivalent as approved by GE.
Supply and fixing in replacement of V-Belt off sizes, Make - Fenner, complete all as per site requirement complete all as specified and directed.
M&L for dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside exhaust pipe and refixing including replacement of worn out rubber gasket packing and nut, bolts complete all as specified and directed.
Dismantling of defective alternator/dynamo from engine, supplying and fixing new alternator 24 Volt DC Make- TVS Lucas, including replacement of worn out nuts bolts mounting clamp etc. complete all as specified and directed.
Supply and fixing in replacement of Oil pressure gauge ISI mark complete all as specified and directed.
Supply and fixing in replacement of oil temperature gauge ISI mark complete all as specified and directed.
Supply and fixing in replacement of Fuel gauge meter ISI mark operated on 24V DC complete all as specified and directed.
Supply and fixing in replacement of high temperature diesel Hose pipe of 1000 PSI of size 12.5mm dia for connecting from diesel tank outlet to Engine complete with banjo bolt & washer complete all as specified and directed.
Supply and fixing in replacement of high temperature diesel Hose pipe of 1250 PSI of size 10.3mm dia for connecting from engine to diesel tank complete with banjo bolt & washer complete all as specified and directed.
M & L for Door joint and handle locks arrangement for any size/capacity DG set complete all as specified and directed.
Supply of new battery charger unit 250 KVA DG Set suitable for 12 V 180 AH with 2m copper leads -02 Nos & brass clamps complete all as specified and directed.
M&L cleaning of diesel tank of DG set of any capacity including replacement of worn out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
M&L for repair and maintenance of FIP for DG set of 40 KVA to 62.5 KVA including replacement of plunzers , Governer kit with pin Nozzles P type , Head ball guide kit, Head sheet (Set of 12 piece) Rock rod , Roller bearing oil seal, piston and rings , Piston pin joint kit and sleeves complete as specified and directed.
M&L for repair and maintenance of FIP for DG set of 82.5 KVA to 200 KVA including replacement of plunzers , Governer kit with pin Nozzles P type , Head ball guide kit, Head sheet (Set of 12 piece) Rock rod , Roller bearing oil seal, piston and rings , Piston pin joint kit and sleeves complete as specified and directed.
M&L for repair and maintenance of FIP for DG set of 250 KVA to 500 KVA including replacement of plunzers , Governer kit with pin Nozzles P type , Head ball guide kit, Head sheet (Set of 12 piece) Rock rod , Roller bearing oil seal, piston and rings , Piston pin joint kit and sleeves complete as specified and directed.
M&L for dismantling of radiator assembly for 10KVA to 62.5KVA capacity DG Sets from engine, cleaning of the same with suitable cleaning reagent to remove rust & scaling , plugging of any water leakage by brazing and refixing including replacement of rubber hose pipe complete with Jupiter clamps complete all as specified and directed.
M&L for dismantling of radiator assembly for 82.5KVA to 200KVA capacity DG Sets from engine, cleaning of the same with suitable cleaning reagent to remove rust & scaling , plugging of any water leakage by brazing and refixing including replacement of rubber hose pipe complete with Jupiter clamps complete all as specified and directed.
M&L for dismantling of radiator assembly for 250KVA to 500KVA capacity DG Sets from engine, cleaning of the same with suitable cleaning reagent to remove rust & scaling , plugging of any water leakage by brazing and refixing including replacement of rubber hose pipe complete with Jupiter clamps complete all as specified and directed.
M&L for dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside barrel and refixing including replacement of worn out rubber gasket packing and nut, bolts complete all as specified and directed.
Supply and fixing in replacement of Electronic Control Panel & Governor for 62.5KVA DG set complete all as specified and as directed. Make Cummins
Supply and fixing in replacement of Electronic Control Panel & Governor for 125 KVA DG set complete all as specified and directed. Make:- Cummins or as approved by GE
Supply and fixing in replacement of Electronic Control Panel & Governor for 200KVA DG set complete all as specified and directed. Make:- Cummins or as approved by GE
Supply and fixing in replacement of solenoid coil suitable for 12 volt DC complete with all connections complete all as specified and directed.
Supply and fixing in replacement of Turbo charger including mounting gas kit complete for 62.5KVA DG set complete all as specified and directed.
Supply and fixing in replacement of Turbo charger including mounting gas kit complete for 200KVA to 500KVA DG set complete all as specified and directed.
M&L for Repair/replacement of water pump for 125KVA to 500 KVA DG set complete all as specified and directed.
M&L for Repair/replacement of water pump for 10KVA to 82.5KVA DG set complete all as specified and directed.
Maintenance, repair, servicing of Automatic Mains Failure panel 24Volt DC and 440Volt AC supply operated system by locating faults and replacement of unserviceable parts and components, for DG set 15KVA to 100KVA, complete all as specified and directed, as per following:- (a) Repair of faulty worn out control wiring DC/AC for engine starting and off, with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing. (b) Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals. (c) Replacement of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order (d) Material and labour, painting of AMF panel metallic body surface with one coat of superior quality synthetic enamel paint of approved colour and 1st quality including replacement of worn out rubber beading. (e) Testing of system on load. Note : Supply & fix, spare parts for replacement where required, shall be measured and paid separately.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc including dismantling of old earthing, complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
Note:- Amount of credit of Rs. 94948.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
Arun enterprises
KUMAR AND COMPANY
TARA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .